Search NASA⌕ Search

SEARCH · Search NASA

Results for “standard model tests”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

PV Inverter Testing for Momentary Cessation and Rate-of-Change-of-Frequency Events

To understand the power system stability and develop better electromagnetic transient (EMT) models of field deployed photovoltaic (PV) inverters, it is important to characterize inverters' response to abnormal voltage and frequency scenarios. Because EMT models are not typically available for small distribution-connected PV inverters, and because inerterconnection standards historically did not specify desired ride-through behaviors, we tested two such inverters in the lab to characterize their responses to severe undervoltage events and high rate-of-change-of-frequency (ROCOF) conditions. The inverters tested were pre-IEEE 1547-2018 residential PV inverters widely used in the Hawaiian Electric territory and many other areas. The testing results for undervoltage scenarios showed that the inverter from one vendor exhibited momentary cessation while the inverter from the other vendor did not exhibit momentary cessation behavior or tripping for most of the events below the 120 ms undervoltage trip threshold duration set by IEEE 1547-2003. The testing results for ROCOF scenarios showed that the inverter from one vendor temporarily lost synchronization during ROCOF conditions while the inverter from the other vendor did not lose synchronization or cease generation for any ROCOF conditions. Both the inverters were also tested for EMT-simulated grid events with severe changes in frequency and voltage. The observed responses of the inverters were different from the simulated response of PV inverters represented the best available assumptions from pre-existing information. The results from these experiments can be used to update the inverter models used in bulk power system studies.

aggregates↗

A novel, steerable, low-energy proton source for detector characterization

We report on the conversion of the Manitoba II mass spectrometer into a versatile low-energy proton beam facility. This infrastructure is adaptable to any detector-under-test (DUT), and has proven itself effective with the characterization of silicon detectors used in subatomic beyond-the-Standard-Model (BSM) searches, namely the Nab experiment. A pencil beam of mono-energetic protons can be produced in a range from 25 keV to 35 keV, achieving a beam current of ~1 x 10 -18 A. Electrostatic steering plates were constructed to direct the Gaussian-profile proton beam over a 117 mm diameter area-of-interest with full-width at half-maxima (FWHM) ranging from 0.6 mm to 1.26 mm. This work discusses the modifications and subsequent tests to confirm the beam specifications met the demands of the aforementioned detectors.

Fundamental neutron physics↗

PV Inverter Testing for Momentary Cessation and Rate-of-Change-of-Frequency Events: Preprint

To understand the power system stability and develop better electromagnetic transient (EMT) models of field deployed photovoltaic (PV) inverters, it is important to characterize inverters' response to abnormal voltage and frequency scenarios. Because EMT models are not typically available for small distribution-connected PV inverters, and because inerterconnection standards historically did not specify desired ride-through behaviors, we tested two such inverters in the lab to characterize their responses to severe undervoltage events and high rate-of-change-of-frequency (ROCOF) conditions. The inverters tested were pre-IEEE 1547-2018 residential PV inverters widely used in the Hawaiian Electric territory and many other areas. The testing results for undervoltage scenarios showed that the inverter from one vendor exhibited momentary cessation while the inverter from the other vendor did not exhibit momentary cessation behavior or tripping for most of the events below the 120 ms undervoltage trip threshold duration set by IEEE 1547-2003. The testing results for ROCOF scenarios showed that the inverter from one vendor temporarily lost synchronization during ROCOF conditions while the inverter from the other vendor did not lose synchronization or cease generation for any ROCOF conditions. Both the inverters were also tested for EMT-simulated grid events with severe changes in frequency and voltage. The observed responses of the inverters were different from the simulated response of PV inverters represented the best available assumptions from pre-existing information. The results from these experiments can be used to update the inverter models used in bulk power system studies.

IEEE 1547 2018↗

The shard test and nanoporomechanics reverse classical paradigm of cement hydration being contractive

