Search NASA⌕ Search

SEARCH · Search NASA

Results for “nuclear pulse processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Long coherence times in nuclear spin-free vanadyl qubits

Quantum information processing (QIP) offers the potential to create new frontiers in fields ranging from quantum biology to cryptography. Two key figures of merit for electronic spin qubits, the smallest units of QIP, are the coherence time ( T 2 ), the lifetime of the qubit, and the spin–lattice relaxation time (T 1 ), the thermally defined upper limit of T 2 . To achieve QIP, processable qubits with long coherence times are required. Recent studies on (Ph 4 P-d 20 ) 2 [V(C 8 S 8 ) 3 ], a vanadium-based qubit, demonstrate that millisecond T 2 times are achievable in transition metal complexes with nuclear spinfree environments. Applying these principles to vanadyl complexes offers a route to combine the previously established surface compatibility of the flatter vanadyl structures with a long T 2 . Toward those ends, we investigated a series of four qubits, (Ph 4 P) 2 [VO(C 8 S 8 ) 2 ] (1), (Ph 4 P) 2 [VO(β-C 3 S 5 ) 2 ] (2), (Ph 4 P) 2 [VO(α-C 3 S 5 ) 2 ] (3), and (Ph 4 P) 2 [VO(C 3 S 4 O) 2 ] (4), by pulsed electron paramagnetic resonance (EPR) spectroscopy and compared the performance of these species with our recently reported set of vanadium tris(dithiolene) complexes. Crucially we demonstrate that solutions of 1–4 in SO 2 , a uniquely polar nuclear spinfree solvent, reveal T 2 values of up to 152(6) μs, comparable to the best molecular qubit candidates. Upon transitioning to vanadyl species from the tris(dithiolene) analogues, we observe a remarkable order of magnitude increase in T 2 , attributed to stronger solute–solvent interactions with the polar vanadium-oxo moiety. Simultaneously, we detect a small decrease in T 2 for the vanadyl analogues relative to the tris(dithiolene) complexes. We attribute this decrease to the absence of one nuclear spinfree ligand, which served to shield the vanadium centers against solvent nuclear spins. Lastly, our results highlight new design principles for long T 1 and T 2 times by demonstrating the efficacy of ligand-based tuning of solute–solvent interactions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Impacts of Neodymium Complexation on Radiolysis of Tetramethyl Diglycolamide (TMDGA) in Aqueous Solutions

Hydrophilic diglycolamides (DGA) ligands have been explored for use as stripping agents in various lanthanide and actinide partitioning processes.1 The separation of lanthanide fission products and transplutonic actinides can serve multifaceted advantages, in that the separation of neutron poisoning rare earth element (REE) fission products from the minor actinides in used nuclear fuel (UNF) can be mutually beneficial to the fundamental research behind REE separations and UNF separations. Considerable efforts have been devoted to understanding the radiation chemistry of hydrophilic DGAs. However, recent studies with lipophilic DGAs have shown that metal ion complexation can promote significant changes in their radiolytic susceptibility.2,3 These effects have been attributed to various parameters, including delocalization of electron density, the presence of radiolytically more susceptible counter ions, and steric hindrance. As such, it is pivotal for these complexation effects to be more thoroughly probed to establish mechanistic knowledge for their effects on hydrophilic DGA molecules. Here we present a time-resolved electron pulse and accumulated gamma dose irradiation study on neodymium ion complexes of tetramethyl diglycolamide (TMDGA) under aqueous solution conditions. References (1) Rostaing, C.; Poinssot, C.; Warin, D.; Baron, P.; Lorrain, B. Development and Validation of the EXAm Separation Process for Single Am Recycling. Procedia Chem. 2012, 7, 367–373. https://doi.org/doi: 10.1016/j.proche.2012.10.057. (2) Horne, G. P.; Conrad, J. K.; McLachlan, J. R.; Rotermund, B. M.; Cook, A. R.; Celis-Barros, C.; Mezyk, S. P. Impact of Lanthanide Complexation and Temperature on the Chemical Reactivity of N,N,N’,N’-Tetraoctyl Diglycolamide (TODGA) with the Dodecane Radical Cation. Phys. Chem. Chem. Phys. 2023, Under Review. (3) Kimberlin, A.; Saint-Louis, G.; Guillaumont, D.; Camès, B.; Guilbaud, P.; Berthon, L. Effect of Metal Complexation on Diglycolamide Radiolysis: A Comparison between Ex Situ Gamma and in Situ Alpha Irradiation. Phys. Chem. Chem. Phys. PCCP 2022, 24 (16), 9213–9228. https://doi.org/10.1039/d1cp05731f.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Study of laser megajoule calorimeter's thermal behaviour for energy measurement uncertainty optimisation

