Benefits of Application of Advanced Technologies for a Neptune Orbiter, Atmospheric Probes and Triton Lander

Missions with planned launch dates several years from today pose significant design challenges in properly accounting for technology advances that may occur in the time leading up to actual spacecraft design, build, test and launch. Conceptual mission and spacecraft designs that rely solely on off the shelf technology will result in conservative estimates that may not be attractive or truly representative of the mission as it actually will be designed and built. This past summer, as part of one of NASA s Vision Mission Studies, a group of students at the Laboratory for Spacecraft and Mission Design (LSMD) have developed and analyzed different Neptune mission baselines, and determined the benefits of various assumed technology improvements. The baseline mission uses either a chemical propulsion system or a solar-electric system. Insertion into orbit around Neptune is achieved by means of aerocapture. Neptune s large moon Triton is used as a tour engine. With these technologies a comprehensive Cassini-class investigation of the Neptune system is possible. Technologies under investigation include the aerocapture heat shield and thermal protection system, both chemical and solar electric propulsion systems, spacecraft power, and energy storage systems.

Somers, Alan↗

Space Environment Testing of Photovoltaic Array Systems at NASA's Marshall Space Flight Center

CubeSats, Communication Satellites, and Outer Planet Science Satellites all share one thing in common: Mission success depends on maintaining power in the harsh space environment. For a vast majority of satellites, spacecraft power is sourced by a photovoltaic (PV) array system. Built around PV cells, the array systems also include wiring, substrates, connectors, and protection diodes. Each of these components must function properly throughout the mission in order for power production to remain at nominal levels. Failure of even one component can lead to a crippling loss of power. To help ensure PV array systems do not suffer failures on-orbit due to the space environment, NASA's Marshall Space Flight Center (MSFC) has developed a wide ranging test and evaluation capability. Key elements of this capability include: Testing: a. Ultraviolet (UV) Exposure b. Charged Particle Radiation (Electron and Proton) c. Thermal Cycling d. Plasma and Beam Environments Evaluation: a. Electrostatic Discharge (ESD) Screening b. Optical Inspection and easurement c. PV Power Output including Large Area Pulsed Solar Simulator (LAPSS) measurements This paper will describe the elements of the space environment which particularly impact PV array systems. MSFC test capabilities will be described to show how the relevant space environments can be applied to PV array systems in the laboratory. A discussion of MSFC evaluation capabilities will also be provided. The sample evaluation capabilities offer test engineers a means to quantify the effects of the space environment on their PV array system or component. Finally, examples will be shown of the effects of the space environment on actual PV array materials tested at MSFC.

Schneider, Todd A.↗

Adaptive Protection and Control for High Penetration PV and Grid Resilience (Final Technical Report)

The report summarizes the work and accomplishments of DOE SETO funded project 36533 “Adaptive Protection and Control for High Penetration PV and Grid Resilience”. In order to increase the amount of distributed solar power that can be integrated into the distribution system, new methods for optimal adaptive protection, artificial intelligence or machine learning based protection, and time domain traveling wave protection are developed and demonstrated in hardware-in-the-loop and a field demonstration.

14 SOLAR ENERGY↗

Chemical vapor deposited silica coatings for solar mirror protection

A variety of techniques is available to apply protective coatings to oxidation susceptible spacecraft components, and each has associated advantages and disadvantages. Film applications by means of chemical vapor deposition (CVD) has the advantage of being able to be applied conformally to objects of irregular shape. For this reason, a study was made of the oxygen plasma durability of thin film (less than 5000 A) silicon dioxide coatings applied by CVD. In these experiments, such coatings were applied to silver mirrors, which are strongly subject to oxidation, and which are proposed for use on the space station solar dynamic power system. Results indicate that such coatings can provide adequate protection without affecting the reflectance of the mirror. Scanning electron micrographs indicated that oxidation of the silver layer did occur at stress crack locations, but this did not affect the measured solar reflectances. Oxidation of the silver did not proceed beyond the immediate location of the crack. Such stress cracks did not occur in thinner silica flims, and hence such films would be desirable for this application.

