Search NASA⌕ Search

SEARCH · Search NASA

Results for “net zero building”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Energy Innovations for Healthy Buildings

Healthy buildings provide high indoor environmental quality for occupants while simultaneously reducing energy consumption. This project advanced the development and marketability of envisioned healthy, energy-efficient buildings through studies that evaluated the use of emerging technologies in commercial and residential buildings. The project also provided resources required for homebuilders to participate in DOE’s Builders Challenge, concomitant with the goal to reduce energy consumption in homes by at least 30% as a first step toward achieving envisioned widespread availability of net-zero energy homes by 2030. In addition, the project included outreach and education concerning energy efficiency in buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Long-term impact of electrification and retrofits of the U.S residential building in diverse locations

The U.S. buildings sector contributes 30% of operational carbon emissions, with residential buildings accounting for 56%. Reducing residential carbon emissions is crucial for achieving net-zero carbon goal. While many studies examine energy efficiency retrofit (EER) and electrification, few explore their long-term impacts across diverse climates and dynamic grid clean energy penetrations, as well as their economic effects on households. Here, this study proposes a method to assess how EER and electrification affect long-term decarbonization and economics across different climates, focusing on carbon emissions, energy burden (the percentage of household income spent on energy), and payback period in four locations: Tampa, San Diego, Denver, and Great Falls. The study also introduces the concept of implicit energy burden by considering investment costs. Results show that while electrification can reduce long-term emissions with increased clean energy penetration, it may not always achieve decarbonization due to mismatches between clean energy availability and demand. In cooling-dominant locations, electrification lowers energy burden and peak demand, but in heating-dominant locations, it increases energy burden to 8.24%, raises peak demand by 632.78%, and shifts it from summer to winter. After integrating investment costs, the implicit energy burden can reach 8.35% in cold climates. For already highly electrified buildings in Denver and Great Falls, the payback period of EER measures can be shortened by up to 48.98%. The study highlights a tradeoff between decarbonization and energy burden alleviation, showing that while EER measures can reduce the energy burden, they only achieve one-quarter of the carbon emission reduction of electrification.

24 POWER TRANSMISSION AND DISTRIBUTION↗

BEopt™ (Building Energy Optimization Tool) version 3.0.1 3/16/2023 [SWR-05-41]

The BEopt™ (Building Energy Optimization Tool) software provides capabilities to evaluate residential building designs and identify cost-optimal efficiency packages at various levels of whole-house energy savings along the path to zero net energy. The BEopt software can be used to analyze both new construction and existing home retrofits, as well as single-family detached and multi-family buildings, through evaluation of single building designs, parametric sweeps, and cost-based optimizations. The BEopt software provides detailed simulation-based analysis based on specific house characteristics, such as size, architecture, occupancy, vintage, location, and utility rates. Discrete envelope and equipment options, reflecting realistic construction materials and practices, are evaluated. The BEopt software uses EnergyPlus®, the Department of Energy's flagship simulation engine. Simulation assumptions are based on ANSI/RESNET/ICC Standards and the Building America Housing Simulation Protocols. The sequential search optimization technique used by the BEopt software: Finds minimum-cost building designs at different target energy-savings levels Identifies multiple near-optimal designs along the path, allowing for equivalent solutions based on builder or contractor preference. Download A BEopt™ Version 3.0.1 Beta release (Mar. 16, 2023) is now available. Download the BEopt 3.0.1 Beta setup file.

