Search NASA⌕ Search

SEARCH · Search NASA

Results for “replacement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Sub-MeV ultra-compact linac for radioactive isotope sources replacement, non-destructive testing, security and medical applications

RadiaBeam Technologies, LLC has developed an inexpensive, hand-portable 180 keV electron accelerator to replace 57 Co radionuclide sources in Cascade Header Enrichment Monitor detectors. We used two innovative technologies in our design: a Ku-band (1 cm wavelength) magnetron, and a split accelerating structure design to reduce manufacturing costs. In this paper, we will discuss the accelerator, including X-ray convertor and accelerating structure design. The results of RF measurements of a Ku-band split structure prototype will also be reviewed. Other applications of Ku-band linacs include compact backscatter and transmission X-ray security inspection systems, as well as computed tomography (CT) systems for luggage and parcel screening. The main requirement for luggage inspection systems is that the X-ray source must be extremely compact. Further, the required energies should cover the range from 180 keV to 1 MeV. In this paper, we will discuss the linac’s energy scalability and other modifications that will enable our technology to address these applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SIMBAD : a sequence-independent molecular-replacement pipeline

The conventional approach to finding structurally similar search models for use in molecular replacement (MR) is to use the sequence of the target to search against those of a set of known structures. Sequence similarity often correlates with structure similarity. Given sufficient similarity, a known structure correctly positioned in the target cell by the MR process can provide an approximation to the unknown phases of the target. An alternative approach to identifying homologous structures suitable for MR is to exploit the measured data directly, comparing the lattice parameters or the experimentally derived structure-factor amplitudes with those of known structures. Here, SIMBAD , a new sequence-independent MR pipeline which implements these approaches, is presented. SIMBAD can identify cases of contaminant crystallization and other mishaps such as mistaken identity (swapped crystallization trays), as well as solving unsequenced targets and providing a brute-force approach where sequence-dependent search-model identification may be nontrivial, for example because of conformational diversity among identifiable homologues. The program implements a three-step pipeline to efficiently identify a suitable search model in a database of known structures. The first step performs a lattice-parameter search against the entire Protein Data Bank (PDB), rapidly determining whether or not a homologue exists in the same crystal form. The second step is designed to screen the target data for the presence of a crystallized contaminant, a not uncommon occurrence in macromolecular crystallography. Solving structures with MR in such cases can remain problematic for many years, since the search models, which are assumed to be similar to the structure of interest, are not necessarily related to the structures that have actually crystallized. To cater for this eventuality, SIMBAD rapidly screens the data against a database of known contaminant structures. Where the first two steps fail to yield a solution, a final step in SIMBAD can be invoked to perform a brute-force search of a nonredundant PDB database provided by the MoRDa MR software. Through early-access usage of SIMBAD , this approach has solved novel cases that have otherwise proved difficult to solve.

59 BASIC BIOLOGICAL SCIENCES↗

Online PMU Missing Value Replacement Via Event-Participation Decomposition

We introduce a new method for online Phasor Measurement Unit (PMU) missing value replacement. Our approach allows us to decompose PMU event responses into a non-dynamic component (denoted the participation factor) that can be inferred directly from the past and a dynamic component that can be inferred directly from all other PMUs (denoted the event strength). When missing values occur, we can use these two components, which do not rely on the missing index, to estimate the correct value. The method is extremely fast and can easily be used for online applications. Furthermore, extensive testing on real power system event data reveals that our approach achieves state-of-the-art performance in terms of Mean Absolute Percent Errors (MAPEs) for PMU data dropped during event periods. Here, the method also yields an interpretable and simplified view of events for further analysis and applications. The method relies only on PMU data and does not take outside information such as network topology.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Homoplasy in genome-wide analysis of rare amino acid replacements: the molecular-evolutionary basis for Vavilov's law of homologous series