Gulino, Daniel A.↗

Chemical vapor deposited silica coatings for solar mirror protection

A variety of techniques is available to apply protective coatings to oxidation susceptible spacecraft components, and each has associated advantages and disadvantages. Film applications by means of chemical vapor deposition (CVD) has the advantage of being able to be applied conformally to objects of irregular shape. For this reason, a study was made of the oxygen plasma durability of thin film (less than 5000 A) silicon dioxide coatings applied by CVD. In these experiments, such coatings were applied to silver mirrors, which are strongly subject to oxidation, and which are proposed for use on the space station solar dynamic power system. Results indicate that such coatings can provide adequate protection without affecting the reflectance of the mirror. Scanning electron micrographs indicated that oxidation of the silver layer did occur at stress crack locations, but this did not affect the measured solar reflectances. Oxidation of the silver did not proceed beyond the immediate location of the crack. Such stress cracks did not occur in thinner silica films, and hence such films would be desirable for this application.

Gulino, Daniel A.↗

Packing the PLSS

NASA Engineers design spacesuits for ultimate protection and functionality in the extreme environment of space. The spacesuit is often referred to as a "personal spacecraft" because it provides the astronaut with everything he or she needs to survive and work in space outside of the vehicle or habitat. The systems within the spacesuit include the pressure garment system (PGS), the Portable Life Support System (PLSS), and the power, avionics, and software (PAS) system. These elements are necessary to protect crewmembers and allow them to work effectively in the pressure and temperature extremes of space environments. Development of the spacesuit system is necessary to support future human extravehicular exploration activities to Lunar, Martian, microgravity, and possibly other space destinations. Although all the systems that makeup the space suit are important, the PLSS is one of the most complex. The PLSS provides the life support needed by the astronaut and consists of the oxygen (O2) subsystem, ventilation subsystem, and thermal control subsystem. Within each subsystem, there are many different components, a few of which are explained as follows. The oxygen tanks hold the oxygen that the crewmember uses to breath and pressurizes the suit. The primary oxygen tank is responsible during normal operations and the secondary oxygen tank kicks on in the case of an emergency. The Rapid Cycle Amine (RCA) canister is used to remove the carbon dioxide (CO2) and extra humidity in the crewmember's ventilation/breathing gas. The fan moves the oxygen around the suit. Suit Water Membrane Evaporator (SWME) is used within the thermal control loop to cool the water that is used to maintain a comfortable temperature for both the crew member and the other equipment inside the suit. Another component is the battery, which supplies the power needed to operate all these and the many other pieces. The battery is one of the biggest and heavies components within the PLSS. These are just a few of the components that encompass the PLSS. Each component has a weight and a certain volume that the NASA Engineers must take into account when building the PLSS, because the weight and volumes affect the crewmembers center of gravity (CG). [See the Notes Section for the link to an Apollo video that demonstrates the issues some of the crewmembers had picking up tools and dealing with center of gravity/tools on the surface of the Moon.] In this activity, students will simulate engineering design techniques that NASA Engineers and Designers are currently implementing to configuring the components within the PLSS. Through testing, students will consider the comfort, mobility, and center of gravity for their test subjects and how that changes after adjusting the placement of their simulated PLSS components.

Jennings, Mallory↗

Modeling Distributed Energy Resources for Analyzing Distribution Systems with High Renewable Penetration: Preprint

Increasing levels of inverter-based distributed energy resources (IBDERs) impact the legacy overcurrent distribution protection systems. The fault current injections of IBDERs are limited to between 1-2 p.u. of the rated current. The combination of the limited fault current and varying system load makes it increasingly difficult to reliably set the overcurrent protection. To address this challenge, researchers are proposing adaptive overcurrent protection mechanisms that can adapt to changing system conditions. Accurate modeling of IBDERs is required to develop reliable protection schemes. This paper presents a photovoltaics-based IBDER model in OpenDSS for adaptive overcurrent protection. The paper presents the validation of the proposed IBDER model against a detailed model in electromagnetic transient programs. Protection analysis of the Electric Power Research Institute J1 feeder with the proposed IBDER model is also presented.

adaptive↗

Electrical Fault Detection, Power Quality, Distributed Energy Resource Use Cases, and Cyber Event Applications with the Cyber Grid Guard System Using Distributed Ledger Technology

