Search NASA⌕ Search

SEARCH · Search NASA

Results for “rotating mirrors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Heat pump via charge incompressibility in a collisional magnetized multi-ion plasma

Stratification due to ion-ion friction in a magnetized multiple-ion species plasma is shown to be accompanied by a heat pump effect, identified for the first time here, transferring heat from one ion species to another as well as from one region of space to another. Here, the heat pump is produced via newly identified heating mechanisms associated with charge incompressibility and the Ettingshausen effect. Besides their academic interest, these new effects may have useful applications to plasma technologies that involve rotation or compression.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experiment definition phase shuttle laboratory: LDRL-10.6 experiment

Progress is reported in the development of the space shuttle laboratory laser data relay link. The system transmittance of various surfaces was considered in order to examine the coating tradeoffs for the beryllium mirrors. The results of six coating combinations considered are summarized. It is recommended that silver coatings be used throughout the system. Design of the pre-expander and a preliminary alignment procedure implemented to align all optical elements to the reference mechanical axis (the rotational axis of the outer gimbal bearing located between the two Gregorian telescopes) are included. The local oscillator subsystem, consisting of the laser, Stark cell, Stark cell electronics, power supply, starting circuit, and conditioning optics were completed and installed in the optimechanical subsystem and operation against a 10.6 micrometer source was attempted. Preliminary measurements of the HgCdTe mixer showed that this critical element was inoperative and in subsequent tests the receiver front end electronics had also failed. Possible reasons for these failures and corrective action and steps to prevent future recurrence are discussed.

Source record↗

Satellite sweeping in offset, tilted dipole fields

The paper presents a theory for the longitudinally averaged satellite sweeping rate in an offset, tilted dipole magnetic field. It includes the reductions in the sweeping rate when the moon radius is not large compared to the gyroradius or the azimuthal drift distance during a bounce period. With a large tilt angle between the magnetic and rotation axes, moons make large excursions in dipole L value, and more than one moon can sweep at a given L. The sweeping rate peaks at the minimum L for each moon. If the gyroradius is large, additional peaks can occur when the particle mirrors near the moon latitude. To illustrate the theory, sweeping rates are evaluated for parameters relevant to the observations at Uranus by the Voyager 2 Low Energy Charged Particles Experiment. Calculated sweeping rates for ions and electrons are typically two or three orders of magnitude less than the strong-diffusion loss rate. The observation of sweeping signatures at Uranus would imply that pitch-angle scattering there occurs at a rate far below the strong-diffusion limit, contrasting with the situation for energetic ions in the inner Jovian magnetosphere.

Paonessa, Mark T.↗

Homochirality as the signature of life: the SETH Cigar

A characteristic hallmark of life is its homochirality: all biomolecules are usually of one hand, e.g. on Earth life uses only L-amino acids for protein synthesis and not their D mirror images. It is therefore suggested that a search for extra-terrestrial life can be approached as a Search for Extra-Terrestrial Homochirality (SETH). A novel miniaturized space polarimeter, called the SETH Cigar, is described which could he used to detect optical rotation as the homochiral signature of life on other planets. Moving parts are avoided by replacing the normal rotating polarizer by multiple fixed polarizers at different angles as in the eye of the bee. It is believed that homochirality will be found in the subsurface layers on Mars as a relic of extinct life.

NASA Center ARC↗

Heterodyne Interferometer Angle Metrology

A compact, high-resolution angle measurement instrument has been developed that is based on a heterodyne interferometer. The common-path heterodyne interferometer metrology is used to measure displacements of a reflective target surface. In the interferometer setup, an optical mask is used to sample the measurement laser beam reflecting back from a target surface. Angular rotations, around two orthogonal axes in a plane perpendicular to the measurement- beam propagation direction, are determined simultaneously from the relative displacement measurement of the target surface. The device is used in a tracking telescope system where pitch and yaw measurements of a flat mirror were simultaneously performed with a sensitivity of 0.1 nrad, per second, and a measuring range of 0.15 mrad at a working distance of an order of a meter. The nonlinearity of the device is also measured less than one percent over the measurement range.

Hahn, Inseob↗

Anisotropic ultrahigh gain emission observed in rotational transitions in optically pumped HF gas.

