Search NASA⌕ Search

SEARCH · Search NASA

Results for “security operations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Modeling Data Flows with Network Calculus in Cyber-Physical Systems: Enabling Feature Analysis for Anomaly Detection Applications

The electric grid is becoming increasingly cyber-physical with the addition of smart technologies, new communication interfaces, and automated grid-support functions. Because of this, it is no longer sufficient to only study the physical system dynamics, but the cyber system must also be monitored as well to examine cyber-physical interactions and effects on the overall system. To address this gap for both operational and security needs, cyber-physical situational awareness is needed to monitor the system to detect any faults or malicious activity. Techniques and models to understand the physical system (the power system operation) exist, but methods to study the cyber system are needed, which can assist in understanding how the network traffic and changes to network conditions affect applications such as data analysis, intrusion detection systems (IDS), and anomaly detection. In this paper, we examine and develop models of data flows in communication networks of cyber-physical systems (CPSs) and explore how network calculus can be utilized to develop those models for CPSs, with a focus on anomaly and intrusion detection. This provides a foundation for methods to examine how changes to behavior in the CPS can be modeled and for investigating cyber effects in CPSs in anomaly detection applications.

97 MATHEMATICS AND COMPUTING↗

Cybersecurity Workforce Training for SMR Integration into Distribution Grids: A Competency Framework and Containerized Hands-On Lab for the SMR/DER/Microgrid Boundary

Small modular reactors (SMRs) and microreactors are entering the U.S. distribution grid as synchronous generation on feeders designed for loads and inverter-based distributed energy resources (DERs). No existing cybersecurity training program addresses this intersection of nuclear operations, DER management, and operational technology security. As subcontractor to Iowa State University on the CyDERMS Center, Argonne analyzed the relevant standards and training landscape, translated the resulting gaps into a twelve-objective competency framework across distribution-operator and graduate-analyst role tracks, and built a containerized training lab using a ∼400-bus composite grid model behind a realistically simulated Modbus TCP SCADA stack. The analysis isolates the balance-of-plant / energy-management-system (BOP/EMS) boundary as the critical jurisdictional seam where, as of March 2026, neither NRC nor NERC CIP cleanly claims cybersecurity responsibility for distribution-connected SMRs. The framework maps each objective across NIST CSF 2.0, ISA/IEC 62443, NIST NICE Task–Knowledge–Skill statements, and NRC RG 5.71 awareness-and-training controls. The training lab implements operator-recognition assessment scenarios spanning grid-side disturbances and telemetry-layer anomalies.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

MAVEN Information Security Governance, Risk Management, and Compliance (GRC): Lessons Learned

As the first interplanetary mission managed by the NASA Goddard Space Flight Center, the Mars Atmosphere and Volatile EvolutioN (MAVEN) had three IT security goals for its ground system: COMPLIANCE, (IT) RISK REDUCTION, and COST REDUCTION. In a multiorganizational environment in which government, industry and academia work together in support of the ground system and mission operations, information security governance, risk management, and compliance (GRC) becomes a challenge as each component of the ground system has and follows its own set of IT security requirements. These requirements are not necessarily the same or even similar to each other's, making the auditing of the ground system security a challenging feat. A combination of standards-based information security management based on the National Institute of Standards and Technology (NIST) Risk Management Framework (RMF), due diligence by the Mission's leadership, and effective collaboration among all elements of the ground system enabled MAVEN to successfully meet NASA's requirements for IT security, and therefore meet Federal Information Security Management Act (FISMA) mandate on the Agency. Throughout the implementation of GRC on MAVEN during the early stages of the mission development, the Project faced many challenges some of which have been identified in this paper. The purpose of this paper is to document these challenges, and provide a brief analysis of the lessons MAVEN learned. The historical information documented herein, derived from an internal pre-launch lessons learned analysis, can be used by current and future missions and organizations implementing and auditing GRC.

