Search NASA⌕ Search

SEARCH · Search NASA

Results for “spatial accelerator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Novel Generation Method of 24-keV Monoenergetic Neutrons Using Accelerators

This paper describes a novel 24-keV monoenergetic neutron source that consists of an iron filter and a thick lithium target. The 24 keV neutrons are obtained with iron filtering of a neutron beam from the {sup 7}Li(p,n){sup 7}Be reaction near threshold energy using the 4 MV Pelletron accelerator. Neutron spectra were calculated using the NRESP-ANT simulation code. This neutron source was investigated using a {sup 3}He cylindrical proportional counter to measure the spatial distribution and neutron flux.

43 PARTICLE ACCELERATORS↗

SIMULATIONS OF THE SPATIAL AND TEMPORAL INVARIANCE IN THE SPECTRA OF GRADUAL SOLAR ENERGETIC PARTICLE EVENTS

The spatial and temporal invariance in the spectra of energetic particles in gradual solar events is reproduced in simulations. Based on a numerical solution of the focused transport equation, we obtain the intensity time profiles of solar energetic particles (SEPs) accelerated by an interplanetary shock in three-dimensional interplanetary space. The shock is treated as a moving source of energetic particles with a distribution function. The time profiles of particle fluxes with different energies are calculated in the ecliptic at 1 AU. According to our model, we find that shock acceleration strength, parallel diffusion, and adiabatic cooling are the main factors in forming the spatial invariance in SEP spectra, and perpendicular diffusion is a secondary factor. In addition, the temporal invariance in SEP spectra is mainly due to the effects of adiabatic cooling. Furthermore, a spectra invariant region, which agrees with observations but is different from the one suggested by Reames et al. is proposed based on our simulations.

79 ASTRONOMY AND ASTROPHYSICS↗

Experimental longitudinal emittance manipulation using laser-based photoionization in the Fermilab Linac

A series of simulations and beam studies were conducted at Fermilab’s linear accelerator to evaluate the effectiveness of longitudinal emittance control via laser-induced photoionization. While similar laser techniques have been employed at Fermilab to enhance injection and extraction efficiency into the Booster, the work presented here focuses on extending these methods to bunch-by-bunch manipulation. This approach utilizes fine-scale correction of the H- bunches’ longitudinal spatial distribution. In theory, loosely confined particles in longitudinal phase space contribute to emittance growth during acceleration. By selectively removing these outlying particles through laser scraping (H- + γ → H + e-), this growth can be reduced. This report presents experimental results from both symmetric and asymmetric longitudinal scraping of H⁻ bunches in the Fermilab linac, which were subsequently injected into Booster, and evaluates the broader applicability of this method for future high-intensity accelerator operations.

Landon, Parker [Boston U.; Fermilab]↗

Dimensionality reduction and polynomial chaos acceleration of Bayesian inference in inverse problems

We consider a Bayesian approach to nonlinear inverse problems in which the unknown quantity is a spatial or temporal field, endowed with a hierarchical Gaussian process prior. Computational challenges in this construction arise from the need for repeated evaluations of the forward model (e.g., in the context of Markov chain Monte Carlo) and are compounded by high dimensionality of the posterior. We address these challenges by introducing truncated Karhunen-Loeve expansions, based on the prior distribution, to efficiently parameterize the unknown field and to specify a stochastic forward problem whose solution captures that of the deterministic forward model over the support of the prior. We seek a solution of this problem using Galerkin projection on a polynomial chaos basis, and use the solution to construct a reduced-dimensionality surrogate posterior density that is inexpensive to evaluate. We demonstrate the formulation on a transient diffusion equation with prescribed source terms, inferring the spatially-varying diffusivity of the medium from limited and noisy data.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Enhanced spatial resolution of Eljen-204 plastic scintillators for use in rep-rated proton diagnostics

A pixelated scintillator has been designed, fabricated, and tested using a laser-accelerated proton source for use in proton diagnostics at rep-rated laser facilities. The work presented here demonstrates the enhanced spatial resolution of thin, organic scintillators through a novel pixelation technique. Furthermore, experimental measurements using laser-generated protons incident onto 130 μm-thick scintillators indicate a >20% reduction in the scintillator point spread function (PSF) for the detectors tested. The best performing pixelated detector reduced the ~200 μm PSF of the stock material to ~150 μm. The fabrication technique may be tailored to reduce the pixel size and achieve higher spatial resolutions.

