Search NASA⌕ Search

SEARCH · Search NASA

Results for “service systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Data-Driven Linear Parameter-Varying Modeling and Control of Flexible Loads for Grid Services

Flexible loads have great potential to improve the electric grid's flexibility and stability. To effectively control large ensembles of heterogeneous loads, reliable models thereof are required. This paper presents a data-driven modeling and control approach to manage flexible loads for providing grid services. We leverage a linear parameter-varying autoregressive moving average (LPV-ARMA) model to describe the aggregate load response, where the parameters in the model are used to capture external environmental impacts (e.g., weather). A gain-scheduling feedback controller is then developed to adapt to environmental variations. This data-driven approach can be easily applied to different types of loads in various environmental conditions. In addition to the ensemble controller, distributed load controllers are designed to deliver grid services, while maintaining the quality of service of inherent load tasks. We demonstrate the work on the IEEE 37-node distribution system for real-time power regulation services through control of thermostatically controlled loads.

61 RADIATION PROTECTION AND DOSIMETRY↗

Pest suppression potential varies across 10 bioenergy cropping systems

Abstract Top‐down suppression of herbivores is a fundamental ecological process and a critical service in agricultural landscapes. Adoption of bioenergy cropping systems is likely to become an increasingly important driver causing loss or gain of this service in coming decades. We measured natural pest suppression potential in ten model bioenergy crops in a long‐term experimental array by deploying plasticine sentinel caterpillar mimics, which record imprints from predator attacks. Cropping systems included three intensive annual row crop systems and a range of simple perennial monocultures and more complex polycultures. We compared attack rates across the ten cropping systems and assessed differences over time within a growing season and between the ground level and canopy. We found strong differences in attack rates across cropping systems, usually with more attacks in perennial crops than annuals. However, outcomes varied in space and time, both within and among cropping systems. Birds and small mammals were responsible for most, and sometimes all, attacks in annual crops and were most important early in the season. Chewing arthropod attacks increased over the course of the growing season and were responsible for most attack events in perennial systems. In late summer there were almost no attacks in annual crop canopies, while attack rates in perennial canopies at the same time were quite high and were carried out almost entirely by chewing arthropods. Our results underscore the lack of trophic complexity in annual bioenergy cropping systems relative to perennials. They also illustrate the dramatic changes in predator activity and predation intensity that occur both seasonally and between the ground and plant canopy. Policies and practices that increase the footprint of annual crops for bioenergy are likely to cause a deficit in pest suppression services at local and landscape scales.

60 APPLIED LIFE SCIENCES↗

Evaluation of Centralized Model-Based FLISR in a Lab Setup: Preprint

Utilities are installing advanced distribution management systems (ADMS) around the globe to improve the sensing and control of distribution systems. ADMS is becoming a critical component to improve the resiliency and reliability of distribution systems. These management systems host a multitude of applications that can be used to sense, control, and operate distribution systems. Fault location, isolation, and service restoration (FLISR) is one of the ADMS applications that is critical to improving resilience during fault conditions. FLISR applications use smart, controllable devices that are installed in the distribution system for FLISR operation. These controllable devices include distributed energy resources (DER) and reclosers. Evaluating such ADMS applications before installation in the field can help de-risk the field implementation and avoid costly failures in the field. This paper presents a background on experimental setup that are typically used to evaluate ADMS applications. This is followed by briefly presenting the setup used to evaluate the FLISR application in an off-the-shelf ADMS tool. Finally, results from the evaluation experiments are presented.

94 GMLC - Grid Modernization Laboratory Consortium↗

SD-WAN Evaluation Criteria for a Defense Information Systems Network Expeditionary Customer Edge

