Search NASA⌕ Search

SEARCH · Search NASA

Results for “statistical selection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Final Report for Industrial Base Cybersecurity Initiative (IBCI) Project (FY2019)

Information security issues impact all manufacturing sectors and are particularly troublesome when designs for advanced weapons systems are lost via attacks that propagate through the relatively unprotected lower tiers of the nation's supply chains. The US Manufacturing Industrial Base (MIB) consists of suppliers and distributors that range in size from large prime contractors with extensive cybersecurity resources to small shops with little or no in-house information technology capabilities. The acquisition and maintenance of the technologies, systems, and financial resources needed to assure secure collaborations can be an overwhelming challenge for many manufacturers yet the cost of poor cybersecurity practices can lead to the compromise of national security information worth hundreds of millions of dollars. The Department of Defense Manufacturing Industrial Base Policy organization and the Department of Energy, Energy Efficiency and Renewable Energy Advanced Manufacturing Office have chartered the Los Alamos National Laboratory (LANL) and the Oak Ridge Y-12 National Security Complex (Y-12) to design, develop, and demonstrate a Manufacturing Threat Evaluation Wargaming System (MTEWS). The MTEWS concept is based on the use of a virtual model of the computer networks and cybersecurity protocols used across the MIB that will be continuously updated to reflect the dynamic threat environment. The MTEWS cyber-physical test range will demonstrate a prototype wargaming system that analyzes the impact of new and existing cybersecurity threats while also providing the information needed to sustain the integrity of the MIB supply chains. A long-term goal is the establishment of an enduring national manufacturing operations center that proactively responds to the continuously changing attacks that threaten the MIB and US national security. LANL and Y-12 have formed an Industrial Base Cybersecurity Initiative Team (IBCI), consisting of partners from the public, private and academic sectors, that is developing the MTEWS. To date, most of the project tasks have been centered on the technologies required to create a representative model of the MIB because this is a foundational element for the entire project. Modeling activities at the University of North Carolina at Charlotte (UNC Charlotte) have demonstrated a VMware-based prototype system that can accommodate a network model with up to 350 nodes and includes features such as the option to incorporate network scanning information when building the model and the ability to down select the elements of duplicative networks to a statistically significant subset that avoids redundantly duplicating network configurations. Broad Ordering Agreements have been established with UNC Charlotte and the University of West Florida (UWF) that support a variety of cybersecurity for manufacturing tasks and wide-spread endorsement has been received from government, industry and academia sectors concerning the IBCI goals and technical direction.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Understanding Biases in Sample Preparation Techniques for Coupled Scanning Electron Microscopy and MAMA PuO 2 Morphological Analysis

In this project, the scanning electron microscopy (SEM) sampling method used during the statistical design study (SDS) was investigated to determine if any sampling biases were present in the analyzed data. Using standard particle size distribution powders from the National Institute of Standards and Technology (NIST 1984 standard reference material) with the origin wet dispersion method, it was determined that a bias to smaller particles was present. This was supported by theoretical calculations using Stokes’ law to determine the settling rate of spherical particles of roughly the same size and mass as those found in the SDS. Based on the theoretical calculations, it was determined that the settling rate for each of the 76 powder sets in the SDS could be unique based on specific particle shape and mass distributions, making a universal correction factor/formula not applicable. Therefore, priority shifted to developing an improved wet dispersion method that significantly reduced the particle settling rate for all particle size and shapes. This was achieved by replacing the original solvent (isopropyl alcohol) with a heavy liquid (lithium heteropolytungstates), which dramatically slowed the settling rate and allowed for the capture of a suitable homogeneous aliquot. SEM imaging and Morphological Analysis for Material Attribution (MAMA) software analysis were conducted on the NIST standard, and the SEM/MAMA data were compared to data captured by a dynamic image analysis particle size analyzer. The resulting data confirmed that the new wet dispersion method does indeed deliver an improved representative aliquot to the SEM stub. For instance, in the NIST certificate, the average particle size is ~17.1 µm ± 2.2 µm with a normal distribution. The initial wet dispersion method resulted in a drastically reduced average particle size of 6.1 µm in addition to a non-representative heavy bi-modal distribution whereas the improved LST wet dispersion method resulting in an average particle size that was much closer to the NIST certificate (12.7 µm) with a similar normal distribution. Although the improved method was still short of the NIST certificate average, atomic force microscopy analysis determined that the resulting ~20-25% reduction in size was due to particles sinking into the carbon sticky tape used for SEM imaging. It is believed that that this bias can be calibrated in a much more predicable manner than the original settling rate bias. In addition, the matching normal distribution curves between the NIST certificate and the heavy liquid method indicate a much-improved representative aliquot has been sampled and imaged. A surrogate CeO 2 powder was used to reflect PuO 2 more accurately and to aid in implementing radiological controls and shielding. The resulting data sets from the SEM/MAMA method and the particle size analyzer give almost identical average particle sizes and particle distribution statistics. Future work will re-analyze several select runs from the SDS to determine if morphological signatures can be found with the improved sampling method.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Optimizing the combustion synthesis of FeAlxOy catalysts for microwave-assisted thermocatalytic dehydrogenation of fossil fuels

