Search NASA⌕ Search

SEARCH · Search NASA

Results for “process monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Real-time monitoring of calcification process by Sporosarcina pasteurii biofilm

Sporosarcina pasteurii is known to produce calcite or biocement in the presence of urea and Ca 2+ . Herein, we report the use of novel ultramicrosensors such as pH, Ca 2+ , and redox sensors, along with a scanning electrochemical microscope (SECM), to monitor a real-time, bacteria-mediated urea hydrolysis process and subsequent changes in morphology due to CaCO 3 precipitation. We report that the surface pH of a live biofilm changed rapidly from 7.4 to 9.2 within 2 min, whereas similar fast depletion (10 min) of Ca 2+ was observed from 85 mM to 10 mM in the presence of a high urea (10 g L -1 ) brine solution at 23 °C. Both the pH and the Ca 2+ concentration profiles were extended up to 600 μm from the biofilm surface, whereas the bulk chemical composition of the brine solution remained constant over the entire 4 h of SECM experiments. In addition, we observed a change in biofilm surface morphology and an increase in overall biofilm height of 50 μm after 4 h of precipitation. Electron microscopy confirmed the changes in surface morphology and formation of CaCO 3 crystals. Development of the Ca 2+ profile took 10 min, whereas that of the pH profile took 2 min. This finding indicates that the initial urea hydrolysis process is fast and limited by urease or number of bacteria, whereas later CaCO 3 formation and growth of crystals is a slow chemical process. The ultramicrosensors and approaches employed here are capable of accurately characterizing bioremediation on temporal and spatial scales pertinent to the microbial communities and the processes they mediate.

59 BASIC BIOLOGICAL SCIENCES↗

Determination of nanoparticle collision cross section distribution functions in low pressure plasma synthesis reactors via ion mobility spectrometry

Low pressure (< 20 Torr) non-thermal plasma flow tube reactors are often used for the synthesis of high purity nanoparticles (NPs) via nucleation and subsequent growth from vapor phase precursors. In spite of their utility, process monitoring (i.e. output NP size characterization) in such reactors is difficult, as there is a dearth of techniques available for online nanoparticle size distribution function measurement. In this study, we developed and applied an ion mobility spectrometry (IMS) system consisting of a low pressure differential mobility analyzer (LPDMA) and electrical detector to determine the collision cross section distribution functions of Si NPs synthesized in a radiofrequency non-thermal SiH4-Ar plasma operated at ~2 Torr (266 Pa). The collision cross section, roughly proportional to projected area, is a parameter quantifying the size and structure of nanometer scale species in the vapor phase. We introduce the collision cross section distribution function as a metric for potential use in online process monitoring in NP synthesis. Proper inversion of the collision cross section distribution function requires a priori knowledge of the LPDMA transfer function. We utilized a tandem differential mobility analyzer approach, coupled with a Twomey-Markwoski based scheme to determine LPDMA transfer functions. Subsequent application of these transfer functions in collision cross section distribution function determination showed that at the outlet of the non-thermal plasma flow tube reactor, both negatively and positively charged Si NPs persisted with nearly identical collision cross section distribution functions. NPs were found to have mode “mobility equivalent” diameters near 10 nm, and via TEM analysis were found to persist at the reactor outlet as small aggregates composed of ~5 nm diameter primary particles. Size distributions functions inferred from collision cross section measurements were compared to size distribution functions inferred from TEM images; excellent agreement was found between IMS and TEM for both mean mobility equivalent diameter and distribution function width. In total, this study shows that (1) IMS is a viable approach for process monitoring in non-thermal plasma NP flow tube synthesis systems, (2) although NPs are modestly aggregated at low-pressure plasma reactor outlets, the extent of aggregation is considerably less than observed in most atmospheric pressure and equilibrium NP synthesis systems (e.g. flames), and (3) after exiting the plasma reactor, the decharging of NPs from highly negatively charge states to a bipolar charge distribution likely drives aggregation on the plasma boundary.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Review of on-line and near real-time spectroscopic monitoring of processes relevant to nuclear material management

