Search NASA⌕ Search

SEARCH · Search NASA

Results for “quantum noise”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Low Frequency 1/f Noise on QWIPs, nBn, and Superlattice Focal Plane Array

Noise Equivalent Difference Temperature (NE△T) is a standard performance metric for most infrared focal plane array (FPA) systems. The frequency bandwidth and range associated with NE△T is at high frequency and it does not describe the long time noise behavior or the very low frequency noise of the FPA. Very low frequency noise measurement requires data capture that takes longer time duration and sampling interval. This study investigates low frequency noise in QWIP, nBn and LWIR n-type Complementary Barrier Infrared Detector (CBIRD) FPAs. The corner frequencies are extracted from the power spectral density (PSD) as function of frequency. The peak wavelength, quantum efficiency of QWIP detector are 6.2 µm and 2 %, respectively. QWIP FPA has a mean NE△T ~ 25 mK at an operating temperature of 65 K and an integration time of 16 msec. The mean QWIP PSD plot shows a corner frequency of < 0.5 mHz. The nBn FPA with 4 µm cut off and quantum efficiency of 67 % has NE△T ~ 15.6 mK at an integration time ~ 7.52 msec and an operating temperature of 120 K. The nBn has corner frequency of > 50 mHz. Lastly the n-type CBIRD FPA with a 50% cutoff at 8.8 µm and quantum efficiency of ~ 50 % has an NE△T ~ 18.6 mK at an integration time of 1.86 msec and operating temperature 120 K. The superlattice FPA has a corner frequency ~ 10 mHz. The investigation of the tail on the NE△T histogram reveals that its origin is not accounted for entirely by the high noise current, but also it needs the inclusion of lower responsivity for some pixels.

Pepper, B.↗

InGaAsSb/AlGaAsSb Heterojunction Phototransistors for Infrared Applications

High quality infrared (IR) quantum detectors are important for several applications, such as atmospheric remote sensing, chemical detection and absorption spectroscopy. Although several IR detectors are commercially available, with different materials and structures, they provide limited performance regarding the signal-to-noise ratio and the corresponding minimum detectable signal. InGaAsSb/AlGaAsSb heterojunction based phototransistors show strong potential for developing IR sensors with improved performance. In this paper, the performance of a novel npn InGaAsSb/AlGaAsSb heterojunction phototransistor is presented. This performance study is based on experimental characterization of the device dark current, noise and spectral response. Detectivity of 1.7x10(exp 9) cmHz(exp 1/2)/W at 2 microns was obtained at 100 C temperature and 2 V bias voltage. This corresponds to a responsivity of 94.7 A/W and an internal gain of 156 with about 37.7% quantum efficiency. Reducing the temperature to -30 C allows to increase the bias to 3V and enhance the detectivity to 8.7x10(exp 10) cmHz(exp 1/2)/W at the same wavelength, which corresponds to a responsivity of 386.5 A/W and an internal gain of 288.2 with about 83.3% quantum efficiency. The device impulse response and linearity, including the corresponding dynamic range, also are presented. Impulse response analysis indicated a settling time of about 1.1 s at 2V and 100 C, while linearity measurements indicated a constant responsivity in the radiation intensity range of 1.6x10(exp -7) W/sq cm and 31.6 mW/sq cm.

Refaat, Tamer F.↗

Characterizing Rocky and Gaseous Exoplanets with 2 m Class Space-based Coronagraphs

