Search NASA⌕ Search

SEARCH · Search NASA

Results for “sample minimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Combined Falling Drop/Open Port Sampling Interface System for Automated Flow Injection Mass Spectrometry

The aim of this work was to demonstrate and to evaluate the analytical performance of a combined falling drop/open port sampling interface (OPSI) system as a simple noncontact, no-carryover, automated system for flow injection analysis with mass spectrometry. The falling sample drops were introduced into the OPSI using a widely available autosampler platform utilizing low cost disposable pipet tips and conventional disposable microtiter well plates. The volume of the drops that fell onto the OPSI was in the 7–15 μL range with an injected sample volume of several hundred nanoliters. Sample drop height, positioning of the internal capillary on the sampling end of the probe, and carrier solvent flow rate were optimized for maximum signal. Sample throughput, signal reproducibility, matrix effects, and quantitative analysis capability of the system were established using the drug molecule propranolol and its isotope labeled internal standard in water, unprocessed river water and two commercially available buffer matrices. A sample-to-sample throughput of ~45 s with a ~4.5 s base-to-base flow injection peak profile was obtained in these experiments. In addition, quantitation with minimally processed rat plasma samples was demonstrated with three different statin drugs (atorvastatin, rosuvastatin, and fluvastatin). Direct characterization capability of unprocessed samples was demonstrated by the analysis of neat vegetable oils. Employing the autosampler system for spatially resolved liquid extraction surface sampling exemplified by the analysis of propranolol and its hydroxypropranolol glucuronide phase II metabolites from a rat thin tissue section was also illustrated.

47 OTHER INSTRUMENTATION↗

Shock compression of liquid helium and helium-hydrogen mixtures : development of a cryogenic capability for shock compression of liquid helium on Z, final report for LDRD Project 141536.

This final report on SNL/NM LDRD Project 141536 summarizes progress made toward the development of a cryogenic capability to generate liquid helium (LHe) samples for high accuracy equation-of-state (EOS) measurements on the Z current drive. Accurate data on He properties at Mbar pressures are critical to understanding giant planetary interiors and for validating first principles density functional simulations, but it is difficult to condense LHe samples at very low temperatures (<3.5 K) for experimental studies on gas guns, magnetic and explosive compression devices, and lasers. We have developed a conceptual design for a cryogenic LHe sample system to generate quiescent superfluid LHe samples at 1.5-1.8 K. This cryogenic system adapts the basic elements of a continuously operating, self-regulating {sup 4}He evaporation refrigerator to the constraints of shock compression experiments on Z. To minimize heat load, the sample holder is surrounded by a double layer of thermal radiation shields cooled with LHe to 5 K. Delivery of LHe to the pumped-He evaporator bath is controlled by a flow impedance. The LHe sample holder assembly features modular components and simplified fabrication techniques to reduce cost and complexity to levels required of an expendable device. Prototypes have been fabricated, assembled, and instrumented for initial testing.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of deflector mode for spin-resolved time-of-flight photoemission spectroscopy

Spin- and angle-resolved photoemission spectroscopy (“spin-ARPES”) is a powerful technique for probing the spin degree-of-freedom in materials with nontrivial topology, magnetism, and strong correlations. Spin-ARPES faces severe experimental challenges compared to conventional ARPES attributed to the dramatically lower efficiency of its detection mechanism, making it crucial for instrumentation developments that improve the overall performance of the technique. Here in this paper, we demonstrate the functionality of our spin-ARPES setup based on time-of-flight spectroscopy and introduce our recent development of an electrostatic deflector mode to map out spin-resolved band structures without sample rotation. We demonstrate the functionality by presenting the spin-resolved spectra of the topological insulator Bi2Te3 and describe in detail the spectrum calibrations based on numerical simulations. By implementing the deflector mode, we minimize the need for sample rotation during measurements, hence improving the overall efficiency of experiments on small or inhomogeneous samples.