Gain and laser oscillations are obtained on rotational transitions of the first excited vibrational state of HF gas at room temperature, resonantly pumped by the 2.7-micron lines of a pulsed HF laser. Pumping the P-branch transitions connecting the ground and first excited vibrational states produces gain at the coupled rotational transitions at 36, 42, 51, 63, 84, and 126 microns. The gain exhibits directional properties characteristic of a unidirectional amplifier predicted by a recent theory. The incremental gains of these lines are very large, in excess of 1/cm, and the lines oscillate easily without mirrors (superradiance).

Skribanowitz, N.↗

Absolute intensity measurements of the CO2 bands 401-III /backward arrow/ 000 and 411-III /backward arrow/ 010

The absolute intensities of the studied transitions of CO2 have been measured from spectra obtained under high resolution. Vibration-rotation line intensities and integrated band intensities are reported. The studied bands are characterized by origins at 7593.5 and 7584 cm to the minus 1. Spectra were obtained by an Ames' 25-m base path White-type absorption cell equipped with silver-coated mirrors together with a 5-m focal length Czerny-Turner scanning spectrometer. The procedures for calculating the widths and intensities are explained, and uncertainty limits of the reported values are considered.

Valero, F. P. J.↗

The Uranian magnetopause - Lessons from earth

Magnetic field measurements by Voyager 2 reveal differences between the Uranian magnetopause and the typical terrestrial magnetopause. In particular there are pulsations in the magnetic field at Uranus which may represent partial crossings of the magnetopause, the entry into magnetic flux ropes or the passage through mirror mode waves. Examination of terrestrial data, especially those obtained under conditions of very high plasma beta, suggests that the last possibility is the more likely. The magnetopause crossing itself is also different than those typically observed at 1 AU. It contains a magnetic field rotation of over 270 deg. While this is rare at 1 AU, an example has been found at earth where the field rotation is also greater than 270 deg. In some aspects these crossings resemble slow shocks. This also occurred at a time of high plasma beta. Thus it is concluded that plasma beta is very important in determining the structure of the magnetopause.

Russell, C. T.↗

NASA Tech Briefs, July 2005

Thin-Film Resistance Heat-Flux Sensors Circuit Indicates that Voice-Recording Disks are Nearly Full Optical Sensing of Combustion Instabilities in Gas Turbines Topics include: Crane-Load Contact Sensor; Hexagonal and Pentagonal Fractal Multiband Antennas; Multifunctional Logic Gate Controlled by Temperature; Multifunctional Logic Gate Controlled by Supply Voltage; Power Divider for Waveforms Rich in Harmonics; SCB Quantum Computers Using iSWAP and 1-Qubit Rotations; CSAM Metrology Software Tool; Update on Rover Sequencing and Visualization Program; Selecting Data from a Star Catalog; Rotating Desk for Collaboration by Two Computer Programmers; Variable-Pressure Washer; Magnetically Attached Multifunction Maintenance Rover; Improvements in Fabrication of Sand/Binder Cores for Casting; Solid Freeform Fabrication of Composite-Material Objects; Efficient Computational Model of Hysteresis; Gauges for Highly Precise Metrology of a Compound Mirror; Improved Electrolytic Hydrogen Peroxide Generator; High-Power Fiber Lasers Using Photonic Band Gap Materials; Ontology-Driven Information Integration; Quantifying Traversability of Terrain for a Mobile Robot; More About Arc-Welding Process for Making Carbon Nanotubes; Controlling Laser Spot Size in Outer Space; or Software-Reconfigurable Processors for Spacecraft.

Source record↗

Conically scanned lidar telescope using holographic optical elements

Holographic optical elements (HOE) using volume phase holograms make possible a new class of lightweight scanning telescopes having advantages for lidar remote sensing instruments. So far, the only application of HOE's to lidar has been a non-scanning receiver for a laser range finder. We introduce a large aperture, narrow field of view (FOV) telescope used in a conical scanning configuration, having a much smaller rotating mass than in conventional designs. Typically, lidars employ a large aperture collector and require a narrow FOV to limit the amount of skylight background. Focal plane techniques are not good approaches to scanning because they require a large FOV within which to scan a smaller FOV mirror or detector array. Thus, scanning lidar systems have either used a large flat scanning mirror at which the receiver telescope is pointed, or the entire telescope is steered. We present a concept for a conically scanned lidar telescope in which the only moving part is the HOE which serves as the primary collecting optic. We also describe methods by which a multiplexed HOE can be used simultaneously as a dichroic beamsplitter.