The Defense Information Systems Agency (DISA) has identified a service provision gap midway between the capacity and capability of a Defense Information Systems Network (DISN) transport Edge Points of Presence (POP) and U.S. Department of Defense (DoD) Enterprise Classified Travel Kit (DECTK). Some deployed force 100-user Tactical Operations Centers are in field locations far removed from the DISN transport core, in challenging environmental conditions with limitations on space, weight, power, and cooling for network equipment. As part of a multi-phase project, Pacific Northwest National Laboratory (PNNL) will gather and analyze requirements, design, develop, prototype, and test a miniaturized and ruggedized DISN Customer Edge POP scaled to support approximately 100 users in a field Tactical Operations Center. An Expeditionary Customer Edge (ECE) will be more suitable for field deployment than a DISN transport Edge POP, using ruggedized hardware and network function virtualization (NFV) to operate in challenging field environmental conditions, plus reduce weight, power, and cooling requirements. A key enabling technology for ECE is Software Defined Wide Area Networking (SD-WAN). This document provides: • A brief overview of SD-WAN use cases and how they apply to ECE • How SD-WAN technology compares to existing networks like DISN that use Optical Transport Networking (OTN) and Multiprotocol Label Switching (MPLS) • SD-WAN functional requirements relevant to ECE • A description of an ECE Virtual Prototype, including simulated wide area network paths and a DISN-representative implementation of MPLS, in Cisco Modeling Labs • Detailed network flow walkthroughs • Evaluation criteria based on ECE-relevant SD-WAN functional requirements Finally, an appendix provides an informal evaluation of Speedify—a commercial retail Virtual Private Network service—against the ECE SD-WAN evaluation criteria.

42 ENGINEERING↗

Online Monitoring of Medium Voltage Cable Systems with Spread Spectrum Time Domain and Frequency Domain Reflectometry

In-service failures of wave energy convertor (WEC) cable systems can have a significant cost and power availability impact. Close parallel research 2019 data showed > 1B£ and 9 Terra-Watt-Hours associated with global off-shore wind (OSW) cable failures (Strang-Moran 2020). OSW is a closely related technology but currently is significantly cheaper than WEC technology. For wave energy to compete, the problem of reliable cable transmission must be mitigated. This project develops isolation technology to allow online high frequency reflectometry testing of medium voltage cables (1 to 10 kV and higher) without arcing or damage to the test instrument. Online spread spectrum time domain reflectometry (SSTDR) testing has been established for low voltage cable systems in the aircraft and rail industry and the ability to detect and locate cable flaws of interest is well understood. Extending reflectometry testing to medium voltage systems could enable detection of cable damage before failures occur thereby allowing repair and replacement of damaged cable segments to be scheduled and managed. The seedling project succeeded to pass and receive high frequency SSTDR signals onto a cable up to 1 kV using a parallel trace isolation circuit board that can be connected onto the test cable. The approach used a novel circuit design for which an invention disclosure has been filed. A proposed sapling project would extend the technology toward the higher operating voltages used by WEC systems, thereby enabling online SSTDR cable monitoring. The goal of the seedling project was to extend the capability of the ARENA cable/motor test bed to address medium voltages and to develop a high pass filter isolation architecture to protect the reflectometry instrument from the low frequency (DC – 60 Hz) line voltage while allowing the high frequency diagnostic signal to pass to and from the test instrument to the live line. Initial efforts focused on passive LCR filter circuits to reduce 60 Hz levels below 10 volts from a 10 kV line while allowing the MHz high frequency chirps to pass onto the cables and for mV signals to be detected. We discovered that the parasitic loss behavior of real high voltage components precluded this approach from working. An alternate approach was adapted for the electric field to couple between two parallel traces on a printed circuit board much like a radio-frequency coupler. The challenge here was and is to have the parallel traces close enough to each other to effectively pass the high frequency chirp onto the live line and receive any reflected signal from any encountered impedance change along the cable. This reflected signal will be in the mV range. The traces however must be far enough apart to not allow arcing on the board. A design with 3 mm spacing was determined to allow the high frequency signal to pass onto the live line and receive the mV signal back into the instrument while reducing the 60 Hz voltage amplitude by >80 dB (more than a factor of 10,000) without allowing arcing from across the parallel traces. This was confirmed by simulation and test.

16 TIDAL AND WAVE POWER↗

Center for Alternative Synchronization and Timing (CAST) Technical Bulletin #007: Holdover Experiment #1

Stable and accurate timing forms the foundation of many modern essential services. While Global Navigation Satellite Systems (GNSS) provide a cheap way to achieve extremely accurate timing, these systems are vulnerable to interference and complete outages, forcing systems that rely on them into a state of holdover. Testing and characterizing holdover performance is therefore essential for ensuring that these modern services do not go down when GNSS-based timing is unavailable.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Center for Alternative Synchronization and Timing (CAST) Technical Bulletin #006: Holdover Experimental Summary