For laser megajoule (LMJ) facility, an accurate procedure for laser pulse energy measurement is a crucial requirement. In this study, the influence of measurement procedure on LMJ calorimeter uncertainty is experimentally and numerically investigated. To this end, a 3D thermal model is developed and two experimental techniques are implemented. The metrological characteristics of both techniques are presented. As a first step, the model is validated by comparing numerical and experimental results. Then, the influence of a large number of parameters considered as likely uncertainty sources on calorimeter response is investigated: wavelength, pulse duration, ambient temperature, laser beam diameter Horizontal-Ellipsis . The post processing technique procedure is also examined. The paper provides some of the parameters required to allow a robust and efficient calibration procedure to be produced.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SECULAR EVOLUTION OF COMPACT BINARIES NEAR MASSIVE BLACK HOLES: GRAVITATIONAL WAVE SOURCES AND OTHER EXOTICA

The environment near supermassive black holes (SMBHs) in galactic nuclei contains a large number of stars and compact objects. A fraction of these are likely to be members of binaries. Here we discuss the binary population of stellar black holes and neutron stars near SMBHs and focus on the secular evolution of such binaries, due to the perturbation by the SMBH. Binaries with highly inclined orbits with respect to their orbit around the SMBH are strongly affected by secular Kozai processes, which periodically change their eccentricities and inclinations (Kozai cycles). During periapsis approach, at the highest eccentricities during the Kozai cycles, gravitational wave (GW) emission becomes highly efficient. Some binaries in this environment can inspiral and coalesce at timescales much shorter than a Hubble time and much shorter than similar binaries that do not reside near an SMBH. The close environment of SMBHs could therefore serve as a catalyst for the inspiral and coalescence of binaries and strongly affect their orbital properties. Such compact binaries would be detectable as GW sources by the next generation of GW detectors (e.g., advanced-LIGO). Our analysis shows that {approx}0.5% of such nuclear merging binaries will enter the LIGO observational window while on orbits that are still very eccentric (e {approx}> 0.5). The efficient GW analysis for such systems would therefore require the use of eccentric templates. We also find that binaries very close to the SMBH could evolve through a complex dynamical (non-secular) evolution, leading to emission of several GW pulses during only a few years (though these are likely to be rare). Finally, we note that the formation of close stellar binaries, X-ray binaries, and their merger products could be induced by similar secular processes, combined with tidal friction rather than GW emission as in the case of compact object binaries.

79 ASTRONOMY AND ASTROPHYSICS↗

Tomographic Reconstruction of the Neutron Time-Energy Spectrum from a Dense Plasma Focus

