Search NASA⌕ Search

SEARCH · Search NASA

Results for “side load”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Method and system for spatially variable rate application of agricultural chemicals based on remotely sensed vegetation data

Remotely sensed spectral image data are used to develop a Vegetation Index file which represents spatial variations of actual crop vigor throughout a field that is under cultivation. The latter information is processed to place it in a format that can be used by farm personnel to correlate and calibrate it with actually observed crop conditions existing at control points within the field. Based on the results, farm personnel formulate a prescription request, which is forwarded via email or FTP to a central processing site, where the prescription is prepared. The latter is returned via email or FTP to on-side farm personnel, who can load it into a controller on a spray rig that directly applies inputs to the field at a spatially variable rate.

Hood, Kenneth Brown↗

Experimental Investigation and Fundamental Understanding of a Slowed UH-60A Rotor at High Advance Ratios

This paper describes and analyzes the measurements from a full-scale, slowed RPM, UH-60A rotor tested at the National Full-Scale Aerodynamics Complex 40- by 80- ft wind tunnel up to an advance ratio of 1.0. A comprehensive set of measurements, that includes performance, blade loads, hub loads and pressures/airloads makes this data set unique. The measurements reveal new and rich aeromechanical phenomena that are special to this exotic regime. These include reverse chord dynamic stall, retreating side impulse in pitch-link load, large inboard-outboard elastic twist differential, supersonic flow at low subsonic advancing tip Mach numbers, diminishing rotor forces yet dramatic build up of blade loads, and dramatic blade loads yet benign levels of vibratory hub loads. The objective of this research is the fundamental understanding of these unique aeromechanical phenomena. The intent is to provide useful knowledge for the design of high speed, high efficiency, slowed RPM rotors of the future and a challenging database for advanced analyses validation.

Datta, Anubhav↗

Multiple piece turbine rotor blade

A multiple piece turbine rotor blade with a shell having an airfoil shape and secured between a spar and a platform with the spar including a tip end piece. a snap ring fits around the spar and abuts against the spar tip end piece on a top side and abuts against a shell on the bottom side so that the centrifugal loads from the shell is passed through the snap ring and into the spar and not through a tip cap dovetail slot and projection structure.

33 ADVANCED PROPULSION SYSTEMS↗

Studies of Shear Band Velocity Using Spatially and Temporally Resolved Measurements of Strain During Quasistatic Compression of Bulk Metallic Glass

We have made measurements of the temporal and spatial features of the evolution of strain during the serrated flow of Pd{sub 40}Ni{sub 40}P{sub 20} bulk metallic glass tested under quasistatic, room temperature, uniaxial compression. Strain and load data were acquired at rates of up to 400 kHz using strain gages affixed to all four sides of the specimen and a piezoelectric load cell located near the specimen. Calculation of the displacement rate requires an assumption about the nature of the shear displacement. If one assumes that the entire shear plane displaces simultaneously, the displacement rate is approximately 0.002 m/s. If instead one assumes that the displacement occurs as a localized propagating front, the velocity of the front is approximately 2.8 m/s. In either case, the velocity is orders of magnitude less than the shear wave speed ({approx}2000 m/s). The significance of these measurements for estimates of heating in shear bands is discussed.

36 MATERIALS SCIENCE↗

Recent Developments in the Management of Cameco Corporation's Fuel Services Division Waste - 13144

