Search NASA⌕ Search

SEARCH · Search NASA

Results for “optical materials”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Multi-Billion Shot, High-Fluence Exposure of Cr(4+): YAG Passive Q-Switch

NASA's Goddard Space Flight Center is developing the Geoscience Laser Altimeter System (GLAS) employing a diode pumped, Q-Switched, ND:YAG laser operating at 40 Hz repetition rate. To meet the five-year mission lifetime goal, a single transmitter would accumulate over 6.3 billion shots. Cr(4+):YAG is a promising candidate material for passively Q-switching the laser. Historically, the performance of saturable absorbers has degraded over long-duration usage. To measure the multi-billion shot performance of Cr(4+):YAG, a passively Q-switched GLAS-like oscillator was tested at an accelerated repetition rate of 500 Hz. The intracavity fluence was calculated to be approximately 2.5 J/cm(exp 2). The laser was monitored autonomously for 165 days. There was no evidence of change in the material optical properties during the 7.2 billion shot test.. All observed changes in laser operation could be attributed to pump laser diode aging. This is the first demonstration of multi-billion shot exposure testing of Cr(4+):YAG in this pulse energy regime

Stephen, Mark A.↗

Metrology Mount and Optics Mandrels

This document is the Final Report for NASA Grant NAG8-1198 from NASA Marshall Space Flight Center (MSFC) to the Smithsonian Astrophysical Observatory (SAO). The Grant is entitled "Metrology Mount and Optics Materials." This final report is required by the terms of the Grant. The period of performance was from September 15, 1995 through January 14, 1999. Total funding received by SAO from MSFC for this effort was, $254,000. Mr. Lester Cohen carried out most of the work at SAO, but received limited support from other engineers, technicians, and designers. Dr. Harvey Tananbaum, the Principal Investigator for the grant provided overall direction and work- assessment. The Grant has had two funding augmentations to its basic amount and has, over time, emphasized three different research areas - each of which has been an extension of earlier research. The research activity was in 2 areas: (1) Expert opto-structural studies related to separation mechanics and effects of electro formed nickel X-ray mirrors. and (2) Design, fabrication and evaluation of a low force metrology and assembly station for light weight full shell electroformed X-ray mirrors.

Tananbaum, H.↗

Panoramic Refracting Optic

An optical device having a semi-spherical or hemispherical field-of-view is provided. A conically-shaped piece of optical material has an annular surface satisfying Snell's Law for total internal reflection with respect to light passing through the piece and incident on the annular surface from within the piece.

Lindner, Jeffrey L.↗

Panoramic Refracting Conical Optic

An optical device having a semi-spherical or hemispherical field-of-view is provided. A conically-shaped piece of optical material has an annular surface satisfying Snell's Law for total internal reflection with respect to light passing through the piece and incident on the annular surface from within the piece.

Lindner, Jeffrey L.↗

The Development of Solar Sail Propulsion for NASA Science Missions to the Inner Solar System

This paper examines recent assessments of the technology challenges facing solar sails, identifies the systems and technologies needing development, and the approach employed by NASA's In-space Propulsion Program in NASA to achieve near term products that move this important technology from low technology readiness level (TRL) toward the goal of application to science missions in near earth space and beyond. The status of on-going efforts to design, build, and test ground demonstrators of alternate approaches to structures (inflatable versus rigid), membrane materials, optical shape sensing, and attitude control will be presented along with planned future investments.

Montgomery, Edward E, IV↗

Ionizing radiation exposure of LDEF (pre-recovery estimates)

The long duration exposure facility (LDEF), launched into a 258 nautical mile orbit with an inclination of 28.5 degrees, remained in space for nearly 6 yr. The 21,500 lb NASA satellite was one of the largest payloads ever deployed by the Space Shuttle. LDEF completed 32,422 orbits and carried 57 major experiments representing more than 200 investigators from 33 private companies, 21 universities and nine countries. The experiments covered a wide range of disciplines including basic science, electronics, optics, materials, structures and power and propulsion. A number of the experiments were specifically designed to measure the radiation environment. These experiments are of specific interest, since the LDEF orbit is essentially the same as that of the Space Station Freedom. Consequently, the radiation measurements on LDEF will play a significant role in the design of radiation shielding of the space station. The contributions of the various authors presented here attempt to predict the major aspects of the radiation exposure received by the various LDEF experiments and therefore should be helpful to investigators who are in the process of analyzing experiments which may have been affected by exposure to ionizing radiation. The paper discusses the various types and sources of ionizing radiation including cosmic rays, trapped particles (both protons and electrons) and secondary particles (including neutrons, spallation products and high-LET recoils), as well as doses and LET spectra as a function of shielding. Projections of the induced radioactivity of LDEF are also discussed.