Stable and accurate timing forms the foundation of many modern essential services. While Global Navigation Satellite Systems (GNSS) provide a cheap way to achieve extremely accurate timing, these systems are vulnerable to interference and complete outages, forcing systems that rely on them into a state of holdover. Testing and characterizing holdover performance is therefore essential for ensuring that these modern services do not go down when GNSS-based timing is unavailable.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Transactive Campus Energy Systems: An R&D Testbed for Renewalables Integration, Efficiency, and Grid Services - CRADA 356 (Abstract)

Under this Cooperative Research and Development Agreement (CRADA), the project team consisting of Pacific Northwest National Laboratory (PNNL), acting on behalf of the U.S. Department of Energy, and the University of Washington (UW) and Washington State University (WSU), acting under the purview of the State of Washington’s Department of Commerce (the “industrial” partner), will connect the PNNL, UW, and WSU campuses to form a multi-campus test bed for transaction-based energy management – transactive – solutions (see sidebar). Building on the foundational transactive system established by the Pacific Northwest Smart Grid Demonstration (PNWSGD), it is proposing to construct the test bed as both a regional flexibility resource and as a platform for R&D on buildings/grid integration and information-based energy efficiency.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Accessing protected data by a high-performance computing cluster

A data protection system is provided that allows applications to access protected data in a way that restricts applications from outputting to unauthorized targets any unprotected data derived from the protected data and that ensures that the applications do not have access to a key that allows access to the unprotected data. The data protection system provides a policy server that may execute on a service node of a high performance computing system and a data encryption process that may execute on each compute node that is allocated to an application or batch job. The policy server maintains policies of entities specifying access control for protected data. The data encryption process generates a secure execution environment for an application process and interfaces with the policy server to retrieve keys for decrypting protected data in accordance with a policy, and it decrypts and provides the decrypted data to the application process.

Barnes, Peter↗

Statistical analysis and degradation pathway modeling of photovoltaic minimodules with varied packaging strategies

Degradation pathway models constructed using network structural equation modeling (netSEM) are used to study degradation modes and pathways active in photovoltaic (PV) system variants in exposure conditions of high humidity and temperature. This data-driven modeling technique enables the exploration of simultaneous pairwise and multiple regression relationships between variables in which several degradation modes are active in specific variants and exposure conditions. Durable and degrading variants are identified from the netSEM degradation mechanisms and pathways, along with potential ways to mitigate these pathways. A combination of domain knowledge and netSEM modeling shows that corrosion is the primary cause of the power loss in these glass/backsheet PV minimodules. We show successful implementation of netSEM to elucidate the relationships between variables in PV systems and predict a specific service lifetime. The results from pairwise relationships and multiple regression show consistency. This work presents a greater opportunity to be expanded to other materials systems.

electrical measurements↗

Continuum Model Development for Flow and Transport in Electrochemical Systems

Stanford University (Subcontractor) shall provide the services of qualified multiscale modelers to perform tasks that contribute to reaching the objectives of the LDRD project entitled Automated and Accelerated Continuum Model Development for Electrochemical Systems (Tracking number 24-ERD-051). These tasks relate to the development, deployment, and validation of multiscale models relevant to flow and transport in electrochemical systems.

42 ENGINEERING↗

Learning Sequential Distribution System Restoration via Graph-Reinforcement Learning

We report a distribution service restoration algorithm as a fundamental resilient paradigm for system operators provides an optimally coordinated, resilient solution to enhance the restoration performance. The restoration problem is formulated to coordinate distribution generators and controllable switches optimally. A model-based control scheme is usually designed to solve this problem, relying on a precise model and resulting in low scalability. To tackle these limitations, this work proposes a graph-reinforcement learning framework for the restoration problem. We link the power system topology with a graph convolutional network, which captures the complex mechanism of network restoration in power networks and understands the mutual interactions among controllable devices. Latent features over graphical power networks produced by graph convolutional layers are exploited to learn the control policy for network restoration using deep reinforcement learning. The solution scalability is guaranteed by modeling distributed generators as agents in a multi-agent environment and a proper pre-training paradigm. Comparative studies on IEEE 123-node and 8500-node test systems demonstrate the performance of the proposed solution.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Transactive Campus Energy Systems: An R&D Testbed for Renewables, Integration, Efficiency, and Grid Services (CRADA 356 / Amendment 1)

