Search NASA⌕ Search

SEARCH · Search NASA

Results for “permeability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Oxidation resistant porous material for transpiration cooled vanes

Porous metal sheet with controlled permeability was made by space winding and diffusion bonding fine wire. Two iron-chromium-aluminum alloys and three-chromium alloys were used: GE 1541 (Fe-Cr-Al-Y), H 875 (Fe-Cr-Al-Si), TD Ni Cr, DH 245 (Ni-Cr-Al-Si) and DH 242 (Ni-Cr-Si-Cb). GE 1541 and H 875 were shown in initial tests to have greater oxidation resistance than the other candidate alloys and were therefore tested more extensively. These two materials were cyclic furnace oxidation tested in air at 1800 and 2000 F for accumulated exposure times of 4, 16, 64, 100, 200, 300, 400, 500, and and 600 hours. Oxidation weight gain, permeability change and mechanical properties were determined after exposure. Metallographic examination was performed to determine effects of exposure on the porous metal and electron beam weld joints of porous sheet to IN 100 strut material. Hundred hour stress rupture life and tensile tests were performed at 1800 F. Both alloys had excellent oxidation resistance and retention of mechanical properties and appear suitable for use as transpiration cooling materials in high temperature gas turbine engines.

Madsen, P.↗

Lunar soil properties and soil mechanics. Flow in porous media under rarefied gas conditions. Research phase: Fluid conductivity of lunar surface materials

Theoretical and experimental research on fluid conductivity of lunar surface materials is summarized. Theoretical methods were developed for the analysis of transitional and free-molecular flows, and for analysis of lunar permeability probe data in general. Experimental studies of rarefied flows under conditions of a large pressure gradient show flows in the continuum regime to be responsible for the largest portion of the pressure drop between source and sink for one dimensional flow, provided the entrance Knudsen number is sufficiently small. The concept of local similarity leading to a universal nondimensional function of Knudsen number was shown to have approximate validity; flows in all regimes may be described in terms of an area fraction and a single length parameter. Synthetic porous media prepared from glass beads exhibited flow behavior similar in many regards to that of a natural sandstone; studies using artificial stones with known pore configurations may lead to new insight concerning the structure of natural materials. The experimental method involving the use of segmented specimens of large permeability is shown to be fruitful.

Hurlbut, F. C.↗

Static structural tests of a 1.5-meter diameter fabric attached inflatable decelerator

Meridional tape forces, permeability, and change in model contours were measured on the aft half of a 1.5-m-diameter attached inflatable decelerator (AID). Inflation pressures up to 103 kN per square meter and external pressures of 0.14 to 102 kN per square meter were used. The results indicated that the model stresses were near the desired isotensoid condition. Future AID designs should consider both stiffness and strength of the meridional tapes to obtain the optimum division of load between tapes and fabric. Permeability of pressurized fabric structures is a few orders of magnitude higher than that obtained in the standard low-pressure test on material specimens.

Willis, C. M.↗

A proposed magnetic digital temperature transducer, volume 1

A study has been made of the feasibility of using the discontinuous permeability versus temperature characteristics of some magnetic materials for a digital temperature transducer and a thermally controlled ON-OFF switch. Simple logic converts the number of output pulse to a digital word recognizable by the system. Efforts have been concentrated on materials with Curie temperatures between 0 and 100 C. One compound has the composition Mn(5-x)Fe(x)Ge3 where the amount of iron determines the transition temperature. The other compound is Ni-Zn ferrite and has the compositon Ni(1-x)Zn(x)Fe(1.95)O4 where the nickel: zinc ratio determines the transition temperature. A detailed report of materials prepared is presented. Toroidal inductors of the material have been constructed and the change in inductance with temperature measured. In view of these initial measurements, it is felt that a transducer utilizing the permeability versus temperature characteristics of these materials has promise as a reliable and sensitive solid state digital temperature transducer.

Collier, T. E.↗

The theoretical output of a ring core fluxgate sensor.

Demonstration that the output from a ring core sensor is directly proportional to the first time derivative of the product of dynamic permeability and magnetic intensity perturbation within the core caused by an external, uniform magnetic field. (Dynamic permeability is defined to be the slope of the hysteresis loop at a given point in time). Assuming that ellipsoidal shells can approximate the core, the demagnetization factor can be 'estimated' in the first order to be proportional to the first power of the quantity tape thickness (or number of wraps) divided by the core diameter. The constant of proportionality is determined from laboratory data. When an additional scale adjustment is applied to the resulting sensor output formula, the computed output tracks laboratory data for a range of sensor geometries.

