Search NASA⌕ Search

SEARCH · Search NASA

Results for “parametric analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Wind study for high altitude platform design

An analysis of upper air winds was performed to define the wind environment at potential operating altitudes for high-altitude powered platform concepts. Expected wind conditions of the contiguous United States, Pacific area (Alaska to Sea of Japan), and European area (Norwegian and Mediterranean Seas) were obtained using a representative network of sites selected based upon adequate high-altitude sampling, geographic dispersion, and observed upper wind patterns. A data base of twenty plus years of rawinsonde gathered wind information was used in the analysis. Annual variations from surface to 10 mb (approximately 31 km) pressure altitude were investigated to encompass the practical operating range for the platform concepts. Parametric analysis for the United States and foreign areas was performed to provide a basis for vehicle system design tradeoffs. This analysis of wind magnitudes indicates the feasibility of annual operation at a majority of sites and more selective seasonal operation for the extreme conditions between the pressure altitudes of 100 to 25 mb based upon the assumed design speeds.

Strganac, T. W.↗

Advanced extravehicular protective systems study, volume 2

The results of the subsystem studies are presented. Initial identification and evaluation of candidate subsystem concepts in the area of thermal control, humidity control, CO2 control/O2 supply, contaminant control and power supply are discussed. The candidate concepts that were judged to be obviously noncompetitive were deleted from further consideration and the remaining candidate concepts were carried into the go/no go evaluation. A detailed parametric analysis of each of the thermal/humidity control and CO2 control/O2 supply subsystem concepts which passed the go/no go evaluation is described. Based upon the results of the parametric analyses, primary and secondary evaluations of the remaining candidate concepts were conducted. These results and the subsystem recommendations emanating from these results are discussed. In addition, the parametric analyses of the recommended subsystem concepts were updated to reflect the final AEPS specification requirements. A detailed discussion regarding the selection of the AEPS operating pressure level is presented.

Sutton, J. G.↗

Feasibility of modern airships - Preliminary assessment

Attention is given to the NASA program, Feasibility Study of Modern Airships, initiated to investigate potential research and technology programs associated with airship development. A historical survey of the program is presented, including the development of past airship concepts, aerodynamical and design improvements, structure and material concepts, and research in controls, avionics, instrumentation, flight operations, and ground handling. A mission analysis was carried out which considered passenger and cargo transportation, heavy-lift, short-haul applications, surveillance missions, and the transportation of natural gas. A vehicle parametric analysis examined the entire range of airship concepts, discussing both conventional airships and hybrids. Various design options were evaluated, such as choice of structural materials, use of boundary-layer control, and choice of lifting gas.

Ardema, M. D.↗

Safe Affordable Fission Engine (SAFE 30) Module Conductivity Test Thermal Model Correlation

Two SAFE 30 modules were tested to determinate the thermal conductivity efficiency of the tri-cusps filled between the heat pipe and the heater cores. The modules consisted of four one-inch diameter tubes with heaters joined to an empty 1 inch diam. tube. The test was conducted on a vacuum chamber with 4 configurations: tri-cusps filled with and without radiation shielding and non-filled tri-cusps with and without radiation shielding. The tri-cusps material helps the bonding of the heat pipe to the four electric heater cores, filling the gap between the pipes. The baseline configuration is a brazed joint between the pipe. The test consisted of controlling the power applied to the heaters until a set surface temperature is reach. The temperatures varied between a max. of 800 C to 500 C. Test data, input energy and chamber surface temperature from each individual test, was used as boundary conditions for the model. Nodes located on the same location as the test thermocouples were plotted again test data to determinate the accuracy of the analysis. The unknown n variables on the analysis are the radiation emissivity of the pipe and chamber and the radiation view factor between the module and the chamber. A correlation was determined using a parametric analysis varying the surface emissivity and view factor until a good match was reach.

