Search NASA⌕ Search

SEARCH · Search NASA

Results for “root cause analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

255 records · Page 15

Analysis of the Performance Characteristics of the Five-Channel Microtops II Sun Photometer for Measuring Aerosol Optical Thickness and Precipitable Water Vapor

Five Microtops II sun photometers were studied in detail at the NASA Goddard Space Flight Center (GSFC) to determine their performance in measuring aerosol optical thickness (AOT or Tau(sub alphalambda) and precipitable column water vapor (W). Each derives Tau(sub alphalambda) from measured signals at four wavelengths lambda (340, 440, 675, and 870 nm), and W from the 936 nm signal measurements. Accuracy of Tau(sub alphalambda) and W determination depends on the reliability of the relevant channel calibration coefficient (V(sub 0)). Relative calibration by transfer of parameters from a more accurate sun photometer (such as the Mauna-Loa-calibrated AERONET master sun photometer at GSFC) is more reliable than Langley calibration performed at GSFC. It was found that the factory-determined value of the instrument constant for the 936 nm filter (k= 0.7847) used in the Microtops' internal algorithm is unrealistic, causing large errors in V(sub 0(936)), Tau(sub alpha936), and W. Thus, when applied for transfer calibration at GSFC, whereas the random variation of V(aub 0) at 340 to 870 nm is quite small, with coefficients of variation (CV) in the range of 0 to 2.4%, at 936 nm the CV goes up to 19%. Also, the systematic temporal variation of V(sub 0) at 340 to 870 nm is very slow, while at 936 nm it is large and exhibits a very high dependence on W. The algorithm also computes Tau(sub alpha936) as 0.91Tau(sub alpha870), which is highly simplistic. Therefore, it is recommended to determine Tau(sub alpha936) by logarithmic extrapolation from Tau(sub alpha675) and Tau(sub alpha 870. From the operational standpoint of the Microtops, apart from errors that may result from unperceived cloud contamination, the main sources of error include inaccurate pointing to the Sun, neglecting to clean the front quartz window, and neglecting to calibrate correctly. If these three issues are adequately taken care of, the Microtops can be quite accurate and stable, with root mean square (rms) differences between corresponding retrievals from clean calibrated Microtops and the AERONET sun photometer being about +/-0.02 at 340 nm, decreasing down to about +/-0.01 at 870 nm.

Ichoku, Charles↗

High-frequency ECG

The standard ECG is by convention limited to 0.05-150 Hz, but higher frequencies are also present in the ECG signal. With high-resolution technology, it is possible to record and analyze these higher frequencies. The highest amplitudes of the high-frequency components are found within the QRS complex. In past years, the term "high frequency", "high fidelity", and "wideband electrocardiography" have been used by several investigators to refer to the process of recording ECGs with an extended bandwidth of up to 1000 Hz. Several investigators have tried to analyze HF-QRS with the hope that additional features seen in the QRS complex would provide information enhancing the diagnostic value of the ECG. The development of computerized ECG-recording devices that made it possible to record ECG signals with high resolution in both time and amplitude, as well as better possibilities to store and process the signals digitally, offered new methods for analysis. Different techniques to extract the HF-QRS have been described. Several bandwidths and filter types have been applied for the extraction as well as different signal-averaging techniques for noise reduction. There is no standard method for acquiring and quantifying HF-QRS. The physiological mechanisms underlying HF-QRS are still not fully understood. One theory is that HF-QRS are related to the conduction velocity and the fragmentation of the depolarization wave in the myocardium. In a three-dimensional model of the ventricles with a fractal conduction system it was shown that high numbers of splitting branches are associated with HF-QRS. In this experiment, it was also shown that the changes seen in HF-QRS in patients with myocardial ischemia might be due to the slowing of the conduction velocity in the region of ischemia. This mechanism has been tested by Watanabe et al by infusing sodium channel blockers into the left anterior descending artery in dogs. In their study, 60 unipolar ECGs were recorded from the entire ventricular surface and were signal-averaged and filtered in the 30-250 Hz frequency range. The results showed that the decrease noted in the HF-QRS correlated linearly with the local conduction delay. The results suggest that HF-QRS is a potent indicator of disturbed local conduction. An alternative theory is that HF-QRS reflect the shape of the original electrocardiographic signal. Bennhagen et al showed that root mean square (RMS) voltage values of the depolarization signal correlate poorly with the signal amplitude but highly with the first and second derivatives, i.e. the velocity and the acceleration of the signal. It has also been suggested that the autonomic nervous system affects HF-QRS. For example, sitting up causes significant changes in HF-QRS in some leads compared to the supine position [Douglas et al., 2006]. Unpublished results indicate that familial dysautonomic patients (both vagal and sympathetic degeneration) have very little Reduced Amplitude Zones (RAZ) formation . Athletic individuals, especially elite athletes, who have vagally-mediated changes on the conventional ECG (i.e. early repolarization, bradycardia) have increased RAZ formation. Further electrophysiological studies are needed, however, to better understand the underlying mechanisms of HF-QRS. Several investigators have studied HF-QRS in different cardiac conditions, including acute myocardial ischemia and myocardial infarction (MI). However, in order for clinicians to confidently use HF-QRS as an adjunct to standard ECG, more knowledge about the characteristics of HF-QRS is needed.

Tragardh, Elin↗

Use of Otoacousticemission Phase Change to Evaluate Countermeasures for Spaceflight-Associated Neuro-Ocular Syndrome

Spaceflight-associated neuro-ocular syndrome (SANS) is a human spaceflight risk recognized by NASA. Elevated intracranial pressure (ICP) has been implicated as a root cause of many SANS signs and symptoms, yet there is no reliable noninvasive means of monitoring ICP. We have developed a noninvasive method of monitoring ICP change that exploits ear canal acoustic and otoacoustic emission (OAE) measurements. Changed ICP alters pressure in the inner ear, leading to changes in the tension and position of middle ear (ME) components; tension of these components determines the phase of the stimulus in the ear canal and the OAE response sound transmission back through the ME. The OAE method has been validated in several studies, including our own experiments as part of the NASA Fluid Shifts study. Systematic OAE phase changes demonstrating increased ME tension (an ICP indicator) are observed as posture is changed from seated to supine to head-down tilt (HDT). This effect can be substantially mitigated by lower body negative pressure (LBNP). The OAE technique has also been used on International Space Station (ISS) crewmembers, providing evidence that ICP in microgravity is similar to that seen on the ground in the supine position. The OAE method is also a rapid and noninvasive means of assessing the effectiveness of SANS countermeasures. Here we report results from two studies which used OAEs. In the most recent study (Venous Congestion Countermeasures - VCCM), three promising countermeasures [LBNP, an impedance threshold device (ITD), and veno-occlusive thigh cuffs (VTC)] were applied individually and in combination. In our previous ITD-only study, ITD was investigated for its ability to reduce ICP and cephalic venous congestion in supine and various HDT postures. Internal jugular vein (IJV) ultrasound showed a clear decongestive effect at all postures, however OAE data showed that ITD only caused a phase decrease (tension decrease) in HDT postures. In supine, ITD appeared to INCREASE tension. This paradox leads us to hypothesize that the OAE method is not accurately representing ICP changes with countermeasures (CM), which can alter ME tension through other means, such as ME pressure (MEP) changes. More generally, the exact mechanism for observed OAE response and stimulus phase shifts are not clearly understood, specifically with regard to the effects of MEP. The VCCM study examined the effects of externally-applied MEP on OAE recordings to document the relationship between these parameters. Analysis of these data provide new insights to these OAE mechanisms, in addition to results on CM effectiveness.

Kemp, D.↗