Search NASA⌕ Search

SEARCH · Search NASA

Results for “requirements verification”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Annual Summary Report for the Remote-Handled Low-Level Waste Disposal Facility—FY 2024

This Fiscal Year (FY) 2024 annual summary report (ASR) documents the continued adequacy of the performance assessment (PA), the composite analysis (CA), and associated operating disposal- authorization statement (ODAS) technical-basis documents for the Remote-Handled (RH) Low-Level Waste (LLW) Disposal Facility at Idaho National Laboratory (INL). Annual review of the adequacy of the PA and CA for the Remote-Handled Low-Level Waste (RHLLW) Disposal Facility ensures that conclusions of the analyses remain valid in accordance with requirements of Department of Energy (DOE) Order 435.1, “Radioactive Waste Management.” In FY 2024, no significant operational changes or other activities occurred that would cause deviation from the assumptions in the PA and CA pertaining to disposal geometry, verification of waste characteristics, tracking disposal inventories against total limits, facility-closure design, or institutional controls. Nineteen waste canister shipments were received at the RHLLW Disposal Facility, and all nineteen waste canisters were emplaced in disposal vaults.

12 - MGMT OF RADIOACTIVE AND NON-RADIOACTIVE WASTE↗

Presentation on the INL Remote-Handled Low-Level Waste Disposal Facility FY-2023 Annual Summary Report

The abstract below is from the report INL/RPT-24-76103. The powerpoint presentation contains information taken from the report. This Fiscal Year (FY) 2023 annual summary report (ASR) documents the continued adequacy of the performance assessment (PA), the composite analysis (CA) and associated operating disposal-authorization statement (ODAS) technical basis documents for the Remote Handled (RH) Low-Level Waste (LLW) Disposal Facility at Idaho National Laboratory. Annual review of the adequacy of the PA and CA for the RHLLW Disposal Facility ensures that conclusions of the analyses remain valid in accordance with requirements of Department of Energy (DOE) Order 435.1, “Radioactive Waste Management.” In FY 2023, no significant operational changes or other activities occurred that would cause deviation from the assumptions in the PA and CA pertaining to disposal geometry, verification of waste characteristics, tracking disposal inventories against total limits, facility closure design, or institutional controls. Sixteen total waste-canister shipments were received at the RHLLW Disposal Facility, and 15 total waste canisters were emplaced.

12 - MGMT OF RADIOACTIVE AND NON-RADIOACTIVE WASTE↗

Status of MQXFB Quadrupole Magnets for HL-LHC

The MQXFB magnets are superconducting quadrupoles with nominal peak field on the conductor of 11.3 T. With their magnetic length of 7.2 m, they stand as the longest Nb3Sn accelerator magnets designed and manufactured up to now. Together with the companion MQXFA 4.2 m long units, built by the US Accelerator Research Program, they are at the heart of HL-LHC, as they shall replace the inner triplet quadrupoles at either side of the ATLAS and CMS interaction regions of the LHC. This technology has benefited from many years of development, and this specific design was validated with successful short models (MQXFS, 1.2 m long). More recently, several MQXFA magnets were shown to satisfy HL-LHC requirements. In this paper, we report on the cold test results of four MQXFB magnets, focusing on performance, training, behavior after thermal and powering cycles, and field quality. We then provide an update of the overall status, including ongoing verifications of design changes at the level of the coil fabrication.

43 PARTICLE ACCELERATORS↗

Tamper-Indicating Enclosures with Visually Obvious Tamper Response (Final Project Report)