Flight Experiment↗

The Cryogenic, High-Accuracy, Refraction Measuring System (CHARMS): A New Facility for Cryogenic Infrared through Vacuum Far-Ultraviolet Refractive Index Measurements

The optical designs of future NASA infrared (IR) missions and instruments, such as the James Webb Space Telescope's (JWST) Near-Mixed Camera (NIRCam), will rely on accurate knowledge of the index of refraction of various IR optical materials at cryogenic temperatures. To meet this need, we have developed a Cryogenic, High-Accuracy Refraction Measuring System (CHARMS). In this paper we discuss the completion of the design and construction of CHARMS as well as the engineering details that constrained the final design and hardware implementation. In addition, we will present our first light, cryogenic, IR index of refraction data for LiF, BaF2, and CaF2, and compare our results to previously published data for these materials.

Frey, Bradley J.↗

Cryogenic Performance of a Lightweight Silicon Carbide Mirror

Low cost, high performance lightweight Silicon Carbide (SiC) mirrors provide an alternative to Beryllium mirrors. A Trex Enterprises 0.25m diameter lightweight SiC mirror using its patented Chemical Vapor Composites (CVC) technology was evaluated for its optical performance. CVC SiC is chemically pure, thermally stable, and mechanically stiff. CVC technology yields higher growth rate than that of CVD SiC. NASA has funded lightweight optical materials technology development efforts involving SiC mirrors for future space based telescope programs. As part of these efforts, a Trex SiC was measured interferometrically from room temperature to 30 degrees Kelvin. This paper will discuss the test goals, the test instrumentation, test results, and lessons learned.

Eng, Ron↗

Cryogenic Performance of Trex SiC Mirror

Low cost, high performance lightweight Silicon Carbide (Sic) mirrors provide an alternative to Beryllium mirrors. A Trex Enterprises 0.25m diameter lightweight Sic mirror using its patented Chemical Vapor Composites (CVC) technology was evaluated for its optical performance. CVC Sic is chemically pure, thermally stable, and mechanically stiff. CVC technology yields higher growth rate than that of CVD Sic. NASA has funded lightweight optical materials technology development efforts involving Sic mirrors for future space based telescope programs. As part of these efforts, a Trex Sic was measured interferometrically from room temperature to 30 degrees Kelvin. This paper will discuss the test goals, the test instrumentation, test results, and lessons learned.

Foss, Colby↗

Electro-optic Q-switch

An electro-optic Q-switch for generating sequence of laser pulses was disclosed. The Q-switch comprises a quadratic electro-optic material and is connected with an electronic unit generating a radio frequency wave with positive and negative pulses alternatively. The Q-switch is controlled by the radio frequency wave in such a way that laser pulse is generated when the radio frequency wave changes its polarity.

Zou, Yingyin↗

Rarefying Spectra of Whispering-Gallery-Mode Resonators

A method of cleaning the mode spectra of whispering-gallery-mode (WGM) optical resonators has been devised to make such resonators more suitable for use as narrow-band optical filters. The method applies, more specifically, to millimeter- sized whispering-gallery-mode optical resonators that are made of crystalline electro-optical materials and have ultrahigh values of the resonance quality factor (Q). The mode spectrum of such a resonator is typically dense, consisting of closely spaced families of modes; as such, the spectrum is not well suited for narrow-band filtering, in which there is a need for strong rejection of side modes. Cleaning as used here signifies rarefying the spectrum so that what remains consists mostly of a single desired family of modes or, at worst, a few mode families that are more widely spaced in frequency than are the mode families in the original, non-rarefied spectrum. The spectrum-cleaning method exploits the fact that various WGM mode families occupy various positions near the equator at the rim of a resonator disk. In this method, a damper in the form of a prism or other polished piece of material having an index of refraction greater than that of the resonator material is placed in contact with the rim of the resonator at such a position that the Qs of most or all of the undesired mode families are greatly reduced while the Q of the desired mode family is reduced by only a tolerably small amount. In an alternative method that has been considered, the mode spectrum would be cleaned through special design of the shape of the rim, but fabrication of the rim in a special shape is a complicated task. The advantage of the present method, relative to the alternative method, is that special shaping of the rim is not necessary and the damping prism can be emplaced after the resonator has been fabricated.

Savchenkov, Anatoliy↗

Temperature-Dependent Refractive Index of Cleartran® ZnS to Cryogenic Temperatures

First, let's talk about the CHARMS facility at NASA's Goddard Space Flight Center: Cryogenic, High-Accuracy Refraction Measuring System (CHARMS); design features for highest accuracy and precision; technologies we rely on; data products and examples; optical materials for which we've measured cryogenic refractive index.

