Search NASA⌕ Search

SEARCH · Search NASA

Results for “optical Interferometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Gas Sensors Based on Single-Arm Waveguide Interferometers

Various optical technologies can be implemented in chemical sensing. Sensitive, rugged, and compact systems will be more likely built using interferometric waveguide sensors. Currently existing sensors comprise dual-arm systems with external reference arm, dual-arm devices with internal reference arm such as integrated Mach-Zehnder interferometer, and single-arm systems which employ the interference between different waveguide modes. These latter ones are the most compact and rugged but still sensitive enough to monitor volatile pollutants such as NH3 coming out of industrial refrigerators and fertilizer plants and stocks, NO, NO2, SO2, emitted by industrial burning processes. Single-arm devices in planar waveguide configuration most frequently use two orthogonally polarized modes TE (sub i) and TM (sub i) of the same order i. Sensing effect is based on the difference in propagation conditions for the modes caused by the environment. However, dual-mode single-order interferometers still have relatively low sensitivity with respect to the environment related changes in the waveguide core because of small difference between propagation constants of TE (sub i) and TM (sub i) modes of the same order. Substantial sensitivity improvement without significant complication can be achieved for planar waveguide interferometers using modes of different orders with much greater difference between propagation constants.

Sarkisov, Sergey↗

Elimination of drift in a fiber-Bragg-grating-based multiplexed Michelson interferometer measurement system

Random phase drift in single-mode optical fiber interferometers used with measurement systems, which is resulted from various types of environmental disturbances, should be eliminated in order to obtain high measurement precision. We propose an optical fiber interferometric measurement system which has the function of self-eliminating the random phase drift and is stable and robust enough for real-time precision measurement. By employing the characteristics of fiber Bragg gratings, the system interleaves two fiber Michelson interferometers together that share the common-interferometric-optical path. The signal of one of the interferometers is used to stabilize the system while the signal of the other interferometer is used for measurement. An electronic feedback loop for the stabilizing action is designed. The bandwidth of the feedback loop is 5 kHz, sufficiently wide to eliminate random phase drift resulted from various environmental disturbances. The system is endowed with high stability and therefore suitable for real-time precision measurement. By means of an active phase tracking technique to measure displacement, the linear regression coefficient of the displacement measurement results is 0.9998.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spatial interferometry for white light processing: The coherence interferometer

An optical systems design approach for a parallel optical processor that has an information throughput capacity in excess of one petabit per second is discussed. This system enables predetection processing of white light, passively illuminated scenes. Integrated with a programmable Van der Lugt filter, this system is an effective data compression method. A program to implement this parallel optical processing by interferometry system is discussed.

Breckinridge, J. B.↗

Optical diameters of stars measured with the Mt. Wilson Mark III interferometer

Reliable stellar angular diameters can now be determined using the Mark III Optical Interferometer located on Mt. Wilson, California. The Mark III is a Michelson Interferometer capable of measuring the interferometric fringe visibility for stars using interferometer baselines varying from 3 to 31.5 meters in length. Angular diameters measured with the Mark III Optical Interferometer are presented for 12 stars at wavelengths of 450 and 800 nm.

Simon, R. S.↗

Interferometer for Measuring Displacement to Within 20 pm

An optical heterodyne interferometer that can be used to measure linear displacements with an error <=20 pm has been developed. The remarkable accuracy of this interferometer is achieved through a design that includes (1) a wavefront split that reduces (relative to amplitude splits used in other interferometers) self interference and (2) a common-optical-path configuration that affords common-mode cancellation of the interference effects of thermal-expansion changes in optical-path lengths. The most popular method of displacement- measuring interferometry involves two beams, the polarizations of which are meant to be kept orthogonal upstream of the final interference location, where the difference between the phases of the two beams is measured. Polarization leakages (deviations from the desired perfect orthogonality) contaminate the phase measurement with periodic nonlinear errors. In commercial interferometers, these phase-measurement errors result in displacement errors in the approximate range of 1 to 10 nm. Moreover, because prior interferometers lack compensation for thermal-expansion changes in optical-path lengths, they are subject to additional displacement errors characterized by a temperature sensitivity of about 100 nm/K. Because the present interferometer does not utilize polarization in the separation and combination of the two interfering beams and because of the common-mode cancellation of thermal-expansion effects, the periodic nonlinear errors and the sensitivity to temperature changes are much smaller than in other interferometers

Zhao, Feng↗

A scanning, all-fiber Sagnac interferometer for high resolution magneto-optic measurements at 820 nm

The Sagnac Interferometer has historically been used for detecting non-reciprocal phenomena, such as rotation. We demonstrate an apparatus in which this technique is employed for high resolution measurements of the Magneto-Optical Polar Kerr effect—a direct indicator of magnetism. Previous designs have incorporated free-space components which are bulky and difficult to align. We improve upon this technique by using all fiber-optic coupled components and demonstrate operation at a new wavelength, 820 nm, with which we can achieve better than 1 μrad resolution. Mounting the system on a piezo-electric scanner allows us to acquire diffraction limited images with 1.5 μm spatial resolution. We also provide extensive discussion on the details and of the Sagnac Interferometer's construction.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Rigid lightweight optical bench for a spaceborne FUV spatial heterodyne interferometer

Requirements for spaceflight optical instruments usually dictate that for the structures be rigid, lightweight, and thermally stable. In addition, for interferometric far ultraviolet (FUV) spectrometers, the requirements for torsional deflection are more severe than with conventional spectrometers. To meet the challenge for rigid and lightweight optical instruments, this paper explores the design of a high-stiffness structure for the support of an FUV spatial heterodyne interferometer where the torsional deflection of the instrument is on the order of 10 arc seconds. The structure is based on use of a thin, hollow section beam with weight-relieving between optical elements. The design also uses a modular and self-contained positioning mechanism that is removed after final optical alignment. Several specific material properties are presented as criteria for material selection. The parameters which affect the particular design requirements are identified with respect to the desired material properties and physical design features. Although large thin sections are susceptible to thermal gradients, this could be minimized by a trade-off for weight, where adequate margin exists. This paper describes the preliminary design for the structure and presents an analysis to verify compliance with the requirements.

