Search NASA⌕ Search

SEARCH · Search NASA

Results for “optical spectrometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Cloud microstructure studies

Over two thousand individual cloud droplet size distributions were measured with an optical cloud particle spectrometer flown on the NASA Convair 990 aircraft. Representative droplet spectra and liquid water content, L (gm/cu m) were obtained for oceanic stratiform and cumuliform clouds. For non-precipitating clouds, values of L range from 0.1 gm/cu m to 0.5 gm/cu m; with precipitation, L is often greater than 1 gm/cu m. Measurements were also made in a newly formed contrail and in cirrus clouds.

Blau, H. H., Jr.↗

A sounding rocket spectroheliometer for photometric studies at extreme ultraviolet wavelengths

Construction and mode of operation are described for a sounding rocket spectroheliometer used to establish the sensitivity of the EUV spectroheliometer on the Skylab Apollo Telescope Mount (ATM). The sounding rocket instrument was calibrated immediately before and after two flights and the calibration was transferred when the rocket and ATM instruments simultaneously measured the average intensity emitted by a quiet area of the solar disk. Descriptions are presented for the payload assembly and flight sequence, the optical system (telescope, spectrometer, and pointing reference camera), the vacuum pumping system, and the instrument electronics. Results obtained from the two flights in August and December 1973 are discussed, which included unambiguous determinations of the absolute intensity emitted by a region of the quiet solar disk over the wavelength range from 1350 to 300 A on two separate occasions and the establishment of photometric accuracy to that of laboratory calibration procedures.

Timothy, J. G.↗

Compact Imaging Spectrometer

Imaging spectrometer for use in crop and mineral resource-mapping experiments is scaled-down version. Compact imaging spectrometer uses Schmidt/Littrow optics with single spherical primary mirror. Radiation from scene strikes reflecting Schmidt corrector plate located near center of curvature of primary spherical mirror.

Wellman, J. B.↗

Atmosphere monitoring requirements

Atmospheric monitoring needs and requirements associated with the use of the Mass Spectrometer Electro-Optical Ion Detector for space stations contamination studies are discussed. Instrument performance requirements and design specifications are examined. A general overview is presented of the types of chemical contaminants found in spacecraft environments.

Ruecker, M.↗

On the direct and dissociative excitation of the O(3s 3S0) state by electron impact on atomic and molecular oxygen

The ratio of the cross sections for the direct and dissociative excitation of the OI(3s 3S0-2p 3P; 1304 A wavelength) transition, sigma A/sigma D, are accurately determined, and the sigma A/sigma D ratio is directly normalized to the ratio of the O(+) and O2(+) ionization cross sections using a high-density diffuse gas source, an electrostatically focused electron gun, a vacuum-ultraviolet monochromater, and a quadrupole mass spectrometer for simultaneous optical and composition measurements. Using revised sigma A(1304 A) values calculated with new calibration standards, the shape of the cross section for the excitation of the O(3s 3S0) state agrees well with previous results, though the absolute magnitude of sigma A(1304 A) is smaller than the results of Stone and Zipf (1974) by a factor of 2.8. The revised cross sections agree well with recent quantum calculations when cascade excitation of the 3s 3S0 state is taken into account.

Zipf, E. C.↗

Preliminary Analysis Of Data From AVIRIS

Report presents preliminary analysis of performance of Airborne Visible/Infrared Imaging Spectrometer (AVIRIS), a scanning instrument producing images at wavelengths from 400 to 2,450 nm. Includes four spectrometers connected by optical fibers to common set of foreoptics. Focuses upon calibration of instrument and determination of reflectance of surface of Earth from its measurements.