A dense plasma focus (DPF) nuclear fusion device is an attractive pulsed neutron source in many applications, due to its relatively large neutron yield, produced in a short time duration. In order to design a DPF that generates neutrons within a specified time profile, or generates a neutron energy spectrum with specific properties, it is necessary to be able to characterize and model the results of the fusion process releasing the neutrons. The time-energy spectrum of fusion neutrons is an ideal quantity to use to validate multiphysics codes that simulate the pinch and fusion processes, because it is a quantity that requires the physics of each of the stages leading up to and ending in the fusion reaction to be simulated correctly. In particular, since DPF fusion neutrons are not monoenergetic -- and there can often be several fusion pinches creating neutrons -- a computer simulation matching high quality neutron spectrum measurements provides great confidence in the fidelity of the simulation. In order to make such a comparison, it is first necessary to have quality measurements from which to infer the spectrum. In this work we pose neutron spectroscopy as the classical tomographic inverse problem from neutron time of flight data at multiple distances, but enhanced by using an additional measurement of the time profile of the fusion pinch near its source and by using detector pairs set up in a geometry that allows for scatter background subtraction. The detector pairs enhance the quality of the time of flight measurements, and the additional constraint posed by the measured time profile allows for reconstructions discretized as finely as the time measurements and in energy as finely as 100 keV, without the problem being underdetermined. We present results from a Deuterium-fueled DPF at the U.S. Department of Energy's Nevada National Security Site and show that we can infer the time-energy spectrum from our measurements for both single and multi-pinch fusion reactions with equal fidelity.

Catenacci, Jared↗

Characterization of scatter in digital mammography from use of Monte Carlo simulations and comparison to physical measurements

Purpose: Monte Carlo simulations were performed with the goal of verifying previously published physical measurements characterizing scatter as a function of apparent thickness. A secondary goal was to provide a way of determining what effect tissue glandularity might have on the scatter characteristics of breast tissue. The overall reason for characterizing mammography scatter in this research is the application of these data to an image processing-based scatter-correction program. Methods: MCNPX was used to simulate scatter from an infinitesimal pencil beam using typical mammography geometries and techniques. The spreading of the pencil beam was characterized by two parameters: mean radial extent (MRE) and scatter fraction (SF). The SF and MRE were found as functions of target, filter, tube potential, phantom thickness, and the presence or absence of a grid. The SF was determined by separating scatter and primary by the angle of incidence on the detector, then finding the ratio of the measured scatter to the total number of detected events. The accuracy of the MRE was determined by placing ring-shaped tallies around the impulse and fitting those data to the point-spread function (PSF) equation using the value for MRE derived from the physical measurements. The goodness-of-fit was determined for each data set as a means of assessing the accuracy of the physical MRE data. The effect of breast glandularity on the SF, MRE, and apparent tissue thickness was also considered for a limited number of techniques. Results: The agreement between the physical measurements and the results of the Monte Carlo simulations was assessed. With a grid, the SFs ranged from 0.065 to 0.089, with absolute differences between the measured and simulated SFs averaging 0.02. Without a grid, the range was 0.28–0.51, with absolute differences averaging −0.01. The goodness-of-fit values comparing the Monte Carlo data to the PSF from the physical measurements ranged from 0.96 to 1.00 with a grid and 0.65 to 0.86 without a grid. Analysis of the data suggested that the nongrid data could be better described by a biexponential function than the single exponential used here. The simulations assessing the effect of breast composition on SF and MRE showed only a slight impact on these quantities. When compared to a mix of 50% glandular/50% adipose tissue, the impact of substituting adipose or glandular breast compositions on the apparent thickness of the tissue was about 5%. Conclusions: The findings show agreement between the physical measurements published previously and the Monte Carlo simulations presented here; the resulting data can therefore be used more confidently for an application such as image processing-based scatter correction. The findings also suggest that breast composition does not have a major impact on the scatter characteristics of breast tissue. Application of the scatter data to the development of a scatter-correction software program can be simplified by ignoring the variations in density among breast tissues.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TH-CD-207B-06: Swank Factor of Segmented Scintillators in Multi-Slice CT Detectors: Pulse Height Spectra and Light Escape