Rare genomic changes (RGCs) that are thought to comprise derived shared characters of individual clades are becoming an increasingly important class of markers in genome-wide phylogenetic studies. Recently, we proposed a new type of RGCs designated RGC_CAMs (after Conserved Amino acids-Multiple substitutions) that were inferred using genome-wide identification of amino acid replacements that were: i) located in unambiguously aligned regions of orthologous genes, ii) shared by two or more taxa in positions that contain a different, conserved amino acid in a much broader range of taxa, and iii) require two or three nucleotide substitutions. When applied to animal phylogeny, the RGC_CAM approach supported the coelomate clade that unites deuterostomes with arthropods as opposed to the ecdysozoan (molting animals) clade. However, a nonnegligible level of homoplasy was detected. We provide a direct estimate of the level of homoplasy caused by parallel changes and reversals among the RGC_CAMs using 462 alignments of orthologous genes from 19 eukaryotic species. It is shown that the impact of parallel changes and reversals on the results of phylogenetic inference using RGC_CAMs cannot explain the observed support for the Coelomata clade. In contrast, the evidence in support of the Ecdysozoa clade, in large part, can be attributed to parallel changes. It is demonstrated that parallel changes are significantly more common in internal branches of different subtrees that are separated from the respective common ancestor by relatively short times than in terminal branches separated by longer time intervals. A similar but much weaker trend was detected for reversals. The observed evolutionary trend of parallel changes is explained in terms of the covarion model of molecular evolution. As the overlap between the covarion sets in orthologous genes from different lineages decreases with time after divergence, the likelihood of parallel changes decreases as well. The level of homoplasy observed here appears to be low enough to justify the utility of RGC_CAMs and other types of RGCs for resolution of hard problems in phylogeny. Parallel changes, one of the major classes of events leading to homoplasy, occur much more often in relatively recently diverged lineages than in those separated from their last common ancestor by longer time intervals of time. This pattern seems to provide the molecular-evolutionary underpinning of Vavilov's law of homologous series and is readily interpreted within the framework of the covarion model of molecular evolution.

59 BASIC BIOLOGICAL SCIENCES↗

Laboratory Evaluation of LED T8 Replacement Lamp Products

A report on a lab setting analysis involving LED lamps intended to directly replace T8 fluorescent lamps (4') showing light output, power, and economic comparisons with other fluorescent options.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Measure Guideline: Window Repair, Rehabilitation, and Replacement

This measure guideline provides information and guidance on rehabilitating, retrofitting, and replacing existing window assemblies in residential construction. The intent is to provide information regarding means and methods to improve the energy and comfort performance of existing wood window assemblies in a way that takes into consideration component durability, in-service operation, and longterm performance of the strategies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Measure Guideline: Wood Window Repair, Rehabilitation, and Replacement

This measure guideline provides information and guidance on rehabilitating, retrofitting, and replacing existing window assemblies in residential construction. The intent is to provide information regarding means and methods to improve the energy and comfort performance of existing wood window assemblies in a way that takes into consideration component durability, in-service operation, and long term performance of the strategies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Project Closeout Report for the MFC Firewater Replacement Project

The Material and Fuels Complex (MFC) Firewater Replacement Project was an indirectly funded Institutional General Plant Project (IGPP) capital acquisition initiated in July 2013 and completed in June 2016. Its purpose was to improve the capacity, redundancy and reliability of the MFC fire water and potable water systems, making them compliant with DOE O 420.1C and applicable state and federal regulations.

99 GENERAL AND MISCELLANEOUS↗

Business Case for Proactive Rooftop Unit (RTU) Replacement

This document introduces the key elements to consider in making the business case for a proactive high-efficiency RTU replacement strategy for facility maintenance staff and building engineers responsible for energy management.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Defatted Biomass of the Microalga, Desmodesmus sp., Can Replace Fishmeal in the Feeds for Atlantic salmon