Conel, James E.↗

Reanalysis of x ray emission from M87 II: Multiphase models

In a previous paper by the authors (hereafter TB), it was shown that the hot intracluster gas around M87 could not be adequately explained in terms of a spherically symmetric, single phase model. It was found that although data from the Einstein satellite High Resolution Imager (HRI), Imaging Proportional Counter (IPC), and Focal Point Crystal Spectrometer (FPCS) could indeed be simultaneously explained by a single phase model, data from the Solid State Spectrometer (SSS) and optically determined mass estimates could not be similarly explained. A qualitative discussion was then given to indicate how the adoption of a specific multiphase model could plausibly improve upon the single phase model, but a detailed discussion was delayed until now. The x ray data is reanalyzed for the gas around M87 in the same spirit as the work in TB. That is, by assuming several cooling flow models, the shortcomings are improved upon. The procedure of TB was adopted and the data reanalyzed in the following manner: a multiphase model is assumed which can compute the surface brightness as seen by HRI and IPC. Also, the line fluxes can be computed of the lines seen by the FPCS and the mass profile after assuming hydrostatic equilibrium. The parameters of the model are then adjusted to fit the data. A check is then made to see whether the resulting model is consistent with the SSS spectrum and the equivalent width of the 7 keV complex of Fe lines as seen by large field of view instruments.

Tsai, John C.↗

The chemical and radiative effects of the Mount Pinatubo eruption

To clarify the mechanisms leading to effects on stratospheric ozone, time-dependent stratospheric aerosol and gas experiment II (SAGE II) and cryogenic limb array elaton spectrometer (CLAES) aerosol optical extinction data and SAGE II surface area density are used as parameters in a two-dimensional (2-D) zonally averaged chemical radiative transport model. The model was integrated with time from before the eruption through December 1993. The modeled impact on global ozone results from increased rates of heterogeneous reactions on sulfate aerosols and from the increased radiative heating and scattering caused by these aerosols. When the aerosol heating is allowed to modify the temperature distribution, the maximum change calculated in equatorial column ozone is -1.6%. The calculated equatorial temperature change and peak local ozone change in October 1991 are +6K and -4%, respectively. When aerosol heating perturbs the circulation in the model, the maximum change in equatorial column ozone is -6%. Increased heterogeneous processing on sulfate aerosols is calculated to have changed equatorial column ozone in late 1991 by -1.5%. Global column ozone in the model in 1992 and 1993 changed by -2.8% and -2.4%, respectively. The relationship of ozone-controlling processes in the lower stratosphere is altered as well; HO(x) becomes the most important catalytic cycle, followed by ClO(x) and NO(x). This is driven by significant changes in trace gas concentrations. In October 1991, lower stratospheric, equatorial NO(x) decreased by 40%, ClO(x) increased by 60%, and HO(x) increased by 25%. When the effect of heterogeneous chemical processing on sulfate aerosols is combined with aerosol heating, modifying either circulation or temperature, dramatically different ozone fingerprints with time and latitude are predicted. Model-derived changes in the equatorial region in column ozone best represented the observed data when perturbed circulation was combined with heterogeneous chemical effects. However, at high latitudes, the increased ozone production from the strengthening of the mean circulation tends to cancel the heterogeneous reduction of ozone. This is not in good agreement with observed data, especially in 1992 and 1993. When the circulation is held fixed and the temperature allowed to change, and heterogeneous chemical effects are included, the equatorial ozone decrease predicted was too small for 1991. However, the mid- to high-latitude decrease in 1992 and 1993 is in better agreement with observed data.

Kinneson, Douglas E.↗

Construction of a Chemical Sensor/Instrumentation Package Using Fiber Optic and Miniaturization Technology

The objective of this research was to construct a chemical sensor/instrumentation package that was smaller in weight and volume than conventional instrumentation. This reduction in weight and volume is needed to assist in further reducing the cost of launching payloads into space. To accomplish this, fiber optic sensors, miniaturized spectrometers, and wireless modems were employed. The system was evaluated using iodine as a calibration analyte.

