Search NASA⌕ Search

SEARCH · Search NASA

Results for “radiation detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Constraints on the Decay of 180⁢𝑚 Ta

180m Ta is a rare nuclear isomer whose decay has never been observed. Its remarkably long lifetime surpasses the half-lives of all other known β and electron capture decays due to the large K-spin differences and small energy differences between the isomeric and lower energy states. Detecting its decay presents a significant experimental challenge but could shed light on neutrino-induced nucleosynthesis mechanisms, the nature of dark matter and K-spin violation. For this study, we repurposed the Majorana Demonstrator, an experimental search for the neutrinoless double-beta decay of 76 Ge using an array of high-purity germanium detectors, to search for the decay of 180m Ta. More than 17 kilograms, the largest amount of tantalum metal ever used for such a search was installed within the ultra-low background Majorana Demonstrator detector array. In this paper we present results from the first year of Ta data taking and provide an updated limit for the 180m Ta half-life on the different decay channels. With new limits up to 1.5 × 10 19 years, we improved existing limits by one to two orders of magnitude. Furthermore, this result is the most sensitive search for a single β and electron capture decay ever achieved.

150 ≤ A ≤ 189↗

AI-optimized detector design for the future Electron-Ion Collider: the dual-radiator RICH case

Advanced detector R&D requires performing computationally intensive and detailed simulations as part of the detector-design optimization process. Here, we propose a general approach to this process based on Bayesian optimization and machine learning that encodes detector requirements. As a case study, we focus on the design of the dual-radiator Ring Imaging Cherenkov (dRICH) detector under development as a potential component of the particle-identification system at the future Electron-Ion Collider (EIC). The EIC is a US-led frontier accelerator project for nuclear physics, which has been proposed to further explore the structure and interactions of nuclear matter at the scale of sea quarks and gluons. We show that the detector design obtained with our automated and highly parallelized framework outperforms the baseline dRICH design within the assumptions of the current model. Our technique can be applied to any detector R&D, provided that realistic simulations are available.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Signatures of muonic activation in the Majorana Demonstrator

Experiments searching for very rare processes such as neutrinoless double-beta decay require a detailed understanding of all sources of background. Signals from radioactive impurities present in construction and detector materials can be suppressed using a number of well-understood techniques. Background from in situ cosmogenic interactions can be reduced by siting an experiment deep underground. However, the next generation of such experiments have unprecedented sensitivity goals of 10 28 years half-life with background rates of 10 -5 cts/(keV kg yr) in the region of interest. To achieve these goals, the remaining cosmogenic background must be well understood. In the work presented here, Majorana Demonstrator data are used to search for decay signatures of metastable germanium isotopes. Contributions to the region of interest in energy and time are estimated using simulations and compared to Demonstrator data. Correlated time-delayed signals are used to identify decay signatures of isotopes produced in the germanium detectors. A good agreement between expected and measured rate is found and different simulation frameworks are used to estimate the uncertainties of the predictions. The simulation campaign is then extended to characterize the background for the LEGEND experiment, a proposed tonne-scale effort searching for neutrinoless double-beta decay in 76 Ge .

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

An all-digital associated particle imaging system for the 3D determination of isotopic distributions

Associated particle imaging (API) is a non-destructive nuclear technique for the 3D determination of isotopic distributions. By detecting the alpha particle associated with the emitted neutron in the deuterium–tritium fusion reaction with a position- and time-resolving detector, the direction of the 14.1 MeV neutron and its time of emission can be determined. Employing this method, isotope characteristic gamma rays emitted in inelastic neutron scattering events can be correlated with the neutron interaction location. Here, an API system consisting of a sealed-type neutron generator, gamma detectors, and a position-sensitive alpha detector was designed, constructed, and characterized. The system was tested with common soil elements and shown to be sensitive to 12 C, 16 O, 28 Si, 27 Al, and 56 Fe. New aspects of our approach are the use of a yttrium–aluminum–perovskite scintillator, using a sapphire window instead of a fiber-optic faceplate for light transport to the photomultiplier, and the all-digital data acquisition system. We present a description of the system with simulations and experimental results that show a position resolution on the alpha detector of 1 mm, a depth resolution using a LaBr 3 detector of 6.2 cm, and an angular resolution of 4.5°. Additionally, we present single-element gamma response measurements for the elements mentioned above together with a comparison to Monte Carlo simulations (MCNP6).