47 OTHER INSTRUMENTATION↗

Development of an In Situ Fission Gas Release Instrument for Fuel Sample Irradiations in the High Flux Isotope Reactor

Experimental measurement of gaseous fission product release with respect to temperature and burnup is a critical aspect of understanding nuclear fuel performance, validating predictive models, and qualifying new fuels. To measure this phenomenon in real-time, Oak Ridge National Laboratory has developed an instrument for measuring in situ fission gas release from small-scale fuel samples irradiated in the High Flux Isotope Reactor (HFIR). The instrument uses a continuous flow of Heover the fuel samples to sweep gaseous fission products from a sealed capsule in the HFIR Be reflector to an instrument station adjacent to the reactor. The instrument station houses two high-purity germanium (HPGe) detectors that measure decay gamma rays from fission products passing through a room temperature dwell chamber placed over the detector crystal. The sealed capsules in the reactor are designed to modulate fuel sample temperatures between 700 and 1,100°C by changing the Ar/He gas mixture surrounding the capsules during irradiation. N-type thermocouples are incorporated into the capsule housing to record real-time fuel temperatures. The capsules are heated primarily by prompt gamma rays emitted from the HFIR core with minimal heat contributions from fission in the fuel samples to minimize temperature gradients in the specimens for separate-effects characterization of the material. This paper describes modeling of time-dependent nuclear heating and fission product formation in fuel samples, thermal characteristics of the in-core capsules, and expected gaseous fission product gamma spectra at the HPGe instrument station.

Mulligan, Padhraic L [ORNL] (ORCID:000000025826540↗

Toward high-resolution NMR spectroscopy of microscopic liquid samples

A longstanding limitation of high-resolution NMR spectroscopy is the requirement for samples to have macroscopic dimensions. Commercial probes, for example, are designed for volumes of at least 5 mL, in spite of decades of work directed toward the goal of miniaturization. Progress in miniaturizing inductive detectors has been limited by a perceived need to meet two technical requirements: (1) minimal separation between the sample and the detector, which is essential for sensitivity, and (2) near-perfect magnetic-field homogeneity at the sample, which is typically needed for spectral resolution. The first of these requirements is real, but the second can be relaxed, as we demonstrate here. By using pulse sequences that yield high-resolution spectra in an inhomogeneous field, we eliminate the need for near-perfect field homogeneity and the accompanying requirement for susceptibility matching of microfabricated detector components. With this requirement removed, typical imperfections in microfabricated components can be tolerated, and detector dimensions can be matched to those of the sample, even for samples of volume << 5 uL. Pulse sequences that are robust to field inhomogeneity thus enable small-volume detection with optimal sensitivity. We illustrate the potential of this approach to miniaturization by presenting spectra acquired with a flat-wire detector that can easily be scaled to subnanoliter volumes. In particular, we report high-resolution NMR spectroscopy of an alanine sample of volume 500 pL.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Characterization of Lithium Ion Battery Materials with Valence Electron Energy-Loss Spectroscopy

Abstract Cutting-edge research on materials for lithium ion batteries regularly focuses on nanoscale and atomic-scale phenomena. Electron energy-loss spectroscopy (EELS) is one of the most powerful ways of characterizing composition and aspects of the electronic structure of battery materials, particularly lithium and the transition metal mixed oxides found in the electrodes. However, the characteristic EELS signal from battery materials is challenging to analyze when there is strong overlap of spectral features, poor signal-to-background ratios, or thicker and uneven sample areas. A potential alternative or complementary approach comes from utilizing the valence EELS features (<20 eV loss) of battery materials. For example, the valence EELS features in LiCoO 2 maintain higher jump ratios than the Li–K edge, most notably when spectra are collected with minimal acquisition times or from thick sample regions. EELS maps of these valence features give comparable results to the Li–K edge EELS maps of LiCoO 2 . With some spectral processing, the valence EELS maps more accurately highlight the morphology and distribution of LiCoO 2 than the Li–K edge maps, especially in thicker sample regions. This approach is beneficial for cases where sample thickness or beam sensitivity limit EELS analysis, and could be used to minimize electron dosage and sample damage or contamination.

