Search NASA⌕ Search

SEARCH · Search NASA

Results for “radiometric instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Landsat-8 TIRS Thermal Radiometric Calibration Status

The Landsat-8 Thermal Infrared Sensor (TIRS) has been acquiring two-band thermal infrared images of the Earth’s surface since 2013. The calibration of the two-band system has been monitored using the on-board calibrator and validated with vicarious calibration performed by NASA/JPL and RIT since launch. Soon after launch, it was discovered that the instrument had a significant stray light effect that was affecting the radiometric calibration. The stray light was corrected in the processing system in 2017. Since then, it has become apparent that there was an additional radiometric error, based on the vicarious calibration results. With a failure within the primary electronic system and subsequent switch to the redundant electronic system, the TIRS instrument effectively has two separate calibration regimes. The vicarious calibration found a statistically significant calibration error, primarily a constant over time, in Band 11 on the primary electronics (Feb 11,2013 through March 5,2015) of about -0.6K at 300K. The calibration error in Band 10 was smaller though still statistically significant at about 0.2K at 300K. On the redundant side(March 5,2015 to present), the calibration error is more signal dependent than time dependent. Both bands are affected, with Band 10 having an error between 1K and -0.4K (between 273-320K) and Band 11 having an error between 0.8K and -1.44K (between 273-320K).This calibration error will be corrected within the USGS Landsat Product Generation System with the release of Landsat Collection-2 products. The Collection-2 release also includes a correction to the relative radiometric calibration of TIRS data. Striping as a result of poor detector-to-detector normalization has been increasing in the imagery since launch. The TIRS relative radiometric calibration will be updated based on internal calibrator data to remove the stripes on a quarterly basis. The visible stripes are generally at 0.1-0.2% level, though there are some detectors in each band that have changed by 1% or more. The Collection-2 release will result in much more uniform TIRS images.

Julia A Barsi↗

Radiometric Characterization of Hyperspectral Imagers using Multispectral Sensors

The Remote Sensing Group (RSG) at the University of Arizona has a long history of using ground-based test sites for the calibration of airborne and satellite based sensors. Often, ground-truth measurements at these test sites are not always successful due to weather and funding availability. Therefore, RSG has also automated ground instrument approaches and cross-calibration methods to verify the radiometric calibration of a sensor. The goal in the cross-calibration method is to transfer the calibration of a well-known sensor to that of a different sensor, This work studies the feasibility of determining the radiometric calibration of a hyperspectral imager using multispectral a imagery. The work relies on the Moderate Resolution Imaging Spectroradiometer (M0DIS) as a reference for the hyperspectral sensor Hyperion. Test sites used for comparisons are Railroad Valley in Nevada and a portion of the Libyan Desert in North Africa. Hyperion bands are compared to MODIS by band averaging Hyperion's high spectral resolution data with the relative spectral response of M0DlS. The results compare cross-calibration scenarios that differ in image acquisition coincidence, test site used for the calibration, and reference sensor. Cross-calibration results are presented that show agreement between the use of coincident and non-coincident image pairs within 2% in most brands as well as similar agreement between results that employ the different MODIS sensors as a reference.

McCorkel, Joel↗

Post-Launch Calibration Support for VIIRS Onboard NASA NPP Spacecraft

The NPP Instrument Calibration Support Element (NICSE) is one of the elements within the NASA NPP Science Data Segment (SDS). The primary responsibility of NICSE is to independently monitor and evaluate on-orbit radiometric and geometric performance of the Visible Infrared Imaging Radiometer Suite (VIIRS) instrument and to validate its Sensor Data Record (SDR) [1]. The NICSE interacts and works closely with other SDS Product Evaluation and Analysis Tools Elements (PEATE) and the NPP Science Team (ST) and supports their on-orbit data product calibration and validation efforts. The NICSE also works closely with the NPP Instrument Calibration Support Team (NICST) during sensor pre-launch testing in ambient and thermal vacuum environment [2]. This paper provides an overview of NICSE VIIRS sensor post-launch calibration support with a focus on the use of sensor on-board calibrators (OBC) for the radiometric calibration and characterization. It presents the current status of NICSE post-launch radiometric calibration tool development effort based on its design requirements

