Search NASA⌕ Search

SEARCH · Search NASA

Results for “nickel electrodes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Making a Lightweight Battery Plaque

Plaque formed in porous plastic by electroless plating. Lightweight plaque prepared by electroless plating of porous plastic contains embedded wire or expanded metal grid. Plastic may or may not be filled with soluble pore former. If it contains soluble pore former, treated to remove soluble pore former and increase porosity. Porous plastic then clamped into rig that allows plating solutions to flow through plastic. Lightweight nickel plaque used as electrode substrate for alkaline batteries, chiefly Ni and Cd electrodes, and for use as electrolyte-reservoir plates for fuel cells.

Reid, M. A.↗

Strong, Low-Resistance Bonds For AMTEC Electrodes

Heat of operating cell helps form contacts. Strong, low-electrical-resistance contacts between elements of current-collection grid in alkali-metal thermoelectric converter (AMTEC) cell obtained by simple in-place thermocompression bonding. Bonds formed between porous electrode of molybdenum film, nickel or cobalt strips overlying film, and molybdenum tie wires running at right angles to strips. Bonding method also works on films of tungsten or tungsten/platinum.

Williams, Roger M.↗

Long Life Na/NiCl2 Cells

The premature capacity failure of Na/NiCl2 secondary cells due to agglomeration of nickel particles on the surface of the NiCl2 cathode is prevented by addition of a minor amount such as 10 percent by weight of a transition metal such as Co, Fe or Mn to the cathode. The chlorides of the transition metals have lower potentials than nickel chloride and chlorinate during charge. A uniform dispersion of the transition metals in the cathodes prevents agglomeration of nickel, maintains morphology of the electrode, maintains the electrochemical area of the electrode and thus maintains capacity of the electrode. The additives do not effect sintering. The addition of sulfur to the liquid catholyte is expected to further reduce agglomeration of nickel in the cathode.

Bugga, Ratnakumar V.↗

The self-discharge of the NiOOH/Ni(OH)2 electrode constant potential study

Hydrogen oxidation currents at a NiOOH/Ni(OH)2 electrode were measured directly at constant potentials for various hydrogen pressures and states of charge. It was found that the hydrogen oxidation current is linearly proportional to the hydrogen pressure at all electrode potentials and that the logarithm of the anodic current is a linear function of electrode potential. It was also found that hydrogen oxidation on the nickel substrate material was strongly inhibited by the presence of nickel hydroxide on the substrate surface. By comparing the currents for hydrogen oxidation and oxygen evolution on the NiOOH/Ni(OH)2 electrode and a nickel substrate, it is suggested that the self-discharge of the NiOOH/Ni(OH)2 electrode is mainly due to electrochemical oxidation of hydrogen on the active electrode material.

Mao, Z.↗

Sintered plaque characteristics

The structural transformations occurring during sintering, the fabrication of a slurry produced sintered plaque, are detailed. Degradation of the positive electrode in performance in cycling in a nickel hydrogen battery were traced to the quality of the sintered plaque. Electrode degradation was found to be a limiting factor in the battery cycle life. Details of microstructural characterization and distribution of pores, examination of plastic flow during shrinkage, and observations of the rounding of nickel powder particles during the slurry process are presented.

Vaidyanathan, H.↗

Assessment of commercially available and experimental hydrogen electrodes

NASA Lewis Research Center is currently involved in advanced cell component development for nickel-hydrogen cells and batteries. Long life, high energy density, improved performance and reliability are required for energy storage systems in future space missions. Commercially available as well as experimental hydrogen electrodes were assessed and copared to the state-of-the-art hydrogen electrode that is currently being used in nickel-hydrogen batteries. These electrodes were evaluated by scanning electron microscopy and standard electrochemical polarization measurements. Production variables such as Teflon content and platinum catalyst loading were considered in order to assess various hydrogen electrods with regard to the different electrode manufacturing processes.

Charleston, J. A.↗

Assessment of commercially available and experimental hydrogen electrodes

NASA Lewis Research Center is currently involved in advanced cell component development for nickel-hydrogen cells and batteries. Long life, high energy density, improved performance and reliability are required for energy storage systems in future space missions. Commercially available as well as experimental hydrogen electrodes were assessed and compared to the state-of-the-art hydrogen electrode that is currently being used in nickel-hydrogen batteries. These electrodes were evaluated by scanning electron microscopy and standard electrochemical polarization measurements. Production variables such as Teflon content and platinum catalyst loading were considered in order to assess various hydrogen electrodes with regard to the different electrode manufacturing processes.

Charleston, Jo Ann↗

Electron emission from nickel-alloy surfaces in cesium vapor

The cesiated electron emission was measured for three candidate electrodes for use as collectors in thermionic converters. Nickel, Inconel 600 and Hastelloy were tested with a 412 K cesium reservoir. Peak emission from the alloys was found to be comparable to that from pure nickel. Both the Inconel and the Hastelloy samples had work functions of 1.64 eV at peak emission. The minimum work functions were estimated to be 1.37 eV at a probe temperature of 750 K for Inconel and 1.40 eV for Hastelloy at 665 K. The bare work function for both alloys is estimated to be approximately the same as for pure nickel, 4.8 eV.