47 OTHER INSTRUMENTATION↗

Diagnostics: Chapter 8 of the special issue: on the path to tokamak burning plasma operation

This chapter presents the activity conducted by the ITPA topical group (TG) on Diagnostics over about the last 15 years. Following a general introduction of the ITER Diagnostics led by their measurement roles, the document is organized in several subchapters detailing the design support, research and development activity conducted by each of the specialist working groups (WGs) of the TG. Please note that the magnetic diagnostics were supported at the TG without a specific WG. Their status is included in the general introduction. In the following some highlights of the subchapter’s contents are provided. Recent advances in ITER first wall (FW) diagnostics for the measurements of plasma-metallic wall interaction in support of the ITER research plan are reported. An InfraRed imaging Video Bolometer for ITER has been developed and tested on several tokamaks to measure the radiated power loss. A laser-induced breakdown spectroscopy (LIBS) technique which utilizes a pulsed laser beam to ablate locally by forming a crater, will measure local tritium inventory in the FW material. Real-time Residual Gas Analyzers will measure the neutral gas composition in a divertor port and an equatorial port during plasma operation. Due to the full metallic FW environment, the plasma-wall interaction in ITER will face several challenges such as the compromised radiated power and divertor heat flux measurements by reflection. Ray tracing and analysis codes have been developed to eliminate and correct the effects of reflection in the measurements. The characteristics of the reflecting surfaces depending on the roughness and angle of the incidence have been measured by dedicated experiments, and the results were applied to the reflection elimination. For the measurement of the metallic impurity radiation induced by eroded metallic atoms, a vacuum ultraviolet spectrometer has been developed and tested. An extensive thermonuclear diagnostic suite will be required to support the operation of ITER and the planned experimental program for future burning plasma experiments. Due to the harsh environmental conditions, the implementation of diagnostic systems in ITER is a major challenge. These conditions include high levels of neutron and gamma fluxes, neutron heating, particle bombardment. Therefore, the selection and design of diagnostic systems must take into account a number of phenomena previously unseen in diagnostic design. For this reason, the measurement of neutrons and confined or lost fast ions, with particular emphasis on alpha particles, is critical to ITER. The diagnostics associated with these measurements will be important for future plasma-burning experiments at ITER. The high neutron emission and very large plasma size in ITER make neutron diagnostics the main diagnostic method used to measure plasma parameters such as fusion power, fusion power density, ion temperature, energy of fast ions and their spatial distributions in the plasma core. Active spectroscopy techniques are methods where a neutral particle beam is injected into the plasma and information on plasma parameters is extracted from the measurement of line emission resulting from the beam-plasma interaction, either by plasma ions or by beam atoms. Spatial localization is achieved by crossing the beamline and multiple observation lines. The ITER plasma will be a high temperature, moderately dense, fully ionized collisional plasma. The plasma facing surfaces are principally metallic being fashioned from beryllium or tungsten but many other elements, arising from either structural or from operational needs, may enter this plasma. The energy range of the emitted photons range from meV (infra-red) to multi keV (x-rays) and originate from all areas of the plasma volume. The primary role of passive emission diagnostics is to identify what is in the plasma from spectral signatures. Extracting quantitative information from these measurements such as impurity content, ion temperature, rotation, degree of detachment and radiated power depends on calibrated instruments, a physics model of the atomic and molecular processes and plasma transport and an analysis workflow that takes into account environmental effects such as reflections. The particular needs for ITER have prompted a multi-machine, many-year effort to address all these aspects and this chapter reviews the work on diagnostic design, experiments and new analysis techniques. An overview of the laser diagnostics to be implemented on ITER is also provided in this paper. This includes descriptions of the Thomson scattering in the core, edge and divertor regions, polarimetry and interferometry diagnostics used for measuring plasma density and also measurements of helium density in the divertor using Laser Induced Flourescence. Techniques which can allow improvements on current measurements are also addressed in particular expanding poloidal polarimetry measurements to measure field fluctuations and proposed use of dispersion interferometery which has a number of advantages over existing methods. This paper identifies particular areas where further research and testing on existing tokamaks is useful even at this advanced stage to inform the design of diagnostics for ITER. Outstanding areas of concern for the implementation of laser diagnostics, in particular with a view to reliable operation are identified. An overview of the latest developments of microwave diagnostic systems and techniques is given. The primary focus is the contributions for ITER—the next step burning plasma experiment—which is supplemented by describing recent progress of techniques applicable for fusion experiments beyond ITER. The contributions are intentionally kept concise, and are being supplemented by a rich list of references for further studies. Radiation induced effects are receiving continuous and well-deserved attention of the ITER diagnostic community and they are in many cases one of the primary design drivers of the ITER diagnostic systems. The paper summarizes recent progress in this area focusing primarily on