Electrical utilities continue to deploy more intelligent electronic devices (IEDs) inside and outside electrical substation and are associated with distributed energy resources (DERs). The integrity and confidentiality of data from IEDs is crucial, and distributed ledger technology (DLT) could improve the resilience of microgrids by helping to make these data more secure. The most popular applications using blockchain technology for electrical utilities is in the field is based on energy trading. However, the dynamism of the penetration of customer owned DERs and the deployment of sensors with IEDs have led to the identification of new applications using DLT that are focused on other areas, such as monitoring, operation and management of the grid and its assets. In addition, the majority of studies on electrical grid applications with blockchain were validated with software simulations. Although general monitoring of power systems for using DLT could be evaluated in operational electric grids, other DLT research applications such as defense against cyber-attacks and/or electrical fault detection are not likely to be performed in a real infrastructure because of possible risks to the network/equipment security. This report summarizes the application of power system applications using distributed ledger technology (DLT), providing a secure DLT framework for collecting data from IEDs like power meters and protective relays inside and outside of an electrical substation and/or between two different electrical utilities. In this study, the use case scenarios were created and assessed for different power system application by using DLT. The electrical fault detection for faulted phases (1), power quality monitoring of phase voltage magnitudes, frequency levels and load power factor (2), DERs use case monitoring (3), and cyber-event applications (4) were performed in a test bed with a Cyber-Grid Guard (CGG) system using DLT. It had a real-time simulator with power meters and protective relays in-the-loop. The first section of this report presents a literature review of power system applications using blockchain at research level. The second section shows the theory and equations used on this report. The third section shows the description of the test bed, equipment, architecture, and electrical grid diagrams. The fourth section shows the experimental models and use case scenarios that were performed for the electrical fault detection, power quality, DERs use case, and cyber event applications with the CGG system using DLT. The fifth section shows the results collected from the tests based on comparing the time stamped events of the analog signals from the IEDs, DLT computer and real time simulator. The sixth section performed the discussion of the results for the use case scenarios. Finally, section seven presents the conclusions for this report were presented.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Performance Evaluation of a Novel Sequence-Based Directional Detection Strategy for Protection of Active Distribution Networks

Directional elements are relied on to achieve selectivity in fault detection in power systems. Although such elements have been deployed successfully for many years, there is an increased need for novel methods to deal with the unique challenges of directional protection in modern distribution networks. This article analyzes the impact of inverter-based resources (IBRs) on existing directional protection methods in distribution systems. It identifies parts of such elements that pose a risk of misoperation when IBRs are used in distribution networks. The authors have developed a new directional detection method for unbalanced faults in such networks using superimposed symmetrical sequence quantities. The phase angle of the superimposed negative sequence admittance is used to determine fault direction. The paper also presents a real-time co-simulation platform between a simulated distribution system and physical protection relay, using OPAL-RT. An SEL-411L relay is used to program the detection algorithm. This hardware-in-the-loop (HIL) setup is used to verify the performance of the method and the results are compared with existing directional methods

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Generic and Multi-Functional Electromagnetic Transient Model for Grid-Following Inverter: Preprint

This article presents a generic and multi-functional electromagnetic transient (EMT) dynamic model of grid following (GFL) inverter-based resource (IBR) using the PSCAD TM software platform. The features of the developed model includes the flexibility in selecting various types and combinations of DC sources covering PV modules, battery modules, ideal DC source module, as well as flexibility in selecting either switched or averaged model of inverter. This model also covers exhaustive lists of controller logic covering open-loop/closed-loop PQ dispatch control, DC voltage and AC terminal voltage control along with the conventional current control designed in dq-domain, aB- domain and positive-negative sequence domain. Moreover, this model is equipped with the flexibility in selecting various types of current limiting schemes that includes saturation-based as well as latching-based current limiter, anti-windup protection. Moreover, the EMT model is agnostic to the MVA rating and is suitable for interfacing transmission systems by being complaint with the IEEE Std. 2800. The generality in the power circuits and the multi-functional options in operation and control of the developed EMT model makes it suitable for both academia and industry to study various power system aspects not limited to but such as fault behavior of GFL IBR and impacts on protection system, transient stability of a system interfaced with large number of GFL IBRs etc.

grid following inverter↗

PRIME: a real-time cyber-physical systems testbed: from wide-area monitoring, protection, and control prototyping to operator training and beyond

