Search NASA⌕ Search

SEARCH · Search NASA

Results for “optical synchronization systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Synchronization effects on rest frame energy and momentum densities in the proton

We obtain two-dimensional relativistic densities and currents of energy and momentum in a proton at rest. These densities are obtained at surfaces of fixed light front time, which physically corresponds to using an alternative synchronization convention. Mathematically, this is done using tilted light front coordinates, which consist of light front time and ordinary spatial coordinates. In this coordinate system, all 16 components of the energy-momentum tensor (EMT) obtain clear physical interpretations, and the nine Galilean components reproduce results from standard light front coordinates. We find angular modulations in several densities that are absent in the corresponding instant form results, which are explained as optical effects arising from using fixed light front time when motion is present within the target. Additionally, transversely polarized spin-half targets exhibit an energy dipole moment—which evaluates to −1/4 for all targets if the Belinfante EMT is used, but which is target dependent and vanishes for pointlike fermions if the asymmetric EMT is instead used.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Preliminary Chaotic Model of Snapover on High Voltage Solar Cells

High voltage power systems in space will interact with the space plasma in a variety of ways. One of these, Snapover, is characterized by a sudden enlargement of the electron current collection area across normally insulating surfaces. A power drain on solar array power systems will results from this enhanced current collection. Optical observations of the snapover phenomena in the laboratory indicates a functional relation between bia potential and surface glow area. This paper shall explore the potential benefits of modeling the relation between current and bia potential as an aspect of bifurcation analysis in chaos theory. Successful characterizations of snapover as a chaotic phenomena may provide a means of snapover prevention and control through chaotic synchronization.

Mackey, Willie R.↗

Sample-Clock Phase-Control Feedback

To demodulate a communication signal, a receiver must recover and synchronize to the symbol timing of a received waveform. In a system that utilizes digital sampling, the fidelity of synchronization is limited by the time between the symbol boundary and closest sample time location. To reduce this error, one typically uses a sample clock in excess of the symbol rate in order to provide multiple samples per symbol, thereby lowering the error limit to a fraction of a symbol time. For systems with a large modulation bandwidth, the required sample clock rate is prohibitive due to current technological barriers and processing complexity. With precise control of the phase of the sample clock, one can sample the received signal at times arbitrarily close to the symbol boundary, thus obviating the need, from a synchronization perspective, for multiple samples per symbol. Sample-clock phase-control feedback was developed for use in the demodulation of an optical communication signal, where multi-GHz modulation bandwidths would require prohibitively large sample clock frequencies for rates in excess of the symbol rate. A custom mixedsignal (RF/digital) offset phase-locked loop circuit was developed to control the phase of the 6.4-GHz clock that samples the photon-counting detector output. The offset phase-locked loop is driven by a feedback mechanism that continuously corrects for variation in the symbol time due to motion between the transmitter and receiver as well as oscillator instability. This innovation will allow significant improvements in receiver throughput; for example, the throughput of a pulse-position modulation (PPM) with 16 slots can increase from 188 Mb/s to 1.5 Gb/s.

Quirk, Kevin J.↗

VERY-LOW-MASS STELLAR AND SUBSTELLAR COMPANIONS TO SOLAR-LIKE STARS FROM MARVELS. III. A SHORT-PERIOD BROWN DWARF CANDIDATE AROUND AN ACTIVE G0IV SUBGIANT

We present an eccentric, short-period brown dwarf candidate orbiting the active, slightly evolved subgiant star TYC 2087-00255-1, which has effective temperature T{sub eff} = 5903 {+-} 42 K, surface gravity log (g) = 4.07 {+-} 0.16 (cgs), and metallicity [Fe/H] = -0.23 {+-} 0.07. This candidate was discovered using data from the first two years of the Multi-object APO Radial Velocity Exoplanets Large-area Survey, which is part of the third phase of Sloan Digital Sky Survey. From our 38 radial velocity measurements spread over a two-year time baseline, we derive a Keplerian orbital fit with semi-amplitude K = 3.571 {+-} 0.041 km s{sup -1}, period P = 9.0090 {+-} 0.0004 days, and eccentricity e = 0.226 {+-} 0.011. Adopting a mass of 1.16 {+-} 0.11 M{sub Sun} for the subgiant host star, we infer that the companion has a minimum mass of 40.0 {+-} 2.5 M{sub Jup}. Assuming an edge-on orbit, the semimajor axis is 0.090 {+-} 0.003 AU. The host star is photometrically variable at the {approx}1% level with a period of {approx}13.16 {+-} 0.01 days, indicating that the host star spin and companion orbit are not synchronized. Through adaptive optics imaging we also found a point source 643 {+-} 10 mas away from TYC 2087-00255-1, which would have a mass of 0.13 M{sub Sun} if it is physically associated with TYC 2087-00255-1 and has the same age. Future proper motion observation should be able to resolve if this tertiary object is physically associated with TYC 2087-00255-1 and make TYC 2087-00255-1 a triple body system. Core Ca II H and K line emission indicate that the host is chromospherically active, at a level that is consistent with the inferred spin period and measured v{sub rot}sin i, but unusual for a subgiant of this T{sub eff}. This activity could be explained by ongoing tidal spin-up of the host star by the companion.