the ITER diagnostics but in some cases provides also outlook for the possible solutions for even more demanding radiation environment of fusion reactors beyond ITER. Despite advancements in the area of modeling and simulation of various radiation induced effects, experimental testing in a nuclear environment as close as possible to the target one is still seen as unavoidable for proper qualification of particular diagnostic functional elements. Recent advancement within three diagnostic areas: optical diagnostics, magnetics and bolometers is covered. Encouraging results on qualification of silica glass vacuum window assemblies are presented. In the area of magnetic sensors, progress of irradiation tests performed on ITER in-vessel LTCC inductive sensors is presented with outlook for novel technological approaches to inductive sensors utilizing thick printing and photolithography technologies being highlighted. Summary of advancements in the area of steady state magnetic field sensors based on Hall effect is given. New results of neutron irradiation test of the ITER borosilicate glass inserts for vacuum electrical feedthroughs are summarized finding negligible swelling at target level of neutron fluence. Off-line irradiation tests of fiber optic current sensors for plasma current measurement demonstrated that both for gamma doses up to 5 MGy and a total neutron fluence up to 10 15 cm −2 , radiation induced changes are still compatible with required measurement accuracy on ITER. The ITER bolometers are given as an example how considering radiation effects may influence the diagnostic design. Finally, outlook for future main R&D directions is outlined. All optical and laser-based diagnostics in ITER will be using mirrors to guide plasma radiation toward detectors, cameras and sensors. In the hostile plasma, radiation and particle environment the optical characteristics of diagnostic mirrors will degrade directly affecting the entire performance of involved diagnostic systems. An assessment of factors affecting mirror performance is provided. Among the prime adverse factors are deposition of plasma impurities, sputtering of mirror surface and steam ingress in the vicinity of mirrors. Within the International Tokamak Physics Activity with active support by ITER central team and domestic agencies, the structured research and development (R&D) program on mitigation of risks for diagnostic mirrors is underway. Within this program the mirror material development, the passive mitigation of mirror degradation by using diagnostic ducts and shutters along with an active mirror recovery program comprising the in-situ mirror cleaning and calibration is underway. Recent developments in diagnostic mirror R&D are described in this Chapter along with an example of their implementation of R&D solutions in ITER Infrared Thermography diagnostic. An assessment of still open engineering and physics questions, considerations on mirror risks during an early phase of ITER operation are given along with an overview of diagnostic mirror evolution in the late ITER operation stage toward the demonstration fusion power plant. Several crucial areas of diagnostic R&D outlined in ITER Research Plan are addressed. The basic control groups in a fusion reactor can be broken-down in five categories: (1) plasma position, magnetic configuration, and plasma current control, (2) profile control and confinement optimization, (3) MHD control and suppression, (4) edge dissipation control, radiation and plasma exhaust control and (5) break-down optimization. These categories are coupled via the physics (a control action in one domain will affect the other domains) and via shared actuators (e.g. ECRH for impurity accumulation avoidance, current density distribution control and MHD suppression). Consequently, a supervisory control system should determine the priority of the various control tasks, their couplings, and the interfaces with the safety and interlock system. For the systematic development of the various controllers taking the complexity of the plasma and the control system into account, a model-based approach is required. A short historical overview is given of the developments in systems and control theory and control engineering with special emphasis on those developments that are most relevant for Nuclear Fusion research and operation. An overview is given of the state of the field of fusion plasma control for the control categories. It will be shown how synthetic diagnostics are being developed in ITER and how they are used in diagnostic design and design validation and how they can be in model-based controller synthesis using relatively simple models. In modern control methods, multiple diagnostics are used to constrain relatively simple models. The constrained models provide an estimate for the state. This opens the route to state controllers, such as model predictive control. A major challenge in nuclear fusion research is the coherent combination of data from heterogeneous diagnostics and modeling codes for machine control and safety as well as physics studies. Measured data from different diagnostics often provide information about the same subset of physical parameters. Additionally, information provided by some diagnostics might be needed for the analysis of other diagnostics. A joint analysis of complementary and redundant data allows, e.g. to improve the reliability of parameter estimation, to increase the spatial and temporal resolution of profiles, to obtain synergistic effects, to consider diagnostics interdependencies and to find and resolve data inconsistencies. Physics-based modeling and parameter relationships provide additional information improving the treatment of ill-posed inversion problems. A coherent combination of all kind of available information within a probabilistic framework allows for improved data analysis results. The concept of integrated data analysis (IDA) in the framework of Bayesian probability theory is outlined and contrasted with conventional data analysis. Components of the probabilistic approach are summarized and specific ingredients beneficial for data analysis at fusion devices are discussed.