Schwemmer, Geary K.↗

Exploring Cosmic X-ray Source Polarization

Cosmic X-ray sources are expected to be polarized, either because of their asymmetry and the role of scattering in their emission or the role of magnetic fields. Polarization at other wavelengths has been useful. X-ray polarization will provide a new handle on black hole parameters, in particular the spin, on accretion flows and outflows, on neutron star spin orientations and emission mechanisms, on the quantum mechanical effects of super-strong magnetic fields of magnetars, and on the structure of supernovae shocks. The proposed Gravity and Extreme Magnetism SMEX (GEMS) will use high efficiency polarimeters behind thin foil mirrors. The statistical sensitivity and control of systematics will allow measurement of polarization fractions as small as 1% from many galactic and extragalactic sources. Targets which should be polarized at the level that GEMS can easily measure include stellar black holes, Seyfert galaxies and quasars, blazars, rotation-powered and accretion-powered pulsars, magnetars, shell supernova remnants and pulsar wind nebulae. The polarimeters are Time Projection Chambers that allow reconstruction of images of photoelectron tracks for 2-10 keV Xrays. They can be deep without sacrificing modulation. These polarimeters do not image the sky, but the telescope point spread function and detector collimation allow structure to be resolved at the 10 arcmin level. Rotation of the spacecraft is not needed for the signal measurement in the Time Projection Chambers, but provides for measurement and correction of systematic errors. It also allows a small Bragg reflection soft X-ray experiment to be included that can be used for isolated neutron stars and blazars.

Swank, Jean Hebb↗

Multiple Twinning in Nacre and Aragonite

Twinning occurs when two crystals share a coherent interface along which their lattices are mirror symmetric. Here, twinning is investigated in biogenic and geologic aragonite (CaCO 3 ) in columnar nacre from the red abalone Haliotis rufescens, sheet nacre from the black-lip pearl oyster Pinctada margaritifera, and geologic aragonite. All samples exhibit the expected single (110) twins, characterized by a 116.2° rotation of the aragonite a-axis. Surprisingly, multiple twins—double, triple, quadruple—are also observed, each involving successive 116.2° rotations of the a-axis around the c-axis. Multiple twinning is concomitant but distinct from the well-known cyclic twinning of aragonite. Multiple twinning is most prevalent in columnar nacre, reaching up to quadruple twins, most frequently occurring between nacre tablets in the same column, whereas sheet nacre and geologic aragonite exhibit up to triple twins. The frequency of twins decreases with increasing twin multiple, consistent with a physical rather than biological origin. This interpretation is supported by observations in geologic aragonite and by simulations of columnar nacre growth, which incorporate only nucleation rate, growth rate, and basic geometric constraints, yet they reproduce the observed twinning behavior in columnar nacre, reinforcing the conclusion that multiple twinning arises from physical growth mechanisms.

Schmidt, Connor A. [Univ. of Wisconsin, Madison, W↗

Analysis of infrared emission from thin adsorbates

Fuel and lubricant deposits on solid surfaces, though often of similar visual appearance, differ in composition, depending on the nature of the deposit formers and the circumstances of deposition. To help establish these relations an Infrared Emission Fourier Polarization Microspectrophotometer was constructed to record infrared spectra from the deposits on their original support. By focussing on small aggregates with a reflecting microscope objective and by discriminating against the randomly polarized blackbody radiation with a rotating polarizing filter phase-locked to an amplifier, excellent Fourier emission spectra of polarized bands could be obtained. In many instances, the microscope objective was adequate without the polarizer. The analysis was calibrated against a very thin film of polyethylene terephthalate attached to a highly reflective aluminum mirror on the sample positioner.

Lauer, J. L.↗

Experimental comparison of time synchronization techniques by means of light signals and clock transport on the rotating earth

An experiment was conducted to investigate the equivalence of two methods of time transfer in a noninertial reference frame: by means of an electromagnetic signal using laser light pulses and by means of the slow ground transport of a hydrogen maser atomic clock. The experiment may also be interpreted as an investigation of whether the one-way speeds of light in the east-west and west-east directions on the rotating earth are the same. The light pulses were sent from a laser coupled to a telescope at the NASA Goddard Optical Research Facility (GORF) in Greenbelt, Maryland to the U.S. Naval Observatory (USNO) in Washington, DC. The optical path was made possible by a 30-cm flat mirror on a water tower near GORF and a 25-cm flat mirror on top of the Washington National Cathedral near USNO. The path length was 26.0 km with an east-west component of 20.7 km. The pulses were reflected back over the same path by a portable array of corner cube reflectors. The transmission and return times were measured with a stationary Sigma Tau hydrogen maser and a University of Maryland event timer at GORF, while the times of reflection were measured with a similar maser and event timer combination carefully transported to USNO. Both timekeeping systems were housed in highly insulated enclosures and were maintained at constant temperatures to within +/- 0.1 C by microprocessor controllers. The portable system was also protected from shock and vibration by pneumatic supports. The difference delta(T) between the directly measured time of reflection according to the portable clock and the time of reflection calculated from the light pulse signal times measured by the stationary clock was determined. For a typical trip delta(T) is less than 100 ps and the corresponding limit on an anisotropy of the one-way speed of light is delta(c/c) is less than 1.5 x 10(exp -6). This the only experiment to date in which two atomic clocks were calibrated at one location, one was slowly transported to the other end of a path, and the times of transmission, reflection, and return of short light pulses sent in different directions along the path were registered.