The growing demand for hydrogen requires the development of clean and energy-efficient technologies for its synthesis. Microwave-assisted thermocatalytic dehydrogenation of fossil fuels has demonstrated the potential to produce H2 with high yield and selectivity, and simultaneously generate valuable nanostructured carbon byproducts. In prior work, iron-based alumina (FeAlxOy) catalysts for this process were made via solution combustion synthesis (SCS). However, the effect of SCS parameters on the dehydrogenation performance is not well understood. The present study investigates this by varying the SCS fuel, Fe:Al molar ratio, and heating mode. The results show subtle changes of these parameters can result in significant differences in the phase composition, specific surface area, and microwave absorbing properties of FeAlxOy, which all affect microwave-assisted dehydrogenation. Notably, H2 selectivity can be increased from 30% to 74%. Statistical testing determined that the SCS fuel used was the most significant SCS parameter affecting dehydrogenation performance.

Chanoi, Zachary A.↗

Geometry tagging for heavy ions at JLEIC

Geometry tagging is an experimental analysis technique for selecting event samples where one can, on a statistical basis, control the geometry of the collision in order to make more incisive physics measurements. Several physics measurements at the EIC would benefit significantly from the use of this technique, including studies of gluon anti-shadowing, studies of parton propagation, attenuation and hadronization in the nucleus, and ultimately the search for parton saturation. The JLEIC full-acceptance detector, with full acceptance to forward-going neutrons, protons and nuclear fragments and a high data-taking rate is ideally suited to such geometry tagging. We improve, tune, and apply existing modeling codes, BeAGLE, Sartre, and GEMC, and detector descriptions to study this physics.

Morozov, Vasiliy↗

One Galaxy Sample to Rule Them All: Halo Occupation Distribution Modeling of DES Year 3 Source Galaxies

Abstract For the joint analysis of second-order weak-lensing and galaxy clustering statistics, so-called 3 × 2 analyses, the selection and characterization of optimal galaxy samples is a major area of research. One promising choice is to use the same galaxy sample as lenses and sources, which reduces the systematics parameter space that describes the uncertainties related to galaxy samples. Such a “lens-equal-source” analysis significantly improves the self-calibration of photo- z systematics, leading to improved cosmological constraints. With the aim of enabling a lens-equal-source analysis on small scales, we investigate the halo–galaxy connection of DES Year 3 source galaxies. We develop a technique to construct mock source galaxy populations by matching COSMOS/UltraVISTA photometry to U niverse M achine galaxies. These mocks predict a source halo occupation distribution (HOD) that exhibits significant redshift evolution, nontrivial central incompleteness, and galaxy assembly bias. We produce multiple realizations of mock source galaxies drawn from the U niverse M achine posterior, with added uncertainties in the measured Dark Energy Survey photometry and galaxy shapes. We fit a modified HOD formalism to these realizations to produce priors on the galaxy–halo connection for cosmological analyses. We additionally train an emulator that predicts this HOD to ∼2% accuracy from redshift z = 0.1−1.3 that models the dependence of this HOD on (1) observational uncertainties in galaxy size and photometry and (2) uncertainties in the U niverse M achine predictions.

