Search NASA⌕ Search

SEARCH · Search NASA

Results for “resonance ionization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Sub-ppb Oxygen Contaminant Detection in Semi-Conductor Processing

Gaseous contaminants such as oxygen, water vapor, nitrogen and hydrocarbons are often present in the processing environment in semiconductor device fabrication and in containerless materials processing. The contaminants arise as a result of outgassing from hot surfaces or they may be part of the impurities in commercial ultra-high purity gases. Among these gaseous contaminants, oxygen is the most reactive and, therefore, has the most adverse effects on the end product. There has been an intense effort at the Jet Propulsion Laboratory to develop different types of oxygen sorbents to reduce oxygen concentration in a microgravity processing environment to sub-ppb (parts-per-billion) levels. Higher concentrations can lead to rapid surface oxide formation, hence reducing the quality of semiconductor devices. If the concentration of oxygen in a processing chamber at 1000oC is in the ppb level, it will only take approximately 10 seconds for an oxide layer to form on the surface of a sample. The interaction of oxygen with the water surface can lead to the formation of localized defects in semi-conductor devices, hence decreasing the manufacturing yield. For example, efficient production of 64 Mb RAM chips requires contaminations below ppb levels. This paper describes a technique for measuring trace quantities of oxygen contaminants by recording the monoatomic negative ions, O-, using mass spectrometry. The O- formation from the e--O2 interaction utilizes the electron dissociative attachment method that is greatly enhanced at the resonant energy (6.8 eV). The device combines a small gridded electron ionizer with a compact mass spectrometer. The concentrations of oxygen have been measured using the method of standard additions by diluting O2 in N2. The lowest detection limit obtained was 1.2 kHz (O- count rate) at a concentration of 10-10, corresponding to 0.1 ppb.

Sub-ppb Contaminant↗

Effect of Inductive Coil Geometry on the Thrust Efficiency of a Microwave Assisted Discharge Inductive Plasma Accelerator

Pulsed inductive plasma thrusters [1-3] are spacecraft propulsion devices in which electrical energy is capacitively stored and then discharged through an inductive coil. The thruster is electrodeless, with a time-varying current in the coil interacting with a plasma covering the face of the coil to induce a plasma current. Propellant is accelerated and expelled at a high exhaust velocity (O(10-100 km/s)) by the Lorentz body force arising from the interaction of the magnetic field and the induced plasma current. While this class of thruster mitigates the life-limiting issues associated with electrode erosion, pulsed inductive plasma thrusters require high pulse energies to inductively ionize propellant. The Microwave Assisted Discharge Inductive Plasma Accelerator (MAD-IPA) [4, 5] is a pulsed inductive plasma thruster that addressees this issue by partially ionizing propellant inside a conical inductive coil via an electron cyclotron resonance (ECR) discharge. The ECR plasma is produced using microwaves and permanent magnets that are arranged to create a thin resonance region along the inner surface of the coil, restricting plasma formation, and in turn current sheet formation, to a region where the magnetic coupling between the plasma and the inductive coil is high. The use of a conical theta-pinch coil is under investigation. The conical geometry serves to provide neutral propellant containment and plasma plume focusing that is improved relative to the more common planar geometry of the Pulsed Inductive Thruster (PIT) [2, 3], however a conical coil imparts a direct radial acceleration of the current sheet that serves to rapidly decouple the propellant from the coil, limiting the direct axial electromagnetic acceleration in favor of an indirect acceleration mechanism that requires significant heating of the propellant within the volume bounded by the current sheet. In this paper, we describe thrust stand measurements performed to characterize the performance (specific impulse, thrust efficiency) of the MAD-IPA thruster. Impulse data are obtained at various pulse energies, mass flow rates and inductive coil. geometries. Dependencies on these experimental parameters are discussed in the context of the current sheet formation and electromagnetic plasma acceleration processes.