Xiong, Xiaoxion↗

VIIRS Version 2 Deep Blue Aerosol Products

NASA's Deep Blue aerosol project has developed global aerosol data records using consistent retrieval algorithms applied to various satellite sensors. The primary components of these data records are derived from the series of Visible Infrared Imaging Radiometer Suite (VIIRS) aboard the Suomi National Polar-orbiting Partnership (SNPP) and the National Oceanic and Atmospheric Administration or NOAA-20+ satellites as well as the Moderate Resolution Imaging Spectroradiometer (MODIS), among others. These instruments provide over 23 years of measurements with similar radiometric characteristics for aerosol retrievals. The algorithms used for the initial Version 1 SNPP VIIRS data set were based on the MODIS Collection 6.1 Deep Blue algorithm over land and Satellite Ocean Aerosol Retrieval (SOAR) algorithm over water. For VIIRS Version 2 data reprocessing, major updates have been made to the algorithm suite, including better accounting for effects of surface pressure, improved determination of surface reflectance, and the inclusion of fine-mode aerosol optical models to better represent anthropogenic aerosols over land. Cross-calibration gain factors are derived for the NOAA-20 VIIRS measurements to be consistent with the SNPP VIIRS, which allows the use of a unified algorithm package for both instruments. Comparisons against AERONET observations indicate that the Version 2 AOD data from SNPP VIIRS are significantly better than the Version 1 counterpart over land and slightly degraded over water in exchange for better spatial coverage. The AOD data from SNPP and NOAA-20 VIIRS are comparable, indicating that cross-calibration enables the creation of consistent aerosol data records using the series of VIIRS sensors.

Deep Blue↗

Obtaining Remote-Sensing Reflectance from Multiple Instrument Systems

Obtaining accurate in situ measurements of Apparent Optical Properties (AOPs) is critical to maintaining satellite data quality. One approach to ensure accuracy is to deploy several independent instruments to measure the same phenomenon. During a cruise in June 2012, off the lee coast of the island of Hawaii, repeated profiles were made with two separate radiometric systems, one from Satlantic, Inc. (Hyperpro) and the other from Biospherical Instruments, Inc. (C-Ops). The C-Ops is multispectral, while the Hyperpro is hyperspectral. Both measure above-water solar irradiance (E(sub s)), downwelling in-water irradiance (E(sub d)), and upwelling in-water radiance (L(sub u)). From these measurements remotely-sensed reflectance (R(sub rs))can be calculated and compared with satellite data. All instruments were calibrated shortly before use, and while differences are to be expected due to temporal changes and spectral weighting differences, these should be consistent and minimal. We explore these differences, and compare to data retrieved from the NASA Moderate Resolution Imaging Spectroradiometer onboard Aqua (MODIS Aqua) when available. We also examine data collection and processing protocols for these systems.

Carbon↗

Early Assessment of VIIRS On-Orbit Calibration and Support Activities

The Suomi National Polar-orbiting Partnership (S-NPP) satellite, formally the National Polar-orbiting Operational Environmental Satellite System (NPOESS) Preparatory Project (NPP), provides a bridge between current and future low-Earth orbiting weather and environmental observation satellite systems. The NASA s NPP VIIRS Characterization Support Team (VCST) is designed to assess the long term geometric and radiometric performance of the Visible Infrared Imaging Radiometer Suite (VIIRS) instrument onboard the S-NPP spacecraft and to support NPP Science Team Principal Investigators (PI) for their independent evaluation of VIIRS Environmental Data Records (EDRs). This paper provides an overview of Suomi NPP VIIRS on-orbit calibration activities and examples of sensor initial on-orbit performance. It focuses on the radiometric calibration support activities and capabilities provided by the NASA VCST.

Xiong, Xiaoxiong↗

CERES FM-5 on the NPP Spacecraft: Continuing the Earth Radiation Budget Climate Data Record

The Clouds and the Earth's Radiant Energy System (CERES) Flight Model-5 (FM-5) instrument will fly on the NPOESS Preparatory Project (NPP) spacecraft, which has a launch-readiness date in June, 2010. This mission will continue the critical Earth Radiation Budget Climate Data Record (CDR) begun by the Earth Radiation Budget Experiment (ERBE) instruments in the mid 1980 s and continued by the CERES instruments currently flying on the EOS Terra and Aqua spacecraft. Ground calibrations have been completed for FM-5 and the instrument has been delivered for integration to the spacecraft Rigorous pre-launch ground calibration is performed on each CERES unit to achieve an accuracy goal of 1% for SW flux and 0.5% for outgoing LW flux. Any ground to flight or in-flight changes in radiometer response is monitored using a protocol employing both onboard and vicarious calibration sources and experiments. Recent studies of FM-1 through FM-4 data have shown that the SW response of space based broadband radiometers can change dramatically due to optical contamination. With these changes having most impact on optical response to blue-to UV radiance, where tungsten lamps are largely devoid of output, such changes are hard to monitor accurately using existing on-board sources. This paper outlines the lessons learned on the existing CERES sensors from 30+ years of flight experience and presents a radiometric protocol to be implemented on the FM-5 instrument to ensure that its performance exceeds the stated calibration and stability goals.