FISMA↗

System security in the space flight operations center

The Space Flight Operations Center is a networked system of workstation-class computers that will provide ground support for NASA's next generation of deep-space missions. The author recounts the development of the SFOC system security policy and discusses the various management and technology issues involved. Particular attention is given to risk assessment, security plan development, security implications of design requirements, automatic safeguards, and procedural safeguards.

Wagner, David A.↗

A Review of Behind-the-Meter Solar Generation Modeling and Forecasting

Solar photovoltaic systems largely integrated within the distribution grid are operated 'behind-the-meter' and power generation cannot be directly monitored by most utilities. The increasing penetration of behind-the-meter solar photovoltaic systems can deter efficient network and market operations due to variability and uncertainty in net load, which is exacerbated by limited visibility and the difficulty in analyzing the hosting capacity. Risk introduced by behind-the-meter solar contributions may hinder reliable and secure grid operations due to biased system monitoring and forecasts. Accurate behind-the-meter estimations, together with capacity and specification forecasts, thus play a key role in balancing supply and demand and this article reviews the pertinent literature, identifying key characteristics and predictive methods for efficient behind-the-meter solar photovoltaic generation. Forecasting is central to methods herein. The fundamental characteristics of behind-the-meter solar forecasting, including which methods are applicable for scenario-driven use cases, are driven by the metrics most useful for system-wide performance evaluation. To this aim, the literature is reviewed with a focus on forecasting applications for aggregate, regional behind-the-meter generation useful to bulk system and utility operations. As distinguished from net load forecasting, subtleties in these coincident tasks are explored before concluding with recommendations for current practice and future implementations.

behind-the-meter↗

Corporate Delivery of a Global Smart Buildings Program

Buildings account for about 40 percent of the total energy consumption in the U.S. and emit approximately one third of greenhouse gas emissions. But they also offer tremendous potential for achieving significant greenhouse gas reductions with the right savings strategies. With an increasing amount of data from buildings and advanced computational and analytical abilities, buildings can be made “smart” to optimize energy consumption and occupant comfort. Smart buildings are often characterized as having a high degree of data and system integration, connectivity and control, as well as the advanced use of data analytics. These “smarts” can enable up to 10–20% savings in a building, and help ensure that they persist over time. In 2009, Microsoft Corporation launched the Energy-Smart Buildings (ESB) program with a vision to improve building operations services, security and accessibility in services, and new tenant applications and services that improve productivity and optimize energy use. The ESB program focused on fault diagnostics, advanced analytics and new organizational processes and practices to support their operational integration. In addition to the ESB program, Microsoft undertook capital improvement projects that made effective use of a utility incentive program and lab consolidations over the same duration. The ESB program began with a pilot at Microsoft's Puget Sound campus that identified significant savings of up to 6–10% in the 13 pilot buildings. The success of the pilot led to a global deployment of the program. Between 2009 and 2015, there was a 23.7% reduction in annual electricity consumption (kWh) at the Puget Sound campus with 18.5% of that resulting from the ESB and lab consolidations. This article provides the results of research conducted to assess the best-practice strategies that Microsoft implemented to achieve these savings, including the fault diagnostic routines that are the foundation of the ESB program and organizational change management practices. It also presents the process that was adopted to scale the ESB program globally. We conclude with recommendations for how these successes can be generalized and replicated by other corporate enterprises.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Applications of fiber optics technology to the Space Station

Attention is given to the EM interference, data bandwidth requirement, zero gravity operation, data security, crew safety, and modular expansion considerations affecting the future design of fiber-optical systems for large manned orbiting stations. Emphasis is given to replacing current, solar cell array electric systems technology for onboard furnace operation, leading to the formulation of a concentrated solar energy (thermal IR) transport system that yields higher efficiency than photovoltaics, despite its lower weight, in conjunction with Brayton, Rankine or Stirling cycle engines. The optical characteristics of the optical fibers employed by this system are discussed.