Microalgal biomass is a potential feed ingredient that can replace fishmeal and ensure sustainability standards in aquaculture. To understand the efficacy of the defatted biomass from the marine microalga, Desmodesmus sp. a 70-day feeding study was performed with Atlantic salmon (Salmo salar) smolts. Three groups of fish (av. wt. 167 g) were offered either a control feed (without the microalga) or the microalga-containing (10/20%) feeds. At the end of the feeding period, the growth indices (condition factor, specific growth rate) and survival of the microalga-fed fish were not significantly different from the respective values of the control fish, but the feed conversion ratios were inferior. The proximate composition of the whole body of salmon from the three groups did not vary significantly. Compared to the control fish, the 10% alga-fed fish had lower lipid content in their filet. The protein and lipid digestibility in the three feeds did not differ significantly, but the digestibility of energy in the 10% alga-feed was significantly lower than that of the control feed. Furthermore, comparison of the distal intestinal proteome of Atlantic salmon revealed that the expressions of Alpha-2-HS-glycoprotein-like (Ahsg), Myosin-11 isoform X1 (My11) and Dihydrolipoyl dehydrogenase, mitochondrial-like (Dld) were altered by the microalgal feeding. Examination of the physiological status of the fish based on the serum antioxidant capacities did not reveal any alga-feed-related differences. Moreover, the expression of the selected immune and inflammatory marker genes and the micromorphological observations did not indicate any aberration in the intestinal health of the microalga-fed fish. It is possible to include 20% of defatted Desmodesmus sp. in the feeds of Atlantic salmon.

59 BASIC BIOLOGICAL SCIENCES↗

NextGen Technologies on the FAA's Standard Terminal Automation Replacement System

This paper describes the integration, evaluation, and results from a high-fidelity human-in-the-loop (HITL) simulation of key NASA Air Traffic Management Technology Demonstration - 1 (ATD- 1) technologies implemented in an enhanced version of the FAA's Standard Terminal Automation Replacement System (STARS) platform. These ATD-1 technologies include: (1) a NASA enhanced version of the FAA's Time-Based Flow Management, (2) a NASA ground-based automation technology known as controller-managed spacing (CMS), and (3) a NASA advanced avionics airborne technology known as flight-deck interval management (FIM). These ATD-1 technologies have been extensively tested in large-scale HITL simulations using general-purpose workstations to study air transportation technologies. These general purpose workstations perform multiple functions and are collectively referred to as the Multi-Aircraft Control System (MACS). Researchers at NASA Ames Research Center and Raytheon collaborated to augment the STARS platform by including CMS and FIM advisory tools to validate the feasibility of integrating these automation enhancements into the current FAA automation infrastructure. NASA Ames acquired three STARS terminal controller workstations, and then integrated the ATD-1 technologies. HITL simulations were conducted to evaluate the ATD-1 technologies when using the STARS platform. These results were compared with the results obtained when the ATD-1 technologies were tested in the MACS environment. Results collected from the numerical data show acceptably minor differences, and, together with the subjective controller questionnaires showing a trend towards preferring STARS, validate the ATD-1/STARS integration.

air traffic management↗

Quick-Replacement High-Temperature Superconducting Current Leads for Use in a Research Cryostat

We report the use of a series of high-temperature superconducting leads in a cryostat that require no soldering to replace in the event of a failed lead. The temperature range spanned by the leads is 50 to 3 degrees Kelvin and they typically carry currents up to 4 amperes although they have a much higher capacity in this temperature range. The leads are integrated into the cryostat by clamping both ends to gold-plated copper pads. Support of the leads over the 25-centimeter length is provided by a simple G10 strong back. Details of the clamping interface, measurements of joint resistances, and other interesting observations will be discussed.