Salcedo, Andrés N. (ORCID:000000031420527X)↗

The Chocolate Chip Cookie Model: Dust-to-metal Ratio of H ii Regions

Using a sample of face-on star-forming galaxies selected from the Sloan Digital Sky Survey, we statistically derive the typical optical depth $\tau$ cl of individual H II regions based on the "Chocolate Chip Cookie" model of Lu et al. (2022). By binning galaxies into stellar mass and gas-phase metallicity bins and interpreting $\tau$ cl as the dust-to-gas ratio (DGR) of H II regions, we further investigate the correlations between DGR and stellar mass and between DGR and gas-phase metallicity, respectively. We find that DGR increases monotonically with the stellar mass of galaxies. At a given stellar mass, DGR shows a linear correlation with the gas-phase metallicity, which implies a constant dust-to-metal ratio (DTM) of galaxies at a given stellar mass. These results adequately indicate that the DTM of galaxies is simply a function of their stellar masses. In terms of gas-phase metallicity, because of the mass–metallicity relation, DTM increases with increasing metallicity with a power-law index 1.45 in the low-metallicity region, while it remains constant at the high-metallicity end.

79 ASTRONOMY AND ASTROPHYSICS↗

Mass Spectrometry Adduct Calculator

We describe the Mass Spectrometry Adduct Calculator (MSAC), an automated Python tool to calculate the adduct ion masses of a parent molecule. Here, adduct refers to a version of a parent molecule [M] that is charged due to addition or loss of atoms and electrons resulting in a charged ion, e.g. [M+H] + . MSAC includes a database of 2,341 potential ions and their mass-to-charge ratios (m/z) as extracted from the NIST/EPA/NIH Mass Spectral Library (NIST17), the Global Natural Products Social Molecular Networking Public Spectral Libraries (GNPS), and MassBank of North America (MoNA). The calculator relies on user-selected subsets of the combined database to calculate expected m/z for adducts of molecules supplied as formulas This tool is intended to help researchers create identification libraries to collect evidence for the presence of molecules in mass spectrometry data. While the included adduct database focuses on adducts typically detected during liquid chromatography-mass spectrometry analyses, users may supply their own lists of adducts and charge states for calculating expected m/z. We also analyzed statistics on adducts from spectra contained in the three selected mass spectral libraries. MSAC is freely available at https://github.com/pnnl/MSAC.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Identifying Important Ions and Positions in Mass Spectrometry Imaging Data Using CUR Matrix Decompositions

Mass spectrometry imaging enables label-free, high-resolution spatial mapping of the chemical composition of complex, biological samples. Typical experiments require selecting ions and/or positions from the images: ions for fragmentation studies to identify keystone compounds and positions for follow up validation measurements using microdissection or other orthogonal techniques. Unfortunately, with modern imaging machines, these must be selected from an overwhelming amount of raw data. Existing techniques to reduce the volume of data, the most popular of which are principle component analysis and non-negative matrix factorization, have the disadvantage that they return difficult-to-interpret linear combinations of actual data elements. In this work, we show that CX and CUR matrix decompositions can be used directly to address this selection need. CX and CUR matrix decompositions use empirical statistical leverage scores of the input data to provide provably good low-rank approximations of the measured data that are expressed in terms of actual ions and actual positions, as opposed to difficult-to-interpret eigenions and eigenpositions. We show that this leads to effective prioritization of information for both ions and positions. In particular, important ions can be found either by using the leverage scores as a ranking function and using a deterministic greedy selection algorithm or by using the leverage scores as an importance sampling distribution and using a random sampling algorithm; however, selection of important positions from the original matrix performed significantly better when they were chosen with the random sampling algorithm. Also, we show that 20 ions or 40 locations can be used to reconstruct the original matrix to a tolerance of 17% error for a widely studied image of brain lipids; and we provide a scalable implementation of this method that is applicable for analysis of the raw data where there are often more than a million rows and/or columns, which is larger than SVD-based low-rank approximation methods can handle. Lastly, these results introduce the concept of CX/CUR matrix factorizations to mass spectrometry imaging, describing their utility and illustrating principled algorithmic approaches to deal with the overwhelming amount of data generated by modern mass spectrometry imaging.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

International collaboration framework for the calculation of performance loss rates: Data quality, benchmarks, and trends (towards a uniform methodology)

Abstract The IEA PVPS Task 13 group, experts who focus on photovoltaic performance, operation, and reliability from several leading R&D centers, universities, and industrial companies, is developing a framework for the calculation of performance loss rates of a large number of commercial and research photovoltaic (PV) power plants and their related weather data coming across various climatic zones. The general steps to calculate the performance loss rate are (i) input data cleaning and grading; (ii) data filtering; (iii) performance metric selection, corrections, and aggregation; and finally, (iv) application of a statistical modeling method to determine the performance loss rate value. In this study, several high‐quality power and irradiance datasets have been shared, and the participants of the study were asked to calculate the performance loss rate of each individual system using their preferred methodologies. The data are used for benchmarking activities and to define capabilities and uncertainties of all the various methods. The combination of data filtering, metrics (performance ratio or power based), and statistical modeling methods are benchmarked in terms of (i) their deviation from the average value and (ii) their uncertainty, standard error, and confidence intervals. It was observed that careful data filtering is an essential foundation for reliable performance loss rate calculations. Furthermore, the selection of the calculation steps filter/metric/statistical method is highly dependent on one another, and the steps should not be assessed individually.