Spectroscopic chemometric based on-line monitoring of used nuclear fuel (UNF) reprocessing solutions and characterization of legacy nuclear waste (LNW) stored at Hanford is discussed in this manuscript. Using on-line and near real-time monitoring with spectroscopy, as opposed to traditional off-line monitoring, can significantly reduce the cost, risk and improve the efficiency of characterizing UNF reprocessing streams and LNW since the data can be collected non-destructively and analyzed nearly instantly. It can accurately quantify and qualify nuclear material in near-real time which can help to know the immediate UNF reprocessing stream and LNW conditions and detect the diversion of materials. The ability to be applied in a real reprocessing plant and in an actual Hanford waste tank/transfer pipe has been demonstrated by applying this technique to accurately quantify analytes in real UNF streams and LNW samples. Furthermore, the future development of spectroscopy based on-line monitoring is also discussed in this manuscript.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Advanced Safeguards Technology Demonstration at Pacific Northwest National Laboratory

The International Atomic Energy Agency (IAEA) has established international safeguards standards for fissionable material at spent fuel reprocessing plants to ensure that significant quantities of weapons-grade nuclear material are not diverted over a specified time frame. Currently, methods to verify that the facilities are operating under adequate safeguard-declared conditions require time consuming sampling and expensive, destructive analysis. The time delay between sampling and subsequent analysis provides a potential opportunity to divert the material out of the appropriate chemical stream. One way to avoid this problem is to use process monitoring equipment that is capable of on-line and in near-real time monitoring of the flowsheet radiochemical streams to rapidly identify deviations from normal operating conditions. Three integrated systems for flowsheet monitoring are currently being developed at PNNL including: 1) Multi-Isotope Process Monitor (MIP), 2) a spectroscopy-based monitor utilizing UV-Vis-NIR (Ultra Violet-Visible-Near Infrared) and Raman spectrometers, and 3) Electrochemically Modulated Separations (EMS). MIP uses gamma spectroscopy and pattern recognition software to identify off-normal conditions in process streams. The UV-Vis-NIR and Raman spectroscopic monitoring continuously measures chemical compositions of the process streams including actinide metal ions (U, Pu, Np), selected fission products, and major cold flowsheet chemicals. EMS provides an on-line means for pre-separating and preconcentrating elements of interest out of complex matrices prior to detection via non-destructive assay by gamma spectroscopy or destructive analysis with mass spectrometry. PNNL previously reported some of its initial modeling work as proof of principle. Here we will provide a general overview of the technologies and the ongoing demonstrations that utilize actual spent fuel.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

In situ Synchrotron X‐ray Metrology Boosted by Automated Data Analysis for Real‐time Monitoring of Cathode Calcination

Abstract Synchrotron X‐ray‐based in situ metrology is advantageous for monitoring the synthesis of battery materials, offering high throughput, high spatial and temporal resolution, and chemical sensitivity. However, the rapid generation of massive data poses a challenge to on‐site, on‐the‐fly analysis needed for real‐time process monitoring. Here, a weighted lagged cross‐correlation (WLCC) similarity approach is presented for automated data analysis, which merges with in situ synchrotron X‐ray diffraction metrology to monitor the calcination process of the archetypal nickel‐based cathode, LiNiO 2 . The WLCC approach, incorporating variables that account for peak shifts and width changes associated with structural transformations, enables rapid extraction of phase progression within 10 seconds from tens of diffraction patterns. Details are captured, from initial precursors to intermediates and the final layered LiNiO 2 , providing information for agile on‐site adjustments during experiments and complementing post hoc diffraction analysis by offering insights into early‐stage phase nucleation and growth. Expanding this data‐powered platform paves the way for real time calcination process monitoring and control, which is pivotal to quality control in battery cathode manufacturing.

