Improving the NIO Heliostat Field Optical Error Characterization Method and Tools
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Uniform shuttle-like Ln{sup 3+} (Eu{sup 3+}, Tb{sup 3+}) doped NaLa(WO{sub 4}){sub 2} nanocrystals have been solvothermally synthesized, and the size of the nanocrystals could be easily controlled by adjusting the volume ratio of ethylene glycol (EG) to water. Doped with 5 mol% Eu{sup 3+} and Tb{sup 3+} ions, the NaLa(WO{sub 4}){sub 2} nanocrystals showed strong red and green emissions with lifetimes of 0.8 and 1.40 ms, respectively. A high quenching concentration of 15 mol% was observed in Eu{sup 3+}-doped NaLa(WO{sub 4}){sub 2} nanocrystals and 35 mol% in Tb{sup 3+}-doped NaLa(WO{sub 4}){sub 2} nanocrystals. The emission intensity measurements of Eu{sup 3+}-doped NaLa(WO{sub 4}){sub 2} with different sizes indicated that the emission intensity of shuttles with length of 300 nm in average was stronger than that of shuttles with length of 900 nm in average, but was weaker than that of needles with length of 4 and 9 {mu}m in average. - Graphical abstract: Uniform shuttle-like Ln{sup 3+}(Eu{sup 3+}, Tb{sup 3+}) doped NaLa(WO{sub 4}){sub 2} nanocrystals have been solvothermally synthesized in the mixed solvent of ethylene glycol (EG) and water at 180 deg. C for 16 h.
The Broadband Reflector Experiment for Axion Detection is a dish antenna experiment probing the axion and dark photon parameter space in the [1 μeV, 1 eV] mass range, or [.02, 200] THz frequency range. In the pilot design for the InfraBREAD model, the dish antenna includes an optically smooth coaxial parabolic reflector to focus incoming photons in the near Infrared spectrum, created by the spontaneous photoconversion of axions and dark photons, onto a Superconducting Nanowire Single Photon Detector at the focus point of the reflector. As the pilot begins as a dark photon detector, sensitivity estimates hypothesize that it could cover unprobed parameter space in the search for the dark photon. Because of this, it is of critical importance that the reflector and SNSPD be placed at the correct points in the dish antenna, as previous work has shown that in addition to the focal spot of the photons being smeared to an area larger than the SNSPD, detection efficiency is s ensitive to shifts on the millimeter scale. In order to constrain this barrier to efficiency, the reflector had its focal spot, roughness, and length of surface waves measured by lasers in an optical bench setup. Results show the focal point diverging slightly from its theorized position in the antenna, while uncertainty in the height at which the detector should be placed was constrained to 10s of microns, the uncertainty in radial position could not be constrained to smaller than the detector given the methods used. Results for the roughness and surface wavelength show that the reflector was uniformly machined in a diamond-turning process used to fabricate optically smooth parts, as well as support a roughly 90% detection efficiency, reinforcing the sensitivity estimates presented.
Explore the source record for details and available documents.
Capabilities fact sheet for the National Center for Photovoltaics: Measurements and Characterization that includes scope, core competencies and capabilities, and contact/web information for Analytical Microscopy, Electro-Optical Characterization, Surface Analysis, and Cell and Module Performance.
Core-shell CdS/CdSe nanostructures have been synthesized by new microwave assisted ultrasonic sol gel route. The solution was obtained by dissolving cadmium acetate and Thiourea in the molar ratio 1:1 in Triethlioamine. The solution was Ultrasonically irradiated by Ultrasonic crystal at 40 Hz for 3 hours at 70°C. The sol was kept for another 24 hours for gel formation. Selenium dioxide was used as a selenium source and added separately. The gel was spin coated on Quartz and Glass slides followed by microwave heat treatment. The samples were characterized by structural morphological and optical characterization. XRD studies confirm the zinc blende phase of the CdS nanoparticles. The mean nanocrystal sizes calculated using Scherrer equation is ∼1.2nm. Optical studies show the strong blue shift in the spectra due to very small size of the nanocrystals. TEM and HRTEM confirm the formation of core shell structures.
RW Aur is a multiple T Tauri system consisting of an early-K type primary (A) and a K5 companion (B) at a separation of 1.''4. RW Aur A drives a bipolar optical jet that is well characterized optically. We present results of a sensitive Chandra observation whose primary objective was to search for evidence of soft extended X-ray emission along the jet, as has been seen for a few other nearby T Tauri stars. The binary is clearly resolved by Chandra and both stars are detected as X-ray sources. The X-ray spectra of both stars reveal evidence for cool and hot plasma. Surprisingly, the X-ray luminosity of the less-massive secondary is at least twice that of the primary and is variable. The disparity is attributed to the primary whose X-ray luminosity is at the low end of the range for classical T Tauri stars of similar mass based on established correlations. Deconvolved soft-band images show evidence for slight outward elongation of the source structure of RW Aur A along the blueshifted jet axis inside the central arcsecond. In addition, a faint X-ray emission peak is present on the redshifted axis at an offset of 1.''2 ± 0.''2 from the star. Deprojected jet speeds determined from previous optical studies are too low to explain this faint emission peak as shock-heated jet plasma. Thus, unless flow speeds in the redshifted jet have been underestimated, other mechanisms such as magnetic jet heating may be involved.