Several concepts now exist for small, space-based missions to directly characterize exoplanets in reflected light. While studies have been performed that investigate the potential detection yields of such missions, little work has been done to understand how instrumental and astrophysical parameters will affect the ability of these missions to obtain spectra that are useful for characterizing their planetary targets. Here, we develop an instrument noise model suitable for studying the spectral characterization potential of a coronagraph-equipped, space-based telescope. We adopt a baseline set of telescope and instrument parameters appropriate for near-future planned missions like WFIRST-AFTA, including a 2 m diameter primary aperture, an operational wavelength range of 0.4–1.0 μm, and an instrument spectral resolution of λ/Δλ =70, and apply our baseline model to a variety of spectral models of different planet types, including Earth twins, Jupiter twins, and warm and cool Jupiters and Neptunes. With our exoplanet spectral models, we explore wavelength-dependent planet–star flux ratios for main-sequence stars of various effective temperatures and discuss how coronagraph inner and outer working angle constraints will influence the potential to study different types of planets. For planets most favorable to spectroscopic characterization—cool Jupiters and Neptunes as well as nearby super-Earths—we study the integration times required to achieve moderate signal-to-noise ratio spectra. We also explore the sensitivity of the integration times required to either detect the bottom or presence of key absorption bands (for methane, water vapor, and molecular oxygen) to coronagraph raw contrast performance, exozodiacal light levels, and the distance to the planetary system. Decreasing detector quantum efficiency at longer visible wavelengths makes the detection of water vapor in the atmospheres of Earth-like planets extremely challenging, and also hinders detections of the 0.89 μm methane band. Additionally, most modeled observations have noise dominated by dark currents, indicating that improving CCD performance could substantially drive down requisite integration times. Finally, we briefly discuss the extension of our models to a more distant future Large UV-Optical-InfraRed (LUVOIR) mission.

Astrobiology↗

Performance of Small Pore Microchannel Plates

Small pore size microchannel plates (MCP's) are needed to satisfy the requirements for future high resolution small and large format detectors for astronomy. MCP's with pore sizes in the range 5 micron to 8 micron are now being manufactured, but they are of limited availability and are of small size. We have obtained sets of Galileo 8 micron and 6.5 micron MCP's, and Philips 6 micron and 7 micron pore MCP's, and compared them to our larger pore MCP Z stacks. We have tested back to back MCP stacks of four of these MCP's and achieved gains greater than 2 x 1O(exp 7) with pulse height distributions of less than 40% FWHM, and background rates of less than 0.3 events sec(exp -1) cm(exp -2). Local counting rates up to approx. 100 events/pore/sec have been attained with little drop of the MCP gain. The bare MCP quantum efficiencies are somewhat lower than those expected, however. Flat field images are characterized by an absence of MCP fixed pattern noise.

Siegmund, O. H. W.↗

Kinetic Inductance Photodetectors Based on Nonequilibrium Response in Superconducting Thin-Film Structures

While experimental studies of kinetic-inductance sensors have been limited so far by the temperature range near the superconducting transition, these detectors can be very sensitivity at temperatures well below the transition, where the number of equilibrium quasiparticles is exponentially small. In this regime, a shift of the quasiparticle chemical potential under radiation results in the change of the kinetic inductance, which can be measured by a sensitive SQUID readout. We modeled the kinetic inductance response of detectors made from disordered superconducting Nb, NbC, and MoRe films. Low phonon transparency of the interface between the superconductor and the substrate causes substantial re-trapping of phonons providing high quantum efficiency and the operating time of approximately 1 ms at 1 K. Due to the small number of quasiparticles, the noise equivalent power of the detector determined by the quasiparticle generation-recombination noise can be as small as approximately 10(exp -19) W/Hz(exp 1/2) at He4 temperatures.

Sergeev, A. V.↗

A study pertaining to a very low temperature hydrogen maser feasibility

Very low temperature atomic hydrogen masers were developed. The advantages over room temperature hydrogen masers include higher radiated power due to the higher beam intensities possible using low temperature techniques and the much smaller electron spin flip cross section at low temperatures, lower cavity and amplifier noise temperatures, increased stability against mechanical creep at low temperatures, and opportunities to extend H atom collision studies to low temperatures, where quantum effects and details of the interatomic potentials are much more important.

