Search NASA⌕ Search

SEARCH · Search NASA

Results for “sample thickness”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Space fabrication demonstration system

The development effort on the composite beam cap fabricator was completed within cost and close to abbreviated goals. The design and analysis of flight weight primary and secondary beam builder structures proceeded satisfactorily but remains curtailed until further funding is made available to complete the work. The induction fastening effort remains within cost and schedule constraints. Tests of the LARC prototype induction welder is continuing in an instrumented test stand comprised of a Dumore drill press (air over oil feed for variable applied loads) and a dynamometer to measure actual welding loads. Continued testing shows that the interface screening must be well impregnated with resin to ensure proper flow when bonding graphite-acrylic lap shear samples. Specimens prepared from 0.030 inch thick graphite-polyethersulfone are also available for future induction fastening evaluation.

Source record↗

Structurally stable, thin silicon solar cells

A fabrication process for structurally stable thin solar cell wafers that produce good power output after irradiation is described. The fabrication process is as follows. A 6 mil, circular wafer is oxidized on both sides. One side is then patterned with a rectangular array of holes in the oxide that are nominally 75 mils square and separated by 2 mil spacings. Wells are then etched into the silicon with KOH to a depth of 4 mils, leaving a 2 mil, unetched thickness. Two areas on the surface are left unetched to provide pads for bonding or testing. All oxide is then removed and the rest of the processing is normal; the unetched face is used as the illuminated face. When all other processing is complete, a 2 X 2 cm cell is sawed from the starting wafer leaving a border that is approximately 10 mils wide. The effective thickness, determined by weighing an unmetallized sample, of such a cell is about 2.4 mil.

Arndt, R. A.↗

Determination of the optical thickness of clouds from reflected solar radiation measurements

A procedure is presented for inferring cloud optical thickness from reflected solar radiation measurements. Asymptotic expressions are defined for the reflection and transmission functions of optically thick atmospheres, noting that the reflection function sensitivity to cloud optical thickness is highest with minimal surface albedo. Attention is also given to the dependence of the optical thickness on the cloud asymmetry factor. Sample results are provided from several high altitude aircraft flights to determine the reflection function of clouds.

King, M. D.↗

Increased effective barrier heights in Schottky diodes by molecular-beam epitaxy of CoSi2 and Ga-doped Si on Si(111)

Increasing the effective Schottky-barrier height of epitaxial CoSi2/Si(111) diodes by the use of thin, highly doped Si layers in close proximity to the metal-semiconductor interface has been studied. Intrinsic Si, Si doped by coevaporation of Ga, and epitaxial CoSi2 layers have all been grown in the same molecular-beam epitaxy system. Current-voltage and photoresponse characterization yield barrier heights ranging from 0.61 eV for a sample with no p(+) layer to 0.89 eV for a sample with a 20-nm-thick p(+) layer. These results are compared to theoretical values based on a one-dimensional solution of Poisson's equation under the depletion approximation.

Fathauer, R. W.↗

Antarctic weathering of the CK chondrites EET90004, 90007, and 90022: Nickel and sulfur mobility

CK chondrites are a relatively new class of carbonaceous chondrite that have been described in the literature. Most meteorites that comprise the CK group are restricted to Antarctic finds; therefore terrestrial weathering processes can influence the geochemical records contained within these chondrites. The paired CK chondrites EET90004, 90007, and 90022 share not only a common heritage but similar weathering histories since all three meteorites were found on Antarctic ice covered with thick evaporative coatings. Additional material has grown on these samples during curation at the Antarctic Meteorite Lab at JSC, NASA. At present, efflorescence up to a millimeter thick coats the surface of EET90004 and 90022, with less material coating EET90007. The chemistry, mineralogy, and isotopic composition of efflorescence on EET90004 and 90022, described here, provide valuable information regarding the fate of meteoritic components in the Antarctic environment.