Hallock, Ashley↗

Non-linear enhancement of ultrafast X-ray diffraction through transient resonances

Diffraction-before-destruction imaging with ultrashort X-ray pulses can visualize non-equilibrium processes, such as chemical reactions, with sub-femtosecond precision in the native environment. Here, a nanospecimen diffracts a single X-ray flash before it disintegrates. The sample structure can be reconstructed from the coherent diffraction image (CDI). State-of-the-art X-ray snapshots lack high spatial resolution because of weak diffraction signal. Bleaching effects from photo-ionization significantly restrain image brightness scaling. We find that non-linear transient ion resonances can overcome this barrier if X-ray laser pulses are shorter than in most experiments. We compared snapshots from individual ≈ 100 nm Xe nanoparticles as a function of pulse duration and incoming X-ray fluence. Our experimental results and Monte Carlo simulations suggest that transient resonances can increase ionic scattering cross sections significantly beyond literature values. This provides a novel avenue towards substantial improvement of the spatial resolution in CDI in combination with sub-femtosecond temporal precision at the nanoscale.

47 OTHER INSTRUMENTATION↗

Active Galaxy Unification in the Era of X-Ray Polarimetry

Active galactic nuclei (AGNs), Seyfert galaxies, and quasars are powered by luminous accretion and often accompanied by winds that are powerful enough to affect the AGN mass budget, and whose observational appearance bears an imprint of processes that are happening within the central parsec around the black hole (BH). One example of such a wind is the partially ionized gas responsible for X-ray and UV absorption (warm absorbers). Here, we show that such gas will have a distinct signature when viewed in polarized X-rays. Observations of such polarization can test models for the geometry of the flow and the gas responsible for launching and collimating it. We present calculations that show that the polarization depends on the hydrodynamics of the flow, the quantum mechanics of resonance-line scattering, and the transfer of polarized X-ray light in the highly ionized moving gas. The results emphasize the three-dimensional nature of the wind for modeling spectra. We show that the polarization in the 0.1-10 keV energy range is dominated by the effects of resonance lines. We predict a 5%-25% X-ray polarization signature of type-2 objects in this energy range. These results are generalized to flows that originate from a cold torus-like structure, located approximately 1 pc from the BH, which wraps the BH and is ultimately responsible for the apparent dichotomy between type 1 and type 2 AGNs. Such signals will be detectable by future dedicated X-ray polarimetry space missions, such as the NASA Gravity and Extreme Magnetism Small Explorer SMEX, "GEMS" Swank et al. (2008).

Dorodnitsyn, A.↗

Ionization wave propagation in a He plasma jet in a controlled gas environment

Characterizing ionization wave propagation in low temperature plasma jets is critical to predicting production of reactive species and plasma–surface interactions for biomedical applications and surface functionalization. In this work, results from optical emission and laser induced fluorescence measurements of the ionization wave in a He plasma jet operating in a controlled gas environment are discussed and used for comparison with numerical modeling. Additionally, the ionization wave was observed using ICCD (Intensified Charge Coupled Device) imaging and characterized by time and spatially resolved electron density measurements using laser-collision-induced fluorescence. The plasma jet was initially characterized using pure He (nominally at 200 Torr), while varying pressure and voltage. When operating in pure He, the ionization wave broadly expands exiting the plasma tube. Increasing the operating pressure reduces the speed and isotropic expansion of the ionization wave. Furthermore, the jet operated with a humid He shroud was also studied. The humid He shroud results in the electron density increasing and having an annular profile due to the lower ionization potential of H2O compared to He and localized photoionization in the mixing region. Numerical modeling highlighted the importance of resonance radiation emitted by excited states of He, photoelectron emission from the quartz tube, and the kinetic behavior of the electrons produced by photoionization ahead of the ionization front.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Siple station experiments on wave-particle interactions in the magnetosphere

Natural and controlled whistler-mode signals have been used to study nonlinear mechanisms of wave growth and wave-wave interactions (WWI) in the magnetosphere; three general classes of WWI (triggering, suppression, and entrainment) are identified and interpreted in terms of a model based on cyclotron resonance interaction. This model is also used to estimate the wave field intensity associated with different types of WWI. A new type of triggered emission, the band-limited impulse (BLI) is interpreted in terms of the switching of phase-bunched currents. In addition, an experiment to find a threshold for the excitation of the coherent wave instability is discussed, and observed VLF wave-induced transient bursts of X-rays, light and E-region ionization enhancements are considered with regard to a step function wave interacting with all resonant electrons in a given energy range.