energy storage (including batteries and capacitors↗

WHONDRS River Corridor Surface Water Metabolites and Geochemistry from Global Sites

This dataset supports a broader study examining the character of organic matter that may be delivered to subsurface sediments via hydrologic exchange. To implement the global survey, free stream sampling kits were provided to interested volunteers throughout the world. Samples were collected with minimal constraints in terms of location, but following strict protocols, and shipped for metabolomic analysis via Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS). In addition, basic geochemistry analyses (e.g., dissolved organic matter concentration) were conducted, standardized photos of each field system were taken, and extensive metadata were captured. Sampling began in 2018 and is ongoing as of 2025. This dataset is comprised of one folders of field photos, one folder of raw Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS) data, and one main data folder containing (1) file-level metadata; (2) data dictionary; (3) field metadata; (4) readme; (5) international generic sample number (IGSN) mapping file; (6) field protocol; and (7) a subfolder with sample data. The sample data subfolder contains (1) surface water dissolved organic carbon (DOC, measured as non-purgeable organic carbon, NPOC) data and averages; (2) methods codes; (3) surface water FTICR methods; and (4) a subfolder of 12 Tesla (12T) FTICR-MS data. This folder contains three subfolders, one containing the.xml files, one containing the CoreMS output files, and the other containing instructions and scripts for processing the files in CoreMS (https://github.com/EMSL-Computing/CoreMS). All files are .csv, .pdf, .R, .xml, .html, .Rmd, .py, .cal, .json, .jpg, .jpeg, or .png. For details on how to navigate data packages generated by this project, see https://data.ess-dive.lbl.gov/portals/PNNLRiverCorridorSFA/About.

Biogeochemistry↗

Development of Methods for In-line Monitoring of Yield Stress During the Transfer of Radioactive Waste - 20435

Radioactive waste slurries at the Savannah River Site (SRS) and Hanford often behave as non-Newtonian fluids with a yield stress. The yield stress increases the size of equipment needed to transport or mix these slurries and can increase the risk of process upsets. This property is often measured by collection of samples and transportation to a laboratory, which can increase the risk of personnel exposure and even change the rheology. In addition, slurry rheology has been observed to change with time. Real-time in-line monitoring (RTIM) of rheological properties of slurries can have substantial benefits to critical processes which are currently in operation or will be part of future plans in Department of Energy (DOE) complex processes. The need for an appropriate RTIM technology that can potentially minimize or eliminate numerous sampling operations was recently identified. This research at Florida International University focuses on addressing the need for a reliable RTIM technology at US Department of Energy sites. The objective of this work is to investigate and develop appropriate and reliable technologies that can perform accurate and easy measurements of yield stress with minimal changes to the flow conditions at US Department of Energy sites. Use of ultrasound in longitudinal and shear modes was considered as a method for monitoring of yield stress variations with no disturbance to the flow. Measurement of shear wave velocity (in shear mode) and monitoring of sound velocity variations with start of flow from rest (longitudinal mode) are the underlying principles. Measurement of pressure loss and liquid rise (due to static differential pressure) during flow of slurries were two other methods that were considered and investigated. In addition, analysis of stability depth of a penetrometer in slurry medium (penetrometer method) revealed a potential suitability. This paper presents efforts associated with investigation of different methods mentioned earlier for kaolin-water mixtures at different concentrations. Theoretical analysis showed that all methods under investigation were capable of monitoring yield stress in a desirable range of 0 to 70 pascal. A bench scale test setup was constructed for investigation of pressure loss and liquid rise methods. Simulants at different concentrations were created for initial testing campaigns. For ultrasonic testing, effects of yield stress on sound propagation speed in longitudinal and shear modes were investigated for simulants placed inside PVC pipes. Parameters such as simulant concentration and pipe diameter were varied to find optimal values. It was found that spacing (or medium thickness) of 1/8 inch or less was necessary to observe echoes with sufficient strength. In addition, a significant effect of yield stress on sound propagation velocity was observed. For the liquid rise method, kaolin-water simulant at 1.17 specific gravity was pumped through a 1/4 inch pipe and liquid height was measured in a vertical riser branching off a three-way connection. Static gauge pressure was varied within [0.3 to 1.1] psi range by increase of pumping pressure and flow. Results showed consistent yield stress data within 10% deviation from values reported by a rheometer. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Rapid Analysis of Carbohydrates in Bioprocess Samples: An Evaluation of the CarboPac SA10 for HPAE-PAD Analysis by Interlaboratory Comparison