Le Chatelier in 1887 and Powers in 1947 demonstrated that the volume of nanoscale C-S-H (calcium silicate hydrate) particles formed during hydration is smaller than the combined volume of the reactants—the anhydrous Portland cement and water. Hydration has thus been considered as contractive. An experiment shows that the opposite is true above the nanoscale. The porous skeleton of cement paste expands as the growing C-S-H particles push each other apart, similar to crystal growth pressure. This is significant for high-performance concretes (HPC) with low water-cement ratios (w/c ≤ 0.4), where chemical self-desiccation lowers pore relative humidity by 40%, compared to just 1% in traditional concretes (w/c ≈ 0.5). Standard American Society for Testing and Materials (ASTM) C1608 tests, using 10 mm thick water-immersed specimens, show large shrinkage because the half-time of water ingress is many decades, unable to offset shrinkage-causing self-desiccation. The present experiment, using a laser microscopy-topography technique, proves the opposite—expansion, evidenced by measuring the length changes of water-immersed HPC shards 0.5 mm thick in which the diffusion halftime, only about one hour, allows continuous resaturation of pores, canceling self-desiccation. The faster diffusion (halftime of one hour) enables continuous pore resaturation, preventing shrinkage. When sealed with paraffin oil, the shards self-desiccate and shrink. These findings align with studies since 2015, showing that models excluding hydration expansion cannot fit test data across various specimen sizes and sealing conditions. The results suggest that standardized ASTM tests for the so-called chemical shrinkage in modern concretes with very low water-cement ratios are misleading and need revision.

Science & Technology - Other Topics↗

Performance Testing and Assessment of Protection Scheme Using Real-Time Hardware-in-the-Loop and IEC 61850 Standard

The main challenge of the microgrid is to design a suitable protection scheme due to the complexity of the architecture of the microgrid. The importance of the proposed protection technique is threefold. First, it presents a co-simulation platform to integrate between a simulated model on power system computer aided design (PSCAD)/real time digital simulator computer aided design (RSCAD) software’s and physical devices schweitzer engineering laboratories (SEL) 421-7 relays to protect the microgrid that includes different resources connected based on inverter interface. Second, it presents a comprehensive hardware/software setup to test the protective relays in a closed loop system and shows how to configure the protective relay’s International Electrotechnical Commission 61850 communications. Third, IEEE 1588 standard is used to provide sub nanoseconds latency between the simulated model that emulated on real time digital simulator (RTDS) and the external devices. Also, the measurement signals are synchronized between RTDS and the external devices using giga-transceiver synchronization card (GTSYNC) interface card and SEL-2488 satellite-synchronized network clock. The results showed that the co-simulation infrastructure introduces a highly dependable design, analysis, and testing environment for cyber and physical data flow in the system. Besides that, the voltages at ac/dc sides and frequency at fault condition were maintained due to the energy storage device contributions at different modes of operation.

42 ENGINEERING↗

A Data-Driven Passive Islanding Detection Scheme

This paper proposes a simple yet effective statistical parameters based passive islanding scheme. The proposed scheme relies only the voltage data, measured at the point of common coupling (PCC), and is comprised of three stages. The Stage-1 quickly computes what is termed as mean based coarse islanding detection (MID), Stage-2 computes the decaying DC detector (DDCD), and 3) finally, MID is used in conjunction with DDCD as per the statistical digital relay logic (SRDL) is devised in Stage-3 to distinguish between islanding events from non islanding events. Various tests are investigated on the Banshee's industrial Microgrid (MG), modelled in the Real Time Digital Simulator (RTDS), on the basis of the IEEE-1547, UL 1741 standards. The validation of the proposed islanding detection methodology (PIDM) in RTDS platform ensures the viability of the proposed scheme in practical systems. The test results reveal that the PIDM can detect islanding within 2 cycles, and results in a very small non detection zone (NDZ). Moreover, the scheme can very well be used for single-phase MG too as it relies only on the single phase voltage information.

anti-islanding protection↗

Accelerated Irradiation Testing and Post-Irradiation Characterization: U.S.-Based Capabilities for Advanced Nuclear Systems and Radioisotope Production

Irradiation experiments and post-irradiation examinations, together referred to as irradiation testing (IRT), are prerequisites for nuclear fuel and material qualification for the deployment of new and advanced reactors, as well as radioisotope production, thereby ensuring regulatory compliance. Qualified research and test reactors (RTRs) and testing facilities are essential to enable IRT to verify performance and safety under prototypical reactor conditions. In the past, qualification of new fuels or structural materials required about 20 years. Synergist strategies, advanced tools, and qualified methods are needed to greatly reduce this timeframe of IRT and radioisotope production. This study, termed accelerated-IRT, focuses on identifying gaps and leveraging U.S.-based RTRs and material testing capabilities, leveraging the preliminary evaluation and qualification of selected RTRs to provide a generic as well as specific-case solution paths forward, ensuring adherence to stringent regulatory standards. Furthermore, IRT and radioisotope production utilizing qualified RTRs necessarily includes modeling and simulation to support the design (i.e. neutronics, thermal, and structural aspects) and manufacturing of irradiation test specimens, vehicles, capsules, apparatuses, and flow loops. In addition, IRT can be improved by applying advanced manufacturing techniques and in-pile sensors and instrumentation, as discussed in this study.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

