Search NASA⌕ Search

SEARCH · Search NASA

Results for “structural mount”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Solid state lighting devices and methods with rotary cooling structures

Solid state lighting devices and methods for heat dissipation with rotary cooling structures are described. An example solid state lighting device includes a solid state light source, a rotating heat transfer structure in thermal contact with the solid state light source, and a mounting assembly having a stationary portion. The mounting assembly may be rotatably coupled to the heat transfer structure such that at least a portion of the mounting assembly remains stationary while the heat transfer structure is rotating. Examples of methods for dissipating heat from electrical devices, such as solid state lighting sources are also described. Heat dissipation methods may include providing electrical power to a solid state light source mounted to and in thermal contact with a heat transfer structure, and rotating the heat transfer structure through a surrounding medium.

36 MATERIALS SCIENCE↗

Cylindrical surface profile and diameter measuring tool and method

A tool is shown having a cross beam assembly made of beams joined by a center box structure. The assembly is adapted to be mounted by brackets to the outer end of a cylindrical case. The center box structure has a vertical shaft rotatably mounted therein and extending beneath the assembly. Secured to the vertical shaft is a radius arm which is adapted to rotate with the shaft. On the longer end of the radius arm is a measuring tip which contacts the cylindrical surface to be measured and which provides an electric signal representing the radius of the cylindrical surface from the center of rotation of the radius arm. An electric servomotor rotates the vertical shaft and an electronic resolver provides an electric signal representing the angle of rotation of the shaft. The electric signals are provided to a computer station which has software for its computer to calculate and print out the continuous circumference profile of the cylindrical surface, and give its true diameter and the deviations from the ideal circle.

Currie, James R.↗

A stereo triangulation system for structural identification: Analytical and experimental results

Identification of large space structures' distributed mass, stiffness, and energy dissipation characteristics poses formidable analytical, numerical, and implementation difficulties. Development of reliable on-orbit structural identification methods is important for implementing active vibration suppression concepts which are under widespread study in the large space structures community. Near the heart of the identification problem lies the necessity of making a large number of spatially distributed measurements of the structure's vibratory response and the associated force/moment inputs with sufficient spatial and frequency resolution. In the present paper, we discuss a method whereby tens of active or passive (retro-reflecting) targets on the structure are tracked simultaneously by the focal planes of two or more video cameras mounted on an adjacent platform. Triangulation (optical ray intersection) of the conjugate image centroids yield inertial trajectories of each target on the structure. Given the triangulated motion of the targets, we apply and extend methodology developed by Creamer, Junkins, and Juang to identify the frequencies, mode shapes, and updated estimates for the mass/stiffness/damping parameterization of the structure. The methodology is semi-automated, for example, the post experiment analysis of the video imagery to determine the inertial trajectories of the targets typically requires less than thirty minutes of real time. Using methodology discussed herein, the frequency response of a large number of points on the structure (where reflective targets are mounted) on the structure can be determined from optical measurements alone. For comparison purposes, we also utilize measurements from accelerometers and a calibrated impulse hammer. While our experimental work remains in a research stage of development, we have successfully tracked and stereo triangulated 20 targets (on a vibrating cantilevered grid structure) at a sample frequency of 200 HZ, and have established conclusively the feasibility and desirability of this approach. We discuss, in summary, recent advances in analog and digital video processing methodology, actuation methods, and bring them to bear on the structural identification problem. We include a brief discussion of our experimental hardware and some recent experimental results which support the practical feasibility of this structural vibration sensing approach.