36 MATERIALS SCIENCE↗

In-line measurements of below-the-surface food deformation during drying with an interference-based optical fiber strain sensor

Real-time measurements of food deformation are important for quality control in drying, yet they pose significant challenges. In this study, we developed an interference-based optical fiber strain sensor to enable in-line, continuous, below-the-surface strain measurements in drying of soft food samples. Compared to a strain resolution of 8 × 10 -4 at zero strain and 7.2 × 10 -3 at 0.20 strain reported in our previously published work, the present study achieves markedly improved resolutions of 1.3 × 10 -4 at zero strain and 7.8 × 10 -4 at 0.25 strain, which strains are the lower and higher boundaries of the dynamic range, respectively. This nearly order-of-magnitude improvement is attributed to the unique interference-based sensing mechanism, no need for calibration to convert optical signals to strain, and the system-design-enabled immunity to fiber-disk misalignments and light source intensity fluctuations. To demonstrate the in-line process monitoring, deformation measurements of fresh banana slices and sugar cookie doughs were carried out in a benchtop oven and an industrial-scale hot-air pilot dryer, respectively. In both dryers, strain measurements were continuously measured during the whole drying process at various depths and radii below the sample surfaces, with the strains up to 25%. Computer vision was used only in the benchtop drying to confirm the faithfulness of the fiber sensor measurements and cannot provide below-the-surface measurements. The measured spatiotemporal deformation allowed us to confirm the shell-hardening effect and to determine the speed and location of large deformation changes in the whole drying process, the latter of which is related to the sample cracking. To the best of the authors’ knowledge, this study is the first to report on an interferometry-based fiber sensor to measure food deformation. This sensor and the sensing mechanism have high potential for real-time process monitoring and control to prevent over-drying or cracking during drying processes.

47 OTHER INSTRUMENTATION↗

Design and Operation of a Multi-Bed Catalytic Micro-Reactor for the Study of Co-Processing of Bio-Oils with VGO

An industry wide shift from fossil-based fuel to renewable fuel sources including biomass, municipal waste, and plastics will require new process monitoring methods to minimize transitional risks including off specification product formation and catalyst deactivation. This project aims to provide a machine learning based process monitoring tool composed of online, slipstream mass spectra for use in biomass refineries and co-processing in existing refineries allowing operators to monitor product qualities and adjust process conditions accordingly. In order to maximize the robustness of the tool, large volumes of data must be collected to fine tune model parameters which consists of both micro and pilot scale mass spectral data. Micro-scale data is collected with a multi-tube micro-reactor housing up to six catalysts in horizontal beds, coupled with a molecular beam mass spectrometer. A pyrolizer equipped with an auto-sampler streamlines the micro-scale data collection process. This type of pyrolizer/micro-reactor configuration does not exist on the market, and therefore had to be created for the purposes of this project. The design and commissioning of this reactor will be presented in detail. This reactor set-up is highly flexible and increases throughput of analysis. For catalyst testing, each bed can be individually selected simply by turning valves. For catalyst reduction and regeneration, simultaneous flow through all six beds is used. The reproducibility of the system was first assessed with whole biomass pyrolysis along with pyrolysis of calibration standards. Initial work on this system evaluated two FCC catalysts, equilibrium catalyst (E-cat), and a proprietary catalyst from Johnson Matthey specifically design for co-processing of bio-oil with vacuum gas oil (VGO). This work used model compounds and VGO which illuminated differences in products produced by the catalysts.

biomass↗

Dynamic dielectric analysis for nondestructive cure monitoring and process control

Dynamic dielectric analysis (DDA) is an effective in situ NDE method that can monitor the reaction status in thermosets and the phase changes in thermoplastics, including slow reactions occuring late in the cure cycle and recrystallization during annealing. The effects of moisture and resin history on reaction rate can also be determined, as can ionic and dipolar contributions. The ionic mobility parameter is noted to be an excellent monitor of viscosity above the glass transition temperature. The ability of DDA to monitor cure rate variations in a thick section during autoclaving has been demonstrated.