The use of steady-state photoluminescence spectroscopy as a contactless characterization tool, suitable for inline optical characterization, has been previously demonstrated for high efficiency solar cells such as GaAs. In this paper, we demonstrate the use of PLE characterization on a thin film CdS/CdTe np heterojunction solar cell, and compare the results to measured EQE and I-V data. In contrast to previous work on high-quality GaAs, the PLE and EQE spectra do not match closely here. We still find, however, that reliable material parameters can be extracted from the PLE measurements. We also provide a physical explanation of the limits defining the cases when the PLE and EQE spectra may be expected to match.
A concept is presented for a national cryogenic optics test facility capable of optical characterization of 1.25 m diameter optics having focal lengths up to 6.2 m at temperatures from 300 K to near 4 K. The facility will be comprised of a large Dewar with a phase shift interferometer, a two stage vacuum system employing a turbomolecular pump, and an integral vibration isolation system. The entire facility will be housed in a concrete site with a massive floor to assist in reducing vibration during optical tests. By providing interchangeable sections, the overall height of the Dewar can be adjusted to provide for testing of shorter focal length optics. The background for the facility is discussed along with the facility location, and the requirements and the performance considerations which drive the Dewar design with respect to the vibration isolation system, vacuum system, and optical interferometry.
A concept is presented for a national cryogenic optics test facility capable of optical characterization of 1.25 m diameter optics having focal lengths up to 6.2 m at temperatures from 300 K to near 4 K. The facility will be comprised of a large Dewar with a phase shift interferometer, a two-stage vacuum system employing a turbomolecular pump, and an integral vibration isolation system. The entire facility will be housed in a concrete site with a massive floor to assist in reducing vibration during optical tests. By providing interchangeable sections, the overall height of the Dewar can be adjusted to provide for testing of shorter focal length optics. The background for the facility is discussed along with the facility location, and the requirements and the performance considerations which drive the Dewar design with respect to the vibration isolation system, vacuum system, and optical interferometry.
Purpose: Magnetic resonance-guided laser-induced thermal therapy (MRgLITT) is investigated as a neurosurgical intervention for oncological applications throughout the body by active post market studies. Real-time MR temperature imaging is used to monitor ablative thermal delivery in the clinic. Additionally, brain MRgLITT could improve through effective planning for laser fiber's placement. Mathematical bioheat models have been extensively investigated but require reliable patient specific physical parameter data, e.g. optical parameters. This abstract applies an inverse problem algorithm to characterize optical parameter data obtained from previous MRgLITT interventions. Methods: The implemented inverse problem has three primary components: a parameter-space search algorithm, a physics model, and training data. First, the parameter-space search algorithm uses a gradient-based quasi-Newton method to optimize the effective optical attenuation coefficient, μ-eff. A parameter reduction reduces the amount of optical parameter-space the algorithm must search. Second, the physics model is a simplified bioheat model for homogeneous tissue where closed-form Green's functions represent the exact solution. Third, the training data was temperature imaging data from 23 MRgLITT oncological brain ablations (980 nm wavelength) from seven different patients. Results: To three significant figures, the descriptive statistics for μ-eff were 1470 m{sup −1} mean, 1360 m{sup −1} median, 369 m{sup −1} standard deviation, 933 m{sup −1} minimum and 2260 m{sup −1} maximum. The standard deviation normalized by the mean was 25.0%. The inverse problem took <30 minutes to optimize all 23 datasets. Conclusion: As expected, the inferred average is biased by underlying physics model. However, the standard deviation normalized by the mean is smaller than literature values and indicates an increased precision in the characterization of the optical parameters needed to plan MRgLITT procedures. This investigation demonstrates the potential for the optimization and validation of more sophisticated bioheat models that incorporate the uncertainty of the data into the predictions, e.g. stochastic finite element methods.
Amorphous selenium (a-Se) and a-Se{sub 95}Sb{sub 5} alloy were prepared using melt quenching technique. X-ray diffraction (XRD) pattern confirmed the amorphous nature of the prepared samples. Composition of the prepared samples has been determined using Energy dispersive X-ray fluorescence (EDXRF) technique. Differential thermal analysis (DTA) confirmed the glassy nature of the prepared samples. Thin films of the prepared samples were deposited on glass substrate using thermal evaporation method. Amorphous nature of the deposited films was confirmed using XRD. Optical properties of these films were obtained from the UV-VIS transmission spectra, at normal incidence, over 200-1100 nm spectral range. The optical absorption edge was described by using the model given by the Tauc. Optical band gap of the deposited films was calculated using Tauc plot. Optical characterization showed that average transmission and optical band gap decreased with the addition of antinomy.