White paper on light sterile neutrino searches and related phenomenology

This white paper provides a comprehensive review of our present understanding of experimental neutrino anomalies that remain unresolved, charting the progress achieved over the last decade at the experimental and phenomenological level, and sets the stage for future programmatic prospects in addressing those anomalies. It is purposed to serve as a guiding and motivational "encyclopedic" reference, with emphasis on needs and options for future exploration that may lead to the ultimate resolution of the anomalies. We see the main experimental, analysis, and theory-driven thrusts that will be essential to achieving this goal being: 1) Cover all anomaly sectors -- given the unresolved nature of all four canonical anomalies, it is imperative to support all pillars of a diverse experimental portfolio, source, reactor, decay-at-rest, decay-in-flight, and other methods/sources, to provide complementary probes of and increased precision for new physics explanations; 2) Pursue diverse signatures -- it is imperative that experiments make design and analysis choices that maximize sensitivity to as broad an array of these potential new physics signatures as possible; 3) Deepen theoretical engagement -- priority in the theory community should be placed on development of standard and beyond standard models relevant to all four short-baseline anomalies and the development of tools for efficient tests of these models with existing and future experimental datasets; 4) Openly share data -- Fluid communication between the experimental and theory communities will be required, which implies that both experimental data releases and theoretical calculations should be publicly available; and 5) Apply robust analysis techniques -- Appropriate statistical treatment is crucial to assess the compatibility of data sets within the context of any given model.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Tula: Optimizing Time, Cost, and Generalization in Distributed Large-Batch Training

Distributed training increases the number of batches processed per iteration either by scaling-out (adding more nodes) or scaling-up (increasing the batch-size). However, the largest configuration does not necessarily yield the best performance. Horizontal scaling introduces additional communication overhead, while vertical scaling is constrained by computation cost and device memory limits. Thus, simply increasing the batch-size leads to diminishing returns: training time and cost decrease initially but eventually plateaus, creating a knee-point in the time/cost vs. batch-size pareto curve. The optimal batch-size therefore depends on the underlying model, data and available compute resources. Large batches also suffer from worse model quality due to the well-known “generalization gap”. In this paper, we present Tula, an online service that automatically optimizes time, cost, and convergence quality for large-batch training of convolutional models. It combines parallel-systems modeling with statistical performance prediction to identify the optimal batchsize. Tula predicts training time and cost within 7.5−14% error across multiple models, and achieves up to 20× overall speedup and improves test accuracy by ≈9% on average over standard large-batch training on various vision tasks, thus successfully mitigating the generalization gap and accelerating training at the same time.

Tyagi, Sahil [ORNL] (ORCID:0009000783144745)↗

System Resilience Benefits of Dual-Fuel Capable Generators

The growing dependency on natural gas (NG) for power generation raises challenges for ensuring the resilience of power systems during extreme cold weather. Dual-fuel capable generators that can switch from burning NG to distillate fuel oil during a NG shortage offer one way to alleviate these challenges. In this study, the impacts of gas unavailability on the IEEE 73- bus reliability test system (RTS) with 2019 updated generation mixture are explored. An extension to the standard production cost model formulation of unit commitment and economic dis- patch is proposed to allow representation of dual-fuel capable generators that can switch fuels between NG and distillate oil with a specified oil tank capacity and tank refueling capability. The operation of the system under gas unavailability with 0%, 25%, 50%, 75%, and 100% of combined cycle and combustion turbine generators as dual-fuel capable with a one-day supply of fuel oil are simulated using PLEXOS, a production cost model. The dual-fuel generator performance, unserved energy, and system costs are fully assessed.

duel-fuel generator performance↗

Too Good to Be True? Evaluation of Colonoscopy Sensitivity Assumptions Used in Policy Models