Roman, Jose↗

ENERGY STAR for Tenants: An Online Energy Estimation Tool for Commercial Office Building Tenants

The commercial building sector consumes over 18% of the total energy in the United States. According to the 2012 Commercial Building Energy Consumption Survey (CBECS), office buildings comprise nearly 16 billion square feet of floor space and consume 253 billion kWh of energy annually. Office buildings represent nearly one-fifth of the energy consumed by commercial buildings, more than any other building type. Therefore, monitoring and reducing energy consumption in office buildings has become an increasingly important focus across the United States. The goal of the ENERGY STAR for Tenants program is to recognize office building tenants who demonstrate commitment to energy efficiency and environmental stewardship. Tenants seeking recognition must complete five major steps: estimate energy use, meter energy use, use efficient lighting, use efficient equipment, and share data. NREL is responsible for the underlying analysis performed for step one, estimating energy use. An online survey was developed for tenants to input information about their office space and its internal loads. NREL performed a parametric analysis across a large parameter space of office buildings. The analysis results were processed to map the user inputs to output energy ranges. The mappings enable the web tool to provide users with instant energy usage estimates based on a limited number of inputs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Entry, Descent, and Landing technological barriers and crewed MARSvehicle performance analysis

Mars has been explored historically only by robotic crafts, but a crewed mission encompasses several new engineering challenges – high ballistic coefficient entry, hypersonic decelerators, guided entry for reaching intended destinations within acceptable margins for error in the landing ellipse, and payload mass are all critical factors for evaluation. A comprehensive EDL parametric analysis has been conducted in support of a high mass landing architecture by evaluating three types of vehicles −70° Sphere Cone, Ellipsled and SpaceX hybrid architecture called Red Dragon as potential candidate options for crewed entry vehicles. Aerocapture at the Martian orbit of about 400 km and subsequent Entry-from-orbit scenarios were investigated at velocities of 6.75 km/s and 4 km/s respectively. A study on aerocapture corridor over a range of entry velocities (6–9 km/s) suggests that a hypersonic L/D of 0.3 is sufficient for a Martian aerocapture. Parametric studies conducted by varying aeroshell diameters from 10 m to 15 m for several entry masses up to 150 mt are summarized and results reveal that vehicles with entry masses in the range of about 40–80 mt are capable of delivering cargo with a mass on the order of 5–20 mt. For vehicles with an entry mass of 20 mt to 80 mt, probabilistic Monte Carlo analysis of 5000 cases for each vehicle were run to determine the final landing ellipse and to quantify the statistical uncertainties associated with the trajectory and attitude conditions during atmospheric entry. Strategies and current technological challenges for a human rated Entry, Descent, and Landing to the Martian surface are presented in this study.

Prabhakar Subrahmanyam↗

U.S. Light-Duty Vehicle Air Conditioning Fuel Use and Impact of Solar/Thermal Control Technologies

To reduce fuel consumption and carbon dioxide (CO2) emissions from mobile air conditioning (A/C) systems, 'U.S. Light-Duty Vehicle Greenhouse Gas Emissions and Corporate Average Fuel Economy Standards' identified solar/thermal technologies such as solar control glazings, solar reflective paint, and active and passive cabin ventilation in an off-cycle credit menu. National Renewable Energy Laboratory (NREL) researchers developed a sophisticated analysis process to calculate U.S. light-duty A/C fuel use that was used to assess the impact of these technologies, leveraging thermal and vehicle simulation analysis tools developed under previous U.S. Department of Energy projects. Representative U.S. light-duty driving behaviors and weighting factors including time-of-day of travel, trip duration, and time between trips were characterized and integrated into the analysis. In addition, U.S. weather conditions weighted based on light-duty vehicle registrations were generated and used for the analysis. Three representative vehicle types for the light-duty fleet were selected based on registration data containing vehicle size information. These key inputs were used to support a weighted parametric analysis that quantified vehicle thermal load, vehicle accessory load, and vehicle fuel use. This analysis estimates that 7.6 billion gallons of fuel a year are used in the United States for vehicle A/C, equivalent to 6.1% of the total national light-duty vehicle fuel use. This equates to 30.0 gallons/year per vehicle or 23.5 grams CO 2 per mile (g/mi) for an average U.S. light-duty vehicle. A/C is a significant contributor to national fuel use; therefore, technologies that reduce A/C loads have an opportunity to reduce fuel consumption, reduce imported oil, and improve energy security. Implementing solar control glass reduced the CO 2 emissions by 2.0 g/mi and the reduction due to solar reflective paint was 0.8 g/mi. The active and passive ventilation strategies as defined in this analysis only reduced emissions by 0.1 and 0.2 g/mi, respectively. This analysis shows the potential to reduce operational costs, A/C fuel use, and CO 2 emissions by implementing advanced vehicle climate control technologies including the solar/thermal technologies.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Orbiter altitude at ALT interface based on ALSES (Approach and Landing Shuttle Engineering Simulation) analyses. Mission planning, mission analysis and software formulation

