Search NASA⌕ Search

SEARCH · Search NASA

Results for “power output”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Power packet networks for wave energy converter arrays

One of the biggest challenges for all renewable energy sources (RES) is that they are variable power generators which will require reactive power or energy storage systems (ESS) to provide reliable power quality (ideally power factor of one) at the power grid generation side. The present invention is directed to a power packet network (PPN) for integrating wave energy converter (WEC) arrays into microgrids. Specifically, an array of WECs can be physically positioned such that the incoming regular waves will produce an output emulating an N-phase AC system such that the PPN output power is constant. ESS requirements are thereby minimized whilst maintaining grid stability with high power quality. This will enable RES integration onto a future smart grid for large-scale adoption and cost reduction while preserving high efficiency, reliability, and resiliency.

Wilson, David G.↗

Optimal Power Sharing Speed Compensation in On-road Wireless EV Charging Systems

Dynamic wireless charging of electric vehicles (EV) is an emerging technology with the potential to address range anxiety and reduce the size of batteries or provide charge-sustaining operation. Charging demand for dynamic wireless charging systems (DWCS) varies greatly in response to location-specific traffic behaviors including the number and speed of vehicles. This paper highlights the potential reduction of load variation with speed compensation and simulates opportunities to maximize the number of cars charged concurrently through “power sharing” or altering power output to slower cars while maintaining a maximum delivered energy. An improved sub-minute model for synthetic traffic is proposed to effectively model DWCS load on high speed roadways and a power electronics model is created based on an existing prototype developed by ORNL to investigate the potential for power sharing. Reductions in the average speed of traffic can greatly increase instantaneous DWCS load by as much as 26%, complicating capacity sizing. Parametric studies with a LCC-S power electronics model shows feasible power reduction of more than 20%, while maintaining a maximum achievable efficiency greater than 90%. Speed compensation on a roadway with large speed variation can reduce average power expected by 21% and increase the maximum number of cars charged simultaneously by 30%. The application of power sharing may significantly reduce load variability due to speed, allow for increased car hosting capability, and guarantee a maximum energy delivered.

Lewis, Donovin D.↗

Economically Viable Intermediate to Long Duration Hydrogen Energy Storage Solutions for Fossil Fueled Assets