Newton, R. L.↗

MACS, An Instrument, and a Methodology for Simulations and Global Measurements of the Coronal Electron Temperature and the Solar Wind Velocity on the Solar Corona

The determination of the radial and latitudinal temperature and wind profiles of the solar corona is of great importance in understanding the coronal heating mechanism and the dynamics of coronal expansion. Cram presented the theory for the formation of the K-coronal spectrum and identified two important observations. He observed the existence of temperature sensitive anti-nodes at certain wavelengths in the theoretical K-coronal spectra. The anti-nodes are separated by temperature-insensitive nodes. Remarkably, Cram showed that the wavelengths of the nodes and anti-nodes are almost independent of altitude above the solar limb. Because of these features, Cram suggested that the intensity ratios at two anti-nodes could be used as a diagnostic of the electron temperature in the K-corona. Based on this temperature diagnostic technique prescribed by Cram a slit-based spectroscopic study was performed by Ichimoto et al. on the solar corona in conjunction with the total solar eclipse of 3 Nov 1994 in Putre, Chile to determine the temperature profile of the solar corona. In this thesis Cram's theory has been extended to incorporate the role of the solar wind in the formation of the K-corona, and we have identified both temperature and wind sensitive intensity ratios. The instrument, MACS, for Multi Aperture Coronal Spectrometer, a fiber optic based spectrograph, was designed for global and simultaneous measurement of the thermal electron temperature and the solar wind velocity in the solar corona. The first ever experiment of this nature was conducted in conjunction with the total solar eclipse of 11 Aug 1999 in Elazig, Turkey. In this instrument one end of each of twenty fiber optic tips were positioned in the focal plane of the telescope in such a way that we could observe conditions simultaneously at many different latitudes and two different radial distances in the solar corona. The other ends of the fibers were vertically aligned and placed at the primary focus of the collimating lens of the spectrograph to obtain simultaneous and global spectra on the solar corona. By isolating the K-coronal spectrum from the spectrum recorded by each fiber the temperature and the wind sensitive intensity ratios were calculated to obtain simultaneous and global measurements of the thermal electron temperature and the solar wind velocity. We were successful in obtaining reliable estimates of the coronal temperature at many positions in the corona. This is the first time that simultaneous measurements of coronal temperatures have been obtained at so many points. However due to instrumental scattering encountered during observations, reliable estimates of the wind velocity turned out to be impossible to obtain. Although remedial measures were taken prior to observation, this task proved to be difficult owing to the inability to replicate the conditions expected during an eclipse in the laboratory. The full extent of the instrumental scattering was apparent only when we analyzed the observational sequence. Nevertheless the experience obtained from this very first attempt to simultaneously and globally measure both the wind velocity and the temperature on the solar corona have provided valuable information to conduct any future observations successfully.

Reginald, Nelson L.↗

MACS, An Instrument and a Methodology for Simultaneous and Global Measurements of the Coronal Electron Temperature and the Solar Wind Velocity on the Solar Corona

In Cram's theory for the formation of the K-coronal spectrum he observed the existence of temperature sensitive anti-nodes, which were separated by temperature insensitive nodes, at certain wave-lengths in the K-coronal spectrum. Cram also showed these properties were remarkably independent of altitude above the solar limb. In this thesis Cram's theory has been extended to incorporate the role of the solar wind in the formation of the K-corona, and we have identified both temperature and wind sensitive intensity ratios. The instrument, MACS, for Multi Aperture Coronal Spectrometer, a fiber optic based spectrograph, was designed for global and simultaneous measurements of the thermal electron temperature and the solar wind velocity in the solar corona. The first ever experiment of this nature was conducted in conjunction with the total solar eclipse of 11 August 1999 in Elazig, Turkey. Here twenty fiber optic tips were positioned in the focal plane of the telescope to observe simultaneously at many different latitudes and two different radial distances in the solar corona. The other ends were vertically stacked and placed at the primary focus of the spectrograph. By isolating the K-coronal spectrum from each fiber the temperature and the wind sensitive intensity ratios were calculated.