79 ASTRONOMY AND ASTROPHYSICS↗

Monitoring internal organ motion with continuous wave radar in CT

Purpose: To avoid motion artifacts in medical imaging or to minimize the exposure of healthy tissues in radiation therapy, medical devices are often synchronized with the patient's respiratory motion. Today's respiratory motion monitors require additional effort to prepare the patients, e.g., mounting a motion belt or placing an optical reflector on the patient's breast. Furthermore, they are not able to measure internal organ motion without implanting markers. An interesting alternative to assess the patient's organ motion is continuous wave radar. The aim of this work is to design, implement, and evaluate such a radar system focusing on application in CT.Methods: The authors designed a radar system operating in the 860 MHz band to monitor the patient motion. In the intended application of the radar system, the antennas are located close to the patient's body inside the table of a CT system. One receive and four transmitting antennas are used to avoid the requirement of exact patient positioning. The radar waves propagate into the patient's body and are reflected at tissue boundaries, for example at the borderline between muscle and adipose tissue, or at the boundaries of organs. At present, the authors focus on the detection of respiratory motion. The radar system consists of the hardware mentioned above as well as of dedicated signal processing software to extract the desired information from the radar signal. The system was evaluated using simulations and measurements. To simulate the radar system, a simulation model based on radar and wave field equations was designed and 4D respiratory-gated CT data sets were used as input. The simulated radar signals and the measured data were processed in the same way. The radar system hardware and the signal processing algorithms were tested with data from ten volunteers. As a reference, the respiratory motion signal was recorded using a breast belt simultaneously with the radar measurements.Results: Concerning the measurements of the test persons, there is a very good correlation (ρ= 0.917) between the respiratory motion phases received by the radar system and the external motion monitor. Our concept of using an array of transmitting antennas turned out to be widely insensitive to the positioning of the test persons. A time shift between the respiratory motion curves recorded with the radar system and the motion curves from the external respiratory monitor was observed which indicates a slight difference between internal organ motion and motion detected by the external respiratory monitor. The simulations were in good accordance with the measurements.Conclusions: A continuous wave radar operating in the near field of the antennas can be used to determine the respiratory motion of humans accurately. In contrast to trigger systems used today, the radar system is able to measure motion inside the body. If such a monitor was routinely available in clinical CT, it would be possible optimizing the scan start with respect to the respiratory state of the patient. Breathing commands would potentially widely be avoided, and as far as uncooperative patients or children are concerned, less sedation might be necessary. Further applications of the radar system could be in radiation therapy or interventional imaging for instance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Direct detection optical intersatellite link at 220 Mbps using AlGaAs laser diode and silicon APD with 4-ary PPM signaling

A newly developed 220 Mbps free-space 4-ary pulse position modulation (PPM) direct detection optical communication system is described. High speed GaAs integrated circuits were used to construct the PPM encoder and receiver electronic circuits. Both PPM slot and word timing recovery were provided in the PPM receiver. The optical transmitter consisted of an AlGaAs laser diode (Mitsubishi ML5702A, lambda=821nm) and a high speed driver unit. The photodetector consisted of a silicon avalanche photodiode (APD) (RCA30902S) preceded by an optical interference filter (delta lambda=10nm). Preliminary tests showed that the self-synchronized PPM receiver could achieve a receiver bit error rate of less than 10(exp -6) at 25 nW average received optical signal power or 360 photons per transmitted information bit. The relatively poor receiver sensitivity was believed to be caused by the insufficient electronic bandwidth of the APD preamplifier and the poor linearity of the preamplifier high frequency response.