Erwin, H. O.↗

The Use of Embedded Electric Grid Storage for Resilience, Operational Flexibility, and Cyber-Security

In recent years, bulk energy storage has been applied to electric power systems as an auxiliary device for the support of grid reliability via grid services. This approach is useful but only extracts value from storage on a marginal basis because grid services involve only a tiny fraction of the power flowing in a grid. While storage is flexible enough to perform many services, assessing its value on a stacked-services basis obscures its real value: storage is a buffer for electric energy flows. All of its capabilities stem from this one fundamental property. Limiting storage to use as an ancillary services device leaves this primary value untapped. The real value of storage is as a means to provide a key characteristic missing from power grids: the ability to absorb stresses with little or no loss of performance – the essence of resilience. Storage applied systematically throughout the grid can provide the missing “shock absorber” springiness that the grid is missing. To provide this value, storage must be incorporated into the grid as core infrastructure and must be deeply integrated into grid operations. Doing so will provide far-reaching benefits to users of electricity at all levels, including vastly increased system resilience, expanded system operational flexibility, support for critical lifeline functions during critical events, and even improved cyber security.

25 ENERGY STORAGE↗

Power Output and Air Requirements of a Two-stroke Cycle Engine for Aeronautical Use

This investigation was undertaken to determine the pressure and amount of air necessary for satisfactory high-speed, two-stroke cycle operation and thus permit the power requirements of the air pump or blower to be determined. Based on power output and air requirement here obtained the two-stroke cycle engine would seem to be favorable for aeronautical use. No attempts were made to secure satisfactory operation at idling speeds.

Paton, C R↗

The Potential and Beneficial Use of Weigh-In-Motion (WIM) Systems Integrated with Radio Frequency Identification (RFID) Systems for Characterizing Disposal of Waste Debris to Optimize the Waste Shipping Process

The Oak Ridge National Laboratory (ORNL) Weigh-In-Motion (WIM) system provides a portable and/or semi-portable means of accurately weighing vehicles and its cargo as each vehicle crosses the scales (while in motion), and determining (1) axle weights and (2) axle spacing for vehicles (for determination of Bridge Formula compliance), (3) total vehicle/cargo weight and (4) longitudinal center of gravity (for safety considerations). The WIM system can also weigh the above statically. Because of the automated nature of the WIM system, it eliminates the introduction of human errors caused by manual computations and data entry, adverse weather conditions, and stress. Individual vehicles can be weighed continuously at low speeds (approximately 3-10 mph) and at intervals of less than one minute. The ORNL WIM system operates and is integrated into the Bethel Jacobs Company Transportation Management and Information System (TMIS, a Radio-Frequency Identification [RFID] enabled information system). The integrated process is as follows: Truck Identification Number and Tare Weight are programmed into a RFID Tag. Handheld RFID devices interact with the RFID Tag, and Electronic Shipping Document is written to the RFID Tag. The RFID tag read by an RFID tower identifies the vehicle and its associated cargo, the specific manifest of radioactive debris for the uniquely identified vehicle. The weight of the cargo (in this case waste debris) is calculated from total vehicle weight information supplied from WIM to TMIS and is further processed into the Information System and kept for historical and archival purposes. The assembled data is the further process in downstream information systems where waste coordination activities at the Y-12 Environmental Management Waste Management Facility (EMWMF) are written to RFID Tag. All cycle time information is monitored by Transportation Operations and Security personnel.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Enhanced Power Grid Maintenance Planning and Quantum-Inspired Combinatorial Prospects

Efficient and reliable scheduling of maintenance for power generation and transmission infrastructure is essential for minimizing operational costs and ensuring grid stability. This paper introduces an integrated optimization framework for coordinated maintenance scheduling of generators and transmission lines under resource and reliability constraints. The model minimizes a composite cost function including maintenance and generation costs, as well as penalties for delayed maintenance, while satisfying N−1 security constraints, operational limits, and crew availability. Case studies on the IEEE 300-bus test system demonstrate the effectiveness of the proposed approach in producing feasible and cost-effective maintenance schedules. To address scalability and combinatorial complexity, the model is mapped into a Quadratic Unconstrained Binary Optimization (QUBO) problem, enabling exploration of solution approaches based on Quantum Imaginary Time Evolution (QITE). While the QUBO reformulation provides a foundation for future quantum-inspired optimization, this study focuses primarily on the development and demonstration of the classical optimization framework and illustrates the potential applicability of QITE in large-scale maintenance scheduling.

