Search NASA⌕ Search

SEARCH · Search NASA

Results for “multiplexer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

“Beam à la carte”: Laser heater shaping for attosecond pulses in a multiplexed x-ray free-electron laser

Electron beam shaping allows the control of the temporal properties of x-ray free-electron laser pulses from femtosecond to attosecond timescales. Here, we demonstrate the use of a laser heater to shape electron bunches and enable the generation of attosecond x-ray pulses. We demonstrate that this method can be applied in a selective way, shaping a targeted subset of bunches while leaving the remaining bunches unchanged. This experiment enables the delivery of shaped x-ray pulses to multiple undulator beamlines, with pulse properties tailored to specialized scientific applications.

43 PARTICLE ACCELERATORS↗

Arrayed in vivo barcoding for multiplexed sequence verification of plasmid DNA and demultiplexing of pooled libraries

Sequence verification of plasmid DNA is critical for many cloning and molecular biology workflows. To leverage high-throughput sequencing, several methods have been developed that add a unique DNA barcode to individual samples prior to pooling and sequencing. However, these methods require an individual plasmid extraction and/or in vitro barcoding reaction for each sample processed, limiting throughput and adding cost. Here, we develop an arrayed in vivo plasmid barcoding platform that enables pooled plasmid extraction and library preparation for Oxford Nanopore sequencing. This method has a high accuracy and recovery rate, and greatly increases throughput and reduces cost relative to other plasmid barcoding methods or Sanger sequencing. We use in vivo barcoding to sequence verify >45 000 plasmids and show that the method can be used to transform error-containing dispersed plasmid pools into sequence-perfect arrays or well-balanced pools. In vivo barcoding does not require any specialized equipment beyond a low-overhead Oxford Nanopore sequencer, enabling most labs to flexibly process hundreds to thousands of plasmids in parallel.

59 BASIC BIOLOGICAL SCIENCES↗

Spatially Multiplexed Cluster State Generation

We demonstrate the use of spatially multimode two-mode squeezed states (TMSSs) interfered at beamsplitters to generate an arbitrarily large cluster state. A four-mode state is generated using two TMSSs, leveraging spatial modes of four-wave mixing.

Leger, Zacharie [ORNL] (ORCID:0000000179044775)↗

Multiplexing Focusing Analyzer for Efficient Stress-Strain Measurements

Statement of the problem or situation that is being addressed. Although thermal and cold neutron scattering is widely used and is critical for success in many areas of materials science and engineering, relatively low neutron fluxes severely limit applications of not only laboratory neutrons generators, but also large national neutron facilities. State-of-the-art thermal and cold neutron sources are large expensive national facilities, which serve diverse community of scientific and industrial users. The constant need to improve the instruments performance, stems from the fact that neutron methods are gaining in popularity, and becoming more and more powerful, while new neutron sources are not being constructed to keep pace with the developments and needs of the scientific community. Small research reactors at universities and National Labs, and laboratory-based neutron generators, are necessary not only for education and training, but also when samples cannot be transported to other facilities. However, the standard neutron techniques, which were developed for high-flux facilities, require much higher efficiencies to be used effectively with the low fluxes of small sources. Thus, the efficient use of neutron sources, such as with our proposed analyzer, is important for the progress and broader use of these neutron techniques. General statement of how this problem is being addressed. We propose to design and demonstrate novel diffractive optical device, which will enable very efficient residual stress neutron diffractometers. The proposed device will be a multi-foil analyzer, where each foil is constructed of focusing bent single crystals of Si. Such device will enable polychromatic residual stress neutron diffraction. At large national facilities, such as at Oak Ridge National Laboratory, these analyzers would enable very fast measurements for determining residual stress tensors, raster large samples or screen multiple samples. Commercial Applications and Other Benefits The outcome of this project would be the demonstration of commercial devices, novel neutron optical components, which could be utilized to improve the performance of existing instruments or build novel neutron scattering instruments at DOE neutron facilities and commercial laboratory neutron sources. These new devices will widen the scope of research conducted using neutrons and enable measurements not feasible at present. Summary for Members of Congress Thermal and cold neutron beams are a powerful materials science probe, which provide unique information about the structure of matter. The proposed innovations expand the reach of neutron-based investigations to new materials and industries by enabling new instrumentation capabilities, thereby greatly enhancing and expanding the role of small, laboratory-based neutron instrumentation, and improving education and training of neutron users.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multiplexed Toxin Activity Detection

There is a need for field forward biothreat detection methods for highly lethal marine toxins, such as conotoxins, to protect the warfighter and civilians in contested environments. These toxins arise from harmful algal blooms which impact the warfighter, pets, and civilians. The need for detection platforms that can be fielded on drones or unmanned vehicles is paramount to successful biothreat detection to serve as an early warning system for those impacted in these environments.

59 BASIC BIOLOGICAL SCIENCES↗

Television multiplexing system

System with single, standard, wideband line transmits ten or more real time TV video data displays over hard wire to recorders more than 22.5 km from source. Digital logic and integrated circuits ensure high reliability and low maintenance. System is adaptable for video sampling applications.

Simpkins, L. G.↗

Doubly multiplexing dispersive spectrometer.

Description of a spectrometer that incorporates 19 entrances and 19 exit slots. The instrument's dual capability to perform either one-dimensional imaging or alternately to give a spectrum with a high SNR over the entire source is shown. The instrument operates in the Littrow mode at f/8. The slot width and length for each mask are 0.625 and 3.5 mm, respectively, giving a total aperture length of 12.1 mm. The corresponding resolving power at 1.7 microns is 230.

Phillips, P. G.↗

Gaussian and click noise in an FM/FM multiplex receiver.

An FM/FM system is one in which the signal information frequency modulates a subcarrier, which, in turn, frequency modulates a main carrier for transmission. The detection process then involves two frequency demodulators in sequence. Using Rice's click model for both FM demodulators, we obtain the average click rate and an approximate output spectrum that include the effect of the impulses generated by the carrier demodulator on the subcarrier demodulation at and below threshold. We then focus on the threshold behavior of these systems and the proportioning of their modulation parameters so as to provide certain desired characteristics. We find that due to the filtering action of the second demodulator, the number of output clicks from carrier generated spikes can be orders of magnitude smaller, yet their contribution to the output noise can be much greater than that produced by the first demodulation.

Stochel, N. H.↗