Nelson, R. A.↗

Mirror Birefringence in a Fabry-Perot Cavity and the Detection of Vacuum Birefringence in a Magnetic Field

We discuss the effect of mirror birefringence in two optical schemes designed to detect the quantum-electrodynamics (QED) predictions of vacuum birefringence under the influence of a strong magnetic field, B. Both schemes make use of a high finesse Fabry-Perot cavity (F-P) to increase the average path length of the light in the magnetic field. The first scheme, which we called the frequency scheme, is based on measurement of the beat frequency of two orthogonal polarized laser beams in the cavity. We show that mirror birefringence contributes to the detection uncertainties in first order, resulting in a high susceptibility to small thermal disturbances. We estimate that an unreasonably high thermal stability of ~10-9 K is required to resolve the effect to 0.1%. In the second scheme, which we called the polarization rotation scheme, laser polarized at 45 relative to the B field is injected into the cavity.

Vacuum Birefringence↗

Hofstadter Topology: Noncrystalline Topological Materials at High Flux

he Hofstadter problem is the lattice analog of the quantum Hall effect and is the paradigmatic example of topology induced by an applied magnetic field. Conventionally, the Hofstadter problem involves adding ~10 4 T magnetic fields to a trivial band structure. In this work, we show that when a magnetic field is added to an initially topological band structure, a wealth of possible phases emerges. Remarkably, we find topological phases that cannot be realized in any crystalline insulators. We prove that threading magnetic flux through a Hamiltonian with a nonzero Chern number or mirror Chern number enforces a phase transition at fixed filling and that a 2D Hamiltonian with a nontrivial Kane–Mele invariant can be classified as a 3D topological insulator (TI) or 3D weak TI phase in periodic flux. We then study fragile topology protected by the product of twofold rotation and time reversal and show that there exists a higher order TI phase where corner modes are pumped by flux. We show that a model of twisted bilayer graphene realizes this phase. Our results rely primarily on the magnetic translation group that exists at rational values of the flux. The advent of Moiré lattices renders our work relevant experimentally. Due to the enlarged Moiré unit cell, it is possible for laboratory-strength fields to reach one flux per plaquette and allow access to our proposed Hofstadter topological phase.

36 MATERIALS SCIENCE↗

Pointing and figure control system for a space-based far-IR segmented telescope

A pointing and figure control system for two space-based far-IR telescopes, the 10-20 m Large Deployable Reflector and the 3.6 m Submillimeter Intermediate Mission, is described. The figure maintenance control system is designed to counter the optical elements translational and rotational changes induced by long-term thermal drifts that the support structure may experience. The pointing system applies optical truss to telescope pointing; a laser metrology system is used to transfer pointing informaton from an external fine guidance sensor to the telescope optical boresight, defined by the primary mirror, secondary mirror, and focal plane assembly.

Lau, Kenneth↗

An ultraviolet polarimeter for the Solar Maximum Mission

The Solar Maximum Mission experiment contingency will include one instrument originally designed and built for OSO-8. The engineering model of the OSO-8 High Resolution Spectrometer has been rebuilt to make it lightworthy and to encompass several new functions, including solar ultraviolet polarimetry. The rebuilt package is designated as the High Resolution Ultraviolet Spectrometer/Polarimeter. The device that enables polarimetry is a dual channel rotating waveplate system. The waveplates are magnesium fluoride and will allow measurements to be made ranging from the Lyman alpha line to near visible ultraviolet. One wavelength channel will use the polarization characteristics of the spectrometer diffraction grating as the analyzer. The second channel has a built-in four-mirror polarizer. This paper describes the polarimeter design, operation, and calibration.

Calvert, J.↗