Burger, J. R.↗

Investigation of Kevlar fabric based materials for use with inflatable structures

Design, manufacture and testing of laminated and coated composite materials incorporating a structural matrix of Kevlar are reported in detail. The practicality of using Kevlar in aerostat materials is demonstrated and data are provided on practical weaves, lamination and coating particulars, rigidity, strength, weight, elastic coefficients, abrasion resistance, crease effects, peel strength, blocking tendencies, helium permeability, and fabrication techniques. Properties of the Kevlar based materials are compared with conventional, Dacron reinforced counterparts. A comprehensive test and qualification program is discussed and quantitative biaxial tensile and shear test data are provided. The investigation shows that single ply laminates of Kevlar and plastic films offer significant strength to weight improvements, are less permeable than two ply coated materials, but have a lower flex life.

Niccum, R. J.↗

Magnetism and the interior of the moon

During the time period 1961-1972 eleven magnetometers were sent to the moon. The results of lunar magnetometer data analysis are reviewed, with emphasis on the lunar interior. Magnetic fields have been measured on the lunar surface at the Apollo 12, 14, 15, and 16 landing sites. The remanent field values at these sites are given. Satellite and surface measurements show strong evidence that the lunar crust is magnetized over much of the lunar globe. The origin of the lunar remanent field is not yet satisfactorily understood; several source models are presented. Simultaneous data from the Apollo 12 lunar surface magnetometer and the Explorer 35 Ames magnetometer are used to construct a wholemoon hysteresis curve, from which the global lunar permeability is determined. Total iron abundance is calculated for two assumed compositional models of the lunar interior. Other lunar models with a small iron core and with a shallow iron-rich layer are also discussed in light of the measured global permeability.

Dyal, P.↗

Capillary flow through heat-pipe wicks

Theoretical expressions are obtained for the capillary-pressure limit and permeability of a fibrous wick in terms of the porosity and fiber diameter. Hysteresis in capillary pressure is included through the introduction of an empirical hysteresis constant. A partial-saturation model based on the statistical distribution of local porosity requires an additional empirical constant, the standard deviation. The theory is compared to results of a beta-ray absorption experiment that measured the liquid content of a partially saturated wick and to results of permeability measurements on partially and fully saturated wicks. A simple wick-weighing experiment is described that yields values for the empirical hysteresis constant and the standard deviation. Theoretical results are used to design an optimum wick.

Eninger, J. E.↗

Physiological and biochemical characteristics of adrenergic receptors and pathways in brown adipocytes

Mechanisms involved in the thermogenic response of brown adipose tissue (BAT) to sympathetic nervous stimulation (e.g., by cold exposure) and to norepinephrine (NE) release are investigated. Three effects appear to play a role in the increased oxygen consumption (and heat production) of the adipocytes: increased membrane permeability, activation of the beta-adrenergic pathway, and enhancement of Na(+)/K(+) membrane pump activity. Increased passive influx of Na(+) and efflux of K(+) due to greater permeability raise the energy demands of the Na/K pump; the pump is also stimulated by increased cyclic AMP synthesis resulting from activation by NE of membrane-bound adenyl cyclase. Studies with inhibitors such as propanolol, phentolamine, and ouabain support this hypothesis.

Horwitz, B. A.↗

The permanent and induced magnetic dipole moment of the moon

Magnetic field observations with the Apollo 15 subsatellite have been used to deduce the components of both the permanent and induced lunar dipole moments in the orbital plane. The present permanent lunar magnetic dipole moment in the orbital plane is less than 1.3 times ten to the eighteenth power gauss-cu cm. Any uniformly magnetized near surface layer is therefore constrained to have a thickness-magnetization product less than 2.5 emu-cm per g. The induced moment opposes the external field, implying the existence of a substantial lunar ionosphere with a permeability between 0.63 and 0.85. Combining this with recent measures of the ratio of the relative field strength at the ALSEP and Explorer 35 magnetometers indicates that the global lunar permeability relative to the plasma in the geomagnetic tail lobes is between 1.008 and 1.03.

Russell, C. T.↗

Properties of the moon and its environment from lunar magnetometer measurements

Lunar analysis of data from a total of nine lunar magnetometers is described. Results obtained concerning electromagnetic, compositional, and structural properties of the lunar interior are discussed. Specific topics covered include: lunar magnetic permeability and iron abundance; limits on a highly conducting lunar core; lunar electrical conductivity; and internal structure inferred from conductivity and permeability results.

Parkin, C. W.↗

Structure of the lunar interior from magnetic field measurements

A network of lunar surface and orbiting magnetometers was used to obtain measurements of electrical conductivity and magnetic permeability of the lunar interior. An exceptionally large solar transient event, when the moon was in a geomagnetic tail lobe, enabled the most accurate lunar electromagnetic sounding information to date to be obtained. A new analytical technique using a network of two surface magnetometers and a satellite magnetometer superimposes many time series measurements to improve the signal-to-noise ratio and uses both the amplitude and phase information of all three vector components of the magnetic field data. Size constraints on a hypothetical highly conducting lunar core are investigated with the aid of the permeability results.