This report was prepared as an account of work sponsored by the Office of Fossil Energy and Carbon Management of U.S. Department of Energy under Funding Opportunity Announcement Number DE-FOA-0002332 “Energy Storage for Fossil Power Generation”. The work aimed to explore and advance an innovative hydrogen energy storage system – the synergistically integrated hydrogen energy storage system (SIHES) – that has the following characteristics: • Compatible with existing or new coal and gas fuel electricity generation units, • best suited for intermediate to long duration energy storage, from 12 hours to weeks even months, and • capable of storing energy at the utility scale – hundreds of MWh to GWh energy storage with power output level in tens to hundreds of MW. Preliminary front-end engineering design (Pre-FEED) studies was carried out to develop and refine a site-specific SIHES as peaking power generation units (so named as HyPeaker) as the first market entry point, to demonstrate both the technical feasibility and the economic viability to integrate the HyPeaker “within the fence” of a fossil power plant. This specific site was TVA’s Johnsonville Combustion Turbine Plant. The HyPeaker was designed and engineered to integrate with a 60MW aeroderivative gas turbine unit already available at TVA’s Johnsonville site. This site-specific HyPeaker consists of an alkaline electrolyzer to produce hydrogen from CO 2 free electricity sources, an innovative low-cost high-pressure hydrogen storage system (Big-Ton) and the aero gas turbine to generate electricity using blend of hydrogen and natural gas. A holistic system level technoeconomic analysis tool specific to HyPeaker was developed to optimize the engineering design of the Johnsonville site-specific HyPeaker for cost and performance. The optimal design and specification of the Johnsonville site-specific HyPeaker are the following: • Alkaline electrolyzer: 3MW • Big-Ton storage vessel: 11,000kg H 2 at 3000psi. • 4-stage diaphragm hydrogen compressor: 55kg-H 2 /hr from 150psi to 3000psi. The HyPeaker is designed to provide sufficient hydrogen for 90% continuous operation of the HyPeaker. All major components have design life of 30 years. The capex of HyPeaker is estimated at $\$$7.1M. This included $\$$1.5M for the electrolyzer, $\$$5.6M for the storage vessel and compressor. The cost of aero gas turbine was included as it is already available at the site. Key findings are: • HyPeaker can be designed, manufactured, installed and integrated with the fossil power plants, with sub-systems and components commercially available on the market today, even when it is scaled up to an order of magnitude larger than the one at the Johnsonville site. HyPeaker is a technologically viable solution to cover a wide range of energy storage duration needs, from daily peaking operation to seasonal shifting for fossil fueled assets. • The cost advantage of SCCV based Big-Ton H 2 storage vessel made it possible to “oversize” the H 2 storage subsystem to achieve overall system level cost optimization. The benefits are two-fold. First, it allows to significantly reduce the capacity and cost of electrolyzer by spreading H 2 production over a much longer period of time when the fuel cost for electricity production is low. Second, it allows to balance the hydrogen production and usage shift over weeks to months to meet the peak demands. As such, the capital cost of HyPeaker system using the Big-Ton was less than half of the cost of a system with today’s steel tube based H 2 storage system. The HyPeaker has even better cost advantage Li-ion battery based energy storage system. The estimated capital cost of Li-Ion battery system would be at $\$$38M, under the same projected 20-year electricity generation profile of the Johnsonville site. This is over 5 times more expensive than the HyPeaker system. • Since industry scale energy storage systems do not have 100% energy conversion and storage efficiency, energy storage systems using fossil fuel generated electricity would increase the CO 2 emission. This is particularly the case for HyPeaker due to its low round trip efficiency. Therefore, a more sensible solution would be to the excessive or curtailed electricity from CO 2 emission free sources such as solar farms, wind farms or nuclear power plants, to produce hydrogen, and integrate them with the HyPeaker. Electricity from TVA’s nuclear power plants was used for the Johnsonville HyPeaker. • The economic viability of HyPeaker is expected to be further improved when global supply chains are taken into consideration. For the same Johnsonville site specific HyPeaker, the capex would be reduced to ~$\$$3.6M from ~$\$$7.1M, and the added LCOE is reduced to ~$\$$85/MWh. With the bipartisan Infrastructure Investment and Jobs Act, the cost of domestically produced HyPeaker sub-systems would be at the level of today’s global suppliers. Since the peaking units generally operate at peak usage period, thereby demanding higher price, the projected $\$$85/MWh LCOE would be within the realm of financial viability for utility operators.

08 HYDROGEN↗

Digital Twin Framework for the Resilient Remote Monitoring and Operation of Nuclear Microreactors

The nuclear industry is developing new advanced reactor technologies, and many companies are conceptualizing designs for microreactors, a class of nuclear reactor with a sub-20 MWth power output designed to be factory fabricated, easily transportable, and simple to control. Microreactors offer promising solutions to several use cases for which large-scale plants would not be suitable, and conventional power generation means, notably diesel electric generators, are expensive and logistically difficult. Many of the potential use cases are in isolated locations such as arctic communities, remote mines, and military installations. Therefore, the cost of microreactor deployment and traditional onsite operations pose a challenge that requires new technical solutions to address. One solution that has the potential to greatly improve economics is to operate and monitor microreactors remotely from a centralized location. Remote monitoring and operation are novel concepts to the nuclear industry and will greatly alter the tasks and responsibilities associated with current commercial nuclear power plant operators. As such, it is important to perform research on potential technological solutions and the impacts those solutions have on operations with end-goal of defining a safe and effective remote concept of operations. This paper proposes a framework for resilient remote operation of microreactors enabled by a novel digital twin implementation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Machine Learning-Driven Reliability Estimation of PV Inverters Considering Alert-Ambient Variability

Weather-induced spatio-temporal degradation limits outdoor PV inverter lifetime and reliability, necessitating advanced data analysis. This study employs a top-down, data-driven approach utilizing multiple machine learning (ML) algorithms to estimate inverter reliability in a 1.4 MW PV power plant, considering factors such as irradiance, humidity, temperature, time of day, and weather conditions. An extensive alert dataset from 17 identical inverters, including alert types, propagation, and frequency, reveals significant correlations with environmental factors and inverter output power, enabling the construction of a performance reliability model. Dual-stage supervised-ML models are evaluated for accuracy, with the ‘classification-regression’ model by an artificial neural network (ANN) tested on the averaged “Alert-Ambient” dataset, which is outperformed by ‘clustering-regression’ models using random forest (RF) and K-Nearest Neighbors (KNN) on individual inverter datasets. K-means clustering applies principal component analysis to reduce dimensions, achieving improved accuracy beyond the 80% achieved by ANN on the averaged dataset. Second-stage regression estimates inverter reliability with a mean square error of 0.0195 on the averaged dataset and as low as 0.002 on individual inverter datasets using RF. Furthermore, these findings highlight the method's suitability for estimating PV inverter output reliability under ambient conditions, essential for digital twin development and related applications.