Superconductivity↗

Beryllium‐Free β‐Rb 2 Al 2 B 2 O 7 as a Possible Deep‐Ultraviolet Nonlinear Optical Material Replacement for KBe 2 BO 3 F 2

Abstract A new beryllium‐free deep‐ultraviolet (DUV) nonlinear optical (NLO) material, β‐Rb 2 Al 2 B 2 O 7 (β‐RABO), has been synthesized and characterized. The chiral nonpolar acentric material shows second‐harmonic generation (SHG) activity at both 1064 and 532 nm with efficiencies of 2×KH 2 PO 4 and 0.4×β‐BaB 2 O 4 , respectively, and exhibits a short absorption edge below 200 nm. β‐Rb 2 Al 2 B 2 O 7 has a three‐dimensional structure of corner‐shared Al(BO 3 ) 3 O polyhedra. The discovery of β‐RABO shows that through careful synthesis and characterization, replacement of KBe 2 BO 3 F 2 (KBBF) by a Be‐free DUV NLO material is possible.

Tran, T. Thao↗

Beryllium-Free β-Rb 2 Al 2 B 2 O 7 as a Possible Deep-Ultraviolet Nonlinear Optical Material Replacement for KBe 2 BO 3 F 2

A new beryllium-free deep-ultraviolet (DUV) nonlinear optical (NLO) material, β-Rb 2 Al 2 B 2 O 7 (β-RABO), has been synthesized and characterized. The chiral nonpolar acentric material shows second-harmonic generation (SHG) activity at both 1064 and 532 nm with efficiencies of 2×KH 2 PO 4 and 0.4×β-BaB 2 O 4 , respectively, and exhibits a short absorption edge below 200 nm. β-Rb 2 Al 2 B 2 O 7 has a three-dimensional structure of corner-shared Al(BO 3 ) 3 O polyhedra. The discovery of β-RABO demonstrates that through careful synthesis and characterization, replacement of KBe 2 BO 3 F 2 (KBBF) by a Be-free DUV NLO material is possible.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fractionated and purified hybrid poplar lignins as a polyol replacement in rigid polyurethane/polyisocyanurate foams

This study introduces fractionated lignin as an innovative component in the formulation of rigid polyurethane/polyisocyanurate (PUR/PIR) foams. Low-density PUR/PIR rigid foams were prepared by replacing 80% of the petrochemical-based polyol with a hybrid poplar (HP) lignin, recovered via alkaline pretreatment, and also with a fraction of this lignin, isolated via the Aqueous Lignin Purification with Hot Agents (ALPHA) process. The as-recovered HP and ALPHA-fractionated HP lignins were characterized to determine hydroxyl content, molecular weight (Mw) distribution, and pH. Both lignin-based foams met minimum standard requirements in terms of closed cell content, compression strength, and thermal conductivity. Notably, the foams made with ALPHA-based lignin outperformed the as-recovered lignin-based foams in all measured foam properties. Moreover, the ALPHA-based foam had comparable performance to the control foam (without lignin) except for density and even surpassed the control foam in closed cell content and compressive strength. This investigation of the molecular properties of lignin suggests that significant reductions in lignin average molecular weight and polydispersity (PDI) can positively impact the properties of lignin-based rigid foams.

09 BIOMASS FUELS↗

Embolization of Spontaneous Hemarthrosis Post Total Knee Replacement

Spontaneous nonhemophiliac hemarthrosis is an unusual entity, which has been little described. We present three cases of spontaneous recurrent hemarthrosis post total knee replacement (TKR) and successful management with embolization. Three male patients were referred to our service for angiography and treatment of recurrent hemarthrosis post TKR. In all three patients antegrade ipsilateral common femoral artery punctures and selective angiography of the geniculate branches were performed with a microcatheter. Abnormal vasculature was noted in all cases. Subsequent embolization was performed with Contour (Boston Scientific, Target Vascular, Cork, Ireland) embolization particles (150-250 and 250-355 {mu}m) in two patients and microcoils in the third (TornadoR; Cook Inc., Bloomington, IN, USA). Technical success was 100%. One patient had a recurrence of symptoms requiring a repeat procedure 6 months later. No complications were encountered. Selective angiography and particle embolization is an effective technique for management of this unusual but problematic postoperative sequelae.

62 RADIOLOGY AND NUCLEAR MEDICINE↗