14 SOLAR ENERGY↗

Reliability of diagnostic methods based on low-frequency noise analysis

Various methods for separating an integrated circuit (IC) batch were considered using noise parameters for the purpose of determining their reliability. The existing methods for screening semiconductor products using low-frequency (LF) noise were tested on transistors, as well as both digital and analog ICs, and showed good results. Selection criteria for semiconductor products were determined based on the statistics of a representative sample; however, their reliability was not estimated. The calculation of the correlation coefficient of determined LF noise parameters and reference reliability testing results was taken as the basis of the determination of reliability of diagnostic methods. For the experiment, KR142EN5A ICs made by bipolar technology were selected, which represent three-pin stabilizers with a fixed output voltage from 5 V and are used in many radio-electronic devices.

36 MATERIALS SCIENCE↗

The SDSS-IV MaNGA Sample: Design, Optimization, and Usage Considerations

We describe the sample design for the SDSS-IV MaNGA survey and present the final properties of the main samples along with important considerations for using these samples for science. Our target selection criteria were developed while simultaneously optimizing the size distribution of the MaNGA integral field units (IFUs), the IFU allocation strategy, and the target density to produce a survey defined in terms of maximizing signal-to-noise ratio, spatial resolution, and sample size. Our selection strategy makes use of redshift limits that only depend on i-band absolute magnitude (M {sub i}), or, for a small subset of our sample, M {sub i} and color (NUV − i). Such a strategy ensures that all galaxies span the same range in angular size irrespective of luminosity and are therefore covered evenly by the adopted range of IFU sizes. We define three samples: the Primary and Secondary samples are selected to have a flat number density with respect to M {sub i} and are targeted to have spectroscopic coverage to 1.5 and 2.5 effective radii (R {sub e}), respectively. The Color-Enhanced supplement increases the number of galaxies in the low-density regions of color–magnitude space by extending the redshift limits of the Primary sample in the appropriate color bins. The samples cover the stellar mass range 5×10{sup 8}⩽M{sub ∗}⩽3×10{sup 11} M{sub ⊙} h{sup −2} and are sampled at median physical resolutions of 1.37 and 2.5 kpc for the Primary and Secondary samples, respectively. We provide weights that will statistically correct for our luminosity and color-dependent selection function and IFU allocation strategy, thus correcting the observed sample to a volume-limited sample.

79 ASTRONOMY AND ASTROPHYSICS↗

pyFLANK, a graph neural network based null distribution inference model for F ST outlier detection

Detecting genomic regions under selection is essential for understanding how populations adapt to different environments, yet it remains challenging due to the confounding effects of demographic history and linkage disequilibrium (LD). Fixation index (F ST ) is a widely used statistic to identify genomic regions under adaptation. However, identifying genes under selection by defining F ST outliers often remains challenging, owing to confounding effects of underlying demographic history. Traditional methods assume independence among loci and rely on simple demographic models, while newer models perform much better but are computationally expensive and not easily scalable. Here, we present pyFLANK, an open-source and automated Python implementation which detects F ST outliers using a null distribution inferred from quasi-independent loci. Our tool integrates three approaches to identify loci obeying a null distribution: graph neural network (GNN) inference, linkage disequilibrium (LD)-based inference, and user-defined input. Because pyFLANK uses GNN-based inference of quasi-independent loci, it yields a more accurate null model with less need for user parameter input. In simulation experiments, pyFLANK achieved lower false positive rates than current methods while maintaining comparable detection power, indicating that its refined null model better distinguishes true adaptive loci from background variation. The GNN-based model, in particular, detected additional loci associated with phenotypic variance that were not identified by existing methods. Assessments of simulation and real data from different species demonstrate that pyFLANK achieves lower false positive rates compared with other commonly used F ST outlier detectors, while maintaining comparable detection power and excellent computational performance, providing a robust and user-friendly tool for identifying loci under divergent selection. It extends existing F ST outlier frameworks by incorporating explicit LD-aware strategies for null model calibration. The method is intended as a practical and scalable complement to existing genome scan approaches.