A technique for carbohydrate analysis for bioprocess samples has been developed, providing reduced analysis time compared to current practice in the biofuels R&D community. The Thermofisher CarboPac SA10 anion-exchange column enables isocratic separation of monosaccharides, sucrose and cellobiose in approximately 7 minutes. Additionally, use of a low-volume (0.2 mL) injection valve in combination with a high-volume detection cell minimizes the extent of sample dilution required to bring sugar concentrations into the linear range of the pulsed amperometric detector (PAD). Three laboratories, representing academia, industry, and government, participated in an interlaboratory study which analyzed twenty-one opportunistic samples representing biomass pretreatment, enzymatic saccharification, and fermentation samples. The technique's robustness, linearity, and interlaboratory reproducibility were evaluated and showed excellent-to-acceptable characteristics. Additionally, quantitation by the CarboPac SA10/PAD was compared with the current practice method utilizing a HPX-87P/RID. While these two methods showed good agreement a statistical comparison found significant quantitation difference between them, highlighting the difference between selective and universal detection modes.

09 BIOMASS FUELS↗

Tabletop soft x-ray absorption spectroscopy for molecular fingerprinting

For applications related to nuclear security, safeguards, and nonproliferation, it is often critical to know the molecular compositions of lanthanide- and actinide-containing samples. Spectroscopy is a widely used tool that looks at the interaction between light and matter: Different species absorb or emit light at unique wavelengths which act as signatures. However, there is a limited number of tools that can achieve high-sensitivity, accurate measurements of lanthanide and actinide molecular compositions. Candidate methods include mass spectrometry, which usually destroys at least part of the sample and requires complicated stoichiometry to guess the original sample’s molecular compositions; optical spectroscopies, which have great atomic but limited molecular sensitivities or other drawbacks which make sensing molecules difficult like limited light sources or strong absorption in the atmosphere; and nuclear spectroscopies (gamma, neutron) which also have limited sources and long (>minute) collection times. As such, the purpose of our research is to develop a new tool to better distinguish between subtle differences in molecules containing lanthanides and actinides. Soft x-ray spectroscopy is sensitive to molecular form and is minimally intrusive/nondestructive to the sample. However, soft x-ray light with sufficient brightness for spectroscopy is typically limited to user-facilities like synchrotrons or free electron lasers, where beamtimes are competitive, and work with radiological materials may be difficult or entirely prohibited. To overcome this issue, our Team has developed a custom tabletop laser-driven, soft x-ray light source which employs high harmonic generation (HHG). Soft x-ray spectroscopy can distinguish between subtly different molecules, in the spectral range which we need to study these heavy elements. A tabletop system provides an effective and affordable tool to find both the elemental and chemical specificity of lanthanide and samples. Creating a light source in the soft x-ray spectrum is difficult because these wavelengths in the range 5-20 nm (20-350 eV photon energies) only penetrate several 100s of nm in most solid materials and only reflect well in shallow, grazing incident angles. The results are applicable to nuclear forensics, because molecular fingerprinting of lanthanide and actinide samples can be used to back out the origin and processing method of nuclear materials (Skrodzki, et al.).