ITER↗

Considerations of Radiation-Hardened Electronics for Alpha Detectors in Molten Salt Reactors

Along with advanced generations of reactors quickly becoming reality, the need for instrumentation to provide reliable information for their safety and operation is also becoming relevant. Instrumentation-wise, molten salt reactors (MSRs) represent an especially challenging case in which detectors must survive extreme temperatures, high amounts of radiation, and a highly corrosive coolant. Adding to the complexity, tight material control and accounting must be maintained with any special nuclear material (SNM), a practice made more difficult by the nature of a loop of flowing fuel. Alpha spectroscopy offers a unique window into investigating the isotopic concentrations of actinides within just such a molten salt environment. The characteristic α emissions of specific actinide isotopes in the salt enable quantification of their concentrations. Semiconductor devices based on wide bandgap materials such as silicon carbide and gallium oxide can withstand the extreme temperatures within MSRs and offer good chemical stability with the corrosive salt. Collaborators at The Ohio State University are fabricating and testing a β gallium oxide α particle sensor that could identify actinide concentrations within the fuel salt to help improve the material control and accounting required for complicated system inherent to MSRs.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Design of multi neutron-to-gamma converter array for measuring time resolved ion temperature of inertial confinement fusion implosions

The ion temperature varying during inertial confinement fusion implosions changes the amount of Doppler broadening of the fusion products, creating subtle changes in the fusion neutron pulse as it moves away from the implosion. A diagnostic design to try to measure these subtle effects is introduced—leveraging the fast time resolution of gas Cherenkov detectors along with a multi-puck array that converts a small amount of the neutron pulse into gamma-rays, one can measure multiple snapshots of the neutron pulse at intermediate distances. Further, precise measurements of the propagating neutron pulse, specifically the variation in the peak location and the skew, could be used to infer time-evolved ion temperature evolved during peak compression.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Selection of the silicon sensor thickness for the Phase-2 upgrade of the CMS Outer Tracker

During the operation of the CMS experiment at the High-Luminosity LHC the silicon sensors of the Phase-2 Outer Tracker will be exposed to radiation levels that could potentially deteriorate their performance. Previous studies had determined that planar float zone silicon with n-doped strips on a p-doped substrate was preferred over p-doped strips on an n-doped substrate. The last step in evaluating the optimal design for the mass production of about 200 m$^{2}$ of silicon sensors was to compare sensors of baseline thickness (about 300 μm) to thinned sensors (about 240 μm), which promised several benefits at high radiation levels because of the higher electric fields at the same bias voltage. This study provides a direct comparison of these two thicknesses in terms of sensor characteristics as well as charge collection and hit efficiency for fluences up to 1.5 × 10$^{15}$ n$_{eq}$/cm$^{2}$. The measurement results demonstrate that sensors with about 300 μm thickness will ensure excellent tracking performance even at the highest considered fluence levels expected for the Phase-2 Outer Tracker.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radiation hard Ga 2 O 3 detectors for high energy physics

In this project, we explore the use of ultra-wide bandgap Ga 2 O 3 materials for fabricating next-generation radiation hard solid-state detectors for high energy physics (HEP) applications. As an emerging semiconductor, Ga 2 O 3 has ultra-wide bandgap (4.5-4.9 eV), high breakdown electric field (8 MV/cm) and much lower production cost compared with radiation hard diamond detectors, all of which make Ga 2 O 3 a great candidate material working in harsh radiation environment of future HEP experiments. The recent breakthrough of growth technologies of Ga 2 O 3 significantly improves the availability of large area single crystalline Ga 2 O 3 . We focus on an early proof-of-principle demonstration of Ga 2 O 3 detectors and conduct comprehensive material and detector characterization to evaluate the potential of the emerging Ga 2 O 3 as a new radiation-hard detector material. Our endeavors directly support the instrumentation development and update need of HEP experiments and fits very well into the DOE HEP “Detector R&D” research subprogram.