Sun, Xiaoli↗

Orbiting Stellar Interferometer: An Overview

The Orbiting Stellar Interferometer (OSI) is a concept for a first-generation space interferometer with astrometric and imaging capabilities and is responsive to the recommendations of the Astronomy and Astrophysics Survey Committee for an astrometric interferometry mission. OSI is a triple Michelson interferometer with articulating siderostats and optical delay lines. The design uses a 7m maximum baseline and aperture diameters of 33 cm; the targeted astrometric performance is a wide-field accuracy of 5µas for 20-mag objects. The instrument would also be capable of synthesis imaging with a resolution of 10mas. Laser metrology is used to relax structural requirements thereby reducing cost. The currently envisaged flight system fits into an Atlas II shroud, for insertion into a 900 km sun-synchronous orbit.

['OSI↗

Synchronization of Thomson scattering measurements on MAST using an FPGA based ''Smart'' trigger unit

The MAST Thomson scattering diagnostic has recently been upgraded to make electron density and temperature measurements at 130 points across the 1.5 m diameter of the plasma. The new system is able to take 240 measurements per second using eight Nd:YAG lasers, each running at 30 Hz. The exact firing time of these lasers is adjusted with 100 ns precision using a field programmable gate array based trigger unit. Trigger pulses are produced to fire the lamps of all lasers and the Q switches with the appropriate delay depending on the warm-up status. The lasers may be fired in rapid bursts so as to achieve a high temporal resolution over eight points separated down to the microsecond level. This trigger unit receives optical trigger events and signals from external sources, allowing the trigger sequences to be resynchronized to the start of the plasma pulse and further events during the shot such as the entry of a fuelling pellet or randomly occurring plasma events. This resynchronization of the laser firing sequence allows accurate and reproducible measurements of fast plasma phenomena.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The RS Canum Venaticorum binaries

This review presents a brief up-to-date summary of observational properties of RS CVn binaries, with emphasis on the photometric. A table of the 69 systems known at this time give the orbital period, mean apparent V magnitude, spectral classification, range of amplitude determinations for the photometric wave, and an indication of known period variations and eclipses. Points considered are (1) the underlying cause of the extreme surface activity, (2) the evolutionary status, (3) the geometric configuration, (4) the temperature, size, shape, location, and lifetimes of the dark spot regions, (5) synchronization of rotational and orbital motion, (6) spectroscopic features in the optical and far ultraviolet, (7) the wave migration, (8) the search for spot cycles, and (9) the orbital period variations produced by the enhanced stellar wind.

Hall, D. S.↗

Setting up a Rayleigh Scattering Based Flow Measuring System in a Large Nozzle Testing Facility

A molecular Rayleigh scattering based air density measurement system has been built in a large nozzle testing facility at NASA Glenn Research Center. The technique depends on the light scattering by gas molecules present in air; no artificial seeding is required. Light from a single mode, continuous wave laser was transmitted to the nozzle facility by optical fiber, and light scattered by gas molecules, at various points along the laser beam, is collected and measured by photon-counting electronics. By placing the laser beam and collection optics on synchronized traversing units, the point measurement technique is made effective for surveying density variation over a cross-section of the nozzle plume. Various difficulties associated with dust particles, stray light, high noise level and vibration are discussed. Finally, a limited amount of data from an underexpanded jet are presented and compared with expected variations to validate the technique.

Panda, Jayanta↗

MO-AB-BRA-08: A Modular Multi-Source X-Ray Tube for Novel Computed Tomography Applications