Background: Models can help guide colorectal cancer screening policy. Although models are carefully calibrated and validated, there is less scrutiny of assumptions about test performance. Methods: We examined the validity of the CRC-SPIN model and colonoscopy sensitivity assumptions. Standard sensitivity assumptions, consistent with published decision analyses, assume sensitivity equal to 0.75 for diminutive adenomas (<6 mm), 0.85 for small adenomas (6–10 mm), 0.95 for large adenomas (≥10 mm), and 0.95 for preclinical cancer. We also selected adenoma sensitivity that resulted in more accurate predictions. Targets were drawn from the Wheat Bran Fiber study. In the study, we examined how well the model predicted outcomes measured over a three-year follow-up period, including the number of adenomas detected, the size of the largest adenoma detected, and incident colorectal cancer. Results: Using standard sensitivity assumptions, the model predicted adenoma prevalence that was too low (42.5% versus 48.9% observed, with 95% confidence interval 45.3%–50.7%) and detection of too few large adenomas (5.1% versus 14.% observed, with 95% confidence interval 11.8%–17.4%). Predictions were close to targets when we set sensitivities to 0.20 for diminutive adenomas, 0.60 for small adenomas, 0.80 for 10- to 20-mm adenomas, and 0.98 for adenomas 20 mm and larger. Conclusions: Colonoscopy may be less accurate than currently assumed, especially for diminutive adenomas. Alternatively, the CRC-SPIN model may not accurately simulate onset and progression of adenomas in higher-risk populations. Impact: Misspecification of either colonoscopy sensitivity or disease progression in high-risk populations may affect the predicted effectiveness of colorectal cancer screening. When possible, decision analyses used to inform policy should address these uncertainties.

60 APPLIED LIFE SCIENCES↗

DistOPF: Advanced Solutions for Distribution Optimal Power Flow Analysis - DistOPF v0.2 Documentation

To achieve an affordable and reliable energy system, research on power distribution system is often focused on integration of distributed generators, energy storage solution, EV charging, smart meters, and other advanced assets that may benefit from or require more advanced control and optimization techniques. Despite this focus on advanced distribution system topics, early researchers and grid scientists often start from scratch when developing optimization programs for power distribution systems. This report introduces DistOPF, a Python package that consolidates years of research into a versatile and modular tool. DistOPF provides researchers with essential capabilities to solve distribution system Optimal Power Flow (OPF) problems using standard network models. Additionally, it offers a platform to benchmark both new and existing algorithms against established test systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Sensitivity of aerosol optical properties to the aerosol size distribution over central Europe and the Mediterranean Basin using the WRF-Chem v.3.9.1.1 coupled model

The size distribution of atmospheric aerosols plays a key role for understanding and quantifying the uncertainties related to aerosol–radiation and aerosol–cloud interactions. These interactions ultimately depend on the size distribution through optical properties (such as aerosol optical depth, AOD) or cloud microphysical properties. Hence, the main objective of this contribution is to disentangle the impact of the representation of aerosol size distribution on aerosol optical properties over central Europe, particularly over the Mediterranean Basin, during a summertime aerosol episode. To fulfill this objective, a sensitivity test has been conducted using the coupled chemistry–meteorology model WRF-Chem (Weather Research Forecast model coupled with Chemistry). The test modified the parameters defining a lognormal size distribution (geometric diameter and standard deviation) by 10 %, 20 %, and 50 %. Results reveal that the reduction in the standard deviation of the accumulation mode leads to the largest impacts on AOD due to a transfer of particles from the accumulation mode to the coarse mode. A reduction in the geometric diameter of the accumulation mode also has an influence on AOD representation since particles in this mode are assumed to be smaller. In addition, an increase in the geometric diameter of the coarse mode produces a redistribution through the total size distribution by relocating particles from the finer modes to the coarse.

54 ENVIRONMENTAL SCIENCES↗

System Resilience Benefits of Dual-Fuel Capable Generators

The growing dependency on natural gas (NG) for power generation raises challenges for ensuring the resilience of power systems during extreme cold weather. Dual-fuel capable generators that can switch from burning NG to distillate fuel oil during an NG shortage over one way to alleviate these challenges. In this study, the impacts of gas unavailability on the IEEE 73-bus reliability test system (RTS) with 2019 updated generation mixture are explored. An extension to the standard production cost model formulation of unit commitment and economic dispatch is proposed to allow the representation of dual-fuel capable generators that can switch fuels between NG and distillate oil with a specified oil tank capacity and tank refueling capability. The operation of the system under gas unavailability with 0%, 25%, 50%, 75%, and 100% of combined cycle and combustion turbine generators as dual-fuel capable with a one-day supply of fuel oil are simulated using PLEXOS, a production cost model. The dual-fuel generator performance, unserved energy, and system costs are fully assessed.