Sandia National Laboratories is developing a new method for detecting penetration of tamper - indicating enclosures (TIEs). This method incorporates the use of "bleeding" materials (analogous to visually obvious, colorful bruised skin that doesn't heal) into the design of TIEs. As designed, it will allow inspectors to use simple visual observation to detect attempts to penetrate the external surfaces of a TIE, without providing adversaries the ability to repair damage. A material of this type can enhance tamper indication of current TIEs used to support treaty verification regimes. Current TIE inspections are time - consuming and rely on subjective visual assessment by an inspector, equipment such as eddy current or camera devices, or involve approaches that may be limited due to application environment. The complexities and requirements that volumetric sealing methods (or TIEs) must address are: (1) enclosures that are non - standard in size/shape; (2) enclosures that may be inspectorate - or facility - owned; (3) finding tamper attempts that are difficult and time consuming for an inspector to locate; (4) enclosures that are reliable and durable enough to survive the conditions that exist in the operating environment (including facility handling); and (5) methods that prevent adversaries from repairing penetrations. Early project R&D [1] focused on encapsulated transition metals. Due to the challenges associated with the transition metal - based approach, a mitigation approach was investigated resulting in two separate research paths — one that involves fabricating custom TIE molds that meet the specific (size and shape) needs of safeguards equipment a nd one that can be deployed as a sprayed on or painted coating to an existing TIE or surface. The "custom mold" approach is based on creating thin layers of materials that , when penetrated, expose an inner material to O 2 which causes an irreversible color change. The "in-situ coating" approach is based on applying a sensor solution containing color changing microcapsules that bleed when the microcapsule is ruptured. The anticipated benefits of this work are passive, flexible, scalable, robust , cost-effective TIEs with visually obvious responses to tamper attempts. This provides more efficient and effective monitoring , as inspectors will require little or no additional equipment and will be able to detect tamper without extensive time - consuming visual examination. Applications include custom TIEs (cabinets , equipment enclosures or seal bodies ), or spray-coating/painting onto facility-owned items, walls or structures, or circuit boards. The paper describes research and testing completed to-date on the method and integration of select system components.

36 MATERIALS SCIENCE↗

Correct Compilation of Concurrent C Code

The CompCert compiler represents a landmark effort in program verification as both a piece of verified software and as a compiler for verified C programs. A key shortcoming of CompCert however is that it does not support multithreaded programs. Prior work to add threads to CompCert has either required major rewrites of parts of the proof or only works for well synchronized programs. The problem is that CompCert’s backward simulation derives from a forward simulation via the determinism of the semantics of intermediate representation languages. This makes the proofs in CompCert easier but also makes them incompatible with standard models of multithreading which are non-deterministic. Here we propose an alternate formulation of CompCert’s proof structure that parameterizes the existing single threaded semantics with nondeterministic behavior generated at the multithreading level. While this is an old trick where program equivalence is concerned, performing it in the context of CompCert is quite subtle. Our approach allows for expressive concurrent semantics and does not require major proof rewrites but still results in a global backward simulation for multithreaded programs.

97 MATHEMATICS AND COMPUTING↗

Modelica-json: Transforming energy models to digitize the control delivery process

Building simulation models are typically not used to generate the documentation required for bidding and project delivery of commercial building systems, or for their semantic modeling and commissioning. This paper presents a software tool that aids in digitizing the control delivery process, spanning simulation during design to implementation and formal verification during commissioning. The tool can generate from Modelica models digital documentation of control sequences. This digital documentation, along with other project drawings and specifications can be used for project bidding. It can also be used for implementation of control sequences through machineto-machine translation to commercial legacy control products, for which we are currently developing the proposed ASHRAE Standard 231P based on the presented work. Moreover, as-installed control sequences can be formally verified against the design specification, and a semantic model in Brick can be exported to aid in configuration of building analytics and fault detection. The paper presents what we believe is the first translation of a Modelica-implemented control sequence to a native implementation on a commercial control platform, using the webCTRL product line from Automated Logic. The paper also shows how a webCTRL implementation can be formally verified against its Modelica specification. These use cases have all been demonstrated with a prototype implementation that is now being further developed.

Wetter, Michael↗

A deep learning-guided automated workflow in LipidOz for detailed characterization of fungal fatty acid unsaturation by ozonolysis

Understanding fungal lipid biology and metabolism is critical for antifungal target discovery as lipids play central roles in cellular processes. Nuances in lipid structural differences can significantly impact their functions, making it necessary to characterize lipids in detail to enable and understanding of their roles in these complex systems. In particular, lipid double bond (DB) locations are an important component of lipid structure that can only be determined using a few specialized analytical techniques. Ozone-induced dissociation mass spectrometry (OzID-MS) is one such technique that uses ozone to break lipid DBs, producing pairs of characteristic fragments that allow the determination of DB positions. In this work we apply OzID-MS and LipidOz software to analyze the complex lipids of Saccharomyces cerevisiae yeast strains transfected with different fatty acid desaturases from Histoplasma capsulatum to determine the specific unsaturated lipids produce. The automated data analysis in LipidOz made the determination of DB positions from this large dataset more practical, but manual verification for all targets was still time-consuming. The DL model reduces manual involvement in data analysis, but since it was trained using mammalian lipid extracts, the prediction accuracy on yeast-derived data was reduced. We addressed both shortcomings by retraining the DL model to act as a pre-filter to prioritize targets for automated analysis, providing confident manually verified results but requiring less computational time and manual effort. Our workflow resulted in the determination of novel DB positions and enzymatic specificity.