Kranbuehl, D. E.↗

A Method for Monitoring Deposition at a Solid Cathode in an Electrorefiner for a Two-Species System Using Electrode Potentials

Currently, process monitoring of spent nuclear fuel electrorefining relies upon sampling and destructive analysis methods coupled with extrapolative thermodynamic process models for non-interrupted operations. Corrections to those models are performed infrequently, jeopardizing both the control of the process and safeguarding of nuclear material. Furthermore, the timeliness of obtaining the results is inadequate for application of international safeguards protocol. Alternatively, a system that dynamically utilizes electrical data such as electrode potentials and cell current can hypothetically be used to achieve real-time process monitoring and more robust control as well as improved safeguards. Efforts to develop an advanced model of the electrorefiner to date have focused on a forward modeling approach by using feed and salt compositions to determine the product composition, cell current and electrode potential response. Alternatively, an inverse model was developed, and reported here, to predict the product deposition rates on a cathode using the cell current, cathode potential, and fundamental relations of electrochemistry. The model was applied to the following cases: pure uranium deposition, co-deposition of uranium and plutonium, and co-deposition of uranium and zirconium. The deposition rates predicted by the inverse model were compared to those of a forward model, ERAD.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

DATA RECOVERY EFFORTS AT IDAHO NATIONAL LABORATORY, OAK RIDGE NATIONAL LABORATORY, AND SAVANNAH RIVER NATIONAL LABORATORY

Abstract was already submitted. Could not find the previous number. Would be fine with attaching/update of old number. Abstract Below: Modern nuclear facilities will have significant process monitoring capability for their operators. These systems will also be used for domestic safeguards applications, which has led to research over new diversion-detection algorithms. Curiously missing from these efforts are verification and validation data sets. A tri-laboratory project to locate the existing data sets and recover their data has yielded three major potential sources of data. The first is recovery of the process monitoring data of the Idaho Chemical Processing Plant, which now has a distributable package for algorithm developers. The second data set is extensive sampling and process data from Savannah River National Laboratory’s F- and H-canyon sites. Finally, high fidelity data from the start-up tests at the Barnwell Reprocessing Facility is in recovery. This paper details the data sets and compares their relative attributes.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Distributed optical fiber sensing: Review and perspective

Over the past few decades, optical fibers have been widely deployed to implement various applications in high-speed long-distance telecommunication, optical imaging, ultrafast lasers, and optical sensors. Distributed optical fiber sensors characterized by spatially resolved measurements along a single continuous strand of optical fiber have undergone significant improvements in underlying technologies and application scenarios, representing the highest state of the art in optical sensing. This work is focused on a review of three types of distributed optical fiber sensors which are based on Rayleigh, Brillouin, and Raman scattering, and use various demodulation schemes, including optical time-domain reflectometry, optical frequency-domain reflectometry, and related schemes. Recent developments of various distributed optical fiber sensors to provide simultaneous measurements of multiple parameters are analyzed based on their sensing performance, revealing an inherent trade-off between performance parameters such as sensing range, spatial resolution, and sensing resolution. This review highlights the latest progress in distributed optical fiber sensors with an emphasis on energy applications such as energy infrastructure monitoring, power generation system monitoring, oil and gas pipeline monitoring, and geothermal process monitoring. This review aims to clarify challenges and limitations of distributed optical fiber sensors with the goal of providing a pathway to push the limits in distributed optical fiber sensing for practical applications.

Lu, Ping (ORCID:0000000292010956)↗

Remote Americium Detection Using an Optical Sensor: A D-Optimal Strategy for Efficient PLS-Based Modeling

A fiber-optic visible–near-infrared absorption spectroscopy system in a glove box was demonstrated for remote quantification of Am(III) (0–500 µM) and HNO 3 (0.1–9 M) using partial least squares regression (PLSR) models. The sensor platform, featuring a simple plug-and-play spectrophotometer, can enable noninvasive, real-time monitoring of actinide process solutions. To establish a flexible PLSR model calibration strategy, a D-optimal design developed using Nd(III) in previous studies was successfully extended to an actinide system with Am(III) to effectively minimize sample set size while maintaining robust prediction performance. The results suggest strong spectral similarities between Nd(III) and Am(III) and validate Nd(III) as an effective optical surrogate for trivalent actinide species. This work also supports the generalizability of a D-optimal training set selection approach for two-factor systems. The PLS1 models for Am(III) and HNO 3 outperformed a PLS2 model and maintained reasonable performance in the presence of interfering U(VI). The resulting sensor system and multivariate approach provides a flexible and scalable solution for process monitoring, control, and safety in diverse nuclear applications.