Crampton, S. B.↗

Advanced CCD imager technology for use from 1 to 10,000 A

A low-noise, high-sensitivity charge-coupled-device (CCD) technology for imaging applications extending from the soft X-ray (1 A) to the near-infrared (10,000 A) regimes was developed together with a fabrication technology for making back-illuminated versions of these devices with quantum efficiencies as high as 90 percent from 5000 to 7000 A. The efforts have focused on two devices, a 64 x 64 pixel back-illuminated imager with two output ports that operates at 2000 frames per second with 23 electrons read noise, and a larger device, with 420 x 420 pixel format, designed for lower frame rates with noise as low as 1.5 electrons and used at visible, UV, and X-ray wavelengths. Applications to plasma diagnostics include Thomson scattering and high-frame-rate imaging in the visible, as well as X-ray imaging and bolometry.

Twichell, J. C.↗

VUV Testing of Science Cameras at MSFC: QE Measurement of the CLASP Flight Cameras

The NASA Marshall Space Flight Center (MSFC) has developed a science camera suitable for sub-orbital missions for observations in the UV, EUV and soft X-ray. Six cameras were built and tested for the Chromospheric Lyman-Alpha Spectro-Polarimeter (CLASP), a joint National Astronomical Observatory of Japan (NAOJ) and MSFC sounding rocket mission. The CLASP camera design includes a frame-transfer e2v CCD57-10 512x512 detector, dual channel analog readout electronics and an internally mounted cold block. At the flight operating temperature of -20 C, the CLASP cameras achieved the low-noise performance requirements (less than or equal to 25 e- read noise and greater than or equal to 10 e-/sec/pix dark current), in addition to maintaining a stable gain of approximately equal to 2.0 e-/DN. The e2v CCD57-10 detectors were coated with Lumogen-E to improve quantum efficiency (QE) at the Lyman- wavelength. A vacuum ultra-violet (VUV) monochromator and a NIST calibrated photodiode were employed to measure the QE of each camera. Four flight-like cameras were tested in a high-vacuum chamber, which was configured to operate several tests intended to verify the QE, gain, read noise, dark current and residual non-linearity of the CCD. We present and discuss the QE measurements performed on the CLASP cameras. We also discuss the high-vacuum system outfitted for testing of UV and EUV science cameras at MSFC.

Champey, Patrick↗

VUV Testing of Science Cameras at MSFC: QE Measurement of the CLASP Flight Cameras

The NASA Marshall Space Flight Center (MSFC) has developed a science camera suitable for sub-orbital missions for observations in the UV, EUV and soft X-ray. Six cameras were built and tested for the Chromospheric Lyman-Alpha Spectro-Polarimeter (CLASP), a joint National Astronomical Observatory of Japan (NAOJ) and MSFC sounding rocket mission. The CLASP camera design includes a frame-transfer e2v CCD57-10 512x512 detector, dual channel analog readout electronics and an internally mounted cold block. At the flight operating temperature of -20 C, the CLASP cameras achieved the low-noise performance requirements (less than or equal to 25 e- read noise and greater than or equal to 10 e-/sec/pix dark current), in addition to maintaining a stable gain of approximately equal to 2.0 e-/DN. The e2v CCD57-10 detectors were coated with Lumogen-E to improve quantum efficiency (QE) at the Lyman- wavelength. A vacuum ultra-violet (VUV) monochromator and a NIST calibrated photodiode were employed to measure the QE of each camera. Four flight-like cameras were tested in a high-vacuum chamber, which was configured to operate several tests intended to verify the QE, gain, read noise, dark current and residual non-linearity of the CCD. We present and discuss the QE measurements performed on the CLASP cameras. We also discuss the high-vacuum system outfitted for testing of UV and EUV science cameras at MSFC.

Camera↗

Speckle imaging with the MAMA detector: Preliminary results

We report on the first successful speckle imaging studies using the Stanford University speckle interferometry system, an instrument that uses a multianode microchannel array (MAMA) detector as the imaging device. The method of producing high-resolution images is based on the analysis of so-called 'near-axis' bispectral subplanes and follows the work of Lohmann et al. (1983). In order to improve the signal-to-noise ratio in the bispectrum, the frame-oversampling technique of Nakajima et al. (1989) is also employed. We present speckle imaging results of binary stars and other objects from V magnitude 5.5 to 11, and the quality of these images is studied. While the Stanford system is capable of good speckle imaging results, it is limited by the overall quantum efficiency of the current MAMA detector (which is due to the response of the photocathode at visible wavelengths and other detector properties) and by channel saturation of the microchannel plate. Both affect the signal-to-noise ratio of the power spectrum and bispectrum.