Cameco Corporation is a world leader in uranium production. Headquartered in Saskatoon, Saskatchewan our operations provide 16% of the world uranium mine production and we have approximately 435 million pounds of proven and probable uranium reserves. Cameco mining operations are located in Saskatchewan, Wyoming, Nebraska and Kazakhstan. Cameco is also a major supplier of uranium processing services required to produce fuel for the generation of clean energy. These operations are based in Blind River, Cobourg and Port Hope, Ontario and are collectively referred to as the Fuel Services Division. The Fuel Services Division produces uranium trioxide from uranium ore concentrate at the Blind River Refinery. Cameco produces uranium hexafluoride and uranium dioxide at the Port Hope Conversion Facility. Cameco operates a fuel manufacturing facility in Port Hope, Ontario and a metal fabrication facility located in Cobourg, Ontario. The company manufactures fuel bundles utilized in the Candu reactors. Cameco's Fuel Services Division produces several types of low-level radioactively contaminated wastes. Internal processing capabilities at both the Blind River Refinery and Port Hope Conversion Facility are extensive and allow for the recycling of several types of waste. Notwithstanding these capabilities there are certain wastes that are not amenable to the internal processing capabilities and must be disposed of appropriately. Disposal options for low-level radioactively contaminated wastes in Canada are limited primarily due to cost considerations. In recent years, Cameco has started to ship marginally contaminated wastes (<500 ppm uranium) to the United States for disposal in an appropriate landfill. The landfill is owned by US Ecology Incorporated and is located near Grand View, Idaho 70 miles southeast of Boise in the Owyhee Desert. The facility treats and disposes hazardous waste, non-hazardous industrial waste and low-activity radioactive material. The site's arid climate, deep groundwater and favourable geology help ensure permanent waste isolation. Combined with a state of the art multi-layer landfill liner system, the Grand View facility represents an ideal choice to minimize environmental liability. Marginally contaminated wastes from operations within the Fuel Services Division are typically loaded into PacTec IP-2 rated Intermediary Bulk Containers and then transported by road to a nearby rail siding. The Intermediary Bulk Containers are then loaded in US Ecology owned gondola rail-cars. The gondolas are then transported via Canadian Pacific and Union Pacific railroads to the US Ecology Rail Transfer facility located in Mayfield, Idaho. The Intermediary Bulk Containers are unloaded into trucks for transport to the disposal facility located approximately 32 miles away. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Improved experimental and diagnostic techniques for dynamic tensile stress–strain measurement with a Kolsky tension bar

Kolsky tension bar experiments were improved for dynamic tensile stress–strain measurements with higher fidelity and minimal uncertainties. The difficulties associated with specimen gripping, relatively short gage section, and geometric discontinuity at the bar ends all compromise the accuracy of the traditional strain measurement method in a Kolsky tension bar experiment. Here in this study, an improved three-channel splitting-beam laser extensometer technique was developed to directly and independently track the displacement of the incident and transmission bar interfaces. By adopting a dual-channel configuration on the incident bar side, the resolution and measurement range of this laser extensometer were coordinated between the two channels to provide highly precise measurement at both small and large strains under high strain-rate loading condition. On the transmission bar side an amplified channel, similar to that used on the incident bar side, was adopted to measure the transmission bar displacement with high resolution. With this novel design, a maximum resolution of approximately 500 nm can be obtained for the bar displacement measurement, which corresponds to a strain of 0.0079% for a specimen with 6.35 mm gage length. To further improve the accuracy, a pair of lock nuts were used to tighten the tensile specimen to the bars in an effort not only to prevent the specimen from potential pre-torsional deformation and damage during installation, but also to provide better thread engagement between the specimen and the bar ends. As a demonstration of this technique, dynamic tensile stress–strain response of a 304L stainless steel was characterized with high resolution in both elastic and plastic deformations.

42 ENGINEERING↗

Estimating the value of jointly optimized electric power generation and end use: a study of ISO-scale load shaping applied to the residential building stock

A generation-to-load simulation estimated the impact, in terms of production costs and CO2 emissions, attributable to the joint optimization of electric power generation and flexible end uses to support increasing penetrations of renewable energy. Newly conceived, evaluated, and foundational in developing a U.S. National Standard was a transaction-less yet continuous demand response system based on a day-ahead optimum load shape (OLS) designed to encourage Internet-connected devices to autonomously and voluntarily explore options to favour lowest cost generators - without requiring two-way communications, personally identifiable information, or customer opt-in. Boundary conditions used for model calibration included historical weather, residential building stock construction attributes, home appliance and device empirical operating schedules, prototypical power distribution feeder models, thermal generator heat rates, startup and ramping constraints, and fuel costs. Results of an hourly-based annual case study of Texas indicate a 1/3 reduction in production costs and a 1/5 reduction in CO2 emissions are possible.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Experimental Observations of Damage States in Unnotched and Notched 3D Orthogonal Woven Coupons Loaded in Tension