Christensen, Craig↗

Robustness of energy performance of Zero-Net-Energy (ZNE) homes

Zero-net-energy (ZNE) homes produce an adequate amount of energy on-site to meet their energy demand based on source energy for an entire year. California building energy efficiency standards require new residential buildings started in 2020 to be ZNE. For various reasons, a home designed as ZNE may not achieve ZNE performance in real operation. Here we aimed to quantify the robustness of the energy performance of ZNE homes due to weather variability, climate change, and the uncertainty of occupant behavior. A single-family ZNE house, based on the optimal cost-effective design in three California climate zones, was used to develop the EnergyPlus simulation models. Weather variations were considered from a combination of the historical 30 years’ actual meteorological year (AMY) weather data, typical year weather data in TMY3, and future weather data based on Intergovernmental Panel on Climate Change scenarios. Three scenarios of occupant behavior from the energy perspective were defined to represent the uncertainty about occupants’ activities, comfort requirements, and their adaptive interactions with buildings and systems. In terms of annual source energy, the simulation results of the ZNE homes showed: (1) a decrease of 23–38 percent for occupants with energy austerity behavior and an increase of 120–130 percent for occupants with energy wasteful behavior, compared with the baseline assumption of normal occupants; (2) a variation range of –15 percent to +14 percent for the results using 30-year AMY weather data compared with the baseline results using TMY3 weather data; (3) an increase of 10–13 percent with future weather in Fresno and Riverside and a decrease of 15 percent with San Francisco; and (4) climate change can reduce the gap between the austerity and wasteful consumption. These findings provide insights into how ZNE homes may perform in reality and inform architects, engineers, occupants, and policymakers to pay more attention to occupant behavior on design, operation, and regulations of ZNE homes to ensure energy performance robustness.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Measuring and Understanding the Energy Use Signatures of a Bank Building

The Pacific Northwest National Laboratory measured and analyzed the energy end-use patterns in a bank building located in the north-eastern United States. This work was performed in collaboration with PNC Financial Service Group under the US DOE’s Commercial Building Partnerships Program. This paper presents the metering study and the results of the metered data analysis. It provides a benchmark for the energy use of different bank-related equipments. The paper also reveals the importance of metering in fully understanding building loads and indentifying opportunities for energy efficiency improvements that will have impacts across PNC’s portfolio of buildings and were crucial to reducing receptacle loads in the design of a net-zero bank branches. PNNL worked with PNC to meter a 4,000 ft2 bank branch in the state of Pennsylvania. 71 electrical circuits were monitored and 25 stand-alone watt-hour meters were installed at the bank. These meters monitored the consumption of all interior and exterior lighting, receptacle loads, service water heating, and the HVAC rooftop unit at a 5-minute sampling interval from November 2009 to November 2010. A total of over 8 million data records were generated, which were then analyzed to produce the end-use patterns, daily usage profiles, rooftop unit usage cycles, and inputs for calibrating the energy model of the building.

ASHRAE↗

Natural Gas Community of the Future (Final Report)

Nicor Gas, a subsidiary of Southern Company Gas and its parent company Southern Company, is developing the concept of the Carbon-neutral, Affordable, Resilient, and Equitable Community ("CARE Community") to address the challenges of accessibility and affordability of grid-interactive efficient buildings in historically disadvantaged communities. The CARE Community is a new construction net-zero energy and carbon neutral residential neighborhood consisting of 50 homes with electricity and natural gas services in South Suburban Chicago, built as low-income affordable housing. The National Renewable Energy Laboratory (NREL) is assisting Southern Company to explore how energy efficiency, renewable technologies, and the reliability and resilience of natural gas can be combined and optimized in an islandable energy system as part of a broader effort to understand the role natural gas plays in future communities integrated with renewable energy and improved energy efficiency. The CARE Community will demonstrate how energy efficiency, distributed energy resources (DERs), and advanced controls can be combined with existing natural gas infrastructure to serve historically disadvantaged communities in a cold climate with low energy cost for affordable housing programs and enhanced resilience to withstand extreme weather. Homes will be a part of an islandable energy system, integrating multiple DER technologies such as solar panels, natural gas fuel cells, reciprocating natural gas engines, and battery storage. The CARE Community will provide a replicable template that affordable housing developers and energy companies can adopt throughout the United States. In this report, we present the design and modeling of the community and potential approaches for integrating DERs. We analyze and discuss annual simulations under normal operating conditions and week-long simulations under electric power grid outage conditions.