Chen, Yang [ORNL] (ORCID:0000000271693874)↗

Modeling distributed energy resource aggregations in security constrained unit commitment and economic dispatch

The Federal Energy Regulatory Commission (FERC) recently issued Order 2222, which requires all wholesale electricity markets in the US to allow distributed energy resources (DERs) to participate in the market as aggregated resources. These DER aggregations may be composed of many individual resources that are offered and dispatched by the market as a single entity. We present here a model of a distributed energy resource aggregator (DERA) that is scheduled by a market operator’s security constrained unit commitment (SCUC) and security constrained economic dispatch (SCED). The DERA model includes constraints for battery energy storage systems (BESSs), demand response resources (DRRs), and a simple distributed energy resource (DER). This paper describes a model for each resource type and presents two methods for the DERA to generate market offer curves: a profit-maximizing optimization to compute cost curves and a direct cost algorithm to determine dispatch costs for each resource and combine into cost curves. Once all participating DERAs are scheduled in SCUC/SCED, the model is then modified to dispatch individual DERs to maximize profit or minimize schedule deviation of the DERAs. A simulation of a representative day illustrates the DERA offers, the scheduled generation, and the DERA dispatch. Findings show the potential for unavoidable schedule deviations due to internal DER constraints and due to economic incentives to deviate from the SCUC/SCED schedules. This highlights the importance of DERA offer construction on market efficiency and system reliability. Novel aspects of our approach include: (1) We consider the asymmetry of price incentives impacting DERAs from the wholesale market compared to those impacting consumers from the retail market, as imposed by current regulations and laws. (2) We model aggregate consumer response through statistically parameterizable utility functions rather than a potentially impractical approach of modeling each individual consumer. (3) We show how to use the DERA operational dispatch model to create offers into the wholesale electricity market. (4) We show how DERAs may fail to meet their scheduled dispatch because the market offer format may not permit them to fully express their operational features such as intertemporal costs and constraints to the market.

aggregations↗

Initial Process and Expected Outcomes for Preliminary Identification of Routes to Yucca Mountain, Nevada

The Department of Energy's (DOE's) Office of Civilian Radioactive Waste Management (OCRWM) is responsible for developing and implementing a safe, secure and efficient transportation system to ship spent nuclear fuel (SNF) and high-level radioactive waste (HLW) from commercial and DOE sites to the proposed Yucca Mountain repository. The Office of Logistics Management (OLM) within OCRWM has begun to work with stakeholders to identify preliminary national suites of highway and rail routes that could be used for future shipments OLM is striving to develop a planning-basis set of routes that will support long-lead time logistical analyses (i.e., five or more years before shipment). The results will represent a starting point for discussions between DOE and corridor jurisdictions, and for shipping arrangements between DOE and carriers. This fulfills a recommendation of the National Academy of Sciences report on SNF and HLW transportation that 'DOE should identify and make public its suite of preferred highway and rail routes for transporting spent fuel and high level waste to a federal repository as soon as practicable to support State, Tribal and local planning, especially for emergency responder preparedness'. OLM encourages and supports participation of program stakeholders in a process to identify suites of national routes. The principal objective is to identify preliminary suites of national routes that reflect responsible consideration of the interests of a broad cross-section of stakeholders. This will facilitate transportation planning activities to help meet program goals, including providing an advanced planning framework for State and Tribal authorities; supporting a pilot program for providing funding under Section 180(c) of the Nuclear Waste Policy Act; allowing sufficient time for security and operational reviews in advance of shipments to Yucca Mountain; and supporting utility planning and readiness for transportation operations. Concepts for routing and routing criteria have been considered by several state regional groups supported by cooperative agreements with OLM. OCRWM is also working with other Federal agencies, transportation service providers and others involved in the transportation industry to ensure the criteria are consistent with operating practices and regulations. These coordination efforts will ensure the experience, knowledge, and expertise of those involved are considered in the process to identify the preliminary national suites of routes. This paper describes the current process and timeline for preliminary identification and analyses of routes. In conclusion: The path toward developing a safe, secure, and efficient transportation system for shipments of SNF and HLW to Yucca Mountain will require the participation of many interested parties. Real cooperative planning is sometimes challenging, and requires a commitment from all involved parties to act in good faith and to employ their best efforts in developing mutually beneficial solutions. Identifying routes to the proposed repository at Yucca Mountain, and engaging in planning and preparedness activities with affected jurisdictions and other stakeholders, will take time. OCRWM is committed to a cooperative approach that will ultimately enhance safety, security, efficiency and public confidence. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Methodology for Dynamic Security Risk Quantification and Optimal Resource Allocation of Security Assets

