Criticality of Inverter Controller Order in Power System Dynamic Studies – Case Study: Maui Island
Not Available
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not Available
The primary objective of a power system is to safely provide reliable energy services to society at an affordable cost. In many countries, this objective has been supplemented by another: meeting the energy demand with sustainable resources, which has culminated in the energy transition to low-carbon and zero-carbon energy systems. This transition, occurring rapidly around the world, is characterized by the increasing penetration of variable renewable energy (VRE), inverter-based resources (IBRs), and distributed energy resources (DERs).
To enable next-generation high power, high-energy-density lithium (Li) metal batteries (LMBs), an electrolyte possessing both high Li Coulombic efficiency (CE) at high-rate and good anodic stability on cathodes is critical. Acetonitrile (AN) is a well-known organic solvent for high anodic stability and high ionic conductivity, yet its application in LMBs is limited due to its poor compatibility with Li metal anode even at high salt concentration conditions. Here, we developed a highly concentrated AN-based electrolyte with vinylene carbonate (VC) additive to suppress Li+ depletion at high current densities. Addition of VC in the AN-based electrolyte leads to the formation of a polycarbonate-based solid electrolyte interphase which minimizes Li corrosion and leads to very high Li CE of up to 99.1% at a current density of 0.2 mA cm-2. Using such an electrolyte, fast charging of Li||NMC333 cells has been realized at a high current density of 3.6 mA cm-2, and stable cycling of Li||NMC622 cells with a high cathode loading of 4 mAh cm-2 has also been demonstrated.
Not provided.
Not Available
Not Available
Improvements in polymer electrolyte fuel cell (PEFC) electrode performance have primarily focused on catalyst and ionomer developments, marginalizing the importance of catalyst ink formulation. In this study, the effect of ink formulation is examined across a series of cathodes comprised of PtCo supported on high surface area carbon (PtCo/ HSC ) and Nafion ionomer using an array of in situ electrochemical and ex situ characterization techniques. In contrast to prior work on Pt/Vu systems, ink water content had little effect on the electrochemically determined ionomer coverage for the PtCo/HSC electrocatalyst examined here. Characterization using nano-scale resolution X-ray computed tomography (nano-CT) demonstrated that water-rich ink formulations lead to a reduction in aggregate size (ionomer + PtCo/HSC), improving local O 2 transport. This understanding, combined with the use of a commercially-available electrocatalyst was used to produced state-of-the-art membrane electrode assemblies with Pt loadings of 0.03/0.08 mg Pt /cm 2 on the anode and cathode respectively, having; i) > 1 A/mg Pt (0.9 V iR-free , 150 kPa, 80 °C, 100% RH, H 2 /O 2 ), ii) 320 mA/cm 2 at 0.8 V, 150 kPa, 80 ° C, 100% RH, H 2 /Air), and iii) > 1 W/cm 2 elec at rated power (0.67 V, 250 kPa, 94 °C, 65% RH, H 2 /Air) or < 0.11 g Pt /kW rated .
With the advent of a new generation of cosmological experiments that will provide high-precision measurements of the cosmic microwave background (CMB) and galaxies in the large-scale structure, it is pertinent to examine the potential of performing a joint analysis of multiple cosmological probes. In this paper, we study the cosmological information content contained in the one-loop power spectra and tree bispectra of galaxies cross-correlated with CMB lensing. We use the FFTLog method to compute angular correlations in spherical harmonic space, applicable for wide angles that can be accessed by forthcoming galaxy surveys. Here, we find that adding the bispectra and cross-correlations with CMB lensing offers a significant improvement in parameter constraints, including those on the total neutrino mass, M ν , and local non-Gaussianity amplitude, ƒ NL . In particular, our results suggest that the combination of the Vera C. Rubin Observatory's Legacy Survey of Space and Time (LSST) and CMB-S4 will be able to achieve σ(M ν )=42 meV from galaxy and CMB lensing correlations, and σ(M ν )=12 meV when further combined with the CMB temperature and polarization data, without any prior on the optical depth.
Steering tokamak plasmas is commonly viewed as a way to avoid disruptions and runaway electrons. Plasma steering sounds as safe as driving to work but will be shown to more closely resemble driving at high speed through a dense fog on an icy road. The long time required to terminate an ITER discharge compared to time over which dangers can be foreseen is analogous to driving in a dense fog. Here, the difficulty of regaining plasma control if it is lost resembles driving on an icy road. Disruptions and runaways are associated with three issues—a solution to one tends to complicate the solution to the other two: loss of plasma position control, excessive heat deposition, and wall melting due to runaway electrons. All three risks must be addressed for ITER to achieve its mission and essentially eliminated before tokamak power plants can be deployed.