47 OTHER INSTRUMENTATION↗

Controllable high-quality electron beam generation by phase slippage effect in layered targets

The bubble structure generated by laser-plasma interactions changes in size depending on the local plasma density. The self-injection electrons' position with respect to wakefield can be controlled by tailoring the longitudinal plasma density. A regime to enhance the energy of the wakefield accelerated electrons and to improve the beam quality is proposed and achieved using layered plasmas with increasing densities. Both the wakefield size and the electron bunch duration are significantly contracted in this regime. The electrons remain in the strong acceleration phase of the wakefield, while their energy spread decreases because of their tight spatial distribution. An electron beam of 0.5 GeV with less than 1% energy spread is obtained through 2.5D particle-in-cell simulations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Spatially resolved polarization swings in the supermassive binary black hole candidate OJ 287 with first Event Horizon Telescope observations

We present the first Event Horizon Telescope 1.3 mm observations of the supermassive binary black hole candidate OJ 287. The observations achieved an unprecedented angular resolution of 18 μas and reveal significant structural and polarization variability over just five days, marking the shortest timescale on which such changes have been directly imaged in this source. The inner jet exhibits a twisted ridgeline structure, with features displaying apparent superluminal motions up to about 22 c. The linear polarization maps reveal three main polarized features whose electric-vector position angles (EVPAs) change substantially over the time span of our observations, including a component with a radial polarization consistent with being produced by a recollimation shock. Most notably, we directly resolved two innermost jet components whose EVPAs rotate in opposite directions. The faster component, moving at 2.4 ± 0.9 μas/day (17.4 ± 6.5 c), exhibits counterclockwise EVPA swings of roughly 3.7° per day, while the slower component, with a proper motion of 1.4 ± 0.3 μas/day (10.2 ± 2.2 c), rotates clockwise at approximately 2.5° per day. Previous studies inferred helical magnetic fields in AGN jets from time-resolved or integrated polarization variability but lacked the angular resolution to directly image this effect. Our results provide spatially resolved evidence that a helical magnetic field threads the jet’s collimation and acceleration zone, ruling out models based on the superposition of unresolved components. Our analysis suggests that propagating shocks interact with a Kelvin–Helmholtz plasma instability, illuminating different phases of the helical magnetic field and producing the observed polarization spatial and temporal variability. Moreover, our model naturally accounts for the more rapid polarization rotation observed in the faster moving component. Our model predicts even more rapid swings in polarization, which could be tested with future observations featuring a more densely sampled time coverage.

OJ 287↗

The DOSIMAP, a high spatial resolution tissue equivalent 2D dosimeter for LINAC QA and IMRT verification

The continual need for more accurate and effective techniques in radiation therapy makes it necessary to devise new control means combining high spatial resolution as well as high dose accuracy. Intensity modulated radio therapy (IMRT) allows highly conformed fields with high spatial gradient and therefore requires a precise monitoring of all the multileaf positions. In response to this need, the authors have developed a new 2D tissue equivalent dosimeter with high spatial resolution. A plastic scintillator sheet is sandwiched between two polystyrene blocks and the emitted light is captured by a high resolution camera. A newly developed procedure described herein allows efficient discrimination of the scintillation from the parasitic Cerenkov radiation. This processing is applied on the cumulated image from a sequence of images taken during an irradiation field at a rate of 10 images/s. It provides a high resolution mapping of the cumulated dose in quasireal time. The dosimeter is tissue equivalent (ICRU-44) and works both for electrons and photons without complex parameter adjustment since phantom and detector materials are identical. Instrument calibration is simple and independent of the irradiation conditions (energy, fluence, quality, ...). In this article, the authors present the principle of the dosimeter and its calibration procedure. They compare the results obtained for photons and electron beams with ionization chamber measurements in polystyrene. Technical specifications such as accuracy and repeatability are precisely evaluated and discussed. Finally, they present different IMRT field measurements and compare DOSIMAP measurements to TPS simulations and dosimetric film profiles. The results confirm the excellent spatial resolution of the instrument and its capacity to inspect the leaf positions for each segment of a given field.

61 RADIATION PROTECTION AND DOSIMETRY↗

Improved Spatial Resolution For Reflection Mode Infrared Spectromicroscopy

Standard commercial infrared microscopes operating in reflection mode use a mirror to direct the reflected light from the sample to the detector. This mirror blocks about half of the incident light, however, and thus degrades the spatial resolution by reducing the numerical aperture of the objective. Here, we replace the mirror with a 50% beamsplitter to allow full illumination of the objective and retain a way to direct the reflected light to the detector. The improved spatial resolution is demonstrated using a microscope coupled to a synchrotron source.