In this presentation we overview a methodology for dynamic security risk quantification and optimal resource allocation of security assets for high profile venues. This methodology is especially applicable to venues that require security screening operations such as mass transit (e.g., train or airport terminals), critical infrastructure protection (e.g., government buildings), and largescale public events (e.g., concerts or professional sports). The method starts by decomposing the three core components of risk -- threat, vulnerability, and consequence -- into their various subcomponents. For instance, vulnerability can be decomposed into availability, accessibility, organic security, and target hardness and each of these can be evaluated against the potential threats of interest for the given venue. Once evaluated, these subcomponents are rolled back up to compute the specific value for the vulnerability core risk component. Likewise, the same is done for consequence and threat, and then risk is computed as the product of these three components. A key aspect of our methodology is dynamically quantifying risk. That is, we incorporate the ability to uniquely allow the subcomponents and core components, and in turn, risk, to be quantified as a continuous function of time throughout the day, week, month, or year as appropriate.

Brigantic, Robert T.↗

SAFSTOR and License Renewal: Making Them Coexist

The Indian Point Energy Center is located on the eastern shore of the Hudson River in the town of Buchanan, New York. It lies approximately thirty miles north of New York City, and thus, holds the distinction of being the closest nuclear facility to a major metropolitan area. Units 1 and 2 were constructed and operated by Consolidated Edison and Unit 3 was owned and operated by the New York State Power Authority. All three units are now owned and operated by Entergy Nuclear- Northeast. Indian Point Unit 1 was powered by a pressurized water reactor which operated with an authorized maximum steady state power level of 615 thermal megawatts until October 31, 1974. On June 19, 1980, the Commission issued an order revoking authority to operate the facility. Although 244 spent fuel assemblies were successfully shipped offsite to a spent fuel reprocessing facility, 160 assemblies remain in the Unit 1 spent fuel pool awaiting relocation to dry cask storage. Units 2 and 3 are also pressurized water reactors which each produce slightly in excess of 1,000 MWe. Since 1974, Unit 1 has been maintained in a Safe Store Mode (SAFSTOR). For the purposes of this document, the term 'SAFSTOR' is intended to mean 'Custodial SAFSTOR' as described in section 2.4.3 of NUREG 0586 (Final Generic Environmental Impact Statement on Decommissioning of Nuclear Facilities (GEIS) as follows: 'Custodial SAFSTOR requires a minimum cleanup and decontamination effort initially, followed by a period of continuing care with the active protection systems (principally the ventilation system) kept in service throughout the storage period. Full-time onsite surveillance by operating and security forces is required to carry out radiation monitoring, to maintain the equipment, and to prevent accidental or deliberate intrusion into the facility and the subsequent exposure to radiation or the disposal of radioactivity beyond the confines of the facility'. The decision to enter SAFSTOR was based upon the immediate proximity of Unit 1 to the operating units and the fact that a number of Unit 1 systems are shared with Unit 2. Over the past few decades, additional Unit 1 space (primarily within the turbine building) has been cleaned out and is being used to support the operating Units. The original plan to maintain Unit 1 in a SAFSTOR condition until it could be safely dismantled along with Unit 2 at the end of the Unit 2 operating license in 2012, requires some level of re-thinking now that Units 2 and 3 are applying for renewal of their licenses with the desire to continue operation until the 2033 time frame. The remainder of this paper summarizes the inspections and assessments undertaken by Entergy to investigate and document the condition of Indian Point Unit 1 and the resulting steps taken to assure that it would not pose a threat to the license extension efforts being under taken by Units 2 and 3. In conclusion: the Entergy Indian Point management team has systematically undertaken an effort to ensure the Unit 1 SAFSTOR condition and has implemented programs and procedural controls which will assure that it will continue to be safely maintained and will not impact the continued safe operation of Units 2 and 3 during their license renewal period.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Automation of Vulnerability and Patch Management: Information Extraction, Association, and Optimization