Romanek, C. S.↗

RF Performance of Membrane Aperture Shells

This paper provides an overview of recent results establishing the suitability of Membrane Aperture Shell Technology (MAST) for Radio Frequency (RF) applications. These single surface shells are capable of maintaining their figure with no preload or pressurization and minimal boundary support, yet can be compactly roll stowed and passively self deploy. As such, they are a promising technology for enabling a future generation of RF apertures. In this paper, we review recent experimental and numerical results quantifying suitable RF performance. It is shown that candidate materials possess metallic coatings with sufficiently low surface roughness and that these materials can be efficiently fabricated into RF relevant doubly curved shapes. A numerical justification for using a reflectivity metric, as opposed to the more standard RF designer metric of skin depth, is presented and the resulting ability to use relatively thin coating thickness is experimentally validated with material sample tests. The validity of these independent film sample measurements are then confirmed through experimental results measuring RF performance for reasonable sized doubly curved apertures. Currently available best results are 22 dBi gain at 3 GHz (S-Band) for a 0.5m aperture tested in prime focus mode, 28dBi gain for the same antenna in the C-Band (4 to 6 GHz), and 36.8dBi for a smaller 0.25m antenna tested at 32 GHz in the Ka-Band. RF range test results for a segmented aperture (one possible scaling approach) are shown as well. Measured antenna system actual efficiencies (relative to the unachievable) ideal for these on axis tests are generally quite good, typically ranging from 50 to 90%.

Flint, Eirc M.↗

An Efficient Monte Carlo Method for Modeling Radiative Transfer in Protoplanetary Disks

Monte Carlo methods have been shown to be effective and versatile in modeling radiative transfer processes to calculate model temperature profiles for protoplanetary disks. Temperatures profiles are important for connecting physical structure to observation and for understanding the conditions for planet formation and migration. However, certain areas of the disk such as the optically thick disk interior are under-sampled, or are of particular interest such as the snow line (where water vapor condenses into ice) and the area surrounding a protoplanet. To improve the sampling, photon packets can be preferentially scattered and reemitted toward the preferred locations at the cost of weighting packet energies to conserve the average energy flux. Here I report on the weighting schemes developed, how they can be applied to various models, and how they affect simulation mechanics and results. We find that improvements in sampling do not always imply similar improvements in temperature accuracies and calculation speeds.

radiative transfer↗

A sensitive 10-micron search for emission arising from circumstellar dust associated with solar-type pre-main-sequence stars

The presence and evolutionary timescales of circumstellar disks surrounding solar-type premain-sequence stars are studied using excess IR radiation above photospheric levels. The analysis is based on optical photometry, published near-IR fluxes, IRAS fluxes, and 10-micron flux measurements of 20 stars in Taurus-Auriga obtained with the NASA IR telescope facility. About half of the stars with ages less than 3 Myr show excess 2.2 and 10 micron emission, consistent with emission from optically thick disks extending inward to the stellar surface. At ages of about 10 Myr, less than 10 percent of the sample stars show evidence of dust emission from optically thick disks. It is concluded that the timescale over which disks survive as IR-luminous, optically thick structures is less than 10 Myr. Also, evidence for inner holes in premain-sequence stars surrounded by optically thick disks is discussed.

Skrutskie, M. F.↗

Handling Heavenly Jewels - 35 Years of Antarctic Meteorite Processing at Johnson Space Center

The ANSMET program began in 1976, and since that time more than 18,000 meteorites have been processed in the Meteorite Processing Lab at Johnson Space Center in Houston, TX[1]. The meteorites are collected and returned to JSC on a freezer truck and remain frozen until they are initially processed. Initial Processing of Meteorites: Initial processing involves drying the meteorites in a nitrogen glove box for 24 to 48 hours, photographing, measuring, weighing and writing a description of the interior and exterior. The meteorite is broken and a representative sample is sent to the Smithsonian Institution for classification. Newsletter & Requests: Once initial processing has been complete and the meteorites have been classified, the information is published in the Antarctic Meteorite Newsletter[2,3]. The newsletter is published twice yearly and is sent electronically to researchers around the world and is also available on line. Researchers are asked to fill out a request form and submit it to the Meteorite Working Group secretary. All sample requests will be reviewed by either the meteorite curator or the Meteorite Working Group de-pending on the type of meteorite and the research being conducted. Processing for Sample Requests: In the meteorite processing lab, meteorite samples are prepared several different ways. Most samples are prepared as chips obtained by use of stainless steel chisels in a chipping bowl or rock splitter. In special situations where a researcher needs a slab the meteorite samples can be bandsawed in a dry nitrogen glove box with a diamond blade, no liquids are ever introduced into the cabinet. The last type of sample preparation is thin/thick sections. The meteorite thin section lab at JSC can prepare standard 30-micron thin sections, thick sections of variable thickness (100 to 200 microns), or demountable sections using superglue. Information for researchers: It is important that re-searchers fill the sample request form completely, in order to make sure the meteorite is processed correctly[4]. Re-searchers should list any special requirements on the form, i.e. packaging of samples (poly vs. stainless), thick sections and thickness needed, superglue needed, interior chips, exterior chips, fusion crust, contamination issues, all concerns should be listed so processing can be done accurately and any concerns the researcher has can be addressed be-fore the meteorites are broken.