36 MATERIALS SCIENCE↗

Manifold Sampling for Optimization of Nonconvex Functions That Are Piecewise Linear Compositions of Smooth Components

Here, we develop a manifold sampling algorithm for the minimization of a nonsmooth composite function $f \triangleq \psi + h \circ F$ when $\psi$ is smooth with known derivatives, $h$ is a known, nonsmooth, piecewise linear function, and $F$ is smooth but expensive to evaluate. The trust-region algorithm classifies points in the domain of $h$ as belonging to different manifolds and uses this knowledge when computing search directions. Since $h$ is known, classifying objective manifolds using only the values of $F$ is simple. We prove that all cluster points of the sequence of the manifold sampling algorithm iterates are Clarke stationary; this holds although points evaluated by the algorithm are not assumed to be differentiable and when only approximate derivatives of $F$ are available. Numerical results show that manifold sampling using zeroth-order information about $F$ is competitive with algorithms that employ exact subgradient values from $\partial f$.

97 MATHEMATICS AND COMPUTING↗

High-throughput mass spectrometry analysis using immediate drop-on-demand technology coupled with an open port sampling interface

Rationale: The sampling throughput of immediate drop-on-demand technology (I.DOT) coupled with an open port sampling interface (OPSI) is limited by software communication. To enable much-needed high-throughput mass spectrometry (MS) analysis capabilities, a novel software was developed that allows for flexible sample selection from a 96-well plate and for maximized analysis throughput using I.DOT/OPSI-MS coupling. Methods: Wells of a 96-well I.DOT plate were filled with propranolol solution and were used to test maximum sampling throughput strategies to minimize analysis time. Demonstration of chemical reaction monitoring was done using acid-catalyzed ring closure of 2,3-diaminonaphthalene (DAN) with nitrite to form 2,3-naphthotriazole (NAT). Analytes were detected in positive electrospray ionization mode using selected reaction monitoring. Results: A maximum throughput of 1.54 s/sample (7.41 min/96-well plate with three technical replicates) was achieved, and it was limited by the peak width of the MS signal resulting in an occasional slight overlap between the peaks. Further, relative standard deviation was 10 ± 1% with all tested sampling strategies. Chemical reaction monitoring of DAN to NAT using nitrite was successfully accomplished with 2 s/sample throughout showing almost complete transformation in 10 min with no signal overlap. Conclusions: This work illustrates the development of a noncontact, automated I.DOT/OPSI-MS system with improved throughput achieved through an optimized software interface. Its achievable analysis time and precision make it a viable approach for drug discovery and in situ reaction monitoring studies.

47 OTHER INSTRUMENTATION↗

A microfluidic flow-cell for the study of the ultrafast dynamics of biological systems

The study of biochemical dynamics by ultrafast spectroscopic methods is often restricted by the limited amount of liquid sample available, while the high repetition rate of light sources can induce photodamage. In order to overcome these limitations, we designed a high flux, sub-ml, capillary flow-cell. While the 0.1 mm thin window of the 0.5 mm cross-section capillary ensures an optimal temporal resolution and a steady beam deviation, the cell-pump generates flows up to ~0.35 ml/s that are suitable to pump laser repetition rates up to ~14 kHz, assuming a focal spot-diameter of 100 μm. In addition, a decantation chamber efficiently removes bubbles and allows, via septum, for the addition of chemicals while preserving the closed atmosphere. The minimal useable amount of sample is ~250 μl.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