This paper describes a series of unnotched and notched tensile tests on two 3D orthogonal woven architectures. Dog bone specimens were used for the unnotched tests, and open-hole specimens were used for the notched tests. For each architecture and test type, two specimens were loaded under monotonic displacement control to failure and two specimens were incrementally loaded to failure in five steps. X-ray computed tomography (CT) was used to characterize the woven architecture and defects on each specimen prior to testing. Digital image correlation (DIC) images were obtained from both sides of the specimen throughout the loading and unloading. Acoustic emission (AE) data were also continuously acquired throughout the loading. For the incremental tests, X-ray CT was used to document the damage progression after each load increment. The damage progression was analyzed based on the results from these three techniques. The results for both architectures and test specimens followed a pattern where matrix cracks formed at the surface perpendicular to the tensile load direction. New surface cracks formed continuously throughout the loading and cracks extended in depth and width. In general, fiber failure was not detected until specimen failure.

Wade C Jackson↗

Experimental Observations of Damage States in Unnotched and Notched 3D Orthogonal Woven Coupons Loaded in Tension

This paper describes a series of unnotched and notched tensile tests on two 3D orthogonal woven architectures loaded in the warp direction. Dogbone specimens were used for the unnotched tests, and open-hole specimens were used for the notched tests. For each architecture and test type, two specimens were loaded under monotonic displacement control to failure, and two specimens were incrementally loaded to failure in five steps. X-ray computed tomography (CT) was used to characterize the woven architecture and defects on each specimen prior to testing. Digital image correlation (DIC) images were obtained from both sides of the specimen throughout the loading and unloading. For the incremental tests, X-ray CT was used to document the damage progression after each load increment. The results for both architectures and test specimens followed a similar pattern where matrix cracks formed perpendicular to the load direction and were primarily located between the stacks of warp tows. Two-piece failure path always occurred perpendicular to the loading direction, along the through-thickness segments of the Z-tows. The combination of stress concentrations due to the specimen geometry, weave geometry, and cut tows created stress concentrations that appear to initiate failure.

Woven materials↗

Intelligent Energy Optimizer for Residential Buildings

Demand-side management in the buildings is essential for meeting grid flexibility needs in a highly renewable energy scenario. Appliance load monitoring helps decision making for demand-side management by providing the information on operation status/power consumption from different appliances in the buildings. Nonintrusive load monitoring (NILM) is an attractive option for appliance load monitoring using because it has lower cost for sensors and helps mitigate privacy concerns. In this study, the team used an event detection technique followed by two different methods for event classification. The results from k-means clustering showed that the events from a single appliance are often distributed in multiple clusters. Thus, the unsupervised method of NILM using k-means clustering used in this study was not very suitable for load disaggregation. The results from NILM showed that the F1 score for event classification was 0.77 for a heat pump water heater and very low for other appliances using the rule-based classification.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Load Power Agnostic 6.6 kW Wireless EV Charger with LCL Tuned Primary and Secondary Side Regulation

Wireless charging of electric vehicles (EVs) is going to play a major role in electrification of transportation. This paper proposes to utilize an LCL tuned primary and series tuned secondary with a secondary buck regulator to achieve power transfer control by secondary side control only. Analytical expressions for base (primary) coil current and transformer turns ratio N required to transfer the required power at a certain input voltage is calculated for a given coil set. The required parameters are calculated for a 6.6 kW wireless charging system with a matched circular coil set. The proposed control scheme and analysis were validated through Saber Sketch simulations and by a 6.6 kW laboratory prototype. Experimental results for different load power settings at voltages of 290 V, 340 V, and 370 V are presented.