mass spectrometry, deep learning, Lipidomics, doub↗

Verification of numerical models for seismic fluid-structure interaction analysis of internal components in liquid-filled advanced reactors

Earthquake shaking of a liquid-filled advanced reactor induces fluid-structure interaction (FSI) between the reactor vessel (tank), its internal components, and the contained liquid. Seismic design, qualification, and risk assessment of such reactors must consider fluid-structure responses, their geometries and support conditions, and three-directional seismic inputs, all of which require numerical simulations. Numerical models used for analysis of safety-related nuclear equipment must be verified and validated. Here, this paper verifies numerical models of submerged components using analytical solutions. Seismic FSI analysis of the numerical models is performed using the Arbitrary Lagrangian-Eulerian (ALE) and Incompressible Computational Fluid Dynamics (ICFD) solvers in LS-DYNA. Prior analytical solutions are reworked in this paper, and calculation errors are identified and corrected. The solutions address frequencies of two concentric cylindrical pipes filled with liquid: the inner pipe is a submerged component, and the outer pipe contains the liquid. A unitless frequency coefficient is defined and presented for pipes of different materials, filled with different liquids, and with a range of dimensions for application to advanced reactors. The numerical models are verified here by comparing the lateral frequencies of submerged components with those calculated using the corrected analytical solutions. Recommendations for verification of numerical models of internal components in advanced reactors for seismic FSI analysis are provided. Although the unitless frequency coefficients and verification procedures are developed for application to advanced nuclear reactors, they are broadly applicable to FSI analysis of submerged components in liquid-filled vessels such as storage tanks, boilers, and steam generators.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Hanford Waste Treatment Plant LAB Facility Stack Effluent Monitoring: Sampling Probe Location Qualification Evaluation

The Waste Treatment Plant laboratory (LAB) facility stack monitor locations were qualified using scale model stacks to mitigate the risk of identifying that sampling locations do not meet the qualification criteria on the full-scale stack. As required by the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999 standard, the scale model and its sampling location were geometrically similar to the actual stack and the Reynolds numbers for both the actual and model stacks were >10,000. An additional criterion is that the product of the hydraulic diameter and mean velocity (DV) of the full-scale stack must be between 1/6 DV and 6 DV of the scale model stack tests. Verification tests of the LAB stacks were performed at normal operating conditions. The minimum 1/6 DV value, along with the maximum 6 DV value from the scale model testing determines the range of conditions for which the full-scale stack may be operated and remain in compliance with the stack verification criterion. Based on these DV values, the corresponding stack flow rates for each of the LAB stacks are 625 to 47,237 scfm for LB-C2, 1,704 to 103,131 scfm for LB-S1, and 467 to 18,088 scfm for LB-S2. The remaining criteria for the stack verification to be considered valid involve the flow angle and velocity uniformity results. First, the flow angle at the full-scale stack must be =20°. Second, the velocity uniformity at the full-scale stack must be =20% coefficient of variance (COV). Finally, the velocity uniformity results for the actual and scale model stack tests must agree within 5% COV. These criteria were met through the full-scale stack tests at the LAB facility. Flow angle results were primarily less than 10 degrees, except for the LB-C2 Fan A results, which were an average of 17.6 degrees; all flow angle results were within the =20° criterion. The velocity uniformity results for each test condition averaged between 1.5 and 3.5% COV, which were all within the range of the target %COV values from the scale model tests. Based on these stack verification test results, the three LAB filtered exhaust stack sampling locations meet the qualification criteria provided in the ANSI/HPS N13.1-1999 standard for all fan operating configurations. This includes single-fan as well as dual-fan operations for LB-C2, each of the dual-fan operating conditions for LB-S1, and each single-fan operating condition for LB-S2. Further changes to the system configuration or operating conditions that are outside the bounds described in this report may require additional tests or analyses to determine compliance with the standard.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hanford Waste Treatment Plant LAB Facility Stack Effluent Monitoring: Sampling Probe Location Qualification Evaluation