dual-fuel capable generator↗

Knowledge Oriented Graph Unified Transformer (KOGUT) v0.1

KOGUT — Knowledge Oriented Graph Unified Transformer KOGUT implements the Relational Graph Transformer (RelGT) architecture for knowledge graph link prediction in biological domains, with a primary focus on microbial growth media prediction. While the original RelGT (arXiv:2505.10960) targets relational tables, time series, and multi-table databases, KOGUT adapts this architecture for heterogeneous biological knowledge graphs, providing first-in-class AI predictive models for microbial cultivation. Key Adaptations Beyond Original RelGT: - Knowledge Graph Focus: Applied to biological KGs with semantic node types (taxa, chemicals, media, phenotypes, environments) versus generic relational database tables, trained on the KG-Microbe knowledge graph (1.3M entities, 2.9M edges, 24 relation types). - Multimodal Node Encoding: Integrates node labels, categories, descriptions, and synonyms from KG metadata through learned embedding layers—adapting relational column features to graph node attributes with textual semantics. - Extended K-Hop Subgraph Strategy: Optimized neighborhood sampling (3-hop default, configurable up to 200 nodes) tuned for sparse biological networks, building on the original local-global attention framework with biological relation preservation. - Biolink Predicate Preservation: Type-specific transformations for 24 biological edge semantics (occurs_in, consumes, produces, has_phenotype, subclass_of) beyond standard relational foreign keys, enabling multi-relation link prediction. - Inductive Learning Support: Enables zero-shot predictions for novel taxa through feature-based embeddings (temperature, oxygen requirements, gram stain, cell shape), extending the original transductive relational benchmark scope to uncultured microorganisms. CheapSOTA Performance Optimizations (This Distribution): - VQ-EMA Centroid Attention: Vector quantization with exponential moving average for improved global context modeling (+5-10% MRR improvement). - HDF5 Precomputed Data Loading: One-time preprocessing of k-hop subgraphs to eliminate redundant graph traversals (2-5× training speedup). - Distributed Data Parallel Training: Multi-GPU support for scaling to larger knowledge graphs (tested on 4× NVIDIA A100 GPUs at NERSC Perlmutter). - Mixed Precision Training: Automatic mixed precision (AMP) for memory efficiency and faster training. Advantages Over Standard Knowledge Graph Embedding Models: Combines RelGT's proven multi-element tokenization (features, type, hop, structure) with graph-native biological representations, enabling interpretable link prediction across heterogeneous entities that standard embedding models (TransE, RotatE, ComplEx) and table-based transformers cannot directly model. Achieves near-perfect performance on microbial growth media prediction (MRR: 0.9966, Precision@1: 0.9932, Hit@10: 1.0000) while maintaining explainability through attention-based reasoning over biological pathways. Training Data: - KG-Microbe merged knowledge graph: 1,379,337 nodes, 2,960,472 edges - 24 biological relation types including taxonomic hierarchies, metabolic interactions, phenotype associations, and environmental relationships - Primary prediction task: Growth media suitability for microbial taxa (biolink:occurs_in, 50K edges) - Multi-relation capability: Predicts links for any of the 24 relation types, including chemical consumption/production, phenotype associations, and taxonomic classification Citation: Original RelGT Architecture: Dwivedi et al., "Relational Graph Transformer", arXiv:2505.10960, 2025 KOGUT Implementation: Knowledge Oriented Graph Unified Transformer for Microbial Growth Media Prediction Developed at Lawrence Berkeley National Laboratory (LBNL) Trained on NERSC Perlmutter supercomputer

Joachimiak, Marcin [Lawrence Berkeley National Lab↗

Voltage Regulation Performance Evaluation of Distributed Energy Resource Management via Advanced Hardware-in-the-Loop Simulation

This paper evaluates the performance of coordinated control across advanced distribution management systems (ADMS), distributed energy resources (DERs), and distributed energy resource management systems (DERMS) using an advanced hardware-in-the-loop (HIL) platform. This platform provides a realistic laboratory testing environment, including accurate dynamic modeling of a real-world distribution system from a utility partner, real controllers (ADMS and DERMS), physical power hardware (DERs), and standard communications protocols. One grid service—voltage regulation—is evaluated to show the performance of the coordinated grid automation system. The testing results demonstrate that the coordinated DERMS and ADMS system can effectively regulate system voltages within target operation limits using DERs. The realistic laboratory HIL testing results give utilities confidence in adopting the grid automation systems to manage DERs to achieve system-level control and operation objectives (e.g., voltage regulation). This helps utilities mitigate potential risks (e.g., instability) prior to field deployment.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Modeling Summary of ASNF in DOE Sealed Standard Canisters