Horch, E.↗

Phase-Sensitive Coherence and the Classical-Quantum Boundary in Ghost Imaging

The theory of partial coherence has a long and storied history in classical statistical optics. the vast majority of this work addresses fields that are statistically stationary in time, hence their complex envelopes only have phase-insensitive correlations. The quantum optics of squeezed-state generation, however, depends on nonlinear interactions producing baseband field operators with phase-insensitive and phase-sensitive correlations. Utilizing quantum light to enhance imaging has been a topic of considerable current interest, much of it involving biphotons, i.e., streams of entangled-photon pairs. Biphotons have been employed for quantum versions of optical coherence tomography, ghost imaging, holography, and lithography. However, their seemingly quantum features have been mimicked with classical-sate light, questioning wherein lies the classical-quantum boundary. We have shown, for the case of Gaussian-state light, that this boundary is intimately connected to the theory of phase-sensitive partial coherence. Here we present that theory, contrasting it with the familiar case of phase-insensitive partial coherence, and use it to elucidate the classical-quantum boundary of ghost imaging. We show, both theoretically and experimentally, that classical phase-sensitive light produces ghost imaging most closely mimicking those obtained in biphotons, and we derived the spatial resolution, image contrast, and signal-to-noise ratio of a standoff-sensing ghost imager, taking into account target-induced speckle.

coherence theory↗

Enhancement of X-ray performance with new GEC charged coupled devices (CCD)

Samples of two GEC charge coupled devices with enhanced X-ray performance have been tested. The P8607, fabricated with reduced linear dimensions, gives the lowest detector noise reported for Fe-55 with a CCD. The deep depletion device P8600-HR gives the best combination of energy resolution and quantum efficiency at 6 keV. The energy resolution vs quantum efficiency trade-off curve are discussed.

Schwartz, D. A.↗

Long-Wavelength 640 x 486 GaAs/AlGaAs Quantum Well Infrared Photodetector Snap-Shot Camera

A 9-micrometer cutoff 640 x 486 snap-shot quantum well infrared photodetector (QWIP) camera has been demonstrated. The performance of this QWIP camera is reported including indoor and outdoor imaging. The noise equivalent differential temperature (NE.deltaT) of 36 mK has been achieved at 300 K background with f/2 optics. This is in good agreement with expected focal plane array sensitivity due to the practical limitations on charge handling capacity of the multiplexer, read noise, bias voltage, and operating temperature.

Gunapala, Sarath D.↗

16 Infrared Hot Electron Transistor

Very long wavelength infrared (VWIR) photodetectors, 14 20 , are of a great interest for variety of space-borne applications. These space applications have placed stringent requirements on the performance of the infrared detectors and arrays including high detectivity, low dark current, uniformity, radiation hardness and lower power dissipation. I will discuss the development and progress of AlxGal- xAs/GaAs VWIR quantum well infrared photodetectors (QWIPs) to meet those stringent requirements and the demonstration of a 15 128x128 QWIP focal plane array camera. The noise equivalent temperature difference of the focal plane array is 30 mK at 300 K background, and operating temperature is 45 K.

Electron Transistor↗

HgCdTe Avalanche Photodiode Detectors for Airborne and Spaceborne Lidar at Infrared Wavelengths

We report results from characterizing the HgCdTe avalanche photodiode (APD) sensorchip assemblies (SCA) developed for lidar at infrared wavelength using the high density vertically integrated photodiodes (HDVIP) technique. These devices demonstrated high quantum efficiency, typically greater than 90 between 0.8 micrometers and the cut-off wavelength, greater than 600 APD gain, near unity excess noise factor, 6-10 MHz electrical bandwidth and less than 0.5 fW/Hz(exp.1/2) noise equivalent power (NEP). The detectors provide linear analog output with a dynamic range of 2-3 orders of magnitude at a fixed APD gain without averaging, and over 5 orders of magnitude by adjusting the APD and preamplifier gain settings. They have been successfully used in airborne CO2 and CH4 integrated path differential absorption (IPDA) lidar as a precursor for space lidar applications.