The Waste Treatment Plant laboratory (LAB) facility stack monitor locations were qualified using scale model stacks to mitigate the risk of identifying that sampling locations do not meet the qualification criteria on the full-scale stack. As required by the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999 standard, the scale model and its sampling location were geometrically similar to the actual stack, and the Reynolds numbers for both the actual and model stacks were >10,000. An additional criterion is that the product of the hydraulic diameter and mean velocity (DV) of the full-scale stack must be between 1/6 DV and 6 DV of the scale model stack tests. Verification tests of the LAB stacks were performed at normal operating conditions. The minimum 1/6 DV value, along with the maximum 6 DV value from the scale model testing, determines the range of conditions for which the full-scale stack may be operated and remain in compliance with the stack verification criterion. A practical range for the full-scale stack qualification uses the average DV through 6 DV from the scale model tests to compute the corresponding flow rates. Table S1 lists the operating flow rates along with the average and maximum qualified stack flow rates for each of the LAB facility stacks. For each stack, the operating flow is below the maximum qualified stack flow, which means that the scale model test results are acceptable for stack qualification. The remaining criteria for the stack verification to be considered valid involve the flow angle and velocity uniformity results. First, the flow angle at the full-scale stack must be ≤20°. Second, the velocity uniformity at the full-scale stack must be ≤20% coefficient of variance (COV). Finally, the velocity uniformity results for the actual and scale model stack tests must agree within 5% COV. These criteria were met through the full-scale stack tests at the LAB facility. Flow angle results were primarily less than 10°, except for the LB-C2 Fan A results, which were an average of 13.7°; all flow angle results were within the ≤20° criterion. The velocity uniformity results for each test condition averaged between 1.5 and 4.1% COV, which were all within the range of the target percent coefficient of variation values from the scale model tests. Based on these stack verification test results, the three LAB filtered exhaust stack sampling locations meet the qualification criteria provided in the ANSI/HPS N13.1-1999 standard for all fan operating configurations. This includes single-fan as well as dual-fan operations for LB-C2, each of the dual-fan operating conditions for LB-S1, and each single-fan operating condition for LB-S2. Further changes to the system configuration or operating conditions that are outside the bounds described in this report may require additional tests or analyses to determine compliance with the standard.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Modular machine learning-based elastoplasticity: Generalization in the context of limited data

The development of highly accurate constitutive models for materials that undergo path-dependent processes continues to be a complex challenge in computational solid mechanics. Challenges arise both in considering the appropriate model assumptions and from the viewpoint of data availability, verification, and validation. Recently, data-driven modeling approaches have been proposed that aim to establish stress-evolution laws that avoid user-chosen functional forms by relying on machine learning representations and algorithms. However, these approaches not only require a significant amount of data but also need data that probes the full stress space with a variety of complex loading paths. Furthermore, they rarely enforce all necessary thermodynamic principles as hard constraints. Hence, they are in particular not suitable for low-data or limited-data regimes, where the first arises from the cost of obtaining the data and the latter from the experimental limitations of obtaining labeled data, which is commonly the case in engineering applications. In this work, we discuss a hybrid framework that can work on a variable amount of data by relying on the modularity of the elastoplasticity formulation where each component of the model can be chosen to be either a classical phenomenological or a data-driven model depending on the amount of available information and the complexity of the response. The method is tested on synthetic uniaxial data coming from simulations as well as cyclic experimental data for structural materials. The discovered material models are found to not only interpolate well but also allow for accurate extrapolation in a thermodynamically consistent manner far outside the domain of the training data. This ability to extrapolate from limited data was the main reason for the early and continued success of phenomenological models and the main shortcoming in machine learning-enabled constitutive modeling approaches. Training aspects and details of the implementation of these models into Finite Element simulations are discussed and analyzed.