4D-STEM of Beam-Sensitive Materials

We report that a scanning electron nanobeam diffraction, or 4D-STEM (four-dimensional scanning transmission electron microscopy), is a flexible and powerful approach to elucidate structure from "soft" materials that are challenging to image in the transmission electron microscope because their structure is easily damaged by the electron beam. In a 4D-STEM experiment, a converged electron beam is scanned across the sample, and a pixelated camera records a diffraction pattern at each scan position. This four-dimensional data set can be mined for various analyses, producing maps of local crystal orientation, structural distortions, crystallinity, or different structural classes. Holding the sample at cryogenic temperatures minimizes diffusion of radicals and the resulting damage and disorder caused by the electron beam. The total fluence of incident electrons can easily be controlled during 4D-STEM experiments by careful use of the beam blanker, steering of the localized electron dose, and by minimizing the fluence in the convergent beam thus minimizing beam damage. This technique can be applied to both organic and inorganic materials that are known to be beam-sensitive; they can be highly crystalline, semicrystalline, mixed phase, or amorphous. One common example is the case for many organic materials that have a π-π stacking of polymer chains or rings on the order of 3.4-4.2 Å separation. If these chains or rings are aligned in some regions, they will produce distinct diffraction spots (as would other crystalline spacings in this range), though they may be weak or diffuse for disordered or weakly scattering materials. We can reconstruct the orientation of the π-π stacking, the degree of π-π stacking in the sample, and the domain size of the aligned regions. This Account summarizes illumination conditions and experimental parameters for 4D-STEM experiments with the goal of producing images of structural features for materials that are beam-sensitive. We will discuss experimental parameters including sample cooling, probe size and shape, fluence, and cameras. 4D-STEM has been applied to a variety of materials, not only as an advanced technique for model systems, but as a technique for the beginning microscopist to answer materials science questions. It is noteworthy that the experimental data acquisition does not require an aberration-corrected TEM but can be produced on a variety of instruments with the right attention to experimental parameters.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Improved uranium isotopic ratio determinations for the liquid sampling-atmospheric pressure glow discharge orbitrap mass spectrometer by use of moving average processing

The liquid sampling-atmospheric pressure glow discharge (LS-APGD) is a versatile combined atomic and molecular (CAM) ionization source capable of ionizing elemental species, small polar compounds, low-polarity polycyclic aromatic hydrocarbons, and proteins. While the LS-APGD has been proven capable of determining the 235U/238U isotope ratio in enriched and natural uranium, recent efforts have strived to reduce the analysis time of individual measurements by employing higher-order data processing techniques, specifically, moving average methods. Additionally, the use of a moving average (of data windows of various widths) improves the precision of the ratio measurements and reduces the number of scans needed to be collected to generate high-precision results. Additionally, use of the moving average minimizes the quantity of sample that needs to be analyzed while reducing the measurement time. These reductions have allowed isotope ratio (IR) determinations to be made using injections instead of direct infusion of the analyte. For example, employing a 40-point window width in the moving average to direct infusion data reduced the percent relative standard deviation (% RSD) of the 235U/238U values from 3.4% to 0.5%. For the injection of a 100 μL aliquot, the % RSD was reduced from 5.3% to 0.7%.

74 ATOMIC AND MOLECULAR PHYSICS↗

The use of synchrotron X-ray fluorescent imaging to study distribution and content of elements in chemically fixed single cells: a case study using mouse pancreatic beta-cells

Synchrotron X-ray fluorescence microscopy (SXRF) presents a valuable opportunity to study the metallome of single cells because it simultaneously provides high-resolution subcellular distribution and quantitative cellular content of multiple elements. Different sample preparation techniques have been used to preserve cells for observations with SXRF, with a goal to maintain fidelity of the cellular metallome. In this case study, mouse pancreatic beta-cells have been preserved with optimized chemical fixation. We show that cell-to-cell variability is normal in the metallome of beta-cells due to heterogeneity and should be considered when interpreting SXRF data. Additionally, we determined the impact of several immunofluorescence (IF) protocols on metal distribution and quantification in chemically fixed beta-cells and found that the metallome of beta-cells was not well preserved for quantitative analysis. However, zinc and iron qualitative analysis could be performed after IF with certain limitations. To help minimize metal loss using samples that require IF, we describe a novel IF protocol that can be used with chemically fixed cells after the completion of SXRF.

59 BASIC BIOLOGICAL SCIENCES↗

Characterization Techniques for TRU Waste from the Analytical Laboratory Hot Cells at Idaho National Laboratory - 19610

