At least 271 records · Page 15

Control considerations for high frequency, resonant, power processing equipment used in large systems

Addressed is a class of resonant power processing equipment designed to be used in an integrated high frequency (20 KHz domain), utility power system for large, multi-user spacecraft and other aerospace vehicles. It describes a hardware approach, which has been the basis for parametric and physical data used to justify the selection of high frequency ac as the PMAD baseline for the space station. This paper is part of a larger effort undertaken by NASA and General Dynamics to be sure that all potential space station contractors and other aerospace power system designers understand and can comfortably use this technology, which is now widely used in the commercial sector. In this paper, we will examine control requirements, stability, and operational modes; and their hardware impacts from an integrated system point of view. The current space station PMAD system will provide the overall requirements model to develop an understanding of the performance of this type of system with regard to: (1) regulation; (2) power bus stability and voltage control; (3) source impedance; (4) transient response; (5) power factor effects, and (6) limits and overloads.

Mildice, J. W.↗

Control considerations for high frequency, resonant, power processing equipment used in large systems

Addressed is a class of resonant power processing equipment designed to be used in an integrated high frequency (20 KHz domain), utility power system for large, multi-user spacecraft and other aerospace vehicles. It describes a hardware approach, which has been the basis for parametric and physical data used to justify the selection of high frequency ac as the PMAD baseline for the space station. This paper is part of a larger effort undertaken by NASA and General Dynamics to be sure that all potential space station contractors and other aerospace power system designers understand and can comfortably use this technology, which is now widely used in the commercial sector. In this paper, we will examine control requirements, stability, and operational modes; and their hardware impacts from an integrated system point of view. The current space station PMAD system will provide the overall requirements model to develop an understanding of the performance of this type of system with regard to: (1) regulation; (2) power bus stability and voltage control; (3) source impedance; (4) transient response; (5) power factor effects; and (6) limits and overloads.

Mildice, J. W.↗

Development of improved p-type silicon-germanium alloys

Annealing experiments in the temperature range 1100-1275 C have been performed on p-type Si(0.8)Ge(0.2) samples with BP, B(6.5)P, and GaSb material additives. Both electrical resistivity and Seebeck coefficient generally decrease for these samples as annealing temperature is increased, with thermoelectric power factor sometimes being improved by annealing.

Mclane, George↗

Thermoelectric properties of cerium monopnictides

Several cerium pnictides have been synthesized from the pure elements and hot pressed into test samples. Measurements of Seebeck coefficients and electrical resistivities were performed on these samples from room temperature to 1000 C. Cerium arsenide and cerium antimonide are n-type; cerium nitride changes from p-type to n-type conduction at 800 C. The materials are semimetals with resistivities below 1 mohm/cm. Cerium arsenide is the most favorable of the pnictides studied for high-temperature thermoelectric energy conversion, with an average power factor of 15 microW/cm K sq from 500 to 1000 C.

Danielson, L. R.↗

Properties of silicon-germanium thermoelectric alloys with additives

The paper reports the results of measurements (Seebeck and Hall coefficients, electrical resistivity, and thermal conductivity) on silicon-germanium (Si-20 at. pct Ge) alloy with boron phosphide, B(6.5)P) as an additive, prepared as described by McLane et al. (1986). The power factor (Seebeck coefficient squared divided by electrical resistivity) and the thermal conductivity of SeGe/B(6.5)P material were found to be lower than for the 'standard' SiGe (Si-22 at. pct Ge) material. However, no net improvement was achieved in the figure-of-merit of the sample tested. It is suggested that structural inhomogeneities, revealed by a SEM examination, might be responsible for this lack of improvement.

Mclane, George↗

Pulse-Population Modulation For Induction Machines

Low-frequency synthesizer developed to provide low-frequency waveform by synthesis from high-frequency power system. Waveform assembled by allowing conduction of discrete half cycles of high-frequency carrier. Frequency of synthesized wave controlled by pulse pattern. By controlling relationship between slip and stator frequencies, one operates induction motor either as motor or generator. Such bidirectional energy transducer used as starter/generator for engine, or as servo-mechanism for control of acceleration and deceleration. Other advantages include operation under controlled voltage-to-frequency ratios to maintain high-efficiency and high power factor, and no reflection of low-frequency noise into 20-kHz distribution bus.

Hansen, Irving G.↗

The effects of nonlinear loading upon the Space Station Freedom 20 kHz power system

The Space Station Freedom power distribution system, which consists of dual redundant 20-kHz, 440-V RMS, single-phase power systems, is discussed. The effect of a typical space station nonlinear load on the measurement of RMS current and voltage at various points in the space station power system has been investigated using the Electromagnetic Transients Program (EMTP). The load current distortion at the user interface, its effect on the distribution system, and its relationship to power factor have been studied. Modeling results are compared to test data. The differences under nonlinear loading are evaluated and presented as a measure of distribution voltage distortion and current measurement accuracy.