Priestly, Kory↗

Halogen occultation experiment (HALOE) performance verification test procedure

The Performance Verification Test Procedure is given for the Halogen Occultation Experiment (HALOE) instrument, which is being developed in house at the Langley Research Center for the Upper Atmosphere Research Satellite (UARS). This procedure is used for comprehensive performance testing of the HALOE instrument which occurs before, during, and after flight environmental tests. The radiometric performance tests include noise, drift, linearity, instantaneous field-of-view, cal wheel gas cell characterization, and self thermal emissions. Pointer/tracker performance tests include sun sensor performance, gimbal performance, control system performance, and boresight alignment. In addition, the instrument is tested functionally in simulated orbit sequences and all command operating modes are exercised. The data analysis required for each test is specified and pass/fail criteria are given where applicable. This test will fully demonstrate the HALOE instrument's ability to achieve science mission requirements. The HALOE instrument is a gas correlation radiometer that measures vertical distribution of eight upper atmospheric constituents: O3, HCl, HF, NO, CH4, H2O, NO2, and CO2.

Mauldin, L. E., III↗

Preliminary Assessment of Suomi-NPP VIIRS On-orbit Radiometric Performance

The Visible-Infrared Imaging Radiometer Suite (VIIRS) is a key instrument on-board the Suomi National Polar-orbiting Partnership (NPP) spacecraft that was launched on October 28th 2011. VIIRS was designed to provide moderate and imaging resolution of most of the globe twice daily. It is a wide-swath (3,040 km) cross-track scanning radiometer with spatial resolutions of 370.and 740 m at nadir for imaging and moderate bands, respectively. It has 22 spectral bands covering the spectrum between 0.412 11m and 12.01 11m, including 14 reflective solar bands (RSB), 7 thermal emissive bands (TEB), and 1 day-night band (ON B). VIIRS observations are used to generate 22 environmental data products (EORs). This paper will briefly describe NPP VIIRS calibration strategies performed by the independent government team, for the initial on-orbit Intensive Calibration and Validation (ICV) activities. In addition, this paper will provide an early assessment of the sensor on-orbit radiometric performance, such as the sensor signal to noise ratios (SNRs), dual gain transition verification, dynamic range and linearity, reflective bands calibration based on the solar diffuser (SO) and solar diffuser stability monitor (SOSM), and emissive bands calibration based on the on-board blackbody calibration (OBC). A comprehensive set of performance metrics generated during the pre-launch testing program will be compared to VIIRS on-orbit early performance, and a plan for future cal/val activities and performance enhancements will be presented.

Oudrari, Hassan↗

Remote Sensing Product Verification and Validation at the NASA Stennis Space Center

Remote sensing data product verification and validation (V&V) is critical to successful science research and applications development. People who use remote sensing products to make policy, economic, or scientific decisions require confidence in and an understanding of the products' characteristics to make informed decisions about the products' use. NASA data products of coarse to moderate spatial resolution are validated by NASA science teams. NASA's Stennis Space Center (SSC) serves as the science validation team lead for validating commercial data products of moderate to high spatial resolution. At SSC, the Applications Research Toolbox simulates sensors and targets, and the Instrument Validation Laboratory validates critical sensors. The SSC V&V Site consists of radiometric tarps, a network of ground control points, a water surface temperature sensor, an atmospheric measurement system, painted concrete radial target and edge targets, and other instrumentation. NASA's Applied Sciences Directorate participates in the Joint Agency Commercial Imagery Evaluation (JACIE) team formed by NASA, the U.S. Geological Survey, and the National Geospatial-Intelligence Agency to characterize commercial systems and imagery.