FST↗

THE IMPACT OF CLUSTER STRUCTURE AND DYNAMICAL STATE ON SCATTER IN THE SUNYAEV-ZEL'DOVICH FLUX-MASS RELATION

Cosmological constraints from cluster surveys rely on accurate mass estimates from the mass-observable relations. In order to avoid systematic biases and reduce uncertainties, we study the form and physical origin of the intrinsic scatter about the mean Sunyaev-Zel'dovich (SZ) flux-mass relation using a hydrodynamical simulation of galaxy cluster formation. We examine the assumption of lognormal scatter and detect non-negligible positive skewness and kurtosis (>0.5) for a wide range of limiting masses and redshifts. These higher order moments should be included in the parameterization of scatter in order not to bias cosmological constraints. We investigate the sources of the scatter by correlating it with measures of cluster morphology, halo concentration, and dynamical state, and quantify the individual contribution from each source. We find that statistically the impact of the dynamical state is weak, so the selection bias due to mergers is negligible. On the other hand, there is a strong correlation between the scatter and halo concentration, which can be used to reduce the scatter significantly (from 12.07% to 7.34% or by {approx}40% for clusters at z = 0). We also show that a cross-calibration by combining information from X-ray follow-ups can be used to reduce the scatter in the flux-mass relation and also identify outliers in both X-ray and SZ cluster surveys.

79 ASTRONOMY AND ASTROPHYSICS↗

Statistical Assessment of Proton Treatment Plans Under Setup and Range Uncertainties

Purpose: To evaluate a method for quantifying the effect of setup errors and range uncertainties on dose distribution and dose–volume histogram using statistical parameters; and to assess existing planning practice in selected treatment sites under setup and range uncertainties. Methods and Materials: Twenty passively scattered proton lung cancer plans, 10 prostate, and 1 brain cancer scanning-beam proton plan(s) were analyzed. To account for the dose under uncertainties, we performed a comprehensive simulation in which the dose was recalculated 600 times per given plan under the influence of random and systematic setup errors and proton range errors. On the basis of simulation results, we determined the probability of dose variations and calculated the expected values and standard deviations of dose–volume histograms. The uncertainties in dose were spatially visualized on the planning CT as a probability map of failure to target coverage or overdose of critical structures. Results: The expected value of target coverage under the uncertainties was consistently lower than that of the nominal value determined from the clinical target volume coverage without setup error or range uncertainty, with a mean difference of −1.1% (−0.9% for breath-hold), −0.3%, and −2.2% for lung, prostate, and a brain cases, respectively. The organs with most sensitive dose under uncertainties were esophagus and spinal cord for lung, rectum for prostate, and brain stem for brain cancer. Conclusions: A clinically feasible robustness plan analysis tool based on direct dose calculation and statistical simulation has been developed. Both the expectation value and standard deviation are useful to evaluate the impact of uncertainties. The existing proton beam planning method used in this institution seems to be adequate in terms of target coverage. However, structures that are small in volume or located near the target area showed greater sensitivity to uncertainties.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Use-Inspired, Process-Oriented GCM Selection: Prioritizing Models for Regional Dynamical Downscaling

Dynamical downscaling is a crucial process for providing regional climate information for broad uses, using coarser-resolution global models to drive higher-resolution regional climate simulations. The pool of global climate models (GCMs) providing the fields needed for dynamical downscaling has increased from the previous generations of the Coupled Model Intercomparison Project (CMIP). However, with limited computational resources, the need for prioritizing the GCMs for subsequent downscaling studies remains. GCM selection for dynamical downscaling should focus on evaluating processes relevant for providing boundary conditions to the regional models and be inspired by regional uses such as the response of extremes to changes in the boundary conditions. This leads to the need for metrics representing processes of relevance to diverse stakeholders and subregions of a domain. Procedures to account for metric redundancy and the statistical distinguishability of GCM rankings are required. Further, procedures for selecting realizations from ensembles of top-performing GCM simulations can be used to span the range of climate change signals in multiple ways. As a result, distinct weighting of metrics and prioritization of particular realizations may depend on user needs. We provide high-level guidelines for such region-specific evaluations and address how CMIP7 might enable dynamical downscaling of a representative sample of high-quality models across representative shared socioeconomic pathways (SSPs).