The Clean Energy and Transactive Campus (CETC) work described in this report was done as part of Amendment 1 to Campus Cooperative Research and Development Agreement (CRADA) 356, the Transactive Campus CRADA with the Washington State Department of Commerce (Commerce) between the U.S. Department of Energy’s (DOE’s), Pacific Northwest National Laboratory (PNNL) and the Commerce through the Clean Energy Fund (CEF). The original project team consisted of PNNL, the University of Washington (UW) and Washington State University (WSU), to connect the PNNL, UW, and WSU campuses to construct and operate the testbed as both a regional flexibility resource and as a platform for research and development (R&D) for buildings/grid integration. Building on the foundational transactive system established by the Pacific Northwest Smart Grid Demonstration (PNWSGD), the purpose of the project was to construct the testbed as both a regional flexibility resource and as a platform for R&D on buildings/grid integration and information-based energy efficiency. The testbed supports the integration of renewables and other regional needs, using the flexibility provided by building loads, energy storage, and smart inverters for batteries and photovoltaic (PV) solar systems, at four physical scales: multiple campuses, campus, microgrid and building.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Low-cost buffer storage for solar industrial steam applications

Motivation and importance: Many industrial process heat consumers operate throughout the day, and deep decarbonization with solar energy requires thermal energy storage. Thermal energy storage provides an additional operational benefit of firm delivery of steam – essential to reducing the risk of costly production interruptions. The group of process heat consumers that use steam for biofuels production for the California transportation fuels market is incentivized through the Low Carbon Fuel Standard (LCFS) to reduce their carbon intensity through the use of solar steam. Examples include ethanol and dimethyl ether production. The production of these and other fuels involves distillation driven by steam reboilers with steam pressures in the range 100-280 psig. These pressures can be delivered from the type of thermal energy storage that has been the focus of this project – a steam accumulator Sunvapor, Inc. (SVI) calls a “Bullet Steam Accumulator” or “BSA TM ”. Our project adds to the understanding of the design and integration of steam accumulators charged by solar thermal energy in a biofuels production facility, and similar facilities that consume process steam. The fuel application requires a demanding level of Process Safety Management not found in other steam applications. The type of steam accumulator SVI engineered and built integrates steam generation and storage in one vessel to reduce cost. Achieving a first of a kind permit to operate such a first device has also added to the understanding of the industrial application of such systems. Goals: The overall goal of the project has been to demonstrate the advantages that a “Bullet Steam Accumulator” (BSA™) can provide to solar steam integration with a manufacturing process. The industrial host has already been convinced of the potential of the available solar steam to lower than carbon intensity score. They have been interviewed for a number of publications such as that tout the advantages SVI’s system brings to their operations. Accomplishments: At the end of 2023 Sunvapor placed in service the country’s first industrial solar boiler with thermal energy storage. At the same time, this placement in service represents the first pilot commercial system to decarbonize biofuels production through the use of solar thermal energy. While the full technical effectiveness will be shown as soon as the customer’s plant is able to consume the available steam, the economic feasibility was indicated early in the project when the combination of costs and steam pricing required to meet investor expectations was determined. The project represents a reference pilot from which a full-scale commercial system may be expanded. This pilot is a necessary first step in providing the full potential benefits to the public, including decarbonization of transportation fuels. The decarbonization of the separation steps in fuels production may be the most cost-effective and nearest term solar fuel. Co-benefits include a reduction of air pollutants such as NOx and particulate matter, and job creation for the construction, operation and maintenance of industrial solar facilities.

14 SOLAR ENERGY↗

Study of Communication Boundaries of Primal-Dual Based Distributed Energy Resource Management Systems (DERMS)

As the coordination of distributed energy re-sources becomes more necessary to provide grid services through a distributed energy resource management system (DERMS), studying the communication requirements for suc-cessful real-world, low-cost implementation becomes increasingly important. Specifically, this paper studies the necessary communication time resolutions between the different system components for a primal-dual-based DERMS, a highly de-veloped DERMS framework. We design a metric to evaluate the functionality of a DERMS with respect to providing grid services. Using numerical simulations based on a real-world feeder in Colorado, we show that the upper bound on the time resolutions is on the order of minutes instead of the previously assumed order of seconds.

communication time resolution↗

Study of Communication Boundaries of Primal-Dual Based Distributed Energy Resource Management Systems (DERMS): Preprint

As the coordination of distributed energy resources (DERs) becomes more necessary to provide grid services through a distributed energy resources management system (DERMS), studying the communication requirements for successful real-world low-cost implementation becomes increasingly important. Specifically, this paper studies the needed communication time resolutions between the different system components for a primal-dual based DERMS which is a highly-developed DERMS framework. We design a metric to evaluate the functionality of a DERMS with respect to providing grid services. Using numerical simulations based on a real-world feeder in Colorado, we show that the upper bound on the time resolutions is on the order of minutes instead of the previously assumed order of seconds.