We present a novel maximum a posteriori estimator to jointly estimate band powers and the covariance of the three-dimensional power spectrum (P3D) of Ly $\alpha$ forest flux fluctuations, called MAPLE. Our Wiener-filter based algorithm reconstructs a window-deconvolved P3D in the presence of complex survey geometries typical for Ly $\alpha$ surveys that are sparsely sampled transverse to and densely sampled along the line of sight. We demonstrate our method on idealized Gaussian random fields with two selection functions: (i) a sparse sampling of 30 background sources per square degree designed to emulate the current Dark Energy Spectroscopic Instrument; (ii) a dense sampling of 900 background sources per square degree emulating the upcoming Prime Focus Spectrograph Galaxy Evolution Survey. Our proof-of-principle shows promise, especially since the algorithm can be extended to marginalize jointly over nuisance parameters and contaminants, i.e. offsets introduced by continuum fitting. Our code is implemented in JAX and is publicly available on GitHub.
ABSTRACT We present a neural network-based emulator for the galaxy redshift-space power spectrum that enables several orders of magnitude acceleration in the galaxy clustering parameter inference, while preserving 3$\sigma$ accuracy better than 0.5 per cent up to $k_{\mathrm{max}}$ = 0.25 $\, h\text{Mpc}^{-1}$ within Lambda-cold dark matter ($\Lambda$CDM) and around 0.5 per cent $w_0$–$w_a$CDM. Our surrogate model only emulates the galaxy bias-invariant terms of one-loop perturbation theory predictions, these terms are then combined analytically with galaxy bias terms, counter-terms, and stochastic terms in order to obtain the non-linear redshift-space galaxy power spectrum. This allows us to avoid any galaxy bias prescription in the training of the emulator, which makes it more flexible. Moreover, we include the redshift $z \in [0,1.4]$ in the training which further avoids the need for re-training the emulator. We showcase the performance of the emulator in recovering the cosmological parameters of $\Lambda$CDM by analysing the suite of 25 AbacusSummit simulations that mimic the Dark Energy Spectroscopic Instrument luminous red galaxies at $z=0.5$ and 0.8, together as the emission line galaxies at $z=0.8$. We obtain similar performance in all cases, demonstrating the reliability of the emulator for any galaxy sample at any redshift in $0 \lt z \lt 1.4$. We will make our emulator public at github repository.
In power electronics-based power systems (PEPSs), small-signal stability is an important factor for system design and operation, where the impedance-based approach is often used. However, unlike small-scale PEPSs with simple and straightforward impedance models, it would take much more efforts to derive the large-scale PEPSs impedance model, which is very complicated and sometimes may get wrong results due to the elimination of right-half plane (RHP) poles during the impedance aggregation process. To simplify the derivation procedure and analyze the small-signal stability of large-scale PEPSs, this paper proposes a nodal admittance matrix (NAM) based area partition method. In this method, the large-scale PEPS is divided into several sub-areas, and the stability is analyzed within the sub-area first, and then the interconnection stability among these sub-areas is analyzed. The proposed method is scalable and can help to locate the weakest areas/converters that may cause instability in the whole system. In this paper, the concept of the proposed method and its application to an example system are introduced. Experimental results are also given to validate the effectiveness of the proposed method.
The nodal admittance matrix (NAM)-based approach is suitable for analyzing the small-signal stability of large-scale power electronics-based power systems (PEPSs) as it preserves the system structure by utilizing the admittance matrix. Previously, NAM-based area partition has been proposed, which divides the system into various subareas and interconnections for easier analysis of the low-dimension matrix compared to the entire system-based high-dimension matrix. However, no partition algorithm has been presented for the NAM-based area partition method. This paper focuses on implementing the spectral partitioning algorithm for partitioning large-scale PEPSs into a low-dimension matrix to reduce the computation complexity of the analysis. These spectral components facilitate data transformation into a new space, enabling the application of traditional clustering methods like k-means. To evaluate the performance of the partitioning method, the subareas and interconnections obtained from the spectral clustering algorithm are incorporated into the NAM-based area partition method for a large system with 140 buses. The computational times of the original method, where the NAM-based criterion is directly applied to the entire system, are compared with those of the NAM-based partition method in MATLAB. PSCAD simulations of the whole system and the obtained subareas are conducted to validate the effectiveness of the proposed algorithm.
Environmental and regulatory constraints are increasingly posing challenges to the optimal operation of hydroelectric facilities. Hydrogen energy storage (HES) is well-suited to address these challenges.Using excess or low-cost hydroelectric power during off-peak hours to produce hydrogen can help reduce water spills and unlock opportunities for energy arbitrage. Moreover, the oxygen byproduct of electrolysis can be used to improve the dissolved oxygen (DO) levels in tailrace water. %, a key water quality metric for hydroelectric facilities.This paper presents an innovative framework for modeling and assessing the integrated hydroelectric-hydrogen system, considering subsystem constraints and coupling, benefits in spill water reduction and DO mitigation, as well as diverse hydrogen utilization, including re-electrification, blending with natural gas, and direct sales. Comprehensive case studies were conducted to assess the techno-economic performance of the integrated system in different deployment scenarios.