47 OTHER INSTRUMENTATION↗

Spatial resolution limits for synchrotron-based infrared spectromicroscopy

Detailed spatial resolution tests were performed on beamline 1.4.4 at the Advanced Light Source synchrotron facility in Berkeley, CA. The high-brightness synchrotron source is coupled at this beamline to a Thermo-Electron Continumum XL infrared microscope. Two types of resolution tests in both the mid-IR (using a KBr beamsplitter and an MCT-A* detector) and in the near-IR (using a CaF2 beamsplitter and an InGaAS detector) were performed and compared to a simple diffraction-limited spot size model. At the shorter wavelengths in the near-IR the experimental results begin to deviate from only diffraction-limited. The entire data set is fit using a combined diffraction-limit and demagnified electron beam source size model. This description experimentally verifies how the physical electron beam size of the synchrotron source demagnified to the sample stage on the endstation begins to dominate the focussed spot size and therefore spatial resolution at higher energies. We discuss how different facilities, beamlines, and microscopes will affect the achievable spatial resolution.

43 PARTICLE ACCELERATORS↗

A scintillator-based online detector for the angularly resolved measurement of laser-accelerated proton spectra

In recent years, a new generation of high repetition rate ({approx}10 Hz), high power ({approx}100 TW) laser systems has stimulated intense research on laser-driven sources for fast protons. Considering experimental instrumentation, this development requires online diagnostics for protons to be added to the established offline detection tools such as solid state track detectors or radiochromic films. In this article, we present the design and characterization of a scintillator-based online detector that gives access to the angularly resolved proton distribution along one spatial dimension and resolves 10 different proton energy ranges. Conceived as an online detector for key parameters in laser-proton acceleration, such as the maximum proton energy and the angular distribution, the detector features a spatial resolution of {approx}1.3 mm and a spectral resolution better than 1.5 MeV for a maximum proton energy above 12 MeV in the current design. Regarding its areas of application, we consider the detector a useful complement to radiochromic films and Thomson parabola spectrometers, capable to give immediate feedback on the experimental performance. The detector was characterized at an electrostatic Van de Graaff tandetron accelerator and tested in a laser-proton acceleration experiment, proving its suitability as a diagnostic device for laser-accelerated protons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hubble Parameter Measurement Constraints on The Redshift of The Deceleration–Acceleration Transition, Dynamical Dark Energy, and Space Curvature

We compile an updated list of 38 measurements of the Hubble parameter $H(z)$ between redshifts 0.07 $≤ z ≤$ 2.36 and use them to place constraints on model parameters of constant and time-varying dark energy cosmological models, both spatially flat and curved. We use five models to measure the redshift of the cosmological deceleration–acceleration transition, $z_{da}$, from these H(z) data. Within the error bars, the measured zda are insensitive to the model used, depending only on the value assumed for the Hubble constant $H_0$. The weighted mean of our measurements is $z_{da}$ = 0.72 ± 0.05 (0.84 ± 0.03) for $H_0$ = 68 ± 2.8 (73.24 ± 1.74) km s -1 Mpc -1 and should provide a reasonably model-independent estimate of this cosmological parameter. The H(z) data are consistent with the standard spatially flat ΛCDM cosmological model but do not rule out nonflat models or dynamical dark energy models.

79 ASTRONOMY AND ASTROPHYSICS↗

Sub-cycle dynamics in relativistic nanoplasma acceleration

The interaction of light with nanometer-sized solids provides the means of focusing optical radiation to sub-wavelength spatial scales with associated electric field enhancements offering new opportunities for multifaceted applications. We utilize collective effects in nanoplasmas with sub-two-cycle light pulses of extreme intensity to extend the waveform-dependent electron acceleration regime into the relativistic realm, by using 106 times higher intensity than previous works to date. Through irradiation of nanometric tungsten needles, we obtain multi-MeV energy electron bunches, whose energy and direction can be steered by the combined effect of the induced near-field and the laser field. We identified a two-step mechanism for the electron acceleration: (i) ejection within a sub-half-optical-cycle into the near-field from the target at >TVm -1 acceleration fields, and (ii) subsequent acceleration in vacuum by the intense laser field. Our observations raise the prospect of isolating and controlling relativistic attosecond electron bunches, and pave the way for next generation electron and photon sources.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High-resolution phase-contrast imaging of biological specimens using a stable betatron X-ray source in the multiple-exposure mode