Helliwell, R. A.↗

Single-Cell Metabolomics with Rapid Determination of Chemical Formulas from Isotopic Fine Structures

Metabolomic measurements can provide functional readouts of cellular states and phenotypes. Here, we present a protocol for single-cell metabolomics that permits direct untargeted detection of a broad number of metabolites under ambient conditions, without the need for sample processing, and with high confidence in the discovery and identification of the molecular formulas for detected metabolites. This protocol describes combining fiber-based laser ablation electrospray ionization (f-LAESI) with a 21 Tesla Fourier transform ion cyclotron resonance mass spectrometer (21T-FTICR-MS) to obtain high confidence molecular formula information about detected metabolites. The f-LAESI source utilizes mid-infrared laser ablation through a sharp optical fiber tip, affording direct ambient analysis of cells without the need for sample processing. Using the 21T-FTICR-MS as a mass analyzer enabled measurement of the isotopic fine structure (IFS) for numerous metabolites simultaneously from single cells, and the IFSs were in turn computationally processed to rapidly determine the corresponding elemental compositions. This metabolomics technique complements other single cell omics measurement methods, helping to resolve complex molecular interactions that take place within cells unattainable from single cell transcriptomic and proteomics methods.

mass spectrometry, FTICR, FTMS, ultrahigh mass res↗

The effect of secondary autoionization on dielectronic recombination.

Demonstration that, during the process of dielectronic recombination, the energy of a recombined ion after a resonance capture and subsequent stabilization may still be higher than the first ionization limit. If that happens, a secondary autoionization can take place and reduce the recombination coefficient. The importance of this effect is considered for iron ions Fe(9+) to Fe(13+).

Blaha, M.↗

Measurements of material properties for solar cells

Measurements on two candidate materials for space flight are reported. The observed optical transmittance of aluminum films vapor deposited on fused quartz showed anomalously high transmittance thru 400 A and 600 A and showed an effective skin depth of 110 A in the latter part of the 1000 A thickness. KAPTON films are shown by their optical transmission spectra to have an energy gap for electron excitation of approximately 2.5 eV, which value depends on the thickness as manufactured. The resistance of KAPTON film to ionizing radiation is described by their optical spectra and their electron spin resonance spectra.

Castle, J. G., Jr.↗

Anomalous ionization seen in the spectra of B supergiants

An IUE survey of B supergiants has been conducted to study the persistence with spectral type of the ultraviolet resonance lines of N V, C IV and Si IV. N V is seen as late as B2.5Ia, C IV until B6Ia and Si IV throughout the range from B1.5 to B9. This is in fairly good agreement with the Auger ionization model of Cassinelli and Olson (1979). The terminal velocities are derived for the 20 stars in the sample and it is found that the ratio v(T)/v(esc) decreases monotonically with spectral type from the value of 3.0 that it has in the O spectral range to the value 1.0 at B9Ia.

Cassinelli, J. P.↗

Large-Scale Interlaboratory DI-FT-ICR MS Comparability Study Employing Various Systems

We report ultra-high resolution mass spectrometry (UHR-MS) coupled with direct infusion (DI) electrospray ionization offers a fast solution for accurate untargeted profiling. Fourier transform ion cyclotron resonance (FT-ICR) mass spectrometers have been shown to produce a wealth of insights into complex chemical systems because they enable unambiguous molecular formula assignment even if the vast majority of signals is of unknown identity. Inter-laboratory comparisons are required to apply this type of instrumentation in quality control (for food industry or pharmaceutics), large-scale environmental studies or clinical diagnostics. Extended comparisons employing different FT-ICR MS instruments with qualitative direct infusion analysis are scarce since the majority of detected compounds cannot be quantified. The extent to which observations can be reproduced by different laboratories remains unknown. We set up a preliminary study which encompassed a set of seventeen laboratories around the globe, diverse in instrumental characteristics and applications, to analyze the same sets of extracts from commercially available standard human blood plasma and Standard Reference Material (SRM) for blood plasma (SRM1950), which were delivered at different dilutions or spiked with different concentrations of pesticides. The aim of this study was to assess the extent to which the outputs of differently tuned FTICR mass spectrometers, with different technical specifications, are comparable for setting the frames of a future DI-FT-ICR MS ring trial. We concluded that a cluster of five laboratories, with diverse instrumental characteristics showed comparable and representative performance across all experiments, setting a reference to be used in a future ring trial on blood plasma.