In wireless power transfer (WPT) systems, output power (Pout) can be controlled through input parameters such as, input voltage (Vin) , duty cycle (d) , and switching frequency (fsw) . The impact of these control parameters on the overall system efficiency has not been explored in previous studies. This paper focuses on the efficiency (η) and Pout sensitivity to these control parameter variations in an LCC-Series tuned WPT system. There are multiple combinations of Vin, d , and fsw that can achieve a specified target Pout . However, it is important to determine the optimal combination of these control variables that will yield the maximum η for a target Pout . A MATLAB/Simulink model is built to calculate and measure η and Pout . In order to achieve this result, several simulations are run where Vin,d , and fsw are swept across a wide range to cover all possible combinations. MATLAB's Sensitivity Analysis toolbox is used to evaluate how the parameters influence the model's output. Finally, an experimental prototype is implemented. The optimal values acquired using the sensitivity analysis is then plugged into the hardware prototype and compared with the simulation. The results obtained confirm the validity of the proposed method.
The nodal admittance matrix (NAM)-based approach is well-suited for small-signal stability analysis of large-scale power electronics-based power systems (PEPSs), as it preserves the system structure through its admittance matrix. Previous studies have explored partitioning such systems into subareas and interconnections to reduce computational burden; however, they lacked a formal algorithmic procedure for determining feasible partitions. While several grid partitioning methods, such as those based on graph theory or machine learning, exist in the literature, they cannot be directly applied to NAM-based analysis due to differing objectives and constraints. Here, this paper addresses this gap by presenting a systematic, step-by-step procedure for applying a spectral partitioning algorithm that yields a division of the system into subareas suitable for NAM-based analysis. The computational complexity of the proposed method is also derived to demonstrate its efficiency and justify the practicality of the resulting subarea decomposition. The performance of the partitioning method is evaluated by applying the spectral clustering-derived subareas and interconnections to the NAM-based partitioning approach on a 140-bus system. Computational times for the full-system and partitioned NAM analyses are compared using MATLAB. Additionally, PSCAD simulations of the complete system and partitioned subareas are carried out to verify the effectiveness of the proposed method.
Abstract With the planned future reliance on variable renewable energy, the ability to store energy for prolonged time periods will be required to reduce the disruption of market fluctuations. This paper presents a method to analyze a hybrid liquid-oxygen (LOx) storage/direct-fired supercritical carbon dioxide (sCO2) power cycle and optimize the economic performance over a diverse range of scenarios. The system utilizes a modified version of the NET Power process to produce energy when energy demand exceeds the supply while displacing much of the cost of the air separation unit (ASU) energy requirements through cryogenic storage of oxygen. The model uses marginal cost of energy data to determine the optimal times to charge and discharge the system over a given scenario. The model then applies ramp rates and other time-dependent factors to generate an economic model for the system without storage considerations. The size of the storage system is then applied to create a realistic model of the plant operation. From the real plant operation model, the amount of energy charged and discharged, the capital expenditures (CAPEX) of each system, energy costs and revenue and other parameters can be calculated. The economic parameters are then combined to calculate the net present value (NPV) of the system for the given scenario. The model was then run through the SMPSO genetic algorithm in Python for a variety of geographic regions and large-scale scenarios (high solar penetration) to maximize the NPV based on multiple parameters for each subsystem. The LOx storage requirements will also be discussed.
Replacing the existing aging analog instrumentation and control (I&C) systems with modern safety control and protection digital technology offers one of the foremost means of performance improvements and cost reductions for the existing nuclear power plants (NPPs). However, the qualification of digital I&C systems remains a challenge, especially considering the issue of software common-cause failures (CCFs), which are difficult to address. With the application and upgrades of advanced digital I&C systems, software CCFs have become a potential threat to plant safety because most redundant designs use similar digital platforms or software in the operating and application systems. With complex designs of multilayer redundancy to meet the single-failure criterion, digital I&C safety systems (e.g., engineered safety-features actuation system [ESFAS]) are of a particular concern in the U.S. Nuclear Regulatory Commission (NRC) licensing procedures. This paper applies a modularized approach to conduct redundancy-guided systems-theoretic hazard analysis for an advanced digital ESFAS with multilevel redundancy designs. Systematic methods and risk-informed tools are incorporated to address both hardware and software CCFs, which provide guidance to eliminate the triggers of potential single points of failure in the design of digital safety systems in advanced plant designs.