Leviton, Doug↗

Measuring the Density, Viscosity, and Surface Tension of Molten Titanates Using Electrostatic Levitation in Microgravity

Rare earth and barium titanates are useful as ferroelectric, dielectric, and optical materials. Measurements of their thermophysical properties in the liquid state can help guide melt processing technologies for their manufacture and advance understanding of fragile liquids' behavior and glass formation. Here, we report the density, thermal expansion, viscosity, and surface tension of molten BaTiNsub>2 O 5 , BaTi 4 O 9 , and 83TiO 2 -17RE 2 O 3 (RE = La or Nd). Measurements were made using electrostatic levitation and droplet oscillation techniques in microgravity, which provide access to quiescent liquid droplets and deep supercooling of 510–815 K below the equilibrium melting points. Densities were measured over 900–2400 K. Viscosities were similar for all four compositions, increasing from ∼10 mPa s near 2100 K to ∼30 mPa s near 1750 K. Surface tensions were 450–490 dyn cm −1 for the rare earth titanates and 383–395 dyn cm−1 for the barium titanates; surface tensions of all compositions had small or negligible temperature dependence over 1700–2200 K. For solids recovered after melt quenching, x-ray microtomography revealed the fracture mechanics in crystalline products and minimal internal porosity in glass products, likely arising from entrapped gas bubbles. Internal microstructures were generally similar for products processed either in microgravity or in a terrestrial aerodynamic levitator.

Stephen K Wilke↗

Materials requirements for optical processing and computing devices

Devices for optical processing and computing systems are discussed, with emphasis on the materials requirements imposed by functional constraints. Generalized optical processing and computing systems are described in order to identify principal categories of requisite components for complete system implementation. Three principal device categories are selected for analysis in some detail: spatial light modulators, volume holographic optical elements, and bistable optical devices. The implications for optical processing and computing systems of the materials requirements identified for these device categories are described, and directions for future research are proposed.

Tanguay, A. R., Jr.↗

Learning From Failure: Boosting Cycling Endurance of Optical Phase Change Materials

Chalcogenide phase change materials (PCMs) are a unique class of compounds whose switchable optical and electronic properties have fueled an explosion of emerging applications in microelectronics and microphotonics. Key to any application is the ability of PCMs to reliably switch between crystalline and amorphous states over a large number of cycles. While this issue has been extensively studied in the case of microelectronic memories, current PCM-based optical devices suffer from much inferior endurance. To understand the failure mechanisms limiting endurance of PCMs specifically in microphotonic devices, we have developed an on-chip resistive micro-heater platform and an automatic multi-modal characterization system to analyze cycling performance of optical PCMs. Reversible switching of large-area PCM devices over 50,000 cycles was demonstrated.

Optical phase change material↗

Triboluminescent Materials for Smart Optical Damage Sensors for Space Applications

Triboluminescence is light that is produced by pressure, friction or mechanical shock. New composite materials are constantly being reengi neered in an effort to make lightweight spacecrafts for various NASA missions. For these materials there is interest in monitoring the con dition of the composite in real time to detect any delamination or cr acking due to damage, fatigue or external forces. Methods of periodic inspection of composite structures for mechanical damage such as ult rasonic testing are rather mature. However, there is a need to develop a new technique of damage detection for composites, which could dete ct cracking or delamination from any desired location within a materi al structure in real time. This could provide a valuable tool in the confident use of composite materials for various space applications. Recently, triboluminnescent materials have been proposed as smart sen sors of structural damage. To sense the damage, these materials can b e epoxy bonded or coated in a polymer matrix or embedded in a composi te host structure. When the damage or fracture takes place in the hos t structure, it will lead to the fracture of triboluminescent crystal s resulting in a light emission. This will warn, in real time, that a structural damage has occurred. The triboluminescent emission of the candidate phosphor has to be sufficiently bright, so that the light signal reaching from the point of fracture to the detector through a fiber optic cable is sufficiently strong to be detected. There are a large number of triboluminescent materials, but few satisfy the above criterion. Authors have synthesized a Eu based organic material know n as Europium tetrakis (dibenzoylmethide) triethylammonium .(EuD(sub 4)TEA), one of the bright triboluminescent materials, which is a pote ntial candidate for application as a damage sensor and could be made into a wireless sensor with the addition of microchip, antenna and el ectronics. Preliminary results on the synthesis and characterization of this material shall be presented.

Aggarwal, Mohan D.↗