The details of the orbiter altitude attainable at the approach and landing tests (ALT) interface determined by the approach and landing shuttle engineering simulation (manned) were documented. The analysis culminated in the verification of the trends observed in a similar analysis performed previously on the space vehicle dynamics simulation (unmanned). Altitude variations attributable to pilot steering variability ranged between 492 ft higher to 383 ft lower. The requirement for this parametric analysis is first elaborated. The specifications, assumptions, and analytical approach used to determine the orbiter altitude at the ALT interface are then presented, followed by the results of the analytical approach and the conclusions and recommendations.

Colwell, C. L.↗

VESsel GENeration Analysis (VESGEN): Innovative Vascular Mappings for Astronaut Exploration Health Risks and Human Terrestrial Medicine

Currently, astronauts face significant health risks in future long-duration exploration missions such as colonizing the Moon and traveling to Mars. Numerous risks include greatly increased radiation exposures beyond the low earth orbit (LEO) of the ISS, and visual and ocular impairments in response to microgravity environments. The cardiovascular system is a key mediator in human physiological responses to radiation and microgravity. Moreover, blood vessels are necessarily involved in the progression and treatment of vascular-dependent terrestrial diseases such as cancer, coronary vessel disease, wound-healing, reproductive disorders, and diabetes. NASA developed an innovative, globally requested beta-level software, VESsel GENeration Analysis (VESGEN) to map and quantify vascular remodeling for application to astronaut and terrestrial health challenges. VESGEN mappings of branching vascular trees and networks are based on a weighted multi-parametric analysis derived from vascular physiological branching rules. Complex vascular branching patterns are determined by biological signaling mechanisms together with the fluid mechanics of multi-phase laminar blood flow.

astronaut↗

simuwatt - A Tablet Based Electronic Auditing Tool

'simuwatt Energy Auditor' (TM) is a new tablet-based electronic auditing tool that is designed to dramatically reduce the time and cost to perform investment-grade audits and improve quality and consistency. The tool uses the U.S. Department of Energy's OpenStudio modeling platform and integrated Building Component Library to automate modeling and analysis. simuwatt's software-guided workflow helps users gather required data, and provides the data in a standard electronic format that is automatically converted to a baseline OpenStudio model for energy analysis. The baseline energy model is calibrated against actual monthly energy use to ASHRAE Standard 14 guidelines. Energy conservation measures from the Building Component Library are then evaluated using OpenStudio's parametric analysis capability. Automated reporting creates audit documents that describe recommended packages of energy conservation measures. The development of this tool was partially funded by the U.S. Department of Defense's Environmental Security Technology Certification Program. As part of this program, the tool is being tested at 13 buildings on 5 Department of Defense sites across the United States. Results of the first simuwatt audit tool demonstration are presented in this paper.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Impact of public electric vehicle charging infrastructure

Our work uses market analysis and simulation to explore the potential of public charging infrastructure to spur US battery electric vehicle (BEV) sales, increase national electrified mileage, and lower greenhouse gas (GHG) emissions. By employing both scenario and parametric analysis for policy driven injection of public charging stations we find the following: (1) For large deployments of public chargers, DC fast chargers are more effective than level 2 chargers at increasing BEV sales, increasing electrified mileage, and lowering GHG emissions, even if only one DC fast charging station can be built for every ten level 2 charging stations. (2) A national initiative to build DC fast charging infrastructure will see diminishing returns on investment at approximately 30,000 stations. (3) Some infrastructure deployment costs can be defrayed by passing them back to electric vehicle consumers, but once those costs to the consumer reach the equivalent of approximately 12¢/kWh for all miles driven, almost all gains to BEV sales and GHG emissions reductions from infrastructure construction are lost.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Reductions in wind farm main bearing rating lives resulting from wake impingement