Purpose: To develop and build a practical implementation of an x-ray line source for the rapidly increasing number of multi-source imaging applications in CT. Methods: An innovative x-ray tube was designed using CST Particle Studio, ANSYS, and SolidWorks. A slowly varying magnetic field is synchronized with microsecond gating of multiple thermionic electron sources. Electrostatic simulations were run to optimize the geometry of the optics and prevent electrode arcing. Magnetostatic simulations were used for beam deflection studies and solenoid design. Particle beam trajectories were explored with an emphasis on focusing, acceleration, deflection, and space charge effects. Thermal constraints were analyzed for both transient and steady-state regimes. Electromagnetic simulations informed the design of a prototype unit under construction. Results: Particle tracking simulations for a benchtop system demonstrate that three 80 keV electron beams are able to be finely controlled and laterally swept a combined distance of 15 cm over a stationary target with an oscillating magnetic field in the hundreds of gauss. The beams are pulsed according to scanning sequences developed for implementation in a mock stationary CT scanner capable of a 30 ms temporal resolution. Beam spot diameters are approximately 1 mm for 30 mA beams and the stationary target stays well within thermal limits. The relevant hardware and control circuits were developed for incorporation into a physical prototype. Conclusion: A new multi-source x-ray tube was designed in a modular form factor to push the barriers of high-speed CT and spur growth in emerging imaging applications. This technology can be used as the basis for a stationary high-speed CT scanner, a system for generating a virtual fan-beam for dose reduction, or for reducing scatter radiation in cone-beam CT utilizing a tetrahedron beam CT geometry. A 2.4 kW benchtop system is currently being built to show proof of concept for the tube. Support for this research was provided by the University of Wisconsin Madison, Office of the Vice Chancellor for Research and Graduate Education with funding from the Wisconsin Alumni Research Foundation.

60 APPLIED LIFE SCIENCES↗

Synchronous detection of longitudinal and transverse bunch signals at a storage ring

To understand and control dynamics in the longitudinal phase space, time-resolved measurements of different bunch parameters are required. For a reconstruction of this phase space, the detector systems have to be synchronized. This reconstruction can be used for example for studies of the microbunching instability which occurs if the interaction of the bunch with its own radiation leads to the formation of substructures on the longitudinal bunch profile. These substructures can grow rapidly—leading to a sawtooth-like behavior of the bunch. At KARA, we use a fast-gated intensified camera for energy spread studies, Schottky diodes for coherent synchrotron radiation studies as well as electro-optical spectral decoding for longitudinal bunch profile measurements. For a synchronization, a synchronization scheme is used which compensates for hardware delays. Here in this paper, the different experimental setups and their synchronization are discussed and first results of synchronous measurements presented.

43 PARTICLE ACCELERATORS↗

Polycyclic aromatic hydrocarbons in the atmospheres of Titan and Jupiter

PAHs are important components of the interstellar medium and carbonaceous chondrites, but have never been identified in the reducing atmospheres of the outer solar system. Incompletely characterized complex organic solids (tholins) produced by irradiating simulated Titan atmospheres reproduce well the observed UV/visible/IR optical constants of the Titan stratospheric haze. Titan tholin and a tholin generated in a crude simulation of the atmosphere of Jupiter are examined by two-step laser desorption/multiphoton ionization mass spectrometry. A range of two- to four-ring PAHs, some with one to four alkylation sites, are identified, with a net abundance of about 0.0001 g/g (grams per gram) of tholins produced. Synchronous fluorescence techniques confirm this detection. Titan tholins have proportionately more one- and two-ring PAHs than do Jupiter tholins, which in turn have more four-ring and larger PAHs. The four-ringed PAH chrysene, prominent in some discussions of interstellar grains, is found in Jupiter tholins.

Sagan, Carl↗

Lidar Remote Sensing System

A lidar remote sensing system wherein a laser signal is transmitted along an optical path through a telescope having a primary and secondary mirrors and a rotating prism at the telescope output. When the reflected signal from the target is received it is passed back through the system to a detector, where it is heterodyned with a signal from a local oscillator to detect Doppler frequency shifts in the returned signal. Since the prism is rotating, the prism will be at one position when the signal is transmitted and at another when the returned signal is received. This causes the reflected signal to be off the optical path, reducing the power of the returned signal. To correct this problem a de-rotator or prism is mounted for rotation, in synchronism with the rotating prism. about the optical path in a position to intersect the returned beam and refract it back onto the optical path to reduce the power loss in the returned signal.