Leskovich, R. Thomas↗

Effect of Ga and P dopants on the thermoelectric properties of n-type SiGe

The purpose of this study was to hot-press improved n-type Si80Ge20/GaP samples directly (without any heat treatment) and to confirm that a Ga/P ratio less than one increases the solubility of P and, hence, improves the power factor and Z. One of the three samples (Ga/P = 0.43) had an improvement in Z of about 20 percent between 400 and 1000 C over that for standard SiGe. This demonstrates that improved samples can be pressed directly and that a Ga/P ratio less than one is necessary. The other two samples (Ga/P = 0.33 and 0.50) had Z's equal to or less than that of standard SiGe but had a lower hot-pressing temperature than the improved sample.

Draper, S. L.↗

Seasonal nitrous oxide flux from an intensively managed pasture in a humid subtropical ecosystem

Nitrous oxide (N2O) flux from vented chambers was measured over intensively and minimally managed bermuda grass hay meadows in a humid, subtropical ecosystem for several years during scheduled sampling protocol following harvest, fertilization and rainfall events while measuring diel N2O emissions once during each of 5 seasonal day growth cycles which divided each calendar year. Soil pools of nitrite NO2(-), nitrate NO3(-), and ammonia (NH3) were measured in soil samples taken at 2 and 10 cm depths during each emission collection to determine transformations of the nitrogen pools coupled with N2O emissions. The highest diel N2O emission occur midday in the Spring cycle, measuring 9.0 g N/ha/d only for several weeks, while emissions dropped to less than 1.0 g N/ha/day during hot, dry, and colder months. Intensively managed meadows (4 fertilizations and harvests per year plus pest management) induced higher seasonal N2O emissions than minimal treatment (1 fertilization and harvest) averaging 2.75 and 5.97 g N/ha/day. Nitrous oxide emission data as responses to soil parameters and environmental parameters were also measured where air temperature, soil moisture, and fertilization were the most powerful factors.

Brams, Eugene A.↗

Experimental approaches for improving SiGe thermoelectric efficiency at JPL

Efforts to improve the thermoelectric efficiency of silicon-germanium alloys are discussed. These efforts are essentially focused on substantially enhancing carrier concentration levels and thus increasing the power factor values of n-type materials. With the help of thermodynamic phase diagram calculations, a combination of various crystal growth and dopant saturation techniques is used for this purpose. Bulk polycrystal growth of double-doped materials is achieved by zone leveling while a new method (the traveling heater method) for high-quality single-crystal growth of SiGe is being developed. Thin films of homogeneous single-crystalline multidoped Si80Ge20 have also been successfully grown from low-temperature melts to investigate combined dopant solid solubility variations. Very high carrier concentration levels were obtained by (P+As)-combined diffusion in zone-leveled and hot-pressed materials. The good overall understanding of doping mechanisms which has been achieved should enable optimization of the thermoelectric properties over this extended carrier concentration range. Reductions in thermal conductivity are being sought by introduction of very small phonon scattering centers (inert material) in the initial powders-precursors of Si-Ge alloys. This approach should benefit both n- and p-type materials.

Borshchevsky, Alex↗

Variable-speed Generators with Flux Weakening

A cost-competitive, permanent-magnet 20 kW generator is designed such that the following criteria are satisfied: an (over) load capability of at least 30 kW over the entire speed range of 60-120 rpm, generator weight of about 550 lbs with a maximum radial stator flux density of 0.82 T at low speed, unity power factor operation, acceptably small synchronous reactances and operation without a gear box. To justify this final design four different generator designs are investigated: the first two designs are studied to obtain a speed range from 20 to 200 rpm employing rotor field weakening, and the latter two are investigated to obtain a maximum speed range of 40 to 160 rpm based on field weakening via the stator excitation. The generator reactances and induced voltages are computed using finite element/difference solutions. Generator losses and efficiencies are presented for all four designs at rated temperature of Tr=120C.

Fardoun, A. A.↗

Lightweight linear alternators with and without capacitive tuning

Permanent magnet excited linear alternators rated tens of kW and coupled to free-piston Stirling engines are presently viewed as promising candidates for long term generation of electric power in both space and terrestrial applications. Series capacitive cancellation of the internal inductive reactance of such alternators was considered a viable way to both increase power extraction and to suppress unstable modes of the thermodynamic oscillation. Idealized toroidal and cylindrical alternator geometries are used for a comparative study of the issues of specific mass and capacitive tuning, subject to stability criteria. The analysis shows that the stator mass of an alternator designed to be capacitively tuned is always greater than the minimum achievable stator mass of an alternator designed with no capacitors, assuming equal utilization of materials ratings and the same frequency and power to a resistive load. This conclusion is not substantially altered when the usually lesser masses of the magnets and of any capacitors are added. Within the reported stability requirements and under circumstances of normal materials ratings, this study finds no clear advantage to capacitive tuning. Comparative plots of the various constituent masses are presented versus the internal power factor taken as a design degree of freedom. The explicit formulas developed for stator core, coil, capacitor, and magnet masses and for the degree of magnet utilization provide useful estimates of scaling effects.