42 ENGINEERING↗

Rate of Para-Orthohydrogen Conversion in Cryogenic Vortex Tube

Raising efficiency of the cooling process for cryogenic hydrogen and minimizing hydrogen boil-off during storage and transportation of liquid hydrogen are critically important factors for widening implementation of hydrogen-based clean energy systems. One novel approach involves utilization of relatively simple catalyzed vortex tubes, where hydrogen in the primarily para- nuclear spin isomer form is converted into the ortho- form while consuming a significant amount of heat. To design such systems effectively, better understanding is required about catalyst-assisted para-orthohydrogen conversion rates in high-speed vortical flows. In this study, a computational fluid dynamics simulation has been set up to model an experimental system with cryogenic hydrogen vortex tubes. Mesh-verification and a validation study has been conducted first for a non-catalyzed tube. Then, the rate coefficient of the para-orthohydrogen conversion of cryogenic hydrogen has been determined by matching numerical results with experimental data available for a catalyzed vortex tube. Furthermore, the presented information can help design and optimize cryogenic hydrogen cooling within vortex tubes.

08 HYDROGEN↗

Revisiting “Additional Carbon”: Tracking Atmosphere–Ecosystem Carbon Exchange to Establish Mitigation and Negative Emissions From Bio-Based Systems

Climate stabilization plans rely heavily on advanced bioenergy and bioproducts for substitution of fossil-based energy sources and materials, and increasingly, for negative emissions via the direct sequestration of biogenic carbon. Yet, there remain persistent, largely unresolved critiques of bioenergy assessment methodology, particularly in the areas of land use and biogenic carbon accounting. The concept of “additional carbon” calls for evaluating the climate performance of bio-based systems by whether feedstock production creates measurable new local agro-ecosystem uptake of carbon from the atmosphere. This concept is challenging to operationalize for first-generation biofuels, and has largely been advanced as a negative critique. However, carbon additionality is more straightforward to establish—and less critical to overall system mitigation performance—in advanced bioenergy systems. In this Perspective, I review the additional carbon critique, and why it is analytically challenging to address in first-generation biofuel systems based on conventional food crops with large existing markets. Next, I make a case that carbon additionality (1) is more readily achievable with cellulosic feedstocks, (2) is more directly observable for dedicated biomass crops, and (3) is not a strict requirement for achieving net mitigation in carbon-negative bio-based systems. I end by discussing how centering atmosphere–ecosystem carbon exchanges in bio-based system assessment could create new opportunities for enterprise-scale performance monitoring and verification, augmenting and diversifying the current reliance on model-based life-cycle assessment approaches.

54 ENVIRONMENTAL SCIENCES↗

DMTN-107: Options for Alert Production in LSST Operations Year 1

This document reviews five options for alert production in LSST Operations Year 1 (LOY1), taking into account any implications on LSST formal requirements including up-scopes, down-scopes or explicit violations. The Data Management System Science Team's preferred option for maximizing LSST science is to generate template images from as much of the data from the commissioning and/or science verification phases as possible and use them to run Difference Image Analysis and alert production during LOY1. A proposal to increase the sky area covered during commissioning via a "filler" scheduler program is also presented. As a potential moderate up-scope, this study presents an option to build interim templates on a $\sim$monthly basis during LOY1, which could increase the accessible sky area by ~1000-2000 deg**2 per month, and should be reconsidered closer to the start of Operations.

79 ASTRONOMY AND ASTROPHYSICS↗

Annual Summary Report for the Remote-Handled Low-Level Waste Disposal Facility—FY 2020

This Fiscal Year (FY) 2020 annual summary report documents the continued adequacy of the performance assessment (PA), the composite analysis (CA) and associated operating disposal-authorization statement (ODAS) technical basis documents for the Remote Handled (RH) Low-Level Waste (LLW) Disposal Facility at Idaho National Laboratory. Annual review of the adequacy of the PA and CA for the RHLLW Disposal Facility ensures that conclusions of the analyses remain valid in accordance with requirements of Department of Energy (DOE) Order 435.1 Change 1, “Radioactive Waste Management.” In FY 2020, no significant operational changes or other activities occurred that would cause deviation from the assumptions in the PA and CA pertaining to disposal geometry, verification of waste characteristics, tracking disposal inventories against total limits, facility closure design, or institutional controls. Fifteen total waste-canister shipments were received at the RHLLW Disposal Facility, and 15 total waste canisters were emplaced.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Presentation on the INL Remote-Handled Low-Level Waste Disposal Facility FY-2024 Annual Summary Report