Since the first reactor went hot in 1942, there has been a never ending desire to improve the nuclear reactor and the fuel that it burns. The Idaho National Laboratory has been a key player in reactor and fuel development. As more research projects begin, the spectrum of waste parameters grows. Over the years, the Analytical laboratory (AL) at the INL Materials and Fuels Complex (MFC) has supported a large range of various research projects. Each project brings its own challenge and analytical technique that, in turn, yields its own unique waste parameters. The AL Hot Cells at INL consist of 6 small cells that can support around 12 different fuel research projects at a time along with infrastructure and environmental samples. Each different project yields different levels of transuranic (TRU) material, RCRA constituents, dose, and contamination levels. The waste parameters from each project dictate a path forward for the waste as Low-Level Waste (LLW), Contact Handled TRU (CH-TRU), Mixed Contact Handled TRU (M-CH-TRU), Remote Handled TRU (RH-TRU), or Mixed Remote Handled TRU (M-RHTRU). With visual examination techniques and process knowledge as an aid, there have been waste handling methods developed that allow debris and sample material to be segregated. Unique characterization mechanisms have been applied for each debris and sample material that are generally more accurate than smear and surface contamination data. For debris found in the Hot Cells, analytical data is gathered and conservatively summarized for each fuel type and research method. This consists of data from Quadrupole Inductively Coupled Plasma Mass Spectrometry (Q-ICP-MS), Gamma Spectroscopy, and some data verification through Thermal Ionization Mass Spectrometry (TIMS) and Multi-Collector Inductively Coupled Plasma Mass Spectrometry (MC-ICP-MS). This data gives a range of TRU isotope concentrations. Fuel age is taken into account to determine the dominant TRU activity isotopes. Cesium concentrations are also gathered. Each parameter/fuel type then ties a measured Cesium number to TRU content based on historical analytical data. Debris in the hot cells is segregated by project and packaged in individual 2 gallon metal paint cans. Each can is counted by gamma spectroscopy in a calculated and measured geometry. Using process knowledge to determine the fuel or project type, newly counted cesium numbers can be applied to the historic analytical data and TRU content can be estimated. The TRU content allows waste debris to be segregated between CH-TRU and RH-TRU. Packaging techniques can allow for the minimization of RHTRU waste. Sample material received into the AL must be dissolved into a liquid matrix in order to be analyzed in most cases. When analysis is complete, these liquids go through a consolidation, complexation, neutralization, and solidification process where real time analytical data can be used to calculate TRU content and RCRA constitutes. These calculations allow for no further analytical data to be gathered. The waste matrix is considered stable and acceptable by all Acceptable Knowledge (AK) documents. The unique techniques used in characterizing and handling the Analytical Laboratories Hot Cell waste can be applied to various situations and various laboratories. They allow for more accurate data for waste constituents and also for the minimization of RH-TRU waste. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Thermal Flux Maximization from a DD Neutron Generator

The University of Sharjah recently acquired a model DD-109.4M neutron generator from Adelphi Technology. The generator is moderated and has three neutron ports which are capable of providing fast and thermal neutrons. The neutron ports are plugged with polyethylene layers of different thickness in order to control the neutron flux at different regions in the port. Neutron Activation Analysis (NAA) is an important analysis technique to determine the amounts of isotopes in a sample at different concentrations. For many isotopes the ability to precisely determine their concentrations is enhanced by utilizing thermal neutrons in the activation process; where the capture cross section is greatest. It is thus important to subject the sample to the maximum thermal flux in order to minimize the time required to activate the sample and consequently extend the lifetime of the neutron generator. A detailed MCNP model of the neutron generator has been developed for the purpose of determining the moderator thickness required to maximize the thermal neutron flux in the neutron port. The maximization of the neutron flux must therefore take into account both the forward and backscattered neutrons reaching the sample. Also provided in this work is a mapping of the thermal flux at different moderator thicknesses in order to study the variation of the flux over the area of the sample. The developed model will be used as the basis for optimizing experiments and predicting their results. A study was performed to determine the moderator thickness needed to maximize the thermal neutron flux that can be obtained from a DD neutron generator. This has a significant role in the efficient utilization of the neutron generator. The maximum thermal neutron flux was found at approximately a 3.2 cm moderator thickness. The thermal neutron flux is resulting from both the directly moderated neutrons and the backscattered neutrons from the surrounding polyethylene. The results obtained in this work will be verified experimentally by irradiating samples at different moderator thickness and performing a neutron activation analysis for these samples. (authors)

07 ISOTOPE AND RADIATION SOURCES↗