Sun, Xiaoli↗

Dynamical Decoupling for Measuring and Suppressing Crosstalk

Dynamical decoupling (DD) is a noise-mitigating strategy in which sequences of pulses are applied to single qubits to average out their interaction with the environment. DD has been extensively studied and demonstrated for suppressing single-qubit decoherence and can be tailored for different noise spectrum. We report another important adaptation of DD where crosstalk between qubits are suppressed. We demonstrate the efficiency of this procedure on quantum circuits on superconducting transmon-based quantum devices. We designed a family of syncopated DD sequences that effectively suppress ZZ coupling between qubit pairs, which is the dominating crosstalk form on the device. We insert DD to a quantum circuit whenever single qubits are idle (often during two-qubits gates on other qubits). While standard periodic DD suppress crosstalk between these qubits and their neighbors, the syncopated DD further decouples crosstalk between these qubits. We further designed short sequences that maximize the application of DD without adding time to the quantum circuit execution. Such DD sequences yield significant improvement of the performance of the algorithm on the hardware. The performance is further boosted by combining DD with another mitigation strategy, randomized compilation. Our work demonstrated that syncopated DD is effective and practical way to suppress crosstalk in quantum circuits and serves as a great probe to characterize the crosstalk and inform hardware design.

Quantum Computing↗

New formalism for two-photon quantum optics. I - Quadrature phases and squeezed states. II - Mathematical foundation and compact notation

A new formalism for analyzing two-photon devices, such as parametric amplifiers and phase-conjugate mirrors, is proposed in part I, focusing on the properties and the significance of the quadrature-phase amplitudes and two-mode squeezed states. Time-stationary quasi-probability noise is also detailed for the case of Gaussian noise, and uncertainty principles for the quadrature-phase amplitudes are outlined, as well as some important properties of the two-mode states. Part II establishes a mathematical foundation for the formalism, with introduction of a vector notation for compact representation of two-mode properties. Fundamental unitary operators and special quantum states are also examined with an emphasis on the two-mode squeezed states. The results are applied to a previously studied degenerate limit (epsilon = 0).

Caves, C. M.↗

Theory and Development of Position-Sensitive Quantum Calorimeters

Quantum calorimeters are being developed as imaging spectrometers for future X-ray astrophysics observatories. Much of the science to be done by these instruments could benefit greatly from larger focal-plane coverage of the detector (without increasing pixel size). An order of magnitude more area will greatly increase the science throughput of these future instruments. One of the main deterrents to achieving this goal is the complexity of the readout schemes involved. We have devised a way to increase the number of pixels from the current baseline designs by an order of magnitude without increasing the number of channels required for readout. The instrument is a high energy resolution, distributed-readout imaging spectrometer called a Position-Sensitive Transition-Edge Sensor (POST). A POST is a quantum calorimeter consisting of two Transition-Edge Sensors (TESS) on the ends of a long absorber capable of one-dimensional imaging spectroscopy. Comparing rise time and energy information from the two TESS, the position of the event in the POST is determined. The energy of the event is inferred from the sum of the two pulses. We have developed a generalized theoretical formalism for distributed-readout calorimeters and apply it to our devices. We derive the noise theory and calculate the theoretical energy resolution of a POST. Our calculations show that a 7-pixel POST with 6 keV saturation energy can achieve 2.3 eV resolution, making this a competitive design for future quantum calorimeter instruments. For this thesis we fabricated 7- and 15-pixel POSTS using Mo/Au TESs and gold absorbers, and moved from concept drawings on scraps of napkins to a 32 eV energy resolution at 1.5 keV, 7-pixel POST calorimeter.

Figueroa-Feliciano, Enectali↗