Purpose: Pulse height spectra (PHS) have been used to determine the Swank factor of a scintillator by measuring fluctuations in its light output per x-ray interaction. The Swank factor and x-ray quantum efficiency of a scintillator define the upper limit to its imaging performance, i.e. DQE(0). The Swank factor below the K-edge is dominated by optical properties, i.e. variations in light escape efficiency from different depths of interaction, denoted e(z). These variations can be optimized to improve tradeoffs in x-ray absorption, light yield, and spatial resolution. This work develops a quantitative model for interpreting measured PHS, and estimating e(z) on an absolute scale. The method is used to investigate segmented ceramic GOS scintillators used in multi-slice CT detectors. Methods: PHS of a ceramic GOS plate (1 mm thickness) and segmented GOS array (1.4 mm thick) were measured at 46 keV. Signal and noise propagation through x-ray conversion gain, light escape, detection by a photomultiplier tube and dynode amplification were modeled using a cascade of stochastic gain stages. PHS were calculated with these expressions and compared to measurements. Light escape parameters were varied until modeled PHS agreed with measurements. The resulting estimates of e(z) were used to calculate PHS without measurement noise to determine the inherent Swank factor. Results: The variation in e(z) was 67.2–89.7% in the plate and 40.2–70.8% in the segmented sample, corresponding to conversion gains of 28.6–38.1 keV{sup −1} and 17.1–30.1 keV{sup −1}, respectively. The inherent Swank factors of the plate and segmented sample were 0.99 and 0.95, respectively. Conclusion: The high light escape efficiency in the ceramic GOS samples yields high Swank factors and DQE(0) in CT applications. The PHS model allows the intrinsic optical properties of scintillators to be deduced from PHS measurements, thus it provides new insights for evaluating the imaging performance of segmented ceramic GOS scintillators.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electrostatic quadrupole plasma mass spectrometer measurements during thin film depositions using simultaneous matrix assisted pulsed laser evaporation and magnetron sputtering

A hybrid plasma deposition process, combining matrix assisted pulsed laser evaporation (MAPLE) of carbon nanopearls (CNPs) with magnetron sputtering of gold was investigated for growth of composite films, where 100 nm sized CNPs were encapsulated into a gold matrix. Composition and morphology of such composite films was characterized with x-ray photoelectron spectroscopy, scanning electron microscopy, and transmission electron microscopy (TEM) analysis. Carbon deposits on a gold magnetron sputter target and carbon impurities in the gold matrices of deposited films were observed while codepositing from gold and frozen toluene-CNP MAPLE targets in pure argon. Electrostatic quadrupole plasma analysis was used to determine that a likely mechanism for generation of carbon impurities was a reaction between toluene vapor generated from the MAPLE target and the argon plasma originating from the magnetron sputtering process. Carbon impurities of codeposited films were significantly reduced by introducing argon-oxygen mixtures into the deposition chamber; reactive oxygen species such as O and O+ effectively removed carbon contamination of gold matrix during the codeposition processes. Increasing the oxygen to argon ratio decreased the magnetron target sputter rate, and hence hybrid process optimization to prevent gold matrix contamination and maintain a high sputter yield is needed. High resolution TEM with energy dispersive spectrometry elemental mapping was used to study carbon distribution throughout the gold matrix as well as embedded CNP clusters. This research has demonstrated that a hybrid MAPLE and magnetron sputtering codeposition process is a viable means for synthesis of composite thin films from premanufactured nanoscale constituents, and that cross-process contaminations can be overcome with understanding of hybrid plasma process interaction mechanisms.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Using pulse shape analysis to improve the position resolution of a resistive anode microchannel plate detector

Digital signal processing techniques were employed to investigate the joint use of charge division and risetime analyses for the resistive anode (RA) coupled to a microchannel plate detector (MCP). In contrast to the typical approach of using the relative charge at each corner of the RA, this joint approach results in a significantly improved position resolution. A conventional charge division analysis utilizing analog signal processing provides a measured position resolution of 170 μm (FWHM). By using the correlation between risetime and position we were able to obtain a measured resolution of 92μm (FWHM), corresponding to an intrinsic resolution of 64μm (FWHM) for a single Z-stack MCP detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Tomographic Reconstruction of the Neutron Time-Energy Spectrum from a Dense Plasma Focus