This paper studies the impacts of wake impingement on main bearing rating lives predicted during the wind turbine design stage. A computational tool chain was developed to explore and quantify these effects across a wind farm populated by 10 MW wind turbines. Wind field and turbine load modelling was undertaken using the Dynamiks Python package, including application of a dynamic wake meandering model. The ISO 281 basic bearing rating life formulation was subsequently applied in order to evaluate impacts from wake effects. Analyses included a two-turbine parametric analysis, followed by a full wind farm analysis undertaken for the TotalControl 32-turbine reference wind farm, including full wind rose simulations across all operational wind speeds. Site conditions were accounted for using a Weibull wind speed distribution and a range of parametric wind direction rose models. Results indicate that wind farm main bearing rating lives are negatively impacted by the effects of wake impingement, resulting in rating life reductions for the analysed wind farm of the order of 16 % on average and as much as 20 %–25 %, both for the locating main bearing. Despite these high sensitivities, it is important to note that these resultant rating lives (i.e. the predicted lives) still far exceed the standard wind turbine operational lifetimes of 20–30 years. Wake impacts were also found to be asymmetrically related to the side on which the rotor is impinged, suggesting that, for the main bearing, there may be a “better” side for wake impingement to occur. Rating life sensitivities to wind rose shape were also observed. While these findings must be interpreted with due consideration for the various methodological limitations present, they provide compelling evidence that wake effects at the wind farm level should necessarily be included when undertaking main bearing operational load modelling, rating life assessment, or other load-related analyses.

17 WIND ENERGY↗

Matrix cracking in composite laminates with resin-rich interlaminar layers

Fracture mechanics analysis and test data for a toughened composite material that has a resin-rich interlaminar layer (RIL) were used to investigate in situ strength. Exposure to a range of environmental conditions was considered. A parametric analysis study was performed to judge the effects of laminate and material variables. A finite thickness effect, indicating an interaction between ply group thickness and effective flaw size, was found dominant. The magnitude of the effect was directly related to RIL stiffness. In situ strength was found to decrease with decreasing RIL stiffness. This work indicates the need to use a fracture mechanics model of actual lamina microstructure and heterogeneous properties to predict in situ strength in materials with RIL.

Ilcewicz, Larry B.↗

Data for "Quantifying the Propagation of Parametric Uncertainty on Flux Balance Analysis"

In the repository are example scripts that perform uncertainty injection and propagation to flux balance analysis with outputs for a small sample size (for demonstration purpose only). For proper analysis, user should download the scripts and run for a large sample size (e.g., 10,000 samples). If you use the scripts, please cite the following Metabolic Engineering article: “Quantifying the propagation of parametric uncertainty on flux balance analysis” (https://doi.org/10.1016/j.ymben.2021.10.012) There are two subdirectories: /uncFBA/uncBiom: injection of normally distributed noise to biomass precursor coeffcients and ATP maintenance (growth-associated ATP maintenance (GAM) and non-growth associated ATP maintenance (NGAM)) /uncFBA/uncRHS: departure from steady-state by adding noise drawn from normal distribution to the RHS terms of mass balance constraints

Metabolomics↗

Potential energy savings benefits and limitations of radiative cooling coatings for U.S. residential buildings

We report radiative coatings are a promising strategy to implement passive cooling that provides an eco-friendly pathway to achieve energy efficiency in buildings. This study investigates the benefits and limitations of implementing radiative coatings on the building envelope, particularly the roof, of residential buildings in the United States. The analysis compares the performance of an ideal radiative coating with broadband surface properties to a realistic radiative coating with diffuse and semitransparent properties. To enhance the net energy efficiency of buildings, we carried out a comprehensive parametric analysis comprising key radiation surface properties to maximize cooling energy savings while minimizing heating energy penalties. A countrywide assessment for 68 locations across the United States showed that net energy savings are a strong function of the climatic and atmospheric conditions. Broadly, southern locations showed high overall energy savings whereas northern locations exhibited high overall energy penalties. Locations in International Energy Conservation Code (IECC) climate zones 1A, 2A, and 2B showed a net annual energy savings above 5%, whereas locations in IECC climate zones 5B, 6B, and 7 showed a net annual energy penalty greater than 3%. The hot and dry climate of Phoenix, Arizona, showed the highest overall energy savings of 426 kWh (6.2%). Additionally, the mathematical correlation reveals that the net energy savings of a location is positive only when its average cooling degree days is greater than 5.5 or its average heating degree days is less than 10.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Orbital Injection of the SEDSAT Satellite: Tethered Systems Dynamics and Flight Data Analysis