Satterwhite, C. E.↗

Magnetic Properties of Fe-49Co-2V Alloy and Pure Fe at Room and Elevated Temperatures

The National Aeronautics and Space Administration (NASA) has a need for soft magnetic materials for fission power and ion propulsion systems. In this work the magnetic properties of the soft magnetic materials Hiperco 50 (Fe-49wt%Cr-2V) and CMI-C (commercially pure magnetic iron) were examined at various temperatures up to 600 C. Toroidal Hiperco 50 samples were made from stacks of 0.35 mm thick sheet, toroidal CMI-C specimens were machined out of solid bar stock, and both were heat treated prior to testing. The magnetic properties of a Hiperco 50 sample were measured at various temperatures up to 600 C and then again after returning to room temperature; the magnetic properties of CMI-C were tested at temperatures up to 400 C. For Hiperco 50 coercivity decreased as temperature increased, and remained low upon returning to room temperature; maximum permeability improved (increased) with increasing temperature and was dramatically improved upon returning to room temperature; remanence was not significantly affected by temperature; flux density at H = 0.1 kA/m increased slightly with increasing temperature, and was about 20% higher upon returning to room temperature; flux density at H = 0.5 kA/m was insensitive to temperature. It appears that the properties of Hiperco 50 improved with increasing temperature due to grain growth. There was no significant magnetic property difference between annealed and aged CMI-C iron material; permeability tended to decrease with increasing temperature; the approximate decline in the permeability at 400 C compared to room temperature was 30%; saturation flux density, B(sub S), was approximately equal for all temperatures below 400 C; B(sub S) was lower at 400 C.

De Groh, Henry C., III↗

Miniature Blimps for Surveillance and Collection of Samples

Miniature blimps are under development as robots for use in exploring the thick, cold, nitrogen atmosphere of Saturn's moon, Titan. Similar blimps can also be used for surveillance and collection of biochemical samples in buildings, caves, subways, and other, similar structures on Earth. The widely perceived need for means to thwart attacks on buildings and to mitigate the effects of such attacks has prompted consideration of the use of robots. Relative to rover-type (wheeled) robots that have been considered for such uses, miniature blimps offer the advantage of ability to move through the air in any direction and, hence, to perform tasks that are difficult or impossible for wheeled robots, including climbing stairs and looking through windows. In addition, miniature blimps are expected to have greater range and to cost less, relative to wheeled robots.

Jones, Jack↗

Corrosion Detection in Airframes Using a New Flux-Focusing Eddy Current Probe

A new flux-focusing eddy current probe was recently developed at NASA Langley Research Center. The new probe is similar in design to a reflection type eddy current probe, but is unique in that it does not require the use of an impedance bridge for balancing. The device monitors the RMS output voltage of a pickup coil and, as a result, is easier to operate and interpret than traditional eddy current instruments. The unique design feature of the probe is a ferromagnetic cylinder, typically 1020 steel, which separates a concentrically positioned drive and pickup coil. The increased permeability of the steel causes the magnetic flux produced by the drive coil to be focused in a ring around the pickup coil. At high frequencies the eddy currents induced in both the sample and the cylinder allow little or no flux to link with the pickup coil. This results in a self-nulling condition which has been shown to be useful for the unambiguous detection of cracks in conducting materials. As the frequency is lowered the flux produced by the drive coil begins to link with the pickup coil causing an output which, among other things, is proportional to the thickness of the test specimen. This enables highly accurate measurements of the thickness of conducting materials and helps to facilitate the monitoring of thickness variations in a conducting structure such as an aircraft fuselage. Under ideal laboratory conditions the probe can sense thickness changes on the order of 1% as illustrated. However, this is highly dependent upon the thickness, and the geometric complexity of the sample being tested and for practical problems the sensitivity is usually much less. In this presentation we highlight some of the advantages and limitations in using the probe to inspect aircraft panels for corrosion and other types of material nonuniformities. In particular, we present preliminary results which illustrate the probes capabilities for detecting first and second layer corrosion in aircraft panels which may contain air gaps between the layers. Since the probe utilized eddy currents its corrosion detection capabilities are similar to convectional eddy current techniques, but the new probe is much easier to use.