A dense plasma focus (DPF) nuclear fusion generator is an attractive pulsed neutron source in many applications, due to its relatively large neutron yield, produced in a short time duration. In order to design a DPF that generates neutrons within a specified time profile, or generates a neutron energy spectrum with specific properties, it is necessary to understand and be able to fully characterize the results of the fusion process releasing the neutrons. The time-energy spectrum of fusion neutrons is an ideal quantity to use to validate multiphysics codes that simulate the pinch and fusion processes, because it is a quantity that requires the physics of each of the stages leading up to and ending in the fusion reaction to be simulated correctly. In particular, since DPF fusion neutrons are not monoenergetic – and there can often be several fusion pinches creating neutrons – a computer simulation matching high quality neutron spectrum measurements provides great confidence in the fidelity of the simulation. In order to make such a comparison, it is first necessary to have quality measurements from which to infer the spectrum. In this work we pose neutron spectroscopy as the classical tomographic inverse problem from neutron time of flight data at multiple distances, but enhanced by using detector pairs designed to reduce the scatter background and with an additional measurement of the time profile of the fusion pinch near its source. The detector pairs enhance the quality of the time of flight measurements and the additional constraint posed by the measured time profile allows for temporal resolution in the spectrum reconstruction that is equal to the measurement resolution, which can be subnanosecond, and energy resolution in the 10’s of keV, without the problem being underconstrained. We present results from a Deuterium-fueled DPF at the U.S. Department of Energy’s Nevada National Security Site and show that we can infer the time-energy spectrum from our measurements for both single and multi-pinch fusion reactions with equal fidelity.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A seamless acquisition digital storage oscilloscope with three-dimensional waveform display

In traditional digital storage oscilloscope (DSO), sampled data need to be processed after each acquisition. During data processing, the acquisition is stopped and oscilloscope is blind to the input signal. Thus, this duration is called dead time. With the rapid development of modern electronic systems, the effect of infrequent events becomes significant. To capture these occasional events in shorter time, dead time in traditional DSO that causes the loss of measured signal needs to be reduced or even eliminated. In this paper, a seamless acquisition oscilloscope without dead time is proposed. In this oscilloscope, three-dimensional waveform mapping (TWM) technique, which converts sampled data to displayed waveform, is proposed. With this technique, not only the process speed is improved, but also the probability information of waveform is displayed with different brightness. Thus, a three-dimensional waveform is shown to the user. To reduce processing time further, parallel TWM which processes several sampled points simultaneously, and dual-port random access memory based pipelining technique which can process one sampling point in one clock period are proposed. Furthermore, two DDR3 (Double-Data-Rate Three Synchronous Dynamic Random Access Memory) are used for storing sampled data alternately, thus the acquisition can continue during data processing. Therefore, the dead time of DSO is eliminated. In addition, a double-pulse test method is adopted to test the waveform capturing rate (WCR) of the oscilloscope and a combined pulse test method is employed to evaluate the oscilloscope's capture ability comprehensively. The experiment results show that the WCR of the designed oscilloscope is 6 250 000 wfms/s (waveforms per second), the highest value in all existing oscilloscopes. The testing results also prove that there is no dead time in our oscilloscope, thus realizing the seamless acquisition.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Unravelling the radiation-induced redox chemistry of plutonium ions in aqueous solution

Plutonium plays a critical role in nuclear fuel cycle technologies, but our understanding of its fundamental radiation-induced redox chemistry is limited. Changes in oxidation states affect the speciation and transport of plutonium ions in solution. For example, solvent extraction techniques used to separate and recover plutonium from used nuclear fuel rely on the selective formation, maintenance, and complexation of specific plutonium oxidation states. However, radiolytically generated radicals, ions, and molecules can drive the oxidation state distribution of plutonium ions far from equilibrium, ultimately changing the physical and chemical properties of the bulk system. These radiation-induced processes are inevitable due to the ionizing radiation fields generated by the radioactive decay of plutonium and its daughter nuclides. Therefore, mechanistically understanding how plutonium's various oxidation states respond to ionizing radiation is essential for predicting its behavior in solution. Here, we present significant advances in our understanding of radiation-induced plutonium redox chemistry by using time-resolved (electron pulse) and dose accumulation (alpha and gamma) irradiation techniques, along with quantitative multiscale modeling methods.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Calculation of the cross and auto power spectral densities for low neutron counting from pulse mode detectors