14 SOLAR ENERGY↗

From Fundamental Interfacial Reaction Kinetics to Macroscopic Current–Voltage Characteristics: Case Study of Solid Acid Fuel Cell Limitations and Possibilities

The unique properties of solid acid electrolytes, in particular CsH 2 PO 4 , are in many ways ideal for fuel cell operation. However, the technology is constrained by high cathode overpotentials. Here a simplified cathode geometry is employed to obtain the fundamental electrochemical parameters (exchange current density and charge transfer coefficient) describing the oxygen reduction reaction (ORR) at the CsH 2 PO 4 -Pt-gas interface. The parameters are incorporated into a 1D model of the voltage–current characteristics of realistic SAFC cathodes, which reproduced the measured polarization behavior of such cathodes without recourse to fitting adjustable parameters. Following this validation, the model is utilized to evaluate the impact of changes to cathode properties, microstructure, and operating conditions. Of these, the charge transfer coefficient, measured to have a value of ≈0.6 for ORR on Pt in the SAFC cathode environment, is found to have the greatest impact on power output. Nevertheless, even without material modifications, a combination of microstructural and operational modifications are identified with projected performance metrics meeting Department of Energy targets (0.8 V at 300 mA cm –2 , and peak power density of 1 W cm –2 ), albeit at high Pt loadings. However, the analysis indicates that truly meaningful advances will likely necessitate the discovery of alternative ORR catalysts.

36 MATERIALS SCIENCE↗

Impact of Dry Cooler Air-Side Performance on a sCO2 Power Cycle for a CSP Application

Uncertainty around the design and control of the supercritical CO2 power cycle must be reduced before this technology can be implemented for large-scale grid support. To better understand the day-to-day performance of an sCO2 cycle, off-design performance calculations must be included for all power block components, and performance assumptions must be removed. This study has expanded the modeled scope to include the air-side performance for the dry cooler and has incorporated discretized heat transfer calculations for both streams through the pre-cooler to better predict off-design performance. This study considered a recompression Brayton cycle in a concentrating solar power application. The cycle model utilized fixed sCO2 turbomachinery maps for the main compressor, recompressor, and expander operating to supply approximately 10 MW gross at the design point. Fixed vendor-supplied fan curves were used to calculate the air-side performance of the dry cooler. The primary heater was modeled considering both the sCO2 and heat transfer fluid streams. Off-design performance was predicted for an ambient temperature range of 0-55℃, a HTF temperature range of 705-735℃, and a HTF mass flow range of 50-105% of the design point value. To understand the importance of modeling the air-side performance, the cycle off-design performance was also calculated using a constant CO2 outlet temperature assumption and a constant approach temperature assumption for the dry cooler. Results show that using these assumptions can significantly alter the power output and cycle efficiency predictions.

14 SOLAR ENERGY↗

Titanium-Cerium Electrode-Decoupled Redox Flow Batteries Integrated With Fossil Fuel Assets For Load-Following, Long-Duration Energy Storage