In present work, HfO{sub 2} thin films have been deposited at various oblique incidences on Si substrates by electron beam evaporation. These refractory oxide films exhibited anisotropy in refractive index predictably due to special columnar microstructure. Spectroscopic ellipsometry being a powerful tool for optical characterization has been employed to investigate optical anisotropy. It was observed that the film deposited at glancing angle (80°) exhibits the highest optical anisotropy. Further, anisotropy was noticed to decrease with lower values of deposition angles while effective refractive index depicts opposite trend. Variation in refractive index and anisotropy has been explained in light of atomic shadowing during growth of thin films at oblique angles.
The performance and integrity of photovoltaic (PV) modules and materials may be assessed through optical characterizations. We have developed a custom optical mapping instrument (OMI) to improve measurement throughput time, facilitate automated measurements, allow for localized specimen examination, obtain spatial information relative to commercial benchtop spectrophotometer instruments, and provide automated data analysis. Both the key components and the methods used to improve the measurements are described. The measurement precision for the OMI is benchmarked for hemispherical transmittance relative to a previous round-robin study for commercial spectrophotometers. In addition to the unique instrument developed in this study, new insights have emerged from the examination of specimens from previous experiments, including: the depletion of the UV absorber is revealed for specimens beyond a certain size after artificial ultraviolet (UV) weathering; an optical degradation by internal haze formation is confirmed following Damp Heat (85 °C/85% relative humidity) testing; the better uniformity of the wear pattern for falling sand abrasion is used to select the DIN 52348 fixture over the ASTM D968 fixture; and the greater local (in the order of millimeters) heterogeneity of surface contamination in the soiling-prone location of Dubai relative to Kuwait. The results of the UV study have already been used to improve the standardized weathering of encapsulants. The example for Damp Heat testing is given to increase awareness of a degradation believed to be ubiquitously occurring in safety and design-type qualification testing of PV modules.
Reflectivity control devices (RCDs) based on polymer dispersed liquid crystals were fabricated for Solar Cruiser, a SmallSat NASA Pathfinder Mission consisting of a 1653 square meter solar sail that would establish an artificial orbit sunward of the L1 Lagrange point for heliophysics observations. Here we describe the optical characterization of these birefringent electro-optic devices including thin film measurements and analysis, hyperspectral bidirectional reflectance distribution function measurements, and radiometric analysis. These measurements demonstrate the promise of RCDs for roll control and momentum management of solar sails.
Reflectivity control devices (RCDs) based on polymer dispersed liquid crystals were fabricated for Solar Cruiser, a SmallSat NASA Pathfinder Mission consisting of a 1653 square meter solar sail that would establish an artificial orbit sunward of the L1 Lagrange point for heliophysics observations. Here we describe the optical characterization of these birefringent electro-optic devices including thin film measurements and analysis, hyperspectral bidirectional reflectance distribution function measurements, and radiometric analysis. These measurements demonstrate the promise of RCDs for roll control and momentum management of solar sails.
Described herein are systems, devices, and methods facilitating optical characterization of scattering samples. A polarized optical beam can be directed to pass through a sample to be tested. The optical beam exiting the sample can then be analyzed to determine its degree of polarization, from which other properties of the sample can be determined. In some cases, an apparatus can include a source of an optical beam, an input polarizer, a sample, an output polarizer, and a photodetector. In some cases, a signal from a photodetector can be processed through attenuation, variable offset, and variable gain.
The performance and integrity of photovoltaic (PV) modules and materials may be assessed through optical characterizations. We have developed a custom Optical Mapping Instrument (OMI) to improve measurement throughput time, facilitate automated measurements, and obtain spatial information relative to commercial benchtop spectrophotometer instruments. Both the key components and the methods used to improve the measurements are described. The measurement precision for the OMI is benchmarked for hemispherical transmittance relative to a previous round-robin study for commercial spectrophotometers. Example mapping measurements and their implications are given for specimens from other studies, including: (1) the depletion of the UV absorber is revealed for specimens beyond a certain size after standardized artificial ultraviolet (UV) weathering, (2) an optical degradation by internal haze formation is confirmed following Damp Heat (85°C/85% relative humidity) testing, (3) the better uniformity of the wear pattern for falling sand abrasion is used to select the DIN 52348 fixture over the ASTM D968 fixture, and (4) the local (millimeter-scale) heterogeneity of surface contamination in the soiling-prone location of Dubai relative to Kuwait. The results of the UV study have already been used to improve the standardized weathering of encapsulants. The example for Damp Heat testing is given to increase awareness of a degradation believed to be ubiquitously occurring in safety and design-type qualification testing of PV modules.