Fulton, James P.↗

Superconductivity devices: Commercial use of space

High T sub C superconducting thick film were prepared by a screen printing process. Y-based (YBa2Cu3O(7-x) superconducting thick film were printed on 211/Al2O3, SNT/Al2O3, and YSZ substrates. Because of poor adhesion of the superconductor thick films to 211/Al2O3 and SNT/Al2O3 substrates, relatively low T sub C and J sub C values were obtained from the films printed on these substrates. Critical temperatures (T sub C) of YBa2Cu3O(7-x) thick films deposited on 211/Al2O3 and SNT/Al2O3 substrates were about 80 K. The critical current densities (J sub C) of these films were less than 2 A/sq cm. Higher T sub C and J sub C YBa2Cu3O(7-x) thick films were printed on YSZ substrates. A YBa2Cu3O(7-x) thick film with T sub C=86.4 and J sub C= 50.4 A/sq cm was prepared by printing the film on YSZ substrate and firing at 990 C for 10 minutes. Multiple-lead samples were also prepared on the YSZ substrates. The multiple-lead samples showed lower T sub C and/or J sub C values than those of the plain samples. The electrical properties of YBa2Cu3O(7-x) thick films were determined by the microstructures of the films. The YBa2Cu3O(7-x) thick films printed on the YSZ substrates, which had the best properties among the films printed on the three different kinds of substrates, had the highest density and the best particle interconnection. The YBa2Cu3O(7-x) thick films with preferred orientation in (001) direction were obtained on the YSZ substrates. Cracks, which retard the properties of the films, were found from the films deposited on the YSZ substrates. Currently, a MSZ (Magnesium Stabilized Zirconia) substrate, which had higher thermal expansion coefficient than the YSZ substrate, is used as substrate for the YBa2Cu3O(7-x) thick film in order to eliminate the cracks on the film. Bi-based superconductor thick films were printed on polycrystalline MgO and YSZ substrates. Interactions between BSCCO thick films and the YSZ substrates were observed. Various buffer layer materials were applied onto the substrates in order to avoid the interactions between the BSCCO thick films and the ZrO2-based substrates. So far, a BSCCO printed on MgO substrate with T Sub C=89K was obtained. The J sub C of the film was lower than 0.1 A/sq cm by reason of poor interconnectivity of the BSCCO particles.

Haertling, Gene↗

Solid Surface Combustion Experiment: Thick Fuel Results

The results of experiments for spread over polymethylmethacrylate, PMMA, samples in the microgravity environment of the Space Shuttle are described. The results are coupled with modelling in an effort to describe the physics of the spread process for thick fuels in a quiescent, microgravity environment and uncover differences between thin and thick fuels. A quenching phenomenon not present for thin fuels is delineated, namely the fact that for thick fuels the possibility exists that, absent an opposing flow of sufficient strength to press the flame close enough to the fuel surface to allow the heated layer in the solid to develop, the heated layer fails to become 'fully developed.' The result is that the flame slows, which in turn causes an increase in the relative radiative loss from the flame, leading eventually to extinction. This potential inability of a thick fuel to develop a steady spread rate is not present for a thin fuel because the heated layer is the fuel thickness, which reaches a uniform temperature across the thickness relatively rapidly.

Altenkirch, Robert A.↗

Positive Electrode Fabrication for Bi-polar Ni-h2 Cells

Bi-Polar nickel hydrogen design studies indicated a potential improvement in energy density and specific energy if positive electrodes could be manufactured in configurations of twice or more of the present normal thickness. Such electrodes would have to achieve similar active material loading, utilization, and cycle life to conventional 0.8mm I.P.U. nickel hydrogen electrodes. A capability for producing 1.0mm dry sinter and 1.5mm slurry sinter structures on production processes and equipment was demonstrated. The EPI/USAF electrochemical impregnation process proved capable of loading thick electrodes to 1.60 g/cubic centimeters void or higher. Sample electrodes incurred 2000 high rate stress cycles without significant structural or performance degradation. Formation regimes developed for thin plaque are not optimal for thick plaque and further investigation into electrode capacity build-up would seem warranted. Thick electrode technology development is continuing under other programs and shows promise of fulfilling the projected energy density and specific energy improvements.