communication time resolution↗

Evaluation of H-Canyon Ventilation Exhaust Tunnel Inspection at the Savannah River Site - 20052

The Department of Energy (DOE) H-Canyon Facility at the Savannah River Site (SRS) is operated by Savannah River Nuclear Solutions (SRNS). The Facility Structural Integrity Program [1] provides a process to inspect, evaluate, and document the conditions of passive safety related structural systems and components, their degradation mechanisms and their impact on the safety envelope. The Structural Integrity Program performs periodic visual inspections to confirm the systems and components can perform their safety function and recommend corrective actions before the function is compromised. The H-Canyon Exhaust Tunnel is part of the H-Canyon Ventilation System and is periodically inspected under the Structural Integrity Program. The Tunnel performs a Safety Class passive design feature function that is available 100% of the time. The underground reinforced concrete Tunnel directs Canyon process air from the Canyon to the Sand Filter System. The radiological and chemical airborne activity coupled with the physical configuration of the tunnel precludes a manned entry into the tunnel to perform the inspection. Unlike active systems that can be subjected to physical testing to confirm capability, qualification calculations, including modeling, is performed to assess passive design feature capabilities relative to operational, accident and natural phenomena hazards events. Input for these calculations come from knowledge of field conditions, design drawings and conservative assumptions. The knowledge of field conditions comes from concrete and soil testing activities as well as inspection data. The use of cameras on crawlers to obtain inspection data and how that data is used in qualification calculations is the focus of this discussion. Remote Tunnel inspections have been performed using cameras on a stick, referred to as pole cameras, prior to Calendar Year 2003 (CY2003). Since CY2003, six camera equipped crawlers have been used. Crawlers have evolved and improved by incorporating lessons learned from the previous inspections. The latest 2019 crawler successfully traveled the entire length of the tunnel between the Canyon and Sand Filter System and captured images that were previously unseen, thus providing key visual data for the Structural Integrity Program report [2]. The inspection data serves as 1) input to qualification calculations, 2) validates current conditions remain bounded by qualification calculations, and 3) documents a record of change over time. This data is vital for the effective evaluation of the tunnel structure and aids with predicting the life cycle service life safety envelope to protect the public, environment, and facility worker. The goal of the 2019 deployment was to use a more robust vehicle to ensure travel over obstacles, perform the inspection with higher resolution cameras, and have the ability to elevate the cameras to view surfaces previously obscured by abandon-in-place ducts in the tunnel. The inspection information will serve to strengthen the input basis for qualification calculations, versus using excessive conservative calculation assumptions. This 2019 inspection was compared with previous crawler visual evidence to identify change over time to project remaining service life and confirm field conditions remain bounded by qualification calculations. The results of the 2019 Exhaust Tunnel inspection continue to improve and provide a firm basis to make sound engineering judgements regarding tunnel capability and approaches in projecting remaining service life with an aging system and component. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

funcX: Federated Function as a Service for Science

Here, funcX is a distributed function as a service (FaaS) platform that enables flexible, scalable, and high performance remote function execution. Unlike centralized FaaS systems, funcX decouples the cloud-hosted management functionality from the edge-hosted execution functionality. funcX's endpoint software can be deployed, by users or administrators, on arbitrary laptops, clouds, clusters, and supercomputers, in effect turning them into function serving systems. funcX's cloud-hosted service provides a single location for registering, sharing, and managing both functions and endpoints. It allows for transparent, secure, and reliable function execution across the federated ecosystem of endpoints-enabling users to route functions to endpoints based on specific needs. funcX uses containers (e.g., Docker, Singularity, and Shifter) to provide common execution environments across endpoints. funcX implements various container management strategies to execute functions with high performance and efficiency on diverse funcX endpoints. funcX also integrates with an in-memory data store and Globus for managing data that may span endpoints. We motivate the need for funcX, present our prototype design and implementation, and demonstrate, via experiments on two supercomputers, that funcX can scale to more than 130000 concurrent workers. We show that funcX's container warming-aware routing algorithm can reduce the completion time for 3,000 functions by up to 61% compared to a randomized algorithm and the in-memory data store can speed up data transfers by up to 3x compared to a shared file system.

97 MATHEMATICS AND COMPUTING↗