Here, this report introduces a methodology to calculate the prompt neutron decay constant of a subcritical assembly from the cross and auto power spectral densities of detectors operating in pulse mode when the neutron counting is low. The pulse operation mode allows the easy discrimination of the gamma contribution to the detector signal by the pulse height or shape techniques. The methodology is based on a MATLAB script that allows to change arbitrary parameters at any time after the experiment is performed. This technique requires list mode data and is much more flexible than programming the digital acquisition system because in the latter case the arbitrary parameters are set prior to the experiment and cannot be changed any longer after the experiment is performed. The MATLAB script processes all the detectors timestamps from several thousand pulses of the particle accelerator and redistributes them into a time interval that spreads over only 10 particle accelerator pulses. This pulses collapsing procedure has been performed because of the low neutron counting.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Computational and experimental characterization of high-brightness beams for femtosecond electron imaging and spectroscopy

Using a multilevel fast multipole method, coupled with the shadow imaging of femtosecond photoelectron pulses for validation, we quantitatively elucidate the photocathode, space charge, and virtual cathode physics, which fundamentally limit the spatiotemporal and spectroscopic resolution and throughput of ultrafast electron microscope (UEM) systems. We present a simple microscopic description to capture the nonlinear beam dynamics based on a two-fluid picture and elucidate an unexpected dominant role of image potential pinning in accelerating the emittance growth process. These calculations set theoretical limits on the performance of UEM systems and provide useful guides for photocathode design for high-brightness electron beam systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simulations of radiation damage as a function of the temporal pulse profile in femtosecond X-ray protein crystallography

Serial femtosecond X-ray crystallography of protein nanocrystals using ultrashort and intense pulses from an X-ray free-electron laser has proved to be a successful method for structural determination. However, due to significant variations in diffraction pattern quality from pulse to pulse only a fraction of the collected frames can be used. Experimentally, the X-ray temporal pulse profile is not known and can vary with every shot. This simulation study describes how the pulse shape affects the damage dynamics, which ultimately affects the biological interpretation of electron density. The instantaneously detected signal varies during the pulse exposure due to the pulse properties, as well as the structural and electronic changes in the sample. Here ionization and atomic motion are simulated using a radiation transfer plasma code. Pulses with parameters typical for X-ray free-electron lasers are considered: pulse energies ranging from 10 4 to 10 7 J cm -2 with photon energies from 2 to 12 keV, up to 100 fs long. Radiation damage in the form of sample heating that will lead to a loss of crystalline periodicity and changes in scattering factor due to electronic reconfigurations of ionized atoms are considered here. The simulations show differences in the dynamics of the radiation damage processes for different temporal pulse profiles and intensities, where ionization or atomic motion could be predominant. Overall, the different dynamics influence the recorded diffracted signal in any given resolution and will affect the subsequent structure determination.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Fast-Neutron Multiplicity Counter for the Detection of Diversion Scenarios