Edgar, T. A.↗

Diversity in C-Xanes Spectra Obtained from Carbonaceous Solid Inclusions from Monahans Halite

Monahans meteorite (H5) contains fluid inclusion- bearing halite (NaCl) crystals [1]. Microthermometry and Raman spectroscopy showed that the fluid in the inclusions is an aqueous brine and they were trapped near 25degC [1]. Their continued presence in the halite grains requires that their incorporation into the H chondrite asteroid was post metamorphism [2]. Abundant solid inclusions are also present in the halites. The solid inclusions include abundant and widely variable organics [2]. Analyses by Raman microprobe, SEM/EDX, synchrotron X-ray diffraction and TEM reveal that these grains include macromolecular carbon similar in structure to CV3 chondrite matrix carbon, aliphatic carbon compounds, olivine (Fo99−59), high- and low-Ca pyroxene, feldspars, magnetite, sulfides, lepidocrocite, carbonates, diamond, apatite and possibly the zeolite phillipsite [3]. Here we report organic analyses of these carbonaceous residues in Monahans halite using C-, N-, and O- X-ray absorption near edge structure (XANES). Samples and Methods: Approximately 100 nm-thick sections were extracted with a focused ion beam (FIB) at JSC from solid inclusions from Monahans halite. The sections were analyzed using the scanning transmission X-ray microscope (STXM) on beamline 5.3.2.2 at the Advanced Light Source, Lawrence Berkeley National Laboratory for XANES spectroscopy. Results and Discussion: C-XANES spectra of the solid inclusions show micrometer-scale heterogeneity, indicating that the macromolecular carbon in the inclusions have complex chemical variations. C-XANES features include 284.7 eV assigned to aromatic C=C, 288.4-288.8 eV assigned to carboxyl, and 290.6 eV assigned to carbonate. The carbonyl features obtained by CXANES might have been caused by the FIB used in sample preparation. No specific N-XANES features are observed. The CXANES spectra obtained from several areas in the FIB sections include type 1&2 chondritic IOM like, type 3 chondritic IOM like, and none of the above. The natures of the macromolecular carbon in the solid inclusions observed by C-XANES are consistent with the previous studies showing that the carbonaceous solid inclusions have not originated from Monahans parent body [1-3], and have various origins, including various chondritic meteorite parent bodies as well as other unknown source(s).

Kebukawa, Y.↗

Compact piezoelectric resonance mass balance for sample verification and mass quantification and mixing.

There is a need for sample verification and mass quantification of rock, soil and/or ice obtained by sample acquisition mechanisms on extraterrestrial bodies. For many scientific instruments information about the mass of the sample would aid in the interpretation of the data and help prevent the portioning system from overloading instrument ports. Additionally, on a potential sample return mission it is likely that a sample confirmation or mass determination requirement would be implemented before the spacecraft would be commanded to return to Earth or Lunar orbit. In an effort to meet these potential requirements, a piezoelectric resonance balance is being developed to measure a frequency change proportional to the sample mass change. In previous work1 we developed a resonance balance which produced large non-linear frequency changes due to the addition of a large mass. In this study we have looked at a variety of resonator geometries in an effort to linearize the frequency shift with mass. In addition, we have investigated the use of oscillator/counter circuitry to track the frequency shift of the piezoelectric mass balance. In this new design the frequency shifts automatically when a mass is placed on the balance and the counter circuit calculates the frequency shift. This frequency is then converted to a mass using calibration tables determined previously. An additional feature we have implemented is the use of a high frequency thickness mode piezoelectric resonator to mix the sample and a reactant or solvent. This allows for measuring both sample and reagent prior to ingestion by the instrument. This paper will focus on the design requirements and how they are affected by the local gravity and acoustic properties of the sample. Designs which allow for easy loading and unloading of the balance will also be discussed.

Yahnker, Christopher R.↗