actinide↗

Grounding explanations in evolving, diagnostic situations

Certain fields of practice involve the management and control of complex dynamic systems. These include flight deck operations in commercial aviation, control of space systems, anesthetic management during surgery or chemical or nuclear process control. Fault diagnosis of these dynamic systems generally must occur with the monitored process on-line and in conjunction with maintaining system integrity.This research seeks to understand in more detail what it means for an intelligent system to function cooperatively, or as a 'team player' in complex, dynamic environments. The approach taken was to study human practitioners engaged in the management of a complex, dynamic process: anesthesiologists during neurosurgical operations. The investigation focused on understanding how team members cooperate in management and fault diagnosis and comparing this interaction to the situation with an Artificial Intelligence(AI) system that provides diagnoses and explanations. Of particular concern was to study the ways in which practitioners support one another in keeping aware of relevant information concerning the state of the monitored process and of the problem solving process.

Johannesen, Leila J.↗

Calibrating IR Cameras for In-Situ Temperature Measurement During the Electron Beam Melting Process using Inconel 718 and Ti-Al6-V4

The Department of Energy s (DOE) Manufacturing Demonstration Facility (MDF) at Oak Ridge National Laboratory (ORNL) provides world-leading capabilities in advanced manufacturing (AM) facilities which leverage previous, on-going government investments in materials science research and characterization. MDF contains systems for fabricating components with complex geometries using AM techniques (i.e. 3D-Printing). Various metal alloy printers, for example, use electron beam melting (EBM) systems for creating these components which are otherwise extremely difficult- if not impossible- to machine. ORNL has partnered with manufacturers on improving the final part quality of components and developing new materials for further advancing these devices. One method being used to study (AM) processes in more depth relies on the advanced imaging capabilities at ORNL. High performance mid-wave infrared (IR) cameras are used for in-situ process monitoring and temperature measurements. However, standard factory calibrations are insufficient due to very low transmissions of the leaded glass window required for X-ray absorption. Two techniques for temperature calibrations will be presented and compared. In-situ measurement of emittance will also be discussed. Ample information can be learned from in-situ IR process monitoring of the EBM process. Ultimately, these imaging systems have the potential for routine use for online quality assurance and feedback control.

Electron-Beam Melting↗

A screening platform to monitor RNA processing and protein-RNA interactions in ribonuclease P uncovers a small molecule inhibitor

Ribonucleoprotein (RNP) complexes and RNA-processing enzymes are attractive targets for antibiotic development owing to their central roles in microbial physiology. For many of these complexes, comprehensive strategies to identify inhibitors are either lacking or suffer from substantial technical limitations. Here, we describe an activity-binding-structure platform for bacterial ribonuclease P (RNase P), an essential RNP ribozyme involved in 5' tRNA processing. A novel, real-time fluorescence-based assay was used to monitor RNase P activity and rapidly identify inhibitors using a mini-helix and a pre-tRNA-like bipartite substrate. Using the mini-helix substrate, we screened a library comprising 2560 compounds. Initial hits were then validated using pre-tRNA and the pre-tRNA-like substrate, which ultimately verified four compounds as inhibitors. Biolayer interferometry-based binding assays and molecular dynamics simulations were then used to characterize the interactions between each validated inhibitor and the P protein, P RNA and pre-tRNA. X-ray crystallographic studies subsequently elucidated the structure of the P protein bound to the most promising hit, purpurin, and revealed how this inhibitor adversely affects tRNA 5' leader binding. This integrated platform affords improved structure-function studies of RNA processing enzymes and facilitates the discovery of novel regulators or inhibitors.

59 BASIC BIOLOGICAL SCIENCES↗

Multivariate Analysis for Quantification of Plutonium(IV) in Nitric Acid Based on Absorption Spectra

Development of more effective, reliable, and fast methods for monitoring process streams is a growing opportunity for analytical applications. Many fields can benefit from on-line monitoring, including the nuclear fuel cycle where improved methods for monitoring radioactive materials will facilitate maintenance of proper safeguards and ensure safe and efficient processing of materials. On-line process monitoring with a focus on optical spectroscopy can provide a fast, non-destructive method for monitoring chemical species. However, identification and quantification of species can be hindered by the complexity of the solutions if bands overlap or show condition-dependent spectral features. Plutonium (IV) is one example of a species which displays significant spectral variation with changing nitric acid concentration. Single variate analysis (i.e. Beer’s Law) is difficult to apply to the quantification of Pu(IV) unless the nitric acid concentration is known and separate calibration curves have been made for all possible acid strengths. Multivariate, or chemometric, analysis is an approach that allows for the accurate quantification of Pu(IV) without a priori knowledge of nitric acid concentration.