Junkins, J. L.↗

Simultaneous measurement of temperature and strain by cascaded fiber Bragg grating-silicon Fabry-Perot interferometer sensor

We report a fiber-optic sensor configuration with a cascaded fiber Bragg grating (FBG) and a silicon Fabry-Perot interferometer (FPI) for simultaneous measurement of temperature and strain. The sensor is composed of a 5 mm FBG on a single mode fiber and a 100μm thick silicon FPI attached to the tip of the optical fiber. The FBG is surface mounted on the host structure, and the FPI tip is suspended. Due to the stress-free, cantilever configuration, the silicon FPI is insensitive to strain, but sensitive to temperature with a sensitivity much higher than the FBG due to the large thermo-optic coefficient of silicon. The sensor is tested from room temperature to 100°C with varying strain up to ∼150με. The silicon FPI provides high temperature sensitivity of 89 pm/°C unaffected by strain. Since the FBG is attached to the host structure, it is affected by both thermal and mechanical strain; the sensitivity of these was experimentally obtained 32 pm/°C and 1.09 pm / με, respectively. Interrogated with a broadband light source and a high-speed spectrometer, the sensor shows temperature and strain resolutions of 1.9 × 10 −3 °C and 0.042 με, respectively. Here, due to the small size, enhanced sensitivity, and high resolution, this cascaded FBG-FPI sensor can be used in applications where accurate measurement of temperature and strain is required.

42 ENGINEERING↗

Extraction of Vibration Data with Imaging

To date, the primary sensing technology used to measure the vibration response has been accelerometers and strain gages mounted directly to the structure and using either wired or, more recently, wireless telemetry. Cost issues with these sensors and the associated data acquisition systems typically limit the numbers that are deployed on in situ structures. Although there are a few structures with larger sensing counts that in some cases exceed over 1000 sensors, more typical numbers range from ten to one hundred sensors resulting in low spatial resolution when they are applied to physically large systems. When one considers that nuclear power plant structures usually have complex geometries, material properties, connectivity and boundary conditions, it is clear these current approaches to vibration measurements can only provide limited information about a system’s dynamics response characteristics. As an alternative, many non-contact measurement technologies have emerged, including point wise measurement methods such as Global Positioning System (GPS), microwave interferometry, and laser Doppler vibrometry (LDV), as well as simultaneous full-field measurement methods such as electronic speckle pattern interferometry, holography interferometry, and muon tomography, some of which can provide high spatial resolution measurements. Among these methods, digital video imaging techniques have emerged as a feasible solution for full-field vibration measurements that provide significantly more detailed dynamic response information because every pixel becomes a measurement point. Furthermore, recent advances in image processing and computer vision algorithms have been successfully used to process video data for experimental and operational modal analysis. Such full-field measurements have the potential to significantly improve many current structural assessment procedures including system identification (modal parameter estimation), structural health monitoring, load reconstruction, model validation, and model updating. Furthermore, more recent full-field imaging techniques can be accomplished with relatively low-cost, commercially-available off-the-shelf cameras. However, these measurement procedures have other limitations that must be considered such as the ability to only measure visibly accessible points on a structure and a more limited dynamic range and bandwidth than can be achieved with accelerometers or strain gages.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

COMBLE-ISLAS water isotopes in precipitation (COMBLEISLASISO)