03 NATURAL GAS↗

Net Zero Energy Analysis Approach for Military Installations

Net zero energy is a concept of energy self-sufficiency based on minimized demand and use of local renewable energy resources. A net zero energy military installation is defined as: 'A military installation that produces as much energy on-site from renewable energy generation or through the on-site use of renewable fuels, as it consumes in its buildings, facilities, and fleet vehicles.' [1] TheNational Renewable Energy Laboratory (NREL) developed a comprehensive, first-of-its-kind strategy for evaluating a military installation's potential to achieve net zero energy status, including an assessment of baseline energy use, energy use reduction opportunities from efficiency or behavior changes, renewable energy generation opportunities, electrical systems analysis of renewableinterconnection, microgrid potential, and transportation energy savings. This paper describes NREL's net zero energy assessment strategy and provides a planning guide for other organizations interested in evaluating net zero potential. We also present case studies and describe lessons learned from NREL's net zero energy assessments at seven installations, including the importance of enforcing and funding mandates, providing leadership support, collecting accurate data, and selecting appropriate technologies. Finally, we evaluate whether the net zero concept is a useful framework for analyzing an energy strategy and a reasonable goal.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Estimating Future Changes of Energy Demand for Heating and Cooling Buildings at NASA Centers GC23J-1198

With its unique and trusted earth observations, NASA is a critical source in informing decisions that will help achieve the U.S. goal of Net-Zero Greenhouse Gas (GHG) Emissions by 2050. NASA’s Prediction of Worldwide Energy Resource (POWER) project facilitates the use of NASA Earth Science data holdings within the energy, agricultural, and building heating/cooling design industries. POWER packages solar and meteorological data from several NASA projects in a user friendly GIS-enabled web services system (https://power.larc.nasa.gov). As part of the development of new data products to support the energy and building heating/cooling design communities, we estimate the changes in energy required to heat and cool buildings in the future climate at 14 different NASA site locations spread throughout the continental United States, as projected by CMIP6 climate models under different emissions scenarios. Bias-corrected downscaled time series of meteorological variables are taken from NASA Earth Exchange (NEX) Global Daily Downscaled Projections (GDDP-CMIP6) downscaled climate model data. The spread between the different model projections is accounted for by analyzing both the ensemble average of 22 CMIP6 models and 6 representative models with different climate sensitivities and different interannual variability. Changes in energy use are estimated in two ways. First, changes in the total annual heating and cooling degree days (HDD and CDD, respectively) are calculated relative to the current climate. This is done at all 14 sites. Second, the downscaled time series are used as inputs into RETScreen(R), a clean energy management decision tool, to give an estimate of heating/cooling energy use for a typical office building. We use this estimation method with model data at Langley Research Center. In the next 50 years, the annual total of HDD (CDD) is projected to decrease by 8-38% (increase by 5-28%) at all sites, with the increase in CDD typically a larger magnitude the decrease in HDD. For a typical small office building at Langley Research Center, the amount of energy needed to cool increases by 33-54% and the amount of energy to heat decreases by 29-40%. POWER is working to develop long term climate data services based on these results to include in future data products to provide to users.

Bradley M. Hegyi↗

PHASE CHANGE MATERIAL FOR THERMAL ENERGY STORAGE IN BUILDINGS BASED ON SODIUM SULFATE DECAHYDRATE AND DISODIUM HYDROGEN PHOSPHATE DODECAHYDRATE