54 ENVIRONMENTAL SCIENCES↗

SU-D-BRD-07: Evaluation of the Effectiveness of Statistical Process Control Methods to Detect Systematic Errors For Routine Electron Energy Verification

Purpose: To evaluate the ability of statistical process control methods to detect systematic errors when using a two dimensional (2D) detector array for routine electron beam energy verification. Methods: Electron beam energy constancy was measured using an aluminum wedge and a 2D diode array on four linear accelerators. Process control limits were established. Measurements were recorded in control charts and compared with both calculated process control limits and TG-142 recommended specification limits. The data was tested for normality, process capability and process acceptability. Additional measurements were recorded while systematic errors were intentionally introduced. Systematic errors included shifts in the alignment of the wedge, incorrect orientation of the wedge, and incorrect array calibration. Results: Control limits calculated for each beam were smaller than the recommended specification limits. Process capability and process acceptability ratios were greater than one in all cases. All data was normally distributed. Shifts in the alignment of the wedge were most apparent for low energies. The smallest shift (0.5 mm) was detectable using process control limits in some cases, while the largest shift (2 mm) was detectable using specification limits in only one case. The wedge orientation tested did not affect the measurements as this did not affect the thickness of aluminum over the detectors of interest. Array calibration dependence varied with energy and selected array calibration. 6 MeV was the least sensitive to array calibration selection while 16 MeV was the most sensitive. Conclusion: Statistical process control methods demonstrated that the data distribution was normally distributed, the process was capable of meeting specifications, and that the process was centered within the specification limits. Though not all systematic errors were distinguishable from random errors, process control limits increased the ability to detect systematic errors using routine measurement of electron beam energy constancy.

07 ISOTOPE AND RADIATION SOURCES↗

Optimal binning of correlated measurements

Experimental measurements are commonly represented on a discrete grid, requiring a balance between granularity and statistical noise. Two strategies have traditionally been used to improve such representations: selecting an appropriate bin width to control discretization error and applying kernel-based smoothing to suppress fluctuations. Despite their shared goal, these approaches have largely developed independently, without a unified statistical description of how discretization and correlation jointly determine measurement precision. Here, we extend the discussion of optimal interval averaging to a correlation-aware setting by Gaussian process regression, which explicitly accounts for correlations among neighboring bins. Starting from first principles, we derive the mean-squared error of discretized measurements and obtain closed-form asymptotic expressions for the optimal bin width and correlation length. When recast in reduced variables, the theory reveals distinct universal scaling laws governing the error in the correlation-free and correlation-controlled regimes. Characterized by intrinsically smooth intensity profiles and counting-based statistics, neutron scattering measurements are well suited for demonstrating the enhanced error contraction enabled by inter-bin correlations. We show that such improvement is achievable over the experimentally accessible Q-range and across multiple instruments and material systems. These results show that explicitly accounting for correlations systematically reshapes the limits of precision in discretized, noise-limited measurements. More broadly, the framework provides a transferable statistical foundation for optimizing data representation, inference, and experimental design across the physical and data sciences.

Tung, Chi-Huan [ORNL] (ORCID:0000000221972074)↗

Long-term stability-degradation analysis of DUNE SiPMs in Liquid Nitrogen

We developed a cryogenic photon readout system to monitor arrays of DUNE SiPMs operating at various over-voltages in liquid nitrogen (LN2) for over three months. Photoelectron signals were read out simultaneously via weak capacitive coupling to the micro-FEMB, a 32-channel charge sensitive readout board designed for 77 K to 300 K operation in liquid argon time projection chambers (LAr-TPCs). A waveform snippet acquisition scheme was implemented to capture waveform signals whenever they exceeded a predetermined trigger level; consequently, empty waveforms were discarded. Selected SiPM parameters were monitored to detect any deviations beyond statistical fluctuations. While some parameters exhibited ~1σ variations over the 3-month test period, there was no evidence of drift being enhanced when operating at 4 V or 5 V compared to a 3 V over-voltage. However, a discernible PDE drop was observed across all channels, which warrants further investigation. In addition, we demonstrated that our system can simultaneously read out single photons from a selected group of SiPMs at room temperature.

Tsang, Thomas [Brookhaven]↗