During the measurement period, precipitation was sampled on daily to sub-daily basis with a sampling kit consiting of a clear plastic box (60x40x40 cm) mounted to a ground structure. Daily sampling lasted from 22 Feb to 24 Mar 2020. At a fixed time of day (10 UTC), samples were collected and the sampling box cleaned for the next sample. Additionally, during intense observations periods (IOPs) announced by ISLAS, ARMS scientists increased sampling frequency to sub-daily sampling. During the campaign period, 2 IOPs were conducted, with in total 12 samples taken. IOP1 lasted from 27 Feb 10 to 02 Mar 2020, and IOP2 lasted from 12 Mar to 14 Mar 2020. Solid precipitation in the box was then melted, transferred to an 8 ml glass vial, sealed and shipped to FARLAB (University of Bergen, Norway) for stable water isotope analysis. Measured stable isotope composition of precipitation samples will be related to conditions at other sampling locations, and at the evaporation site to inform about conservation of water isotope quantities. In the period from 22 Feb to 24 Mar, 23 daily samples were collected at 10 UTC for stable water isotope analysis. During the entire sampling period, a high variability of precipitation phase was encountered. Most samples were recovered in the form of graupel/snow (12 samples), as rain (7 samples), and the remaining samples fell as graupel, snow, rain or frozen rain. Precipitation amounts varied between <1 mm (26 Feb) and 140 mm (25 Feb) within the sampling box. Furthermore, higher-resolution sampling was conducted during 2 intense observation periods (IOPs). During IOP1, lasting from 27 Feb 10 UTC to 02 Mar 10 UTC, 7 samples were collected, all of them as solid phase precipitation. IOP2 lasted from 12 Mar 10 UTC to 14 Mar 09 UTC, and 5 samples (all as graupel/snow) were collected. Samples were processed according to FARLAB standard measurement procedures. In short, samples were transferred to 1.5 ml glass vials with rubber/PTFE septa (part #548-0907, VWR, USA). An autosampler (A0325, Picarro Inc) transferred ca. 2&micro;l per injection into a high-precision vapourizer (A0211, Picarro Inc, USA) heated to 110&deg;C. After blending with dry N2 (< 5 ppm H2O) the gas mixture was directed into the measurement cavity of a Cavity-Ring Down Spectrometer (L2140-i, Picarro Inc) for about 7 min with a typical water concentration of 20 000 ppm. Memory effects were reduced by two times measuring a vapour mixture at a mixing ratio of 50 000 ppm, obtained from 2 injections of 2 &micro;l for 5 min at the beginning of each new sample vial. Thereafter, another 6 injections of 2 &micro;l per sample were measured individually as described above, and averages of the last 5 injections were used for further processing. Three standards were measured at the beginning and end of each batch, including a drift standard DI2 (&delta;D: -50.72&plusmn;0.73 permil, &delta;18O: -7.63&plusmn;0.10 permil), and for calibration the laboratory standards GLW (&delta;D: -307.79&plusmn;0.75 permil, &delta;18O: -40.02&plusmn;0.07 permil) and EVAP2 (&delta;D: 9.52&plusmn;0.65 permil, &delta;18O: 1.81&plusmn;0.13 permil). A detailed calibration report is included with the final uploaded data set.

54 ENVIRONMENTAL SCIENCES↗

Fabrication of electroacoustic RF amplifiers

Anodic bonding of a lithium niobate piezoelectric crystal over a silicon-on-sapphire structure with the crystal mounted over a closely controlled oxide provides a point-contact mount for two rectangular slabs /one piezoelectric and the other a silicon semiconductor/ within 600 A of each other.

Trent, R. L.↗

Design and construction of prototype radio antenna for shortest radio wavelengths

A paraboloid radio antenna of 10.4 meters diameter, 0.41 meter focal length was constructed and its successful completion is described. The surface accuracy of the antenna is at least four times better than any existing antenna in its class size (50 micrometers rms). Antenna design specifications (i.e., for mounting, drive motors, honeycomb structures) are discussed and engineering drawings and photographs of antenna components are shown. The antenna will be used for millimeter-wave interferometry and sub-millimeter wave radiometry over a full frequency range (up to approximately 860 GHz). The antenna will also be moveable (for interferometric use) between reinforced concrete pads by rail. The effects of the weather and gravity on antenna performance are briefly discussed.

Leighton, R. B.↗

An underwater work systems package

A modular unit which is adaptable to several existing deep sea submersibles was developed to extend their working abilities and acquire knowledge of components and techniques for working in the deep sea environment. This work systems package is composed of an aluminum pipe structure on which are mounted two six-function grabber arms, a seven function manipulator, tool suit, 1,000/lb. capacity winch, electrohydraulic power supply, electronics housing, lights, and television. The unit is designed to be operated by itself either remotely or with divers, attached to manned submersibles, or mounted on unmanned cable-controlled submersibles.

Estabrook, N. B.↗

MSFC presentation charts on geostationary platform

A concept is presented of a geostationary platform. The concept takes the form of antennas and other payloads mounted on a strongback structure. The utilization and benefits of the platform are discussed.