Reginald, Nelson L.↗

The Far-Infrared Emission Line and Continuum Spectrum of the Seyfert Galaxy NGC 1068

We report on the analysis of the first complete far-infrared spectrum (43-197 microns) of the Seyfert 2 galaxy NGC 1068 as observed with the Long Wavelength Spectrometer (LWS) onboard the Infrared Space Observatory (ISO). In addition to the 7 expected ionic fine structure emission lines, the OH rotational lines at 79, 119 and 163 microns were all detected in emission, which is unique among galaxies with full LWS spectra, where the 119 micron line, where detected, is always in absorption. The observed line intensities were modelled together with IS0 Short Wavelength Spectrometer (SWS) and optical and ultraviolet line intensities from the literature, considering two independent emission components: the AGN component and the starburst component in the circumnuclear ring of approximately 3kpc in size. Using the UV to mid-IR emission line spectrum to constrain the nuclear ionizing continuum, we have confirmed previous results: a canonical power-law ionizing spectrum is a poorer fit than one with a deep absorption trough, while the presence of a big blue bump is ruled out. Based on the instantaneous starburst age of 5 Myr constrained by the Br gamma equivalent width in the starburst ring, and starburst synthesis models of the mid- and far-infrared fine-structure line emission, a low ionization parameter (U=10(exp -3.5)) and low densities (n=100 cm (exp -3)) are derived. Combining the AGN and starburst components, we succeed in modeling the overall UV to far-IR atomic spectrum of SGC 1068, reproducing the line fluxes to within a factor 2.0 on average with a standard deviation of 1.4. The OH 119 micron emission indicates that the line is collisionally excited, and arises in a warm and dense region. The OH emission has been modeled using spherically symmetric, non-local, non-LTE radiative transfer models. The models indicate that the bulk of the emission arises from the nuclear region, although some extended contribution from the starburst is not ruled out. The OH abundance in the nuclear region is expected to be approximately 10(exp -5), characteristic of X-ray dominated regions.

Spinoglio, Luigi↗

XMM-Newton Observations of GX 339-4

Observations of GX 339-4 were completed in March, 2004, but processed data were only sent to the PI in the late fall of 2004. Thus, serious work on the observations only began in the winter and spring of 2005. Data from each of the instruments - the EPIC CCD cameras, the Reflection Grating Spectrometer, and the Optical Monitor have been reduced and a preliminary analysis is underway. Four days of simultaneous optical radio, and X-ray data was obtained at SAAO, the Australia Telescope, and RXTE, respectively, and preliminary work on the broad-band multi-wavelength lightcurves is also underway. This observational effort is the most extensive ever undertaken to observe a black hole in the "low/hard" state, and will provide new insights into accretion onto black holes at low mass accretion rates.

Mushotzky, Richard F.↗

Characterization of Radiative Heating Anomaly in High Enthalpy Shock Tunnels

Surface heating measurements in shock tunnels operating at high enthalpy have previously showed anomalously high heating, the mechanisms for which have been the subject of much speculation. However, recent tests in JAXA’s High Enthalpy Shock Tunnel (HIEST) have presented compelling evidence that the heating anomaly is due to radiation from the shock layer, produced by impurities within the shock. This paper describes a test series performed with an Apollo capsule model at angle of attack. The purpose of the test is nominally to study transition over the capsule model at high enthalpy, however data is confounded by the presence of this radiative heating. The model is thus instrumented with thermocouple heat flux gauges and spectrometer-coupled fiber optics to characterize the spectrum of radiative heating simultaneous to the heat flux measurements. Analyses of the spectra, estimates of radiative heating corrections, and comparison to computational fluid dynamic simulation of the shock tunnel are presented.

Brett A Cruden↗

Trace Chemical Detection Using Intercalated MXenes as a Signal Enhancing Substrate in Optical Probes