Vulnerability and patch management is an integral part of a robust cybersecurity program, yet it grows increasingly complex due to the sheer amount of data that must be analyzed. Particularly in Operational Technology (OT) environments, analysis must be done manually because of the lack of automated solutions. Additionally, there are many steps in this process, from the initial discovery of the vulnerability to the implementation of its remediation, and each step in the process requires different data in order to be performed effectively. In this work, we provide approaches and strategies to assist operators in industrial or OT environments throughout the vulnerability management cycle. Security advisories provide key information about mitigation strategies, or actions that can be taken when a patch is unavailable or cannot be installed. Details of these strategies are not shared in public vulnerability databases and must be found manually. We approach this problem by designing a solution to automatically identify that information within vendor security advisories and retrieve it for operator use. We start with an approach that requires domain-specific knowledge of certain frequently-seen reference websites. Next, an approach that can work on an arbitrary website but relies on certain keywords. Finally, an approach that uses Natural Language Processing (NLP) methods and does not require specific knowledge or keywords. Each of these approaches is more general than its predecessor; we demonstrate high accuracy for all approaches Advisories also often contain details of affected products in non-standard or natural language formats. While this information can be easily understood when read by an operator, the non-standard format acts as a barrier to effective automation. We provide an approach for the first step in this process: identifying vendors in security advisories and mapping them to a standard framework for representing digital assets and software products. We evaluate five established string similarity algorithms, plus one of our own design that combines string similarity and information theory, on the task of mapping vendors to their corresponding entries in the Common Platform Enumeration (CPE) repository. Our results show that our proposed metric outperforms all others. Due to the constraints on time, finances, and personnel for organizations, Large Language Models (LLMs) may seem like attractive opportunities for security operators to speed up information gathering; however, it is still not clear whether LLMs can handle vulnerability management tasks well. To answer this question, we perform an empirical study of LLMs’ ability to provide consistent, accurate information about vulnerabilities in order to guide organizations in their adoption of LLMs. We observe poor performance for all models tested, suggesting that these models are not well-suited to the consistent retrieval of accurate vulnerability information. Finally, once vulnerabilities have been identified and any additional information has been obtained, operators must decide which remediation actions to implement based on their available resources. This already-complex problem becomes even more so when we consider that a vulnerability may have multiple avenues for remediation. We formulate this scenario as two knapsack problems and provide solutions, which we then compare against several existing strategies for vulnerability prioritization seen in real operational environments.

McClanahan, Kylie↗

Systems and methods for performing wireless financial transactions

A secure computing module (SCM) is configured for connection with a host device. The SCM includes a processor for performing secure processing operations, a host interface for coupling the processor to the host device, and a memory connected to the processor wherein the processor logically isolates at least some of the memory from access by the host device. The SCM also includes a proximate-field wireless communicator connected to the processor to communicate with another SCM associated with another host device. The SCM generates a secure digital signature for a financial transaction package and communicates the package and the signature to the other SCM using the proximate-field wireless communicator. Financial transactions are performed from person to person using the secure digital signature of each person's SCM and possibly message encryption. The digital signatures and transaction details are communicated to appropriate financial organizations to authenticate the transaction parties and complete the transaction.

97 MATHEMATICS AND COMPUTING↗