Operation of fossil plants at partial capacity with frequent cycling results in decreased efficiency, increased emissions and increased wear and maintenance. The objective of this project is to advance the integration of a titanium-cerium electrode-decoupled redox flow battery (RFB) system with conventional fossil-fueled power plants through technical and economic system-level studies and component scale-up and R&D. The Ti-Ce chemistry has a pathway to meet the DOE cost targets of $\$$100/kWh and $\$$0.05/kWh-cycle owing to the use of low-cost, earth abundant elemental actives and incorporation of inexpensive carbon felt electrodes and non-fluorinated anion exchange membrane (AEM) separators. The initial unit cell design was scaled up, with some modifications made to improve ease of manufacturing, from 25 cm 2 cell area to 400 cm 2 . Electrochemical tests demonstrated operation at a current density up to 50 mA/cm 2 , which is on par with other commercial RFB offerings. Furthermore, the Ti-Ce technology developed by WashU was evaluated and tested by industrial team partner, Giner, Inc., in their modular 3-cell stack. Several cell design modifications and alternate component material selections were successfully implemented to accommodate this chemistry while reducing polarization and leakage. Results from stack testing show high columbic efficiency and indicate that further optimization of cell compression and components will lead to successful operation of the Ti-Ce ED-RFB over longer duration at the multi-cell stack level. Engineering and cost analysis showed that an RFB system with power output on the order of 100 MW and with a charge/discharge duration of approx. 12 hours is the most cost effective for integration with fossil plants. At this scale, projected cycling of fossil fuel power plants can be significantly reduced. The use of a storage system is shown to reduce the fossil plant standalone cost of electricity by $\$$7/MWh, through increased capacity factor and improved average efficiency, in the scenario of high penetration of renewable power.

20 FOSSIL-FUELED POWER PLANTS↗

Data-Driven Affinely Adjustable Robust Volt/VAr Control

Recent years have seen the increasing proliferation of distributed energy resources with intermittent power outputs, posing new challenges to the voltage management in distribution networks. To this end, this paper proposes a data-driven affinely adjustable robust Volt/VAr control (AARVVC) scheme, which modulates the smart inverter’s reactive power in an affine function of its active power, based on the voltage sensitivities with respect to real/reactive power injections. To achieve a fast and accurate estimation of voltage sensitivities, we propose a data-driven method based on deep neural network (DNN), together with a rule-based bus-selection process using the bidirectional search method. Our method only uses the operating statuses of selected buses as inputs to DNN, thus significantly improving the training efficiency and reducing information redundancy. Finally, a distributed consensus-based solution, based on the alternating direction method of multipliers (ADMM), for the AARVVC is applied to decide the inverter’s reactive power adjustment rule with respect to its active power. Only limited information exchange is required between each local agent and the central agent to obtain the slope of the reactive power adjustment rule, and there is no need for the central agent to solve any (sub)optimization problems. Finally, numerical results on the modified IEEE-123 bus system validate the effectiveness and superiority of the proposed data-driven AARVVC method.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Biconjugate Impedance Matching Control of the HERO WEC: Preprint

Effective control strategies are essential for maximizing the power output of wave energy converters (WECs). In this study, we explore the methodology of port-based modelling which can be used for bi-conjugate impedance matching, a type of reactive control that involves maximizing power transfer by setting the load (PTO) impedance to be the complex conjugate of the source impedance (WEC). Despite its foundational role in electrical engineering, this method has seen limited application in wave energy and has not yet been demonstrated in wave-powered desalination systems. We represent our complex multidisciplinary system as an equivalent circuit to explore frequency-based relations. The HERO WEC, a small-scale, modular point absorber (PA) designed for reverse osmosis desalination is used as a case study to demonstrate port-based modelling for control applications. Improving the performance of wave-powered water desalination systems could play a critical role in addressing freshwater scarcity for coastal communities, especially those in remote or disaster-prone regions.

16 TIDAL AND WAVE POWER↗

Dielectric Engineering of ZnO@ZIF‐8 for High‐Performance Triboelectric Nanogenerators and Self‐Powered Humidity Sensors

Porous metal oxide–metal-organic framework (MO x @MOF) hybrids offer synergistic effects that enhance surface charge density, electronic structure, and textural properties, making them ideal for self-powered sensing applications. Here, uniform, and pinhole-free ternary porous ZnO–PTFE@ZIF-8 hybrid films are developed on room-temperature co-sputtered ZnO–polytetrafluoroethylene (PTFE) composite films, where ZnO serves as a self-sacrificial precursor to precisely regulate ZIF-8 (Zn-MeIm 2 ) growth through solvothermal methods. The resulting TENG achieves a high output power density of 0.67 mW cm −2 , attributed to the synergistic effects of fluorine-rich PTFE and methyl-functionalized ZIF-8, which enhance surface charge density and dielectric response. By tuning PTFE content in the ZnO–PTFE composite, the dielectric constant and triboelectric output is optimized. The ZP60@ZIF-8-based device also demonstrates excellent humidity sensing performance, with a wide detection range (20–99% RH) and ultrahigh sensitivity (R V % of 19 900%, R I % of 19 325% at 99% RH). These results position ZP@ZIF-8-based TENGs as promising platforms for next-generation self-powered sensors and smart wearable electronics.