A pathway for road-ready and final disposition packaging configurations for the aluminum-clad spent nuclear fuel (ANSF) fuel dictates storage within helium backfilled sealed DOE standard canisters. The typical packaging configuration for the 15-foot DOE canisters places 10 advance test reactor (ATR) elements within a Type 1a basket, and three baskets are loaded within each DOE canister. During in-reactor operations and cooling pond storage conditions, oxyhydroxide layers form on the surface of the aluminum clad fuel. These layers produce hydrogen gas over time due to the fuel’s radiation field. As part of the packing procedure, the ATR fuel should be dried to remove any residual physio-/chemi- sorbed water bound to the surface. The results of this modeling will include results at fully saturated and fully dried conditions. In addition, fuels that are currently stored at the Savannah River Site were also studied for their potential for hydrogen and pressure build up. These two additional fuels modeled were the Missouri University Research Reactor (MURR) fuel, which is packaged in the same configuration as the ATR, but with a 10-foot-tall DOE standard canister. This was selected due to its relatively high decay heat compared to other DOE-managed ASNF. The second additional fuel studied with the modeling effort was the High Flux Isotope Reactor (HFIR) fuel. This fuel is modeled as two separate DOE canisters with the inner and outer annulus split for storage. The HFIR was selected for study due to its high aluminum cladding surface area. In the associated experimental work, Task 2 - Oxyhydroxide Layer Radiolytic Gas Generation Resolution, additional tests were completed in a helium environment, and updated G-values for the radiolytic production of hydrogen from the oxyhydroxide layers were provided. These values were 2.92 ×10 -4 µmol/J at 50% relative humidity and 4.12 ×10 -4 µmol/J at 100% relative humidity. These values are lower than the value for Argon that was used in prior modeling results. In addition, prior modeling results have been completed with the G-value applied to just the mass of the corrosion layer, and this has been updated to apply the G-value for hydrogen generation to the full mass of the fuel. These two effects combine to show much smaller pressure and hydrogen build up for the sealed canister model. For a nominal scenario of stored ATR fuel, after 50 years the model results give a 1.36 atm total pressure, 7% mole percent hydrogen, for the upper decay heat, 1.51 atm total pressure, 16% mole percent hydrogen, and for upper decay heat with undried fuel 2.6 atm total pressure, 15% mole percent hydrogen. For the MURR nominal case, the model results give 1.34 atm and 6% hydrogen, for upper decay heat this gives 1.41 atm total pressure with 10.8 % hydrogen, and for upper decay heat with undried fuel, this gives 2.38 atm total pressure with 9.9% hydrogen. The nominal scenario for HFIR fuel gives 1.39 atm total pressure with 9.9% hydrogen, the upper decay heat case gives 1.43 atm with 12.1% hydrogen, and the upper decay heat with undried fuel gives 2.17 atm total pressure with 11.9% hydrogen. These results confirm the ATR scenario bounds the other intact ASNF modeled here. No case modeled yields significant oxygen, and the lower decay heat cases for all fuels modeled have hydrogen concentrations that are under the 4% flammability limit after 50 years of storage. In addition, the modeled pressures for all cases are all significantly below the 500-psi limit for the DOE standard sealed canister.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Uncertainty Propagation from Experiment Measurements to Modeling Approaches: A Case for SMR Steam Entrainment Testing

To license new and advanced reactor designs, regulators must be convinced that their unique safety cases—relative to existing large scale reactors—have been adequately addressed by the designed reactor protection systems. In water cooled small modular reactors (SMRs), droplet entrainment in steam flow has significant implications on the progression of accident scenarios due to its compact design features, which requires representative test data applicable to SMR designs. Computer code, modeling and simulation (M&S) tools and models require adequate verification, assessment, and qualification. This includes M&S results validation against scaled empirical data within allowable uncertainty bands to gain regulatory approvals during the various stages of reactor system design, demonstration, and commercialization. However, measurement uncertainty within the empirical datasets and test data applicability ranges requires careful consideration of M&S inputs (i.e., boundary conditions, and initial conditions), and verification and validation efforts. This study focuses on uncertainty quantification in designing scaled test facilities for SMR applications with appropriate measurements and a standard data-reduction method to estimate thermal hydraulics characteristics parameters that incorporate physics phenomena of interest. In addition, this study supports the evaluation model development and assessment process using M&S that interfaces with advanced computing tools and digital twin capabilities. This will allow synchronization between experiment and modeling approaches for droplet entrainment testing and analysis, improving diagnostics, prognostics, and decision-making to accelerate regulatory approval.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