36 MATERIALS SCIENCE↗

Comparative evaluation of analogue front-end designs for the CMS Inner Tracker at the High Luminosity LHC

The CMS Inner Tracker, made of silicon pixel modules, will be entirely replaced prior to the start of the High Luminosity LHC period. One of the crucial components of the new Inner Tracker system is the readout chip, being developed by the RD53 Collaboration, and in particular its analogue front-end, which receives the signal from the sensor and digitizes it. Three different analogue front-ends (Synchronous, Linear, and Differential) were designed and implemented in the RD53A demonstrator chip. A dedicated evaluation program was carried out to select the most suitable design to build a radiation tolerant pixel detector able to sustain high particle rates with high efficiency and a small fraction of spurious pixel hits. The test results showed that all three analogue front-ends presented strong points, but also limitations. The Differential front-end demonstrated very low noise, but the threshold tuning became problematic after irradiation. Moreover, a saturation in the preamplifier feedback loop affected the return of the signal to baseline and thus increased the dead time. The Synchronous front-end showed very good timing performance, but also higher noise. For the Linear front-end all of the parameters were within specification, although this design had the largest time walk. This limitation was addressed and mitigated in an improved design. The analysis of the advantages and disadvantages of the three front-ends in the context of the CMS Inner Tracker operation requirements led to the selection of the improved design Linear front-end for integration in the final CMS readout chip.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Growth of High-Purity CsPbBr 3 Crystals for Enhanced Gamma-Ray Detection

High-quality CsPbBr 3 crystals hold significant potential for gamma-ray detection due to their remarkable optoelectronic properties. This study details an optimized production process using the Bridgman method to achieve highly pure CsPbBr 3 crystals. By implementing rigorous synthesis and purification techniques, we successfully reduced the total impurity levels to 9 ppm, as confirmed by glow discharge mass spectroscopy (GDMS). The resulting CsPbBr 3 crystals demonstrate exceptional performance, including high transparency, intense photoemission, and prolonged photoluminescence decay times. These properties facilitate superior gamma-ray detection with an energy resolution of 1.4% for the 137 Cs 662 keV gamma-rays, comparable to commercial Cd 1-x Zn x Te (CZT) detectors. Our findings underscore the critical relationship between material purity and detector performance, highlighting the potential of CsPbBr 3 as a cost-effective alternative in radiation detection applications. Further studies on defect origins and electronic states are necessary to fully leverage the capabilities of CsPbBr 3 crystals in practical high-energy radiation detection systems.

Bridgman↗

Exploring the keV-scale physics potential of CUORE

We present the analysis techniques developed to explore the keV-scale energy region of the Cryogenic Underground Observatory for Rare Events (CUORE) experiment, based on more than 2 metric ton yr of data collected over five years. By prioritizing a stricter selection over a larger exposure, we are able to optimize data selection for thresholds at 10 keV and 3 keV with 691 kg yr and 11 kg yr of data, respectively. We study how the performance varies among the 988-detector array with different detector characteristics and data-taking conditions. We achieve an average baseline resolution of 2.54 ±0.14 keV FWHM and 1.18 ±0.02 keV FWHM for the data selection at 10 keV and 3 keV, respectively. The analysis methods employed reduce the overall background by about an order of magnitude, reaching 2.06±0.05 counts/(keV kg days) and 16±2 counts/(keV kg days) at the thresholds of 10 keV and 3 keV. We evaluate for the first time the near-threshold reconstruction efficiencies of the CUORE experiment, and find these to be 50 ±2% and 26 ±4% at 10 keV and 3 keV, respectively. This analysis provides crucial insights into rare decay studies, new physics searches, and keV-scale background modeling with CUORE. We demonstrate that ton-scale cryogenic calorimeters can operate across a wide energy range, from keV to MeV, establishing their scalability as versatile detectors for rare event and dark matter physics. These findings also inform the optimization of future large mass cryogenic calorimeters to enhance the sensitivity to low-energy phenomena.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Investigation of defects in melt and solution grown perovskite CsPbBr 3 single crystals

Recently, there has been considerable interest in x-ray and gamma ray detectors with large volume and high energy resolution that operate at room temperature. To improve detector energy resolution, the carrier mobility-lifetime product needs to be increased, and the electronic trap state concentration needs to be minimized. Defect concentrations in the part per billion range can alter the charge transport and carrier recombination lifetime. In this work, thermally stimulated current spectroscopy measurements were systematically carried out in bulk halide perovskite single crystals of CsPbBr 3 over a temperature range of 80–320 K. The origins and trap parameters of CsPbBr 3 crystals from the solution growth and melt growth procedures were determined and compared. Trap concentrations were ranged from 1 × 10 11 to 1 × 10 16 cm –3 . Appreciable detector performance was observed for CsPbBr3 crystals with trap concentrations less than 1 × 10 14 cm –3 . The comparison of spectral responses of crystal samples grown using two different methods shows that, after purification, solution-grown crystals are comparable to melt-grown crystals in terms of low defect concentration and improved detector performance. Finally, for an improved mobility-lifetime product and enhanced spectral response to high energy radiation from fissile materials, trap states in either type of a crystal ingot must be reduced closer to 10 11 cm –3 .