Stanley, Thomas M.↗

An Inter-Comparison Exercise of Sentinel-2 Radiometric Validations Assessed by Independent Expert Groups

Copernicus is the European Union's Earth Observation and Monitoring programme, delivering free access to operational and historical environmental data to support applications in a wide range of societal benefit areas. To allow meaningful long-term environmental monitoring and robust decision-making, it is essential to ensure that satellite-retrieved products are of high quality and consistency. This paper describes the outputs of an international workshop on the radiometric calibration validation of the Copernicus Sentinel-2A and Sentinel-2B Multi-Spectral Instrument. A wide range of vicarious methodologies have been applied independently and then compared per type of target. All methods agree on the good radiometric performance of both Sentinel-2A and Sentinel-2B with respect to the mission requirements as well as on evidence of a slight bias between the two instruments. Comparisons of all these results are discussed to highlight the benefits and advantages of the methods as well as to propose potential improvements either for the methods themselves and/or for the comparison exercise.

Sentinel-2↗

Landsat 9 TIRS-2 Performance Results Based on Subsystem-Level Testing

Landsat 9 is the next in the series of Landsat satellites and has a complement of two pushbroom imagers: Operational Land Imager-2 (OLI-2) that samples the solar reflective spectrum with nine channels and Thermal Infrared Sensor-2 (TIRS-2) samples the thermal infrared spectrum with two channels. The first builds of these sensors, OLI and TIRS, were launched on Landsat 8 in 2013 and Landsat 9 is expected to launch in December 2020. TIRS-2 is designed and built to continue the Landsat data record and satisfy the needs of the remote sensing community. There are two sets of requirements considered for planning the component, subsystem and instrument level tests for TIRS-2: performance requirements and Special Calibration Test Requirements (SCTR). The performance requirements specify key spectral, spatial, radiometric, and operational parameters of TIRS-2 while the SCTRs specify parameters of how the instrument is tested. Several requirements can only be verified at the instrument level, but many performance metrics can be assessed earlier in prelaunch testing at the subsystem level. A test program called TIRS Imaging Performance and Cryoshell Evaluation (TIPCE) was developed to characterize TIRS-2 spectral, spatial, and scattered-light rejection performance at the telescope and detector subsystem level. There were three thermal vacuum campaigns in TIPCE that occurred from November 2017 to March 2018. This work shows results of TIPCE data analysis which provide confidence that key requirements will be met at instrument level with a few minor waivers. A full complement of performance testing will be done at the TIRS-2 instrument level for final verification in late 2018 through Spring 2019.

scatter↗

Investigation of techniques for correcting ERTS data for solar and atmospheric effects

The author has identified the following significant results. The design and fabrication of five radiant power measuring instruments (RPMI) for ERTS ground truth have been completed. These instruments will be deployed in concert with ERTS overflights to obtain radiometric measurements needed to determine solar and atmospheric parameters that effect ERTS radiance measurements. With these parameters, the accuracy and capability of various procedures for transforming ERTS data into absolute target reflectance signatures will be evaluated. The RPMI is a rugged, hand-carried instrument accurately calibrated to measure both downwelling and reflected radiance within each ERTS multispectral scanner band. A foldover handle permits a quick change from wide angle global or sky irradiance measurements to narrow angle radiance measurements from sky and ground targets. These measurements yield ground truth site reflectance and permit calculation of additional parameters such as beam transmittance between spacecraft and ground, and path radiance (path reflectance).

Rogers, R. H.↗

Branching Ratios for The Radiometric Calibration of EUNIS-2012

The Extreme Ultraviolet Normal Incidence Spectrograph (EUNIS) sounding rocket instrument is a two-channel imaging spectrograph that observes the solar corona and transition region with high spectral resolution and a rapid cadence made possible by unprecedented sensitivity. The upcoming flight will incorporate a new wavelength channel covering the range 524-630 Angstroms, the previously-flown 300-370 Angstroms channel, and the first flight demonstration of cooled active pixel sensor (APS) arrays. The new 524-630 Angstrom channel incorporates a Toroidal Varied Line Space (TVLS) grating coated with B4C/Ir, providing broad spectral coverage and a wide temperature range of 0.025 to 10 MK. Absolute radiometric calibration of the two channels is being performed using a hollow cathode discharge lamp and NIST-calibrated AXUV-100G photodiode. Laboratory observations of He I 584 Angstroms and He II 304 Angstroms provide absolute radiometric calibrations of the two channels at those two respective wavelengths by using the AXUV photodiode as a transfer standard. The spectral responsivity is being determined by observing line pairs with a common upper state in the spectra of Ne I-III and Ar II-III. Calculations of A-values for the observed branching ratios are in progress.