MXenes are 2D materials composed of layered transition metal nitrides or carbides. These materials are synthesized by HF exfoliation from MAX phases (Ti{sub 3}AlC{sub 2}). The 2D nanomaterial was synthesized by the removal of the 'A' element, resulting in a Mxene product (Ti{sub 3}C{sub 2}). MXenes have the general formula M{sub n+1}X{sub n}T{sub x}, where M is an early transition metal, X is Carbon and/or Nitrogen, and T accounts for surface terminated functional groups such as Fluoride, hydroxyl, and oxygen. These materials have very unique properties, similar to graphene, that allows them to be applied in a variety of trace detection techniques including surface-enhanced Raman spectroscopy (SERS). MXenes have also been demonstrated to selectively uptake uranyl ion, UO{sub 2}{sup 2+}. If this property can be combined with SERS or fluorescence detection, it may be possible to use MXenes as the basis for an alternative method to kinetic phosphorescence analysis (KPA) for trace uranyl measurements. Objectives: To confirm that MXene Nano materials are suitable substrates for SERS and sensor development by enhancing Raman signaling. To determine if certain MXene preparation methods yield materials that are more suitable for trace sensing methods. To determine uranyl uptake properties of these MXene materials and test them for analytical signals. Sample Preparation: Preparation of Ti{sub 3}C{sub 2}MXene (at FSU). MXenes were prepared by etching Al from Ti{sub 3}AlC{sub 2} (MAX phase)material. Two etching techniques yield different MXene products: LiF/HCl: Milder reaction, larger MXene flakes. HF: Harsher reaction, smaller flakes, larger layer separation. Products washed to remove etchant, vacuum filtered, and dried. Dried MXene flakes are air-stable. Film preparation for sensor testing (at SRNL): Suspend powder in diH{sub 2}O, purge with Ar, sonicate for 30 min. Centrifuge and collect supernate with suspended particles. Observed LiF-etched Mxene yielded a higher density of particles and darker collected solution. Drop-cast (4 ml) supernate onto slides and dried with Ar. For Rhodamine B (RhB) testing, drop-cast 4 ml drops onto Mxene spots and dried with Ar. Scanning Electron Microscopy conditions: 10 kV Beam energy, high vacuum; Working distance of 8 mm; beam penetration depth appx. 4 microns, beam spot size appx. 2 nanometers. Results: Detection of aluminum correlates with bright spots on image. Presence of aluminum shows that LiF/HCl etching was less thorough than HF etching. Trace Cl detection in LiF images suggests incomplete rinsing. HF has smaller feature size, more layer structure, and increased homogeneity, consistent with expectations. Macroscopic Raman spectroscopy measurements: 532 nm excitation, ∼50 mW with a ∼100 micron spot size (InPhotonics RPB probe). Kaiser Optical Holospec f/1.8 spectrometer with cooled (-60 deg.C) Andor iDus OE420 CCD. LiF 1x supernate showed good signal for trace measurements of Rhodamine B. HF and 1/4x LiF supernates showed little Mxene or Rhodamine B signal. Low deposition densities led to excess background signal from glass slides. For LiF film, response is linear with Rhodamine B concentration over range tested. Will retest with Raman microscope (∼1 micron spot size) to characterize SERS of more dilute LiF and HF etched Mxenes. Conclusions: The LiF etched material was more suitable for macroscopic SERS measurements because it was more concentrated, resulting in a thicker film than the HF etched Mxene and diluted LiF sample. However, the other materials may give greater SERS enhancements, which we hope to determine from measurements with the Raman microscope. From characterization with SEM we concluded that the HF etched Mxene is more uniform/homogenous and has smaller particle size than the LiF etched Mxene. There is still aluminum present in both samples indicating that etching wasn't complete, but the removal of the aluminum was more efficient in the HF method. Path Forward: Observe SERS with Raman microscopy, to obtain better signals for the more diluted samples and be able to compare enhancement effects for the different MXenes. Characterize uranyl sorption into MXene films and test Raman and fluorescence signals. Revisit the etching conditions to improve removal of aluminum. FSU and SRNL will continue to collaborate to create and characterize different Mxene materials and test their usefulness for sensor applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Telescope With A Two-Color Camera And Two Imaging Spectrometers

Proposed remote-sensing optical instrument system includes two charge-coupled-device (CCD) video cameras sensitive to different colors of light; line-imaging infrared spectrometer; and line-imaging ultraviolet spectrometer; all sharing common telescope foreoptics. Principal advantages: compactness and light weight.

Chrisp, Michael P.↗