Tom, James L.↗

Double-exposure holographic interferometer

Expensive optical-grade components in holographic interferometer are replaced with plastic test section and large-aperture spherical mirror to reduce distortions introduced by imperfections and cylindrical shape of plastic. Instrument is used for shock-tube gas density studies and is adaptable to wind-tunnel studies of vehicle windshields and other testing.

Livingston, F. R.↗

Features of correlation measurements of the parameters of pulsed hyperspectral optical fields using an asymmetric interferometer

Differences in correlation measurements of the parameters of pulsed hyperspectral optical fields using symmetric and asymmetric interferometers are considered. It is shown analytically that the resulting cross-correlation function is sensitive to phase perturbations in the original wave field. The considered setup, which contains a telescopic reflective 4f system of parabolic mirrors in one arm, demonstrates that in the case of an asymmetric interferometer, the presence of aberrations leads to degradation of the reconstructed image, whereas in the case of symmetric interferometers these aberrations do not affect the result. (paper)

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

GALILEO: Galactic Axion Laser Interferometer Leveraging Electro-Optics

We propose a novel experimental method for probing light dark matter candidates. We show that an electro-optical material’s refractive index is modified in the presence of a coherently oscillating dark matter background. A high-precision resonant Michelson interferometer can be used to read out this signal. The proposed detection scheme allows for the exploration of an uncharted parameter space of dark matter candidates over a wide range of masses—including masses exceeding a few tens of microelectronvolts, which is a challenging parameter space for microwave cavity haloscopes. Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A fiber-coupled heterodyne interferometric displacement sensor

Space-based interferometers and large segmented reflectors will require precision metrology with nanometer accuracy for active control systems. This paper summarizes an experimental study of an optical heterodyne interferometer with resolution of about 3 nm. Optical signals are carried to and from the interferometer by optical fibers to avoid thermally loading the reflector panels. Heterodyne detection provides far greater precision than does traditional interferometry.

Nerheim, Noble↗

Machine-learning-based automatic small-angle measurement between planar surfaces in interferometer images: A 2D multilayer Laue lenses case

Here, we report a new machine-learning-based approach to automatically measure the small angle between multiple planar surfaces characterized by white light interferometers. By applying an unsupervised clustering algorithm, DBSCAN (Density-Based Spatial Clustering of Applications with Noise), the multiple surfaces in an interferometer image are automatically identified as distinct surfaces. The angles between every two surfaces are then calculated through the surface fitting. This method can be applied to multiple surfaces regardless of their shapes and locations and significantly simplifies the angle measurement procedure. Using the developed method, we have demonstrated a quick and precise angle measurement for the alignment of 2D Multilayer Laue Lenses (MLLs) for the development of high-resolution x-ray microscopy. This automatic, accurate, and robust small-angle measurement method is compatible with widely used white light interferometers and can be further applied to other metrology applications of interferometer results.

36 MATERIALS SCIENCE↗

Wide Angle Michelson Doppler Imaging Interferometer (WAMDII)

The wide angle Michelson Doppler imaging interferometer (WAMDII) is a specialized type of optical Michelson interferometer working at sufficiently long path difference to measure Doppler shifts and to infer Doppler line widths of naturally occurring upper atmospheric Gaussian line emissions. The instrument is intended to measure vertical profiles of atmospheric winds and temperatures within the altitude range of 85 km to 300 km. The WAMDII consists of a Michelson interferometer followed by a camera lens and an 85 x 106 charge coupled device photodiode array. Narrow band filters in a filter wheel are used to isolate individual line emissions and the lens forms an image of the emitting region on the charge coupled device array.

Roberts, W. T.↗

Wide Angle Michelson Doppler Imaging Interferometer (WAMDII)

The wide angle Michelson Doppler imaging interferometer (WAMDII) is a specialized type of optical Michelson interferometer working at sufficiently long path difference to measure Doppler shifts and to infer Doppler line widths of naturally occurring upper atmospheric Gaussian line emissions. The instrument is intended to measure vertical profiles of atmospheric winds and temperatures within the altitude range of 85 km to 300 km. The WAMDII consists of a Michelson interferometer followed by a camera lens and an 85 x 106 charge coupled device photodiode array. Narrow band filters in a filter wheel are used to isolate individual line emissions and the lens forms an image of the emitting region on the charge coupled device array.

Roberts, B.↗

Proposal for a Mesoscopic Optical Berry-Phase Interferometer

We propose a novel spin-optronic device based on the interference of polaritonic waves traveling in opposite directions and gaining topological Berry phase. It is governed by the ratio of the TE-TM and Zeeman splittings, which can be used to control the output intensity. Because of the peculiar orientation of the TE-TM effective magnetic field for polaritons, there is no analogue of the Aharonov-Casher phase shift existing for electrons.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