47 OTHER INSTRUMENTATION↗

Solar atmospheric dynamics. II - Nonlinear models of the photospheric and chromospheric oscillations

The one-dimensional, nonlinear dynamics of the solar atmosphere is investigated, and models of the observed photospheric (300 s) and chromospheric (200 s) oscillations are described. These are resonances of acoustic wave cavities formed by the variation of the temperature and ionization between the subphotospheric, hydrogen convection zone and the chromosphere-corona transition region. The dependence of the oscillations upon the excitation and boundary conditions leads to the conclusion that for the observed amplitudes, the modes are independently excited and, as trapped modes, transport little if any mechanical flux. In the upper photosphere and lower chromosphere, where the two modes have comparable energy density, interference between them leads to apparent vertical phase delays which might be interpreted as evidence of an energy flux.

Leibacher, J.↗

Mass loss from red giants - Results from ultraviolet spectroscopy

New instrumentation in space, primarily the IUE spacecraft, has enabled the application of ultraviolet spectroscopic techniques to the determination of physical properties and reliable mass loss rates for red giant winds. One important result is the determination of where in the H-R diagram are found stars with hot outer atmospheres and with cool winds. So far it appears that single cool stars, except perhaps the so-called hybrid stars, have either hot outer atmospheres or cool winds but not both. The C II resonance (1335 A) and intersystem (2325 A) multiplets have been used to derive temperatures, densities, and geometrical extents for the chromospheric portions of red giant winds, with the result that the red giants and the earlier giants with hot coronae have qualitatively different chromospheres. Mass loss rates can now be derived accurately from the analysis of asymmetric emission lines, such as the Mg II resonance lines, and from P Cygni profile lines of atoms in the dominant ionization stage when a hot star is available to probe the wind of a red giant. The Zeta Aur systems, consisting of a K-M supergiant and a main sequence B star are important systems for reliable mass loss rates for the red supergiant components are becoming available.

Linsky, J. L.↗

Pitch angle diffusion of newborn ions due to intrinsic turbulence in the solar wind

The objective of the present study is to understand the interaction of the solar wind with newborn ions in far upstream regions of a comet where the level of intrinsic turbulence is moderately low. Based on the assumption that quasi-linear theory is adequate and applicable, the pitch angle diffusion process and the time evolution of the newborn ion distribution function are investigated. Numerical solutions to the quasi-linear diffusion equation, including the effect of resonance broadening and that of continuous creation of newborn ions due to the ionization process, are obtained under several assumptions and approximations. It is found that theoretical results are consistent with the Giotto observations recently reported by Neugebauer et al. (1989).

Ziebell, L. F.↗

A model of hollow cathode plasma chemistry

We have developed a new model of hollow cathode plasma chemistry based on the observation that xenon ion mobility is diffusion limited due to resonant charge exchange reactions. The model shows that vapor phase barium atoms are ionized almost immediately and electric fields accelerate the ions upstream from the emission zone. We have also applied the model to the orifice region, where the resultant ion generation profile correlates with previously reported orifice erosion.

hollow cathode↗

Photoabsorption and photoionization of N2 near the first ionization threshold

The photoabsorption and photoionization spectra of molecular nitrogen, N2, near the first ionisation threshold display numerous intense resonances that have not been satisfactorily assigned to date. Principal among these is a pair of broad resonances between 126,200 and 126,600 cm−1 commonly referred to as the ”cathedral” bands. Here, we present new double-resonance photoionization spectra in this region recorded via the 𝑎′′ 1Σ+ 𝑔,𝑣′=0 intermediate state as well as new high-resolution, vacuum-ultraviolet photoabsorption spectra of 14N2,14N15N, and 15N2 to provide additional insight into the assignment of these features. Progress towards a fully consistent interpretation of the existing data on these bands is discussed, and a route towards a comprehensive description of the N2 absorption spectrum up to the 𝐵 2Σ+ 𝑢 state of N+ 2 is proposed.

Nitrogen, vacuum ultraviolet absorption, photoioni↗

Compact Ion Source for Mass Spectrometers

Cyclotron-resonance device uses miniature components and permanent magnet for small size, low weight, and low cost. Gas molecules are ionized by electrons from hot filament. Magnetic field, acting with electrostatic drift field, causes ions to move in circles with a superimposed drift perpendicular to both fields, toward the exit. Compact source can be used for studying ion-molecule reactions by ion cyclotron-resonance methods in conventional mass spectrometer with either magnetic sector or quadrupole sector.

Anicich, V. G.↗