Abstract Phase-contrast imaging using X-ray sources with high spatial coherence is an emerging tool in biology and material science. Much of this research is being done using large synchrotron facilities or relatively low-flux microfocus X-ray tubes. An alternative high-flux, ultra-short and high-spatial-coherence table-top X-ray source based on betatron motions of electrons in laser wakefield accelerators has the promise to produce high quality images. In previous phase-contrast imaging studies with betatron sources, single-exposure images with a spatial resolution of 6–70 μ m were reported by using large-scale laser systems (60–200 TW). Furthermore, images obtained with multiple exposures tended to have a reduced contrast and resolution due to the shot-to-shot fluctuations. In this article, we demonstrate that a highly stable multiple-exposure betatron source, with an effective average source size of 5 μ m, photon number and pointing jitters of <5% and spectral fluctuation of <10%, can be obtained by utilizing ionization injection in pure nitrogen plasma using a 30–40 TW laser. Using this source, high quality phase-contrast images of biological specimens with a 5- μ m resolution are obtained for the first time. This work shows a way for the application of high resolution phase-contrast imaging with stable betatron sources using modest power, high repetition-rate lasers.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measurements and Studies of Secondary Electron Emission of Diamond Amplified Photocathode

Over many years, electron accelerators have served in a large variety of applications. Besides the contribution of electron colliders such as LEP in the precise measurements of important values in the Standard Model, scientists and engineers have made possible high brightness, constant power, and short wavelength light sources to be possible. Synchrotron Light Sources and Free Electron Lasers (FEL) provide the largest work platforms with high X-ray energy and brightness for biology, chemistry, material science, medical science, and much more. Many applications require continuous current, high intensity electron beams with narrow spatial and temporal distributions.

43 PARTICLE ACCELERATORS↗

PROBING DYNAMICS OF ELECTRON ACCELERATION WITH RADIO AND X-RAY SPECTROSCOPY, IMAGING, AND TIMING IN THE 2002 APRIL 11 SOLAR FLARE

Based on detailed analysis of radio and X-ray observations of a flare on 2002 April 11 augmented by realistic three-dimensional modeling, we have identified a radio emission component produced directly at the flare acceleration region. This acceleration region radio component has distinctly different (1) spectrum, (2) light curves, (3) spatial location, and, thus, (4) physical parameters from those of the separately identified trapped or precipitating electron components. To derive evolution of physical parameters of the radio sources we apply forward fitting of the radio spectrum time sequence with the gyrosynchrotron source function with five to six free parameters. At the stage when the contribution from the acceleration region dominates the radio spectrum, the X-ray- and radio-derived electron energy spectral indices agree well with each other. During this time the maximum energy of the accelerated electron spectrum displays a monotonic increase with time from {approx}300 keV to {approx}2 MeV over roughly one minute duration indicative of an acceleration process in the form of growth of the power-law tail; the fast electron residence time in the acceleration region is about 2-4 s, which is much longer than the time of flight and so requires a strong diffusion mode there to inhibit free-streaming propagation. The acceleration region has a relatively strong magnetic field, B {approx} 120 G, and a low thermal density, n{sub e} {approx}< 2 Multiplication-Sign 10{sup 9} cm{sup -3}. These acceleration region properties are consistent with a stochastic acceleration mechanism.

79 ASTRONOMY AND ASTROPHYSICS↗

TIME-DEPENDENT STOCHASTIC ACCELERATION MODEL FOR FERMI BUBBLES

We study stochastic acceleration models for the Fermi bubbles. Turbulence is excited just behind the shock front via Kelvin–Helmholtz, Rayleigh–Taylor, or Richtmyer–Meshkov instabilities, and plasma particles are continuously accelerated by the interaction with the turbulence. The turbulence gradually decays as it goes away from the shock fronts. Adopting a phenomenological model for the stochastic acceleration, we explicitly solve the temporal evolution of the particle energy distribution in the turbulence. Our results show that the spatial distribution of high-energy particles is different from those for a steady solution. We also show that the contribution of electrons that escaped from the acceleration regions significantly softens the photon spectrum. The photon spectrum and surface brightness profile are reproduced by our models. If the escape efficiency is very high, the radio flux from the escaped low-energy electrons can be comparable to that of the WMAP haze. We also demonstrate hadronic models with the stochastic acceleration, but they are unlikely in the viewpoint of the energy budget.

79 ASTRONOMY AND ASTROPHYSICS↗

Absolute bunch length measurements by incoherent radiation fluctuation analysis

By analyzing the pulse to pulse intensity fluctuations of the radiation emitted by a charge particle in the incoherent part of the spectrum, it is possible to extract information about the spatial distribution of the beam. At the Advanced Light Source (ALS) of the Lawrence Berkeley National Laboratory, we have developed and successfully tested a simple scheme based on this principle that allows for the absolute measurement of the rms bunch length. A description of the method and the experimental results are presented.

43 PARTICLE ACCELERATORS↗