We demonstrated the application of a fast-neutron multiplicity counter (FNMC) to detect small variations in an assembly of uranium-oxide pins. The current version of the FNMC includes eight liquid organic scintillators (EJ-309 7.62 cm diameter x 7.62 cm) and eight crystal organic scintillators (stilbene 5.08 cm diameter x 5.08 cm) in a checkerboard assembly. We measured time-correlated fast neutrons, emitted by an assembly of 32 uranium-oxide pins, using two AmLi sources to induce fissions in the sample. Each pin is a cylinder of approximately 1 cm diameter and 10 cm length, with a mass of 75.52 g and 16.37 wt% enrichment. We removed up to 16 pins from a sample consisting of 32 pins, and determined the minimum number of pins that resulted in a statistically significant decrease of neutron coincidence counts. All the measurements were performed at the Zero Power Physics Reactor facility of Idaho National Laboratory. We found that a diversion of the four innermost pins could be detected by the system in 5 minutes. The detection of time-correlated neutrons requires their discrimination from gamma-ray events. This is an especially challenging task when measuring uranium isotopes, because of the intense gamma-ray flux generated by the radioactive decay of uranium daughters. We will describe the on-board pulse shape discrimination and post processing techniques that we applied to effectively distinguish neutrons from gamma-rays. Fast-neutron measurements have several potential advantages compared to thermal and epithermal neutron counters, the most important being a shorter die-away time and therefore reduced spurious coincidences due to accidental counts. This advantage may result in a higher sensitivity in timely detecting diversion of nuclear material from peaceful uses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Lidar Mapping and Surveillance of Nuclear Infrastructure

Wear is unavoidable, whether it occurs in a nuclear facility or abridge on the highway its detection is crucial to preventing the failure of a system. While tools capable of detecting localized damage exist, industry lacks methods to evaluate the health of larger infrastructure. Routine inspection of nuclear facilities must be undertaken to ensure the safety of personnel and proper containment of nuclear materials. Most systems in a nuclear facility are designated as radioactive and confined spaces. To constantly monitor such systems in person would be hazardous but with a remote inspection tool it can be done in a safer and easier way. Lidar: Operates by emitting a laser pulse and looking for the reflected light. Allows user to gain 3D information of the environment. Project Objective: To develop an inspection tool for evaluating the health of large scale infrastructure using Lidar and machine learning. Autonomous Platform + Lidar + Data Fusion + Big Data. Use SLAM to build a 2D map of the environment. Point cloud created by transforming the points between reference frames. Point cloud to Surface: Inherent representation of surface geometry; Difficult to process with conventional techniques. Point cloud to Image: Easily processed by conventional machine learning algorithms. The quantity of data generated will necessitate a big data framework to manage the data for processing. Additional Sensors: Detecting the temperature (a) chemical makeup (b) and radiation emission (c) of a surface could assist in detecting problems. Human inspection can detect irregularities in both physical objects and their point-cloud representations. This is a good indication that mapping nuclear sites using Lidar will provide qualitative insight into the health of the facility. If deep learning can be used to automatically identify problem areas then the completed tool could become an invaluable asset.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Process-driven roadmap for depositing super duplex stainless steel via wire Arc additive manufacturing

Here, this study systematically investigates the effects of shielding gas, bead spacing, weld mode, and travel speed on the phase balance, porosity, and hardness of wire arc additively manufactured (WAAM) super duplex stainless steel (ER2594). Robotic WAAM was employed to fabricate multilayer walls under systematically varied process conditions, followed by phase transformation simulations, X-ray computed tomography (XCT), electron backscatter diffraction (EBSD), and microhardness evaluation. Thermodynamic simulations predicted rapid cooling of AM process can suppress the potential formation of deleterious precipitates which was later validated via cross-sectional microstructure analyses of printed samples. XCT revealed porosity levels below 0.2% for all deposits, with reduced travel speed significantly lowering defect volume. Microstructural analyses revealed the evolution of various austenite precipitates, including grain boundary austenite (GBA), Widmanstätten austenite (WA), and intergranular austenite (IGA), sequentially upon cooling of the ferrite phase. Among all process parameters, weld transfer mode exhibited the strongest influence on phase balance; pulsed mode promoted higher ferrite retention (~ 36%) compared to RapidX mode. No consistent relationship between stabilized phase fraction and captured microhardness was observed. This work provides critical insights for optimizing WAAM parameters to control phase balance and mechanical performance, which is essential for producing high-integrity super duplex stainless-steel components for nuclear and marine applications.

Grain orientation↗