This report deals with the following topics which are all related to the orbital injection of the SEDSAT satellite: Dynamics and Stability of Tether Oscillations after the First Cut. The dynamics of the tether after the first cut (i.e., without the Shuttle attached to it) is investigated. The tether oscillations with the free end are analyzed in order to assess the stability of the rectilinear configuration in between the two tether cuts; analysis of Unstable Modes. The unstable modes that appear for high libration angles are further investigated in order to determine their occurrences and the possible transition from bound librations to rotations; Orbital Release Strategies for SEDSAT. A parametric analysis of the orbital decay rate of the SEDSAT satellite after the two tether cuts has been carried out as a function of the following free parameters: libration amplitude at the end of deployment, deviation angle from LV at the first cut, and orbital anomaly at the second cut. The values of these parameters that provide a minimum orbital decay rate of the satellite (after the two cuts) have been computed; and Dynamics and Control of SEDSAT. The deployment control law has been modified to cope with the new ejection velocity of the satellite from the Shuttle cargo bay. New reference profiles have been derived as well as new control parameters. Timing errors at the satellite release as a function of the variations of the initial conditions and the tension model parameters have been estimated for the modified control law.

Lorenzini, Enrico C.↗

A Framework for Daylighting Optimization in Whole Buildings with OpenStudio

We present a toolkit and workflow for leveraging the OpenStudio (Guglielmetti et al. 2010) platform to perform daylighting analysis and optimization in a whole building energy modeling (BEM) context. We have re-implemented OpenStudio's integrated Radiance and EnergyPlus functionality as an OpenStudio Measure. The OpenStudio Radiance Measure works within the OpenStudio Application and Parametric Analysis Tool, as well as the OpenStudio Server large scale analysis framework, allowing a rigorous daylighting simulation to be performed on a single building model or potentially an entire population of programmatically generated models. The Radiance simulation results can automatically inform the broader building energy model, and provide dynamic daylight metrics as a basis for decision. Through introduction and example, this paper illustrates the utility of the OpenStudio building energy modeling platform to leverage existing simulation tools for integrated building energy performance simulation, daylighting analysis, and reportage.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Thermodynamic analysis and optimization of supercritical carbon dioxide Brayton cycles for use with low-grade geothermal heat sources

The transcritical carbon dioxide Rankine cycle has emerged as an alternative for power generation in low-grade heat applications. However, the low heat rejection temperatures required for condensing the carbon dioxide is almost prohibitive for many locations. A simple solution is the adoption of a supercritical carbon dioxide Brayton cycle which does not need such low temperature heat sinks. This power cycle has been poorly studied previously in low-grade heat applications. Therefore, with the aim of determining the performance and feasibility of the supercritical carbon dioxide Brayton cycle from thermodynamic viewpoint, using a low-grade geothermal heat source, this paper presents a comparative thermodynamic analysis between four different supercritical carbon dioxide Brayton cycles. For this purpose, detailed models were developed and solved by coupling the thermodynamic model with the thermal-hydraulic model of a Printed Circuit Heat Exchanger. Subsequently, simulations of a base case, a parametric analysis, and an optimization using Genetic Algorithms, were carried out. Results show that there is a combination of operating conditions that maximizes the electrical output of the system. Besides, some values of the minimum pressure of the cycles can increase substantially the precooler cooling water pumping power. At the optimum design point, using a 20 kg/s geothermal brine stream at 150 °C as heat source with a minimum allowable reinjection temperature of 70 °C, the Intercooled Recuperated Brayton Cycle achieved the highest electric power output, energy and exergy efficiencies, obtaining values of 779.99 kW, 11.51%, and 52.49%, respectively. The other feasible alternatives were the Recuperated Brayton Cycle, the Simple Brayton Cycle and the Intercooled Brayton Cycle, ranked, in that order.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