42 ENGINEERING↗

Three-Phase LCC-LCC Compensated 50-kW Wireless Charging System with Non-Zero Interphase Coupling

In this paper, an LCC-LCC compensated 50 kW 3phase (3φ) wireless charging system with nonzero interphase mutual inductance is demonstrated. The 3φ-LCC compensation is designed considering a nonzero mutual-inductance among the phase-coils to meet resonance criteria, balance voltages and currents of the resonant tank components, achieve desired voltage gain, and ensure the zero-voltage switching (ZVS) operation. An experimental prototype of the 3φ-LCC-LCC compensation circuit is built for a 50 kW bipolar coil-based 3φ wireless charging system. The prototype system was tested at rated 50 kW power for evaluating the efficiency, ZVS operation, electric and magnetic field emissions, and thermal characteristics. The experimental results show 94.3% dc-to-dc efficiency and only 4.4 μT rms magnetic field emission at the rated 50 kW output power.

Mohammad, Mostak↗

Small Scale WEC Performance Modeling Data

Small Scale WEC Performance Modeling Data is performance data from downscaled models of common WEC devices and their calculated performance outputs. This data is used by the Small WEC interactive modeling tool hosted by PRIMRE. The devices include a point absorber, a two-body point absorber (RM3), an oscillating surge device (OSWEC), and an attenuator type device (McCabe Wave Pump). One of the primary use cases for this work is to give an easy way to compare power output for a variety of WECs and model sizes.

16 TIDAL AND WAVE POWER↗

A 20-kW DC Oak Ridge Converter with Integrated AC & DC Sources for Grid Services and Energy Storage Systems

This paper proposes a wireless power transfer (WPT) platform with integrated energy conversion that has the capability for 1) recharging the energy storage systems (ESSs) from the grid systems, including renewable energy sources such as wind, solar, etc., 2) off grid systems recharging the ESSs from dc grid systems, 3) grid recharging of electric vehicles (EVs), and 4) off grid recharging of EVs from ESSs. The unique aspect of the method is the use of multi-interface power electronic converter for the grid and ESSs and EVs that can support a range of applications with ac / dc and dc / dc energy conversion ability in a single converter system. The key enabling technology to achieve these functionalities is Oak Ridge Converter (ORC) with polyphase coupler coil system both developed at ORNL. This new technology enables higher power density WPT systems while allowing the coils to interface from ac grid at 60 Hz frequency or dc source directly merging with 85 kHz operating frequency of switching component. The experimental results of the proposed system are presented for 20 kW output power with the system overall efficiency around 95.4% from dc source and 93% overall efficiency from ac grid achieving 9-10% current total harmonic distortion (THD) and 0.98-0.99 power factor (PF).

Asa, Erdem↗

Stabilization of high-performance rock-salt LiMnSbTe3 thermoelectrics with embedded van der Waals-like gaps

Rock-salt-structured compounds like lead chalcogenides are promising thermoelectrics, as their high symmetry, strong anharmonicity, and favorable phase behavior collectively lead to high performance by enabling large power factors and ultralow thermal conductivity. Here, we report LiMnSbTe 3 , a new rock-salt semiconductor stabilized through targeted chemical design by combining hexagonal MnTe with cubic LiSbTe 2 . Embedded in the highsymmetry matrix, van der Waals-like gaps form due to Sb 2 Te 3 nanoscale segregation, which acts as effective phonon-scattering centers, leading to a low lattice thermal conductivity of 0.37Wm- 1 K -1 at 873 K with alloy scattering from disordered cations. The ordered local structure of Sb2Te 3 -type vdW-like gaps and the cross-gap interaction facilitate the carrier transport. Aided by energyconverged valence bands and a paramagnon drag effect, high Seebeck coefficients and enhanced power factor can be achieved, leading to a high ZT of 1.2 at 873 K. Furthermore, introducing Mn deficiency increases ZT to 1.5, highlighting the potential for higher performance through optimized doping or alloying. A segmented single-leg thermoelectric module achieves an output power density of 0.52 Wcm -2 and an efficiency of 8.7% under ΔT of 478 K, further demonstrating its promising thermoelectric applications.