Dyal, P.↗

Magnetometer data errors and lunar induction studies

Errors in lunar magnetic field data acquired by the Apollo 12, 15 and 16 surface magnetometers and the two magnetometers on board the lunar-orbiting Explorer 35 satellite are examined and the implications of these errors for investigations of lunar magnetic induction are discussed. It is found that during the first four lunations of Apollo 12 magnetometer operation, the gain and offset differences with respect to the Explorer magnetomers are 1 to 2% and 0.5 gamma, respectively, with close agreement between the two Explorer magnetometers, but increase up to 60% and 1 gamma by the eighth lunation, accompanied by the degradation of the agreement between the orbital instruments, which indicates the malfunction of the Explorer instruments by the fifth lunation. An additional anomaly, associated with the exit of the spacecraft from the lunar shadow is also found, along with the nonlinear field response of the Apollo 15 magnetometer near zero field and small magnitude noise in the surface magnetometers. The effects of gain errors on electrical conductivity determinations are estimated and previously published lunar magnetic permeability results are adjusted to account for magnetometer gain uncertainties, yielding a permeability of 1.012 + or - 0.011.

Daily, W. D.↗

Geological assessment probe

A probe is described which can be installed in a side hole that extends from a bore hole in the Earth, to assess the permeability of the strata surrounding the borehole. The probe is elongated and has a plurality of seals spaced therealong and sealed to the walls of the side hole to form a plurality of chambers sealed from one another. A tracer fluid injector on the probe can inject a tracer fluid into one of the chambers, while a tracer fluid detector located in another chamber can detect the tracer fluid, to thereby sense the permeability of the strata surrounding the side hole. The probe can include a train of modules, with each module having an inflatable packer which is inflated by the difference between the borehole pressure and the strata pressure.

Collins, E. R.↗

Displacement of plasma protein and conduction velocity in rats under action of acceleration forces and hypokinesia

The permeability of capillary vessels was investigated in order to determine if acceleration alone or following prolonged hypokinesia would induce changes in the vascular wall leading to the penetration by l-albumins and/or proteins with larger molecules. In rats undergoing action of +5 Gz accelerations, no increase in vascular permeability, as tested with the use of (Cr-5k)-globulin, was demostrated. In rats immobilized for 4 weeks before centrifugation, rather weak migration of (Cr-51)-globulin from the vessels was observed. Immobilization resulted also in lowering of conduction velocity in the sciatic nerve.

Baranski, S.↗

Axial-field permanent magnet motors for electric vehicles

The modelling of an anisotropic alnico magnet for the purpose of field computation involves assigning a value for the material's permeability in the transverse direction. This is generally based upon the preferred direction properties, being all that are easily available. By analyzing the rotation of intrinsic magnetization due to the self demagnetizing field, it is shown that the common assumptions relating the transverse to the preferred direction are not accurate. Transverse magnetization characteristics are needed, and these are given for Alnico 5, 5-7, and 8 magnets, yielding appropriate permeability values.

Campbell, P.↗

Hostile environmental conditions facing candidate alloys for the automotive Stirling engine

The materials research program in support of the Automotive Stirling Engine Project focuses on the hot heater head of the engine including the heater head tubes, cylinders, and regenerator housings, which are considered to be the most critical components from a materials viewpoint. The specific areas of investigation in the program involve hydrogen permeability testing, doping of the hydrogen working fluid to reduce permeability rates, oxidation/corrosion studies, creep-rupture evaluation, and assessing effects of hydrogen environment on mechanical properties. Emphasis is placed on the materials challenges that result from the use of hydrogen as the working fluid. Previously announced in STAR as N81-26236

Stephens, J. R.↗

Lithologic and Structural Control on Slope Morphology in the Valles Marineris

Throughout the Valles Marineris scarp morphology varies as a function of lithology, structure and scarp height. In addition lithology is an important control on permeability and the relative importance of spring sapping processes. Geomorphic mapping of distinct subareas can be used to define the characteristic scarp forms. Distinct morphologic zones defined on the basis of regional variations in lithology are described. Lithology and tectonic history are shown to be the two most important factors controlling slope development. Regional variation in scarp morphology can be correlated with the orientation and density of fracture systems; scarp height and the presence of rejuvenated fault scarps; and the thickness and degree of exposure of presumably less competent, more permeable, water saturated crated plateau material in the chasmata scarps.

Patton, P. C.↗