Galigekere, Veda Prakash N.↗

Loads as a Resource: Frequency Responsive Demand

Demand-side frequency control can complement traditional generator controls to maintain the stability of large electric systems in the face of rising uncertainty and variability associated with renewable energy resources. This report presents a hierarchical frequency-based load control strategy that uses a supervisor to flexibly adjust control gains that a population of end-use loads respond to in a decentralized manner to help meet the NERC BAL-003-1 frequency response standard at both the area level and interconnection level. The load model is calibrated and used to model populations of frequency-responsive water heaters in a PowerWorld simulation of the U.S. Western Interconnection (WECC). The proposed design is implemented and demonstrated on physical water heaters in a laboratory setting. A significant fraction of the required frequency response in the WECC could be supplied by electric water heaters alone at penetration levels of less than 15%, while contributing to NERC requirements at the interconnection and area levels.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Detecting Tooth Damage in Geared Drive Trains

This paper describes a method that was developed to detect gear tooth damage that does not require a priori knowledge of the frequency characteristic of the fault. The basic idea of the method is that a few damaged teeth will cause transient load fluctuations unlike the normal tooth load fluctuations. The method attempts to measure the energy in the lower side bands of the modulated signal caused by the transient load fluctuations. The method monitors the energy in the frequency interval which excludes the frequency of the lowest dominant normal tooth load fluctuation and all frequencies above it. The method reacted significantly to the tooth fracture damage results documented in the Lewis data sets which were obtained from tests of the OH-58A transmission and tests of high contact ratio spiral bevel gears. The method detected gear tooth fractures in all four of the high contact ratio spiral bevel gear runs. Published results indicate other detection methods were only able to detect faults for three out of four runs.

Nachtsheim, Philip R.↗

Macromolecular Crowding Affects Voltage-Dependent Alamethicin Pore Formation in Lipid Bilayer Membranes

Macromolecular crowding is known to modulate chemical equilibria, reaction rates, and molecular binding events, both in aqueous solutions and at lipid bilayer membranes, natural barriers that enclose the crowded environments of cells and their subcellular compartments. Previous studies on the effects of macromolecular crowding in aqueous compartments on conduction through membranes have focused on single-channel ionic conduction through previously formed pores at thermodynamic equilibrium. Furthermore, the effects of macromolecular crowding on the mechanism of pore formation itself were studied using the droplet interface bilayer (DIB) technique with the voltage-dependent pore-forming peptide alamethicin (alm). Macromolecular crowding was varied using 8 kDa molecular weight polyethylene glycol (PEG8k) or 500 kDa dextran (DEX500k) in two aqueous droplets on both sides of the bilayer membrane. In general, voltage thresholds for pore formation in the presence of crowders in the droplets decreased compared to their values in the absence of crowders, due to excluded volume effects, water binding by PEG, and changes in the ordering of water molecules and hydrogen-bonding interactions involving the polar lipid headgroups. In addition, asymmetric crowder loading (e.g., PEG8k–DEX500k on either side of the membrane) resulted in transmembrane osmotic pressure gradients that either enhanced or degraded the ionic conduction through the pores.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effects of bearing deadbands on bearing loads and rotor stability

A generic model of a turbopump, simplified to bring out these effects is examined. This model demonstrates that bearing deadbands which are of the same order of magnitude or larger than the center-of-mass offset of a rotor due to mass imbalances cause significantly different dynamic behavior than would be expected of a linear, dynamical system. This fundamentally nonlinear behavior yields altered stability characteristics and altered bearing loading tendencies. It is shown that side forces can enhance system stability in the small, i.e., as long as the mass imbalance does not exceed some thresholds value or as long as no large, impulsive disturbances cause the motion to depart significantly from the region of stability. Limit cycles are investigated in this report and techniques for determining these limit cycles are developed. These limit cycles are the major source of bearing loading and appear in both synchronous and nonsynchronous forms. The synchronous limit cycles are driven by rotor imbalances. The nonsynchronous limit cycles (also called subsynchronous whirls) are self-excited and are the sources of instability.