Carey, W. T., Jr.↗

An operating 200-kW horizontal axis wind turbine

The Mod-OA wind turbine blades were rotated for the first time on November 30, 1977, establishing the Mod-OA as the first wind-driven generator in 35 years to be continually tied into an electrical power system which services a community. Tower-mounted equipment and blade structural design and fabrication are discussed.

Hunnicutt, C. L.↗

municipal recreation center is heated and cooled by solar energy

Major fraction of energy requirements for community building is ksupplied by Sun. The 238 flat plate solar collectors are roof mounted on single story structure enclosing gymnasium, locker area, and health care clinic; heat exchanger transfers collected energy to 6,000 gallon storage tank. Final report chronicles project from inception to completion, documenting performance, costs, operating modes, and data acquisition system. Appendix contains manufacturers' product literature and engineering drawings.

Source record↗

HCMM imagery for the discrimination of rock types, the detection of geothermal energy sources and the assessment of soil moisture content in western Queensland and adjacent parts of New South Wales and South Australia

The author has identified the following significant results. Day-visible and day-IR imagery of northwest Queensland show that large scale geological features like the Mitakoodi anticlinorium, which involves rocks of contrasting lithological type, can be delineated. North of Cloncurry, the contrasting lithological units of the Knapdale quartzite and bedded argillaceous limestones within the Proterozoic Corella sequence are clearly delineated in the area of the Dugald River Lode. Major structural features in the Mount Isa area are revealed on the day-visible cover. Which provides similar but less detailed information than the LANDSAT imagery. The day-IR cover provides less additional information for areas of outcropping bedrock than had been expected. Initial studies of the day-IR and night-IR cover for parts of South Australia suggest that they contain additional information on geology compared with day-visible cover.

Cole, M. M.↗

Command profile for Galileo scan platform control

A recursive command profile is developed for the control of a two-degree-of-freedom scan platform mounted on a flexible structure. Perfect sensors and actuators are assumed for development and testing, and structural vibrations are minimized by actuator torque commands following a smooth torque-time profile. The integral of the smooth torque profile, the rate profile, is recursively generated by a piecewise constant second derivation, and the torque applied by the closk actuator is divided into three components. Results show that the smooth platform motion in response to the command profiles is what the Galileo control systems needs to avoid stator structural vibrations. Position, rate and acceleration profiles are also presented, and the resulting motion of the scan platform in response to command profiles is illustrated.

Man, G. K.↗

Introduction to Long-Duration Exposure Facility

A description of the structure and uses of the Long Duration Exposure Facility (LDEF) is given. The LDEF was designed to provide a large number of economical opportunities for science and technology experiments that require modest electrical power and data processing while in space and which benefit from postflight laboratory investigations with the retrieved experiment hardware. Like the Shuttle, the LDEF is reusable, and repeat missions are planned, each with a new complement of experiments. The LDEF is essentially a free-flying cylindrical structure. The experiments on LDEF are totally self-contained in trays mounted on the exterior of the structure. LDEF can accommodate 86 experiment trays, 72 around the circumference and 14 on the two ends. The LDEF is delivered to Earth orbit by the Shuttle. In orbit, the Shuttle remote manipulator system removes the LDEF from the Shuttle payload bay and places it in a gravity-gradient-stabilized attitude. After an extended period in orbit, which is set by experiment requirements, the LDEF is retrieved on a subsequent Shuttle flight.

Kinard, W. H.↗

The Orbiter camera payload system's large-format camera and attitude reference system

The Orbiter camera payload system (OCPS) is an integrated photographic system carried into earth orbit as a payload in the Space Transportation System (STS) Orbiter vehicle's cargo bay. The major component of the OCPS is a large-format camera (LFC), a precision wide-angle cartographic instrument capable of producing high-resolution stereophotography of great geometric fidelity in multiple base-to-height ratios. A secondary and supporting system to the LFC is the attitude reference system (ARS), a dual-lens stellar camera array (