Manda, M.↗

NiCd battery electrodes, C-150

Electrodes for a nongassing negative limited nickel-cadmium cell are discussed. The key element is the development of cadmium electrodes with high hydrogen overvoltage. For this, the following electrode structures were manufactured and their physical and electrochemical characteristics were evaluated: (1) silver-sinter-based Cd electrodes, (2) Teflon-bonded Cd electrodes, (3) electrodeposited Cd sponge, and (4) Cd-sinter structures.

Holleck, G.↗

NiCd battery electrodes

The objective of this research program was to develop and evaluate electrodes for a negative limited nickel-cadmium cell and to prove its feasibility. The program consisted of three phases: (1) the development of cadmium electrodes with high hydrogen overvoltage characteristics, (2) the testing of positive and negative plates, and (3) the fabrication and testing of complete negative limited NiCd cells. The following electrode structures were manufactured and their physical and electrochemical characteristics were evaluated: (1) silver sinter-based Cd electrodes, (2) Teflon-bonded Cd electrodes, (3) electrodeposited Cd sponge, and (4) Cd-sinter structures. All cadmium electrode structures showed a sharp increase in potential at the end of charge, with the advent of hydrogen evolution occurring at approximately -1.3 V versus Hg/HgO. The hydrogen advent potentials on pure cadmium structures were 50 to 70 mV more cathodic than those of their silver-containing counterparts.

Holleck, G.↗

NiCd battery electrodes, C-150

A research program to develop and evaluate electrodes for a nongassing negative limited nickel-cadmium cell is described. The concept of the negative limited cell and its implications on electrode structure are discussed. The key element is the development of a cadmium electrode with high hydrogen overvoltage. For this, Teflon-bonded Cd electrodes and silver-sinter based Gc electrodes were manufactured and in preliminary experiments their physical and electrochemical characteristics were evaluated. Hydrogen evolution on cadmium was found to occur approximately 100 mV more cathodic than on silver. Both electrode structures exhibit a fairly sharp potential rise at the end of the charging cycle and the advent of gas evolution occurs at potentials between -1.2 and -1.3 V versus a Hg/HgO reference electrode. These results are compared with conventional Ni-sinter based Cd electrodes.

Holleck, G.↗

Measuring Elastic Modulus of Sintered Metal

Technique minimizes effect of substrate on thin sintered coating. Uniaxial tension test yields approximate value for elastic modulus of sintered material on thin substrate. Electrode composed of central perforated nickel plated steel sheet about 4 mils (0.1mm) thick, coated on each face by porous sintered nickel about 8 mils (0.2mm) thick.

Fedors, R. F.↗

Comparison of Standard and Heart-pacer Type 3rd Electrodes in Design Variable Cells

Nine packs of sealed aerospace nickel cadmium cells were put on life test in February 1979. Each 5 cell pack contained one cell with a standard sensor signal electrode and one cell with a new heart pacer sensor signal electrode. Testing was discontinued in May 1983 and the signal electrode performance data was studied. It was found that the heart pacer electrode generally provided a greater voltage swing over a cycle; that both types of electrodes lost significant sensitivity during life, and that both types of electrodes show great signal variation from cell to cell.

Morrow, G. W.↗

Systems and Methods for the Electrodeposition of a Nickel-cobalt Alloy

Systems and methods for electrodepositing a nickel-cobalt alloy using a rotating cylinder electrode assembly with a plating surface and an electrical contact. The assembly is placed within a plating bath and rotated while running a plating cycle. Nickel-cobalt alloy deposition is selectively controlled by controlling current density distribution and/or cobalt content in the plating bath while running the plating cycle to deposit an alloy of a desired yield strength onto the plating surface in a single plating cycle. In various embodiments, the rotating cylinder may be used as an insitu monitoring method to assist in obtaining the properties desired.

Ogozalek, Nance Jo↗

Special Test Methods for Batteries

Various methods are described for measuring heat generation in primary and secondary batteries as well as the specific heat of batteries and cell thermal conductance. Problems associated with determining heat generation in large batteries are examined. Special attention is given to monitoring temperature gradients in nickel cadmium cells, the use of auxiliary electrodes for conducting tests on battery charge control, evaluating the linear sweep of current from charge to discharge, and determining zero current voltage. The fast transient behavior of batteries in the microsecond range, and the electrical conductance of nickel sinters in the thickness direction are also considered. Mechanical problems experienced in the vibration of Ni-Cd batteries and tests to simulate cyclic fatigue of the steel table connecting the plates to the comb are considered. Methods of defining the distribution of forces when cells are compressed during battery packaging are also explored.

Gross, S.↗