36 MATERIALS SCIENCE↗

Demonstration of low-mode shape control in indirect-drive double shell implosions at the NIF

Double shell inertial confinement fusion is a concept for achieving robust thermonuclear burn that uses dense metal shells to compress deuterium-tritium (DT) fuel to fusion conditions. Double shell implosions are typically indirectly driven and involve a target that consists of a low-Z ablator, a foam layer, and a high-Z pusher surrounding the DT fuel. The goal of the campaign is to achieve a volumetric burn as radiation losses from the DT fuel are trapped by the opaque high-Z shell. The overall performance of double shell implosions relies on the efficient collisional transfer of kinetic energy between layers. The efficiency of this transfer (and therefore the overall performance of a given implosion) is degraded by the presence of low-mode asymmetries. P2 asymmetries are often observed in spatially resolved 2D radiographs of nominal double shell implosions. This work discusses three such experiments: one with an oblate P2 asymmetry, one with a prolate P2 asymmetry, and one with an approximate spherical symmetry. After performing a shape analysis of the oblate and prolate implosions to quantify asymmetries, these experimental results were compared with the results of hydrodynamic simulations for the two experiments. Differences between the experiment and simulation were then used to design an approximately spherical implosion by altering the incident laser cone fraction. Radiographs from the experiment that implemented the modified cone fraction show evidence of an implosion that is approximately spherical until bang time. This design is intended to serve as a point design for future studies that will seek to optimize various aspects of the double shell target.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Jefferson Lab Eta Factory Experiment and Applications of PbWO4 Calorimeters in Future Experimental Facilities

The goal of the new JLab Eta Factory (JEF) experiment, conducted with the GlueX detector in Hall D at Jefferson Lab, is to perform measurements of various ¿(') decays with a primary focus on rare neutral modes. The experiment’s physics program ranges from precision tests of low-energy QCD to searches for gauge bosons with masses below 1 GeV that could couple the Standard Model (SM) sector to the dark sector. The experiment will collect a high-statistics data sample of ¿(') mesons produced via a beam of tagged photons. The GlueX detector features a large, nearly uniform acceptance for both neutral and charged particles, enabling efficient identification of complex multi-particle final states. To meet the requirements of the JEF experiment, the inner section of the forward lead-glass calorimeter in the GlueX detector has been upgraded with lead tungstate (PbWO4) scintillating crystals. PbWO4 offers exceptional characteristics, such as a small radiation length and Molire radius, and large light yield, that make it ideal for constructing high- granularity, high-resolution, radiation-hard detectors. These properties enable excellent spatial separation and energy resolution of reconstructed electromagnetic showers, establishing PbWO4 as the material of choice for many high-precision experiments. The JEF experiment began data collection in April 2025 and will operate concurrently with the GlueX experiment, whose primary objective is the search for gluonic excitations in the meson spectrum. I will give an overview of the JEF experiment, the GlueX detector, and the feasibility of further upgrades to support future ¿ physics studies. Special attention will be given to the newly constructed PbWO4 scintillating calorimeter and recent advancements in calorimeter instrumentation.

Somov, Alexander↗

Improvements to the characterization of Agfa x-ray film for use on opacity spectroscopy diagnostics

The National Ignition Facility uses a soft x-ray opacity spectrometer for x-ray spectral imaging in high-energy-density experiments. The increased demand for a better spectral resolution prompted the investigation into the Agfa D4 film. Characterization is already under way for the film. A Manson x-ray source using six different anodes was used to expose film to the linear optical density (OD) region. This is a continuation of the previous work, and the updated analysis process is communicated here. The identified uncertainties have been reduced with the updated steps that improve the results of the characterization process. In conclusion, when the Stanford Synchrotron Radiation Lightsource Beamline 16-2 was operational, the film was characterized at that source. Its beam offered a higher fluency with a lower exposure time needed to reach saturation. Results for both sources are compared in this paper.

47 OTHER INSTRUMENTATION↗