As the power grid continues to evolve with advanced wide-area monitoring, protection, and control (WAMPAC) algorithms, there is an increasing need for realistic testbed environments with industry-grade software and hardware-in-the-loop (HIL) to perform verification and validation studies. Such testbed environments serve as ideal platforms to perform WAMPAC prototyping, operator training, and also to study the impacts of different types of cyberattack scenarios on the operation of the grid. In this paper, we introduce PRIME (PNNL cybeR physIcal systeMs tEstbed): the testbed that integrates real-time transmission system simulator with commercial industry grade energy management system (EMS) software and remote hardware-in-the-loop (RHIL). PRIME is an end-to-end, modular testbed that allows high-fidelity RHIL experimentation of a power system. We present two detailed case studies (fault location and clearing in transmission system, and operator training) to showcase the capabilities of our PRIME testbed. Finally, we briefly discuss some of the potential limitations of our testbed in terms of scalability and flexibility to setup larger test systems and identify directions for future work to address those limitations.

42 ENGINEERING↗

Strain Monitoring of Flexible Structures

One of the biggest challenges facing NASA's deep space exploration goals is structural mass. A long duration transit vehicle on a journey to Mars, for example, requires a large internal volume for cargo, supplies and crew support. As with all space structures, a large pressure vessel is not enough. The vehicle also requires thermal, micro-meteoroid, and radiation protection, a navigation and control system, a propulsion system, and a power system, etc. As vehicles get larger, their associated systems also get larger and more complex. These vehicles require larger lift capacities and force the mission to become extremely costly. In order to build large volume habitable vehicles, with only minimal increases in launch volume and mass, NASA is developing lightweight structures. Lightweight structures are made from non-metallic materials including graphite composites and high strength fabrics and could provide similar or better structural capability than metals, but with significant launch volume and mass savings. Fabric structures specifically, have been worked by NASA off and on since its inception, but most notably in the 1990's with the TransHAB program. These TransHAB developed structures use a layered material approach to form a pressure vessel with integrated thermal and micro-meteoroid and orbital debris (MMOD) protection. The flexible fabrics allow the vessel to be packed in a small volume during launch and expand into a much larger volume once in orbit. NASA and Bigelow Aerospace recently installed the first human-rated inflatable module on the International Space Station (ISS), known as the Bigelow Expandable Activity Module (BEAM) in May of 2016. The module provides a similar internal volume to that of an Orbital ATK Cygnus cargo vehicle, but with a 77% launch volume savings. As lightweight structures are developed, testing methods are vital to understanding their behavior and validating analytical models. Common techniques can be applied to fabric materials, such as tensile testing, fatigue testing, and shear testing, but common measurement techniques cannot be used on fabric. Measuring strain in a material and during a test is a critical parameter for an engineer to monitor the structure during the test and correlate to an analytical model. The ability to measure strain in fabric structures is a challenge for NASA. Foil strain gauges, for example, are commonplace on metallic structures testing, but are extremely difficult to interface with a fabric substrate. New strain measuring techniques need to be developed for use with fabric structures. This paper investigates options for measuring strain in fabric structures for both ground testing and in-space structural health monitoring. It evaluates current commercially available options and outlines development work underway to build custom measurement solutions for NASA's fabric structures.

Litteken, Douglas A.↗

Thermionic reactor power system: Effects of radiation on integration with Manned Space Station

The application of a thermionic reactor power system to the modular space station is described. The nominal net power is 40 kWe, with the power system designed to be applicable over the power range from 25 to 60 kWe. The power system is designed to be launched by the space shuttle. Radiation protection is provided by LiH neutron shielding and W gamma shielding in a shaped 4 pion configuration, i.e., the reactor is shielded on all sides but not to equal extent. Isodose contours are presented for the region around the modular space station. Levels and spectral distribution of radiation are given for later evaluation of effects on space station experiments. Parametric data on the effects of separation distance on power system mass are presented.