The worldwide increasing energy demand and 2050 net zero carbon target urge the globe to solve the energy challenge. Thermal Energy Storage (TES) has received significant attention in recent years as TES can be integrated into heating, ventilation, and air-conditioning systems where the energy would be stored during low-demand times and dispatched during high-demand times, resulting in controlling the peak load and improving energy savings. Material development is an integral part of TES. Salt hydrates are appealing due to cost-effectiveness, low- to no toxicity, and their high melting enthalpy, where energy is stored as latent heat. However, most salt hydrates are prone to incongruent melting (i.e., phase separation upon melting), which results in poor stability and large supercooling. In this study, we produced a highly stable novel energy storage material at a composition of 32 wt% sodium sulfate decahydrate, 52 wt% sodium phosphate dibasic dodecahydrate, 12 wt% milled expanded graphite, and 4 wt% borax. The material has a melting temperature of 28°C and an energy storage capacity of 167 kJ/kg with a supercooling of less than 3°C. The system showed no loss in energy storage performance after 150 cycles. The findings suggest that the novel energy storage material developed in this might be utilized in building heating and cooling applications.

Turnaoglu, Tugba↗

INL High-Performance and Sustainable Building Strategy

High-performance buildings are reliable, cost effective, and sustainable structures that minimize energy and water use, reduce solid waste and pollutant emissions, and limit the depletion of natural resources. High-performance buildings also provide a thermally and visually comfortable working environment that increases productivity for building occupants. As Idaho National Laboratory (INL) is the nation’s premier nuclear energy research laboratory, the physical infrastructure requires continual updating and repurposing to help accomplish that mission. INL’s infrastructure must incorporate high-performance sustainable design features to be fiscally responsible and reflect an image of innovation to the public and prospective employees. INL is a large consumer of energy with annual energy costs exceeding $16M. This High-Performance and Sustainable Building Strategy will help engineering and construction project teams design sustainable facilities, reduce life cycle operating costs, and support the INL net-zero plan while providing INL employees with a safe and healthy working environment. With these goals in mind, the recommendations described in this document are intended to form INL’s foundation for sustainable and high-performance building standards. This strategy incorporates the latest federal and Department of Energy (DOE) orders and directives, including DOE Order 436.1A, “Departmental Sustainability,” the DOE Sustainability Plan (SP), the INL Site Sustainability Plan (SSP), and Code of Federal Regulations (CFR). This document identifies the requirements of the “Guiding Principles for Sustainable Federal Buildings” (Guiding Principles) and briefly highlights the Leadership in Energy and Environmental Design (LEED) Gold certification. LEED Gold certification can be used to meet many of the requirements of the Guiding Principles.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

West Village Student Housing Phase I: Apartment Monitoring and Evaluation

Building America team Alliance for Residential Building Innovation (ARBI) worked with the University of California, Davis and the developer partner West Village Community Partnership (WVCP) to evaluate performance on 192 student apartments completed in September, 2011 as part of Phase I of the multi-purpose West Village project. West Village is the largest planned zero net energy community in the United States. The campus neighborhood is designed to enable faculty, staff, and students to affordably live near campus, take advantage of environmentally friendly transportation options, and participate fully in campus life. The aggressive energy efficiency measures that are incorporated in the design contribute to source energy reductions of 37% over the B10 Benchmark. These measures include increased wall and attic insulation, high performance windows, high efficiency heat pumps for heating and cooling, central heat pump water heaters (HPWHs), 100% high efficacy lighting, and ENERGY STAR major appliances. The report discusses how measured energy use compares to modeling estimates over a 10-month monitoring period and includes a cost effective evaluation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Technology Solutions Case Study: High-Performance Walls in Hot-Dry Climates

In this project,the Alliance for Residential Building Innovation (ARBI) team worked with builders in California to implement wall assemblies meeting a U-value lower than 0.050 Btu/h-ft2-°F. ARBI and its project team members helped builders identify preferred wall designs that met the requirements of their architects, structural engineers, and purchasing agents and that were acceptable to their subcontractors. Construction methods were observed and documented and construction costs obtained from builders were used to inform cost estimates for a range of advanced wall system types and insulation types. Wall framing types of 2 × 6 (16- and 24-in. on center [o.c.]) and double stud were modeled in Building Energy Optimization (BEopt™) software with cavity insulation levels ranging from R-19 to R-33 (double stud) and exterior rigid insulation of R-4, R-6, and R-8.

ARBI↗