Niedra, Janis M.↗

The Effect of Beam Loading on Water Impact Loads and Motions

An investigation of the effect of beam loading on impact loads and motions has been conducted in the Langley impact basin. Water impact tests of flat-bottom 5-inch-and 8-inch-beam models having beam-loading coefficients C(sub Delta) from 62.5 to 544 and a 30 deg dead-rise 5-inch-beam model A having beam-loading coefficients from 208 to 530 are described and the results analyzed to show trends of these heavy-beam-loading data with initial flight-path angle, trim angle, dead-rise angle, and time through- out the impact. Data from flat-bottom model tests, C(sub Delta) = 4.4 to 36.5, and from 30 deg dead-rise model tests, C(sub Delta) = 0.58 and 18.8, are included, along with the heavy-beam-loading data; and variations of these data with beam-loading coefficients are shown. Each of the load and motion coefficients is found to be directly proportional to a power factor of C(sub Delta). For instance, the maximum impact lift coefficient is found C(sub L,max) to be directly proportional to C(sub Delta, exp 0,33) for the flat-bottom model and C(sub Delta, exp 0,45) for the 30 deg dead-rise model. These variations of C(sub L, max) with C(sub Delta) are found to be in agreement with theoretical variations. Finally, an empirical equation for the prediction of C(sub L,max) is presented and is shown to give good agreement with experimental C(sub L, max) for about 500 fixed-trim smooth-water impacts. The range of variables included dead-rise angles from 0 deg to deg, beam-loading coefficients from o.48 to 544, trim angles from 3 deg to deg, and initial flight-path angles from about 2 deg to about deg.

Mixson, John S.↗

The Effect of Beam Loading on Water Impact Loads and Motions

An investigation of the effect of beam loading on impact loads and motions has been conducted in the Langley impact basin. Water impact tests of flat-bottom 5-inch- and 8-inch-beam models having beam-loading coefficients C(sub Delta) from 62.5 to 544 and a 30 0 dead-rise 5-inch-beam model A having beam-loading coefficients from 208 to 530 are described and the results analyzed to show trends of these heavy-beam-loading data with initial flight-path angle, trim angle, dead-rise angle, and time throughout the impact. Data from flat-bottom model tests, C(sub Delta) = 4.4 to 36.5, and from 300 dead-rise model tests, C(sub Delta)A = 0.58 and 18.8, are included, along with the heavy-beam-loading data; and variations of these data with beam-loading coefficients are shown. Each of the load and motion coefficients is found to be directly proportional to a power factor ofC(sub Delta). For instance, the maximum impact lift coefficient C(sub L,max)is found to be directly proportional to C(sub Delta)(sup 0.33) for the flat-bottom model and C(sub Delta)(sup 0.45) for the 30 deg dead-rise model. These variations of C(sub L,max) C(sub Delta) are found to be in agreement with theoretical variations. Finally, an empirical equation for the prediction of C(sub L,max) is presented and is shown to give good agreement with experimental C(sub L,max) for about 500 fixed-trim smooth-water impacts. The range of variables included dead-rise angles from 0 deg to 30 deg, beam-loading coefficients from 0.48 to 544, trim angles from 3 deg to 45 deg and initial flight-path angles from about 2 deg to about 27 deg.

Mixson, John S.↗

Motor Controller

M.H. Marks Enterprises' Power Factor Controller (PFC) matches voltage with motor's actual need. Plugged into a motor, PFC continuously determines motor load by sensing shifts between voltage and current flow. When it senses a light load, it cuts voltage to the minimum needed. It offers potential energy savings ranging from eight percent up to 65 percent depending on the application. Myles Marks started out with the notion of writing an article for Popular Electronics magazine at the same time offering to furnish kits to readers interested in assembling PFC's. Within two weeks from publication he had orders for 500 kits and orders are still coming three years later.

Source record↗

Wind Generators

When Enerpro, Inc. president, Frank J. Bourbeau, attempted to file a patent on a system for synchronizing a wind generator to the electric utility grid, he discovered Marshall Space Flight Center's Frank Nola's power factor controller. Bourbeau advanced the technology and received a NASA license and a patent for his Auto Synchronous Controller (ASC). The ASC reduces generator "inrush current," which occurs when large generators are abruptly brought on line. It controls voltage so the generator is smoothly connected to the utility grid when it reaches its synchronous speed, protecting the components from inrush current damage. Generator efficiency is also increased in light winds by applying lower than rated voltage. Wind energy is utilized to drive turbines to generate electricity for utility companies.

Source record↗

Big Savings from Smart Motors

Chesebrough-Pond's operates 32 plants across the nation and in those plants are more than 10,000 electric motors. In an effort to cut down on waste of electrical power used by these motors, Chesebrough organized a Corporate Advanced Technology Group to devise ways of improving productivity and cut manufacturing costs. Chesebrough used NASA's Marshall Space Flight Center's Power Factor Controller technology as a departure point for development of their own computerized motor controller that enables motors to operate at maximum efficiency regardless of the motor's applications or operating condition.

Source record↗

Power Controller

The power factor controller (PFC) senses shifts in the relationship between voltage and current, and matches them with a motor's need. This prevents waste as motors do not need a high voltage when they are not operating at full load conditions. PFC is manufactured by Nordic Controls Company, among others, and has proved extremely cost effective.

Source record↗