Daw, Adrian N.↗

Overview of Global Monitoring of Terrestrial Chlorophyll Fluorescence from Space

Despite the critical importance of photosynthesis for the Earth system, understanding how it is influenced by factors such as climate variability, disturbance history, and water or nutrient availability remains a challenge because of the complex interactions and the lack of GPP measurements at various temporal and spatial scales. Space observations of the sun-induced chlorophyll fluorescence (SIF) electromagnetic signal emitted by plants in the 650-850nm spectral range hold the promise of providing a new view of vegetation photosynthesis on a global basis. Global retrievals of SIF from space have recently been achieved from a number of spaceborne spectrometers originally intended for atmospheric research. Despite not having been designed for land applications, such instruments have turned out to provide the necessary spectral and radiometric sensitivity for SIF retrieval from space. The first global measurements of SIF were achieved in 2011 from spectra acquired by the Japanese GOSAT mission launched in 2009. The retrieval takes advantage of the high spectral resolution provided by GOSATs Fourier Transform Spectrometer (FTS) which allows the evaluation of the in-filling of solar Fraunhofer lines by SIF. Unfortunately, GOSAT only provides a sparse spatial sampling with individual soundings separated by several hundred kilometers. Complementary, the Global Ozone Monitoring Experiment-2 (GOME-2) instruments onboard MetOp-A and MetOp-B enable SIF retrievals since 2007 with a continuous and global spatial coverage. GOME-2 measures in the red and near-infrared (NIR) spectral regions with a spectral resolution of 0.5 nm and a pixel size of up to 40x40 km2. Most recently, another global and spatially continuous data set of SIF retrievals at 740 nm spanning the 2003-2012 time frame has been produced from ENVISATSCIAMACHY. This observational scenario has been completed by the first fluorescence data from the NASA-JPL OCO-2 mission (launched in July 2014) and the upcoming Copernicus' Sentinel 5-Precursor to be launched in early 2016. OCO-2 and TROPOMI offer the possibility of monitoring SIF globally with a 100-fold improvement in spatial and temporal resolution with respect to the current measurements from the GOSAT, GOME-2 and SCIAMACHY missions. In this contribution, we will provide an overview of existing global SIF data sets derived from space-based atmospheric spectrometers and will demonstrate the potential of such data to improve our knowledge of vegetation photosynthesis and gross primary production at the synoptic scale. We will show examples of ongoing research exploiting SIF data for an improved monitoring of photosynthetic activity in different ecosystems, including large crop belts worldwide, the Amazon rainforest and boreal evergreen forests.

vegetation agriculture satellite↗

Satellite Calibration With LED Detectors at Mud Lake

Earth-monitoring instruments in orbit must be routinely calibrated in order to accurately analyze the data obtained. By comparing radiometric measurements taken on the ground in conjunction with a satellite overpass, calibration curves are derived for an orbiting instrument. A permanent, automated facility is planned for Mud Lake, Nevada (a large, homogeneous, dry lakebed) for this purpose. Because some orbiting instruments have low resolution (250 meters per pixel), inexpensive radiometers using LEDs as sensors are being developed to array widely over the lakebed. LEDs are ideal because they are inexpensive, reliable, and sense over a narrow bandwidth. By obtaining and averaging widespread data, errors are reduced and long-term surface changes can be more accurately observed.

Hiller, Jonathan D.↗

Visible charge-coupled device (CCD) focal plane design considerations for multispectral applications

The typical Multispectral Linear Array (MLA) Instrument mission would be to gather high-resolution, radiometrically accurate earth resources data in several spectral bands over a prolonged period of time. These bands would include the visible (VIS), near infrared (NIR) and short wavelength infrared. Silicon charge-coupled imaging devices (CCDs) can be assembled into contiguous pixel focal planes which will cover the VIS/NIR region and operate reliably for several years in a space environment. A typical MLA focal plane would have approximately 12,000 pixels, with a pixel-to-pixel registration requirement on the order of + or - 0.1 pixel. The technology to assemble such focal planes has been developed and is described. The problem of polarization sensitivity associated with certain types of focal plane assemblies is addressed. Radiation effects on CCDs are also discussed, and a practical solution to the problem through the use of shielding is described.

Sadowski, H.↗