Search NASA⌕ Search

SEARCH · Search NASA

Results for “simplified analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Cumulants and the moment algebra: Tools for analyzing weak measurements

Recently it has been shown that cumulants significantly simplify the analysis of multipartite weak measurements. Here we consider the mathematical structure that underlies this and find that it can be formulated in terms of what we call the moment algebra. Apart from resulting in simpler proofs, the flexibility of this structure allows generalizations of the original results to a number of weak measurement scenarios, including one where the weakly interacting pointers reach thermal equilibrium with the probed system.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Refraction-enhanced x-ray radiography for inertial confinement fusion and laser-produced plasma applications

We explore various laser-produced plasma and inertial confinement fusion applications of phase-contrast x-ray radiography, and we show how the main features of these enhancements can be considered from a geometrical optics perspective as refraction enhancements. This perspective simplifies the analysis and often permits simple analytical formulas to be derived that predict the enhancements. We explore a raytrace approach to various material interface applications, and we explore a more general example of refractive bending of x rays by an implosion plasma. We find that refraction-enhanced x-ray radiography of implosions may provide a means to quantify density differences across shock fronts as well as density variations caused by local heating due to high-Z dopants. We also point out that refractive bending by implosions plasmas can blur fine radiograph features and can also provide misleading contrast information on area-backlit pinhole imaging experiments unless its effects are taken into consideration.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A multichannel magnetic probe system for analysing magnetic fluctuations in helical axis plasmas

The need to understand the structure of magnetic fluctuations in H-1NF heliac [S. Hamberger et al., Fusion Technol. 17, 123 (1990)] plasmas has motivated the installation of a sixteen former, tri-axis helical magnetic probe Mirnov array (HMA). The new array complements two existing poloidal Mirnov arrays by providing polarisation information, higher frequency response, and improved toroidal resolution. The helical placement is ideal for helical axis plasmas because it positions the array as close as possible to the plasma in regions of varying degrees of favourable curvature in the magnetohydrodynamic sense, but almost constant magnetic angle. This makes phase variation with probe position near linear, greatly simplifying the analysis of the data. Several of the issues involved in the design, installation, data analysis, and calibration of this unique array are presented including probe coil design, frequency response measurements, mode number identification, orientation calculations, and mapping probe coil positions to magnetic coordinates. Details of specially designed digitally programmable pre-amplifiers, which allow gains and filters to be changed as part of the data acquisition initialisation sequence and stored with the probe signals, are also presented. The low shear heliac geometry [R. Jiménez-Gómez et al., Nucl. Fusion 51, 033001 (2011)], flexibility of the H-1NF heliac, and wealth of information provided by the HMA create a unique opportunity for detailed study of Alfvén eigenmodes, which could be a serious issue for future fusion reactors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Magnetic field structure influence on primary electron cusp losses for micro-scale discharges

An experimental effort was used to examine the primary electron loss behavior for micro-scale (≲3 cm diameter) discharges. The experiment uses an electron flood gun source and an axially aligned arrangement of ring-cusps to guide the electrons to a downstream point cusp. Measurements of the electron current collected at the point cusp show an unexpectedly complex loss pattern with azimuthally periodic structures. Additionally, in contrast to conventional theory for cusp losses, the overall radii of the measured collection areas are over an order of magnitude larger than the electron gyroradius. Comparing these results to Monte Carlo particle tracking simulations and a simplified analytical analysis shows that azimuthal asymmetries of the magnetic field far upstream of the collection surface can substantially affect the electron loss structure and overall loss area.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Transformation of potential energy surfaces for estimating isotopic shifts in anharmonic vibrational frequency calculations

A transformation of potential energy surfaces (PES) being represented by multi-mode expansions is introduced, which allows for the calculation of anharmonic vibrational spectra of any isotopologue from a single PES. This simplifies the analysis of infrared spectra due to significant CPU-time savings. An investigation of remaining deviations due to truncations and the so-called multi-level approximation is provided. The importance of vibrational-rotational couplings for small molecules is discussed in detail. In addition, an analysis is proposed, which provides information about the quality of the transformation prior to its execution. Benchmark calculations are provided for a set of small molecules.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Interpreting impedance spectra of organic photovoltaic cells—Extracting charge transit and recombination rates