The abstract below is from the report INL/RPT-24-82600. The powerpoint presentation contains information taken from the report. This Fiscal Year (FY) 2024 annual summary report (ASR) documents the continued adequacy of the performance assessment (PA), the composite analysis (CA), and associated operating disposal authorization statement (ODAS) technical basis documents for the Remote Handled Low Level Waste (RHLLW) Disposal Facility at Idaho National Laboratory (INL). Annual review of the adequacy of the PA and CA for RHLLW Disposal Facility ensures that conclusions of the analyses remain valid in accordance with requirements of the U.S. Department of Energy (DOE) Order 435.1, “Radioactive Waste Management.” In FY 2024, no significant operational changes or other activities occurred that would cause deviation from the assumptions in the PA and CA pertaining to disposal geometry, verification of waste characteristics, tracking disposal inventories against total limits, facility closure design, or institutional controls. Nineteen waste canister shipments were received at the RHLLW Disposal Facility, and all nineteen waste canisters were emplaced in disposal vaults.

12 - MGMT OF RADIOACTIVE AND NON-RADIOACTIVE WASTE↗

Development of the INL Thermal Energy Distribution System (TEDS) in the Modelica Eco-System for Validation and Verification

This report provides an overview on the development of the Thermal Energy Distribution System (TEDS) in the Modelica process model eco-system at Idaho National Laboratory as part of the integrated energy system initiative. Model development has led to the creation of a dynamic process model of the experimental TEDS facility housed within the Engineering Science Laboratory (ESL) at INL. The model was then used during the pre-construction phase of the experimental effort to inform experimental design (insulation requirements, bypass line placement, expected performance of components) and to test innovative control schemes prior to the initial operation. The TEDS model developed in Modelica includes the primary components of the TEDS experimental unit including: a 200kW Chromalox heater, a single-tank packed bed thermal energy storage system filled with 0.125 inch Alumina (Al 2 O 3 ), an ethylene-glycol to Therminol-66 heat exchanger, system piping, six control valves, and all associated temperature, pressure, and mass flow sensors. The model does not include nitrogen fill gas tanks, or associated overfill tanks, as these are not part of standard system control. Two simulation sets were run. The first is a five-hour test that operates as a shakedown test for the facility. This simulation puts the facility through all five potential operating modes and showcases the ability of valving, control sensors, and component controllers to meet the system demands. The second case imposes a typical summer day demand on the system from a region with mixed commercial and residential electrical needs where the generator alone cannot meet peak demand but instead requires the thermal storage unit to act as a peaking unit. Over the course of the fifteen-hour discharge cycle heat losses account for a heat loss of approximately 15°C in outlet temperature. Such heat losses would lead to a decrease in overall system efficiency and may lead to additional design changes for such designs in the future that may include a topping heater. Through commencement of this work, a systems level model of TEDS with associated control systems, sensors, piping diameters, and component capabilities has been created. This model has been utilized in the pre-experimental phase to inform system design, insulation thicknesses, and potential control schemes to operate the system effectively and safely. Once TEDS begins operation, this model will be refined, tuned, and used for validation and verification purposes.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A custom high-stability pulse generator for the test of a novel in-situ magnetic sensor developed to detect radiation damage in undulators

High-performance analog-to-digital converters (ADC) have been widely applied in many areas of science. For instance, magnetic field measurements based on the Faraday’s induction law require high-precision voltmeters to measure induced voltages. In this study in the context of free-electron lasers technology, the Magnetic Measurements Team at SLAC National Accelerator Laboratory proposed a novel in-situ radiation damage detection system (RDDS) for detecting small field variations in undulators. The system measures the flux change in a flexible printed-circuit coil attached to the magnet array during the undulator gap movement. The gap movement changes the magnetic field, which induces a voltage signal in the coil that is measured and integrated with an ADC. Although the system is capable of detecting relative flux changes better than 100 ppm, drift in the ADC’s gain or offset can cause apparent changes in the relative flux. This paper describes the first attempt to developed a high-precision verification circuit to perform ADC testing in the framework of the novel RDDS. The circuit generates a reference voltage pulse with a voltage–time integral relative precision better than 50 ppm for a few hundreds of mVs — the typical order of magnitude measured with the RDDS. The circuit’s design combines a fast and precise switch with a low-noise voltage reference. Long-term measurements allowed statistical analysis and showed that averaging the voltage–time integral of ten pulses gives the required 50 ppm stability. Moreover, reproducibility tests confirmed that the circuit’s output is invariable under small power supply instabilities and equipment shutdown. Instruments and applications designed to quantify the magnetic field by integrating voltage signals may use the pulse generator proposed in this paper for verification purposes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