Lines, Amanda M.↗

Time-lapse VSP data processing for monitoring CO2 injection

As a part of the effort of the Southwest Regional Partnership on Carbon Sequestration supported by U.S. Department of Energy and managed by the National Energy Technology Laboratory, two sets of time-lapse VSPs were acquired and processed in oil fields undergoing CO{sub 2} injection. One set of VSPs was acquired at the Aneth oil field in Utah, the other set at the Scurry Area Canyon Reef Operators Committee (SACROC) field in West Texas. One baseline and two repeat VSP surveys were conducted from 2007 to 2009 at the Aneth oil field in Utah for monitoring CO{sub 2} injection. The aim of the time-lapse VSP surveys is to study the combined enhanced oil recovery (EOR) and CO{sub 2} sequestration in collaboration with Resolute Natural Resources, Inc. VSP data were acquired using a cemented geophone string with 60 levels at depth from 805 m to 1704 m, and CO{sub 2} is injected into a horizontal well nearby within the reservoir at depth approximately from 1730 m to 1780 m. For each VSP survey, the data were acquired for one zero-offset source location and seven offset source locations (Figure 1). The baseline VSP survey was conducted before the CO{sub 2} injection. More than ten thousand tons of CO{sub 2} was injected between each of the two repeat VSP surveys. There are three horizontal injection wells, all originating from the same vertical well. One is drilled towards Southeast, directly towards the monitoring well (Figure 2), and the other two towards Northwest, directly away from the monitoring well. The injection is into the top portion of the Desert Creek formation, just beneath the Gothic shale, which acts as the reservoir seal. The initial baseline acquisition was done in October 2007; subsequent time-lapse acquisitions were conducted in July 2008, and January 2009. The acquisition geometry is shown in Figure 1. Shot point 1 is the zero-offset source location, Shot points 2 to 8 are the seven offset VSPs, arranged in a quarter circle on the Northwest side of the monitoring well. The horizontal injection well is shown in green. The black lines in Figure 1 show the approximate reflection coverage al reservoir depth from the respective offset source locations. VSP source location 5 is in a direct line with the injection. The 60 geophone sondes were cemented into the monitor well just before the baseline VSP acquisition and consisted of 96 geophone channels, with 18 three-component geophones (at the bottom of the string) and 42 single vertical component phones above. For this study, only the vertical geophone data were used.

54 ENVIRONMENTAL SCIENCES↗

Coupling a Transient Solvent Extraction Module with the Separations and Safeguards Performance Model

A past difficulty in safeguards design for reprocessing plants is that no code existed for analysis and evaluation of the design. A number of codes have been developed in the past, but many are dated, and no single code is able to cover all aspects of materials accountancy, process monitoring, and diversion scenario analysis. The purpose of this work was to integrate a transient solvent extraction simulation module developed at Oak Ridge National Laboratory, with the SSPM Separations and Safeguards Performance Model, developed at Sandia National Laboratory, as a first step toward creating a more versatile design and evaluation tool. The SSPM was designed for materials accountancy and process monitoring analyses, but previous versions of the code have included limited detail on the chemical processes, including chemical separations. The transient solvent extraction model is based on the ORNL SEPHIS code approach to consider solute build up in a bank of contactors in the PUREX process. Combined, these capabilities yield a much more robust transient separations and safeguards model for evaluating safeguards system design. This coupling and the initial results are presented. In addition, some observations toward further enhancement of separations and safeguards modeling based on this effort are provided, including: items to be addressed in integrating legacy codes, additional improvements needed for a fully functional solvent extraction module, and recommendations for future integration of other chemical process modules.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