Michael J Kavaya↗

A homogeneous sample of binary galaxies: Basic observational properties

A survey of optical characteristics for 585 binary systems, satisfying a condition of apparent isolation on the sky, is presented. Influences of various selection effects distorting the average parameters of the sample are noted. The pair components display mutual similarity over all the global properties: luminosity, diameter, morphological type, mass-to-luminosity ratio, angular momentum etc., which is not due only to selection effects. The observed correlations must be caused by common origin of pair members. Some features (nuclear activity, color index) could acquire similarity during synchronous evolution of double galaxies. Despite the observed isolation, the sample of double systems is seriously contaminated by accidental pairs, and also by members of groups and clusters. After removing false pairs estimates of orbital mass-to-luminosity ratio range from 0 to 30 f(solar), with the mean value (7.8 plus or minus 0.7) f(solar). Binary galaxies possess nearly circular orbits with a typical eccentrity e = 0.25, probably resulting from evolutionary selection driven by component mergers under dynamical friction. The double-galaxy population with space abundance 0.12 plus or minus 0.02 and characteristic merger timescale 0.2 H(exp -1) may significantly influence the rate of dynamical evolution of galaxies.

Karachentsev, I. D.↗

A Novel Photonic Clock and Carrier Recovery Device

As data communication rates climb toward ten Gb/s, clock recovery and synchronization become more difficult, if not impossible, using conventional electronic circuits. We present in this article experimental results of a high speed clock and carrier recovery using a novel device called a photonic oscillator that we recently developed in our laboratory. This device is capable of recovering clock signals up to 70 GHz. To recover the clock, the incoming data is injected into the photonic oscillator either through the optical injection port or the electrical injection port. The free running photonic oscillator is tuned to oscillate at a nominal frequency equal to the clock frequency of the incoming data. With the injection of the data, the photonic oscillator will be quickly locked to clock frequency of the data stream while rejecting other frequency components associated with the data. Consequently, the output of the locked photonic oscillator is a continuous periodical wave synchronized with the incoming data or simply the recovered clock. We have demonstrated a clock to spur ratio of more than 60 dB of the recovered clock using this technique. Similar to the clock recovery, the photonic oscillator can be used to recover a high frequency carrier degraded by noise and an improvement of about 50 dB in signal-to-noise ratio was demonstrated. The photonic oscillator has both electrical and optical inputs and outputs and can be directly interfaced with a photonic system without signal conversion. In addition to clock and carrier recovery, the photonic oscillator can also be used for (1) stable high frequency clock signal generation, (2) frequency multiplication, (3) square wave and comb frequency generation, and (4) photonic phase locked loop.

Yao, X. Steve↗

A New On-Line Diagnosis Protocol for the SPIDER Family of Byzantine Fault Tolerant Architectures

This paper presents the formal verification of a new protocol for online distributed diagnosis for the SPIDER family of architectures. An instance of the Scalable Processor-Independent Design for Electromagnetic Resilience (SPIDER) architecture consists of a collection of processing elements communicating over a Reliable Optical Bus (ROBUS). The ROBUS is a specialized fault-tolerant device that guarantees Interactive Consistency, Distributed Diagnosis (Group Membership), and Synchronization in the presence of a bounded number of physical faults. Formal verification of the original SPIDER diagnosis protocol provided a detailed understanding that led to the discovery of a significantly more efficient protocol. The original protocol was adapted from the formally verified protocol used in the MAFT architecture. It required O(N) message exchanges per defendant to correctly diagnose failures in a system with N nodes. The new protocol achieves the same diagnostic fidelity, but only requires O(1) exchanges per defendant. This paper presents this new diagnosis protocol and a formal proof of its correctness using PVS.

Geser, Alfons↗

Coherent Combining for High‐Power Kerr Combs

Abstract Kerr frequency combs enable the miniaturization of comb sources for applications such as data communications and spectroscopy. However, due to the high field confinement and effective nonlinearity, Kerr combs typically operate with low output comb powers. While nonsolitonic Kerr combs operating in the normal group velocity dispersion (GVD) regime can access high pump‐to‐comb conversion efficiencies and relatively flat spectral profiles, many frequency comb applications require even higher comb‐line powers that are otherwise fundamentally unattainable without the use of optical amplifiers. A high efficient coherent beam combining of Kerr combs is demonstrated via on‐chip synchronization to greatly enhanced comb‐line powers. Two normal GVD Kerr combs are coherently combined for a 2.9 dB increase in comb power compared to a single comb while maintaining a high total pump‐to‐comb conversion efficiency of 26%. Lastly, it is shown that via spectral engineering of two normal GVD combs, it should be possible to significantly increase the spectral flatness of a combined comb. This platform enables fully integrated systems with powers that can readily exceed that of an individual comb system by more than an order of magnitude.

Kim, Bok Young↗