Gietzen, A. J.↗

Envisioning the Future Renewable and Resilient Energy Grids—A Power Grid Revolution Enabled by Renewables, Energy Storage, and Energy Electronics

Today’s power grids are facing tremendous challenges because of the ever-increasing power demand, system complexity, infrastructure cost, knowledge base, and policy and regulatory issues to achieve supply–demand power balance and resiliency with respect to more frequent extreme weather events and cyberattacks. It is particularly challenging when the transition toward 100% intermittent renewable energy sources is considered. Many countries are calling for building up more transmission and distribution lines to increase power delivery capacities. This article is an attempt to answer two urgent questions: Is more transmission and distribution infrastructure really needed to meet the increasing power demand? What kind of future grid infrastructure should we envision and build? This article attempts to answer these questions and proposes the concept of community-centric asynchronous renewable and resilient energy grids. By clearly differentiating the concepts of grid resilience and reliability, the importance of building resilient power electronics’ devices and robust system-level control algorithms to achieve 100% renewable energy integrated resilient grids is presented. To identify the shortcomings and propose advancements, power electronics’ technologies are categorized using the proposed concepts of natural source frequencies (NSf), energy storage, direct energy conversion/control and fault protection (DeCaFp), and high-efficiency energy consumption and buffering (heECaB) technology. The ability of networked microgrids to greatly reduce power outages and power system restoration time is demonstrated by leveraging robust decentralized and centralized control algorithms, identified through a comprehensive literature review. Future research areas are proposed to further enhance grid stability, controllability, cybersecurity, and protection against faults in the presence of 100% renewable sources by leveraging the advanced capabilities of NSf, DeCaFp, and heECaB devices and system-level control algorithms.

14 SOLAR ENERGY↗

Securing Inverter Communication: Proactive Intrusion Detection and Mitigation System to Tap, Analyze, and Act

The electric grid has undergone rapid, revolutionary changes in recent years; from the addition of advanced smart technologies to the growing penetration of distributed energy resources (DERs) to increased interconnectivity and communications. However, these added communications, access interfaces, and third-party software to enable autonomous control schemes and interconnectivity also expand the attack surface of the grid. To address the gap of DER cybersecurity and secure the grid-edge to motivate a holistic, defense-in-depth approach, a proactive intrusion detection and mitigation system (PIDMS) device was developed to secure PV smart inverter communications. The PIDMS was developed as a distributed, flexible bump-in-the-wire (BITW) solution for protecting PV smart inverter communications. Both cyber (network traffic) and physical (power system measurements) are processed using network intrusion monitoring tools and custom machinelearning algorithms for deep packet analysis and cyber-physical event correlation. The PIDMS not only detects abnormal events but also deploys mitigations to limit or eliminate system impact; the PIDMS communicates with peer PIDMSs at different locations using the MQTT protocol for increased situational awareness and alerting. The details of the PIDMS methodology and prototype development are detailed in this report as well as the evaluation results within a cyber-physical emulation environment and subsequent industry feedback.

14 SOLAR ENERGY↗

Computational Heat Flux Analysis for HEATheR Electric Aircraft Wing Ice Protection Systems

Increased electrification of aircraft systems, a growing trend in the aircraft industry, affects subsystems that have historically been pneumatically driven by the engine. Optimized design of propulsion and power systems must account for the requirements of these subsystems. One such subsystem, the wing ice protection system, is the focus of this paper. A preliminary computational icing analysis has been conducted using the LEWICE and ANSYS FENSAP-ICE software to characterize the requirements of a thermal ice protection system for three More Electric Aircraft concepts. This paper summarizes the methodology, simulation execution, and icing conditions used for the analysis as well as discusses the results, observed trends, and impacts to system design. This initial analysis indicates that the computed heat requirements for the wing ice protection systems are not within the capabilities of known traditional systems. A discussion of potential methods for reducing the heat flow requirement by the ice protection system is included. Potential refinements to the analysis to improve the accuracy are also discussed.

Nic Heersema↗

Cybersecurity at the Grid Edge: Protecting LA's Energy Systems in a Connected World

Join SoCalGas and the National Laboratory of the Rockies (NLR) for an insightful webinar on securing operational technology and energy systems. Los Angeles has the second-largest metro by population in the nation, making it vital to protect the energy infrastructure that powers day-to-day life. However, cybersecurity for energy systems is an immense challenge due to an increasing number of interconnected devices and stakeholders. While there was traditionally a limited need to secure energy infrastructure, the grid is only becoming smarter and more software-defined. Amid aging infrastructure and evolving cyber threats, the need to ensure the security of energy is at an all-time high. Together, SoCalGas and NLR are assessing the current state-of-the-art of the energy ecosystem to understand gaps in current best practices and technologies relevant to powering the city of Los Angeles.

97 MATHEMATICS AND COMPUTING↗