Source record↗

Energy flexibility of residential buildings: A systematic review of characterization and quantification methods and applications

With building electric demand becoming increasingly dynamic, and a growing percentage of intermittent renewable power generation from solar photovoltaics and wind turbines, the power grid is facing increasing challenge to manage the real time balance between the supply and demand. With advancements in smart sensing and metering, smart appliances, electric vehicles, and energy storage technologies, demand side management of residential buildings can help the grid to improve stability by optimizing flexible loads. This paper reviews recent studies on residential building demand side management, with a focus on characterization and quantification of energy flexibility covering various types of flexible loads, metrics, methods, and applications. The reviewed studies showed four levels of applications: building level (45%), district or community level (29%), system level (19%), and building sector level (7%). Shifting loads is the dominant flexibility type in 60% of applications, followed by shedding (19%), generation (16%), and modulating (6%). Depending on the technology and application scope, flexible operations have a wide range of performance, with peak power reductions of 1%~65%, energy savings up to 60%, operational cost reduction of 1%~48%, and greenhouse gas emission reductions of up to29%. More than half (51%) of the studies employed control strategies to achieve flexibility; among those 72% used optimal controls, while 28% used rule-based controls. About 58% of the studies used mathematical formulation to quantify energy flexibility. Most studies were based on simulation, while less than 15% of the studies had measurements from experiments or field tests. The review reveals research opportunities to address significant gaps in the existing literature: (1) establishing a common definition and performance metrics for energy flexibility of buildings that are technology and application agnostic, (2) developing an ontology to standardize representation of flexibility resources for interoperability, (3) integrating occupant impacts into the quantification and optimization of energy flexibility, and (4) developing requirements and credits of energy flexibility in building energy codes and standards. Findings from the review can inform future research and development of energy flexible buildings which are essential to a reliable and resilient power grid.

Li, H↗

Sparse Control Synthesis for Uncertain Responsive Loads With Stochastic Stability Guarantees

In this report, recent studies have demonstrated the potential of flexible loads in providing frequency response services, predominantly due to their availability and cost-effectiveness. However, uncertainty and variability in various weather-related and end-use behavioral factors often impact the reliability of demand-side control performance. This work addresses this problem with the design of a demand-side control to achieve frequency response under load uncertainties. Our approach involves modeling the load uncertainties via stochastic processes that appear as both multiplicative and additive in the power system dynamics. Recently developed mean square exponential stability (MSES) results for continuous-time linear stochastic systems are applied to pose the control synthesis problem which results in an LMI-based optimization problem. Additional costs and constraints are added to the LMI-based controller synthesis to ensure MSES, improve closed-loop transient performance, maximize tolerable uncertainties, and promote sparsity in the controller. Additionally, the fundamental limitations between the tolerable uncertainties and control efforts while ensuring MSES are discussed. Further, the control synthesis problem for the case of the full-state measurement is generalized to the case of partial-state measurements. The proposed control synthesis is illustrated on an IEEE 39 bus system with rigorous studies to demonstrate the role of sparsity, closed-loop transient performance, tolerable uncertainties, and control efforts while ensuring MSES and achieving frequency response.

42 ENGINEERING↗

Finite Larmor radius effect on ion pickup at Venus

The interaction of the solar wind with Venus is influenced by the pickup of newly born exospheric oxygen ions by the convecting magnetosheath plasma. The flow and field configuration of the magnetosheath plasma, together with the large gyroradius of the pickup ions, cause mass loading to occur preferentially on one side of the magnetosheath. The observed hemispherical asymmetry in the magnetic field in the near-planet magnetosheath, attributed to this pickup process, is confirmed by direct observation of the picked-up planetary particles. Test particle calculations show that a current system created by ion pickup has the appropriate location and magnitude to account for the magnetic field asymmetry. The results indicate that a fluid treatment of the Venus mass-loading problem is not entirely appropriate; a hybrid or kinetic model is necessary to incorporate the finite Larmor radius of the pickup particles which produces the observed asymmetry.

Phillips, J. L.↗