42 ENGINEERING↗

Probabilistic Day-Ahead Forecasting Using an Analog Ensemble Approach for Wind Farm Grid Services

Wind resource assessment and wind power forecasting are used in research and industry to anticipate future power output at scales ranging from individual wind turbines to entire wind farms. Probabilistic day-ahead wind forecasting is useful for anticipating how a wind farm could potentially participate in the day-ahead market by providing upper and lower bounds for expected power generation, thus informing grid operators of its uncertainty. Understanding this uncertainty is part of a larger project focused on building a platform that combines efforts in weather forecasting, aerodynamic and economic modeling to create maximum value of a wind plant to better provide services to the grid. This effort is also known as the Atmosphere to Electrons to Grid (A2E2G) project. One method for producing a probabilistic forecast is through the analog ensemble approach (Delle Monache et al., 2011). This method leverages historical forecasts and their corresponding observations as a training data set from which future forecasts can be made. For some future forecast, the most similar historical forecasts (analogs) are identified on a regular time basis such as once per a 3-hour window. The most similar analogs, based on a metric such as root mean square error (RMSE), are recorded and their corresponding verifying observations are used as an ensemble member for this future forecast. Prior work in this area demonstrates improvements over raw Numerical Weather Prediction (NWP) forecasts and shows skill similar to techniques such as logistic regression and machine learning (Delle Monache et al., 2013; Alessandrini et al., 2015). Here, we take the High-Resolution Rapid Refresh model (HRRR) day-ahead forecast (0-36 hours) to create a probabilistic day-ahead forecast using an analog ensemble approach. The HRRR has an hourly temporal resolution, with a spatial resolution of 3 km. The 12 UTC HRRR model run is downloaded every day for one year from August 2019 - July 2020, with the first 11 months serving as a bank of analogs from which the forecasting algorithm can create a probabilistic forecast. Once downloaded, the original HRRR forecast is temporally interpolated to 5-minutes, aligning with both the temporal resolution of the observations as well as the timescale relevant for day-ahead power forecasts. The forecast is validated at the M2 tower at the Flatirons Campus of the National Renewable Energy Laboratory (NREL) at a typical wind turbine height of 80 m. Variables such as wind speed, wind direction, and turbulence intensity are incorporated into the probabilistic forecast model and weighted according to their relative importance to the forecast. Based on metrics such as mean bias error (MBE), mean absolute error (MAE), and root mean square error, the analog ensemble forecast outperforms the raw HRRR forecast during the testing period of July 2020. Figure 1 illustrates an example day-ahead forecast compared against the verifying observations. The general variability and ramps are captured throughout the day, with potential to further improve the analog ensemble model through machine learning techniques.

numerical weather prediction↗

An innovative SR-WEC for a market-disruptive LCOE

The objective of DE-EE0008630: An innovative SR-WEC for a market-disruptive LCOE was to develop and test a scaled prototype of the Surface-Riding Wave Energy Converter that can result in a market-disruptive Levelized Cost of Energy by a combination of an extended operating window, substantially lowered cost and amplified average power output by simple optimum control. Initially conceptualized as a floating linear electrical generator (LEG), the SR-WEC evolved into an intermediate-scale version where multiple LEGs were mounted on a floating cylindrical body, driven by the need to enhance scalability and improve power performance.

16 TIDAL AND WAVE POWER↗

A Novel Three-Phase Isolated LLC and Non-Isolated LCL-T Resonant Converter for Fuel Cell Applications

In this paper, a novel three-phase isolated LLC and non-isolated LCL−T resonant converter topologies are introduced for fuel cell applications. In order to improve the fuel cell DC/DC converter efficiency, the current amplitude should be reduced in the power stage components. Cascaded connections of fuel cell blocks through a controllable system enable using higher voltage amplitude and bring the current amplitude lower at the target power. In this way, power losses in the passive components can be reduced, and maximum energy transfer can be established, improving the DC/DC converter efficiency from the fuel cell to the load. The introduced new converter also achieves soft switching (ZVS), minimizing the switching losses in all input and output load conditions. The presented three-phase isolated LLC and non-isolated LCL−T resonant converter systems, fed by three fuel cell modules with an output range of 190380 V, deliver 580−730 V at 450 kW maximum output power. The results reveal that the proposed systems have the advantage of reducing the size, volume, and weight and increasing the overall DC/DC converter system efficiency compared to the single-phase systems.

Asa, Erdem [ORNL] (ORCID:0000000190884812)↗