Impedance spectroscopy has been widely used to extract the electron-hole recombination rate constant in organic photovoltaic cells (OPVs). This technique is typically performed on OPVs held at open-circuit. Under these conditions, the analysis is simplified with recombination as the only pathway for the decay of excess charge carriers; transit provides no net change in the charge density. In this work, we generalize the application and interpretation of impedance spectroscopy for bulk heterojunction OPVs at any operating voltage. This, in conjunction with reverse bias external quantum efficiency measurements, permits the extraction of both recombination and transit rate constants. Using this approach, the transit and recombination rate constants are determined for OPVs with a variety of electron donor-acceptor pairings and compositions. It is found that neither rate constant individually is sufficient to characterize the efficiency of charge collection in an OPV. It is demonstrated that a large recombination rate constant can be accompanied by a large transit rate constant, thus fast recombination is not necessarily detrimental to OPV performance. Extracting the transit and recombination rate constants permits a detailed understanding of how OPV architecture and processing conditions impact the transient behavior of charge carriers, elucidating the origin of optimum device configurations.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A Nth-order linear algorithm for extracting diffuse correlation spectroscopy blood flow indices in heterogeneous tissues

Conventional semi-infinite analytical solutions of correlation diffusion equation may lead to errors when calculating blood flow index (BFI) from diffuse correlation spectroscopy (DCS) measurements in tissues with irregular geometries. Very recently, we created an algorithm integrating a Nth-order linear model of autocorrelation function with the Monte Carlo simulation of photon migrations in homogenous tissues with arbitrary geometries for extraction of BFI (i.e., αD{sub B}). The purpose of this study is to extend the capability of the Nth-order linear algorithm for extracting BFI in heterogeneous tissues with arbitrary geometries. The previous linear algorithm was modified to extract BFIs in different types of tissues simultaneously through utilizing DCS data at multiple source-detector separations. We compared the proposed linear algorithm with the semi-infinite homogenous solution in a computer model of adult head with heterogeneous tissue layers of scalp, skull, cerebrospinal fluid, and brain. To test the capability of the linear algorithm for extracting relative changes of cerebral blood flow (rCBF) in deep brain, we assigned ten levels of αD{sub B} in the brain layer with a step decrement of 10% while maintaining αD{sub B} values constant in other layers. Simulation results demonstrate the accuracy (errors < 3%) of high-order (N ≥ 5) linear algorithm in extracting BFIs in different tissue layers and rCBF in deep brain. By contrast, the semi-infinite homogenous solution resulted in substantial errors in rCBF (34.5% ≤ errors ≤ 60.2%) and BFIs in different layers. The Nth-order linear model simplifies data analysis, thus allowing for online data processing and displaying. Future study will test this linear algorithm in heterogeneous tissues with different levels of blood flow variations and noises.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Polarization properties and disorder effects in H{sub 3} photonic crystal cavities incorporating site-controlled, high-symmetry quantum dot arrays

We report on the effects of optical disorder on breaking the symmetry of the cavity modes of H{sub 3} photonic crystal cavities incorporating site-controlled pyramidal quantum dots (QDs) as the internal light source. The high in-plane symmetry of the polarization states of the pyramidal QDs simplifies the analysis of the polarization states of the H{sub 3} cavities. It is shown that the optical disorder induced by fabrication imperfections lifts the degeneracy of the two quadrupole cavity modes and tilts the elongation axes of the cavity mode patterns with respect to the ideal, hexagonal symmetry case. These results are useful for designing QD-cavity structures for polarization-entangled photon sources and few-QD lasers.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Numerical simulation of transient moisture transfer into an electronic enclosure

Electronic systems are sometimes exposed to harsh environmental conditions of temperature and humidity. Moisture transfer into electronic enclosures and condensation can cause several problems such as corrosion and alteration in thermal stresses. It is therefore essential to study the local climate inside the enclosures to be able to protect the electronic systems. In this work, moisture transfer into a typical electronic enclosure is numerically studied using CFD. In order to reduce the CPU-time and make a way for subsequent factorial design analysis, a simplifying modification is applied in which the real 3D geometry is approximated by a 2D axial symmetry one. The results for 2D and 3D models were compared in order to calibrate the 2D representation. Furthermore, simulation results were compared with experimental data and good agreement was found.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quasioptical modeling of wave beams with and without mode conversion. IV. Numerical simulations of waves in dissipative media

We report the first quasi-optical simulations of wave beams in a hot plasma using the quasi-optical code PARADE (PAraxial RAy DEscription) [K. Yanagihara, I. Y. Dodin, and S. Kubo, Phys. Plasmas 26, 072112 (2019)]. This code is unique in that it accounts for inhomogeneity of the dissipation-rate across the beam and mode conversion simultaneously. We show that the dissipation-rate inhomogeneity shifts beams relative to their trajectories in cold plasma and that the two electromagnetic modes are coupled via this process, an effect that was ignored in the past. Additionally, we propose a simplified approach to account for the dissipation-rate inhomogeneity. This approach is computationally inexpensive and simplifies the analysis of actual experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Thermo-Mechanical Distortion of Tungsten-Coated Steel During High Heat Flux Testing Using Plasma Arc Lamps

An experimental setup and a test section were designed and fabricated for high heat flux testing (HHFT) of neutron-irradiated specimens using water-wall plasma arc lamps. Because of the radiological considerations and limitations of reactor irradiation, the size of the test articles was limited to disks less than 10 mm in diameter. The specimen was clamped onto an actively cooled block, and clamping allowed the insertion of several thermocouples on the back surface of the specimen through a copper (Cu) block. Five vacuum plasma sprayed tungsten (W)–coated F82H steel specimens were subjected to HHFT. Surface profilometry measurements, which were conducted after HHFT, revealed central bowing of the top W surface. This type of residual distortion occurred for all of the specimens, and the larger the specimens were, the larger was the distortion.In an attempt to understand specimen distortion and address the science questions related to the testing of subsize specimens during HHFT, a simplified thermo-mechanical model was developed. By using a measured temperature in the Cu as an isothermal boundary condition, the model eliminated the need for coupling cooling fluid flow models with stress models, greatly simplifying the analysis. The main variable in the proposed model is hC, i.e., the thermal contact conductance between the F82H and the Cu washer. Inelastic properties, including hardening properties, were considered for F82H steel and Cu. Numerical simulation results demonstrated a buildup of residual deformation during HHFT and a very complex state of stress and deformation during typical heat flux (HF) cycling. Additionally, hoop stress evolution during a high heat flux cycle reveals that F82H at an interface with W would be mainly in compression during HF application and experienced a transition to a tension state during cooldown. Also, specimen distortion evolves during each HF cycle, as the specimen bows downward during HF application and upward during the cooldown period between HF cycles. The final specimen distortion, i.e., upward bowing of the specimen center, was qualitatively predicted for hC values of 4000 to 5000 W/(m 2 ·K). This hC range of values, for which bulging is obtained, is at the lower spectrum of the range of values for hC, consistent with the low thermal contact conductance expected from the unpolished F82H surface.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Validity of the Taylor hypothesis for linear kinetic waves in the weakly collisional solar wind

The interpretation of single-point spacecraft measurements of solar wind turbulence is complicated by the fact that the measurements are made in a frame of reference in relative motion with respect to the turbulent plasma. The Taylor hypothesis—that temporal fluctuations measured by a stationary probe in a rapidly flowing fluid are dominated by the advection of spatial structures in the fluid rest frame—is often assumed to simplify the analysis. But measurements of turbulence in upcoming missions, such as Solar Probe Plus, threaten to violate the Taylor hypothesis, either due to slow flow of the plasma with respect to the spacecraft or to the dispersive nature of the plasma fluctuations at small scales. Assuming that the frequency of the turbulent fluctuations is characterized by the frequency of the linear waves supported by the plasma, we evaluate the validity of the Taylor hypothesis for the linear kinetic wave modes in the weakly collisional solar wind. The analysis predicts that a dissipation range of solar wind turbulence supported by whistler waves is likely to violate the Taylor hypothesis, while one supported by kinetic Alfvén waves is not.

79 ASTRONOMY AND ASTROPHYSICS↗

EXPLORING THE ROLE OF GLOBULAR CLUSTER SPECIFIC FREQUENCY ON THE NOVA RATES IN THREE VIRGO ELLIPTICAL GALAXIES

It has been proposed that a galaxy’s nova rate might be enhanced by the production of nova progenitor binaries in the dense cores of its globular clusters (GCs). To explore this idea, relative nova rates in three Virgo elliptical galaxies, M87, M49, and M84, which have significantly different GC specific frequencies (S{sub N}) of 14, 3.6, and 1.6, respectively, were measured over the course of 4 epochs spanning a period of 14 months. To simplify the analysis, observations of the nearly equidistant galaxies were made on the same nights, with the same integration times, and through the same filter (Hα), so that the relative numbers of novae discovered would reflect the relative nova rates. At the conclusion of our survey we found a total of 27 novae associated with M87, 37 with M49, and 19 with M84. After correcting for survey completeness, we found annual nova rates of 154{sub −19}{sup +23}, 189{sub −22}{sup +26}, and 95{sub −14}{sup +15}, for M87, M49, and M84, respectively, corresponding to K-band luminosity-specific nova rates of 3.8 ± 1.0, 3.4 ± 0.6, and 3.0 ± 0.6 novae per year per 10{sup 10} L{sub K,⊙}. The overall results of our study suggest that a galaxy’s nova rate simply scales with its luminosity, and is insensitive to its GC specific frequency. Two novae, one in M87 and one in M84, were found to be spatially coincident with known GCs. After correcting for the mass fraction in GCs, we estimate that novae are likely enhanced relative to the field by at least an order of magnitude in the GC systems of luminous Virgo ellipticals.

79 ASTRONOMY AND ASTROPHYSICS↗

AC losses of Roebel and CORC ® cables at higher AC magnetic fields and ramp rates

We have measured ReBCO coated conductor-based conductor on round core (CORC ® ) and Roebel cables at 77 K in a spinning magnet calorimeter, which subjected the tapes in the samples to a radial magnetic field of 566 mT (peak) at frequencies up to 120 Hz (272 T s -1 , cyclic average) with an approximately sinusoidal waveform. The samples were oriented such that the field applied to the tapes within the cables was entirely radial, simplifying subsequent analysis. An expression for loss which included hysteretic, flux creep and eddy current losses was fit to both the CORC ® and the Roebel cables. This expression allowed easy comparison of the relative influence of eddy currents and flux creep (or power-law behavior) effects. The loss of both the CORC ® and Roebel cables measured here were seen to be essentially the sum of the hysteretic loss, flux creep effects, and the normal metal eddy current losses of the individual tapes. The losses of these cables were measured at high B × d B /d t with no coupling current loss observed under the present preparation conditions. The influence of flux creep effects on loss were not negligible. The losses of the CORC ® cable per meter of tape were seen to be reduced from the case of a flat tape because of the helical geometry of the tapes.

Physics↗

Cosmic bubble and domain wall instabilities I: parametric amplification of linear fluctuations

This is the first paper in a series where we study collisions of nucleated bubbles taking into account the effects of small initial (quantum) fluctuations in a fully 3+1-dimensional setting. In this paper, we consider the evolution of linear fluctuations around highly symmetric though inhomogeneous backgrounds. In particular, we demonstrate that a large degree of asymmetry develops over time from tiny initial fluctuations superposed upon planar and SO(2,1) symmetric backgrounds. These fluctuations are inevitable consequences of zero-point vacuum oscillations, so excluding them by enforcing a high degree of spatial symmetry is inconsistent in a quantum treatment. To simplify the analysis we consider the limit of two colliding planar walls, with mode functions for the fluctuations characterized by the wavenumber transverse to the collision direction and a longitudinal shape along the collision direction x, which we solve for. In the linear regime, the fluctuations obey a linear wave equation with a time- and space-dependent mass m{sub eff}(x,t). In situations where the walls collide multiple times, m{sub eff} oscillates in time. We use Floquet theory to study the evolution of the fluctuations and generalize the calculations familiar from the preheating literature to the case with many coupled degrees of freedom. The inhomogeneous case has bands of unstable transverse wavenumbers k{sub ⊥} whose corresponding mode functions grow exponentially. By examining the detailed spatial structure of the mode functions in x, we identify both broad and narrow parametric resonance generalizations of the homogeneous m{sub eff}(t) case of preheating. The unstable k{sub ⊥} modes are longitudinally localized, yet can be described as quasiparticles in the Bogoliubov sense. We define an effective occupation number and show they are created in bursts for the case of well-defined collisions in the background. The transverse-longitudinal coupling accompanying nonlinearity radically breaks this localized particle description, with nonseparable 3D modes arising that will be studied in subsequent papers.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Not even 6 dB: Gaussian quantum illumination in thermal background

Abstract In analyses of target detection with Gaussian state transmitters in a thermal background, the thermal occupation is taken to depend on the target reflectivity in a way which simplifies the analysis of the symmetric quantum hypothesis testing problem. However, this assumption precludes comparison of target detection performance between an arbitrary transmitter and a vacuum state transmitter, i.e. ‘detection without illumination’, which is relevant in a bright thermal background because a target can be detected by its optical shadow or some other perturbation of the background. Using a target-agnostic thermal environment leads to the result that the oft-claimed 6 dB possible reduction in the quantum Chernoff exponent for a two-mode squeezed vacuum transmitter over a coherent state transmitter in high-occupation thermal background is an unachievable limiting value, only occurring in a limit in which the target detection problem is ill-posed. Further analyzing quantum illumination in a target-agnostic thermal environment shows that a weak single-mode squeezed transmitter performs worse than ‘no illumination’, which is explained by the noise-increasing property of reflected low-intensity squeezed light.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Mixing bispectrum multipoles under geometric distortions

We derive general expressions for how the Alcock–Paczynski distortions affect the power spectrum and the bispectrum of cosmological fields. We compute explicit formulas for the mixing coefficients of bispectrum multipoles in the linear approximation. The leading-order effect for the bispectrum is the uniform dilation of all three wavevectors. The mixing coefficients depend on the shape of the bispectrum triplet. Our results for the bispectrum multipoles are framed in terms of the ‘natural’ basis of the lengths of three wavevectors but can be easily generalized for other bases and reduction schemes. Our validation tests confirm that the linear approximation is extremely accurate for all power spectrum multipoles. The linear approximation is accurate for the bispectrum monopole but results in sub-per cent level inaccuracies for the bispectrum quadrupole and fails for the bispectrum hexadecapole. Our results can be used to simplify the analysis of the bispectrum from galaxy surveys, especially the measurement of the baryon acoustic oscillation peak position. They can be used to replace numeric schemes with exact analytical formulae.

79 ASTRONOMY AND ASTROPHYSICS↗

Single Cs atoms as collisional probes in a large Rb magneto-optical trap

We study cold interspecies collisions of cesium and rubidium in a strongly imbalanced system with single and few Cs atoms. Observation of the single-atom fluorescence dynamics yields insight into light-induced loss mechanisms, while both subsystems can remain in steady state. This significantly simplifies the analysis of the dynamics, as Cs-Cs collisions are effectively absent and the majority component remains unaffected, allowing us to extract a precise value of the Rb-Cs collision parameter. Extending our results to ground-state collisions would allow to use single neutral atoms as coherent probes for larger quantum systems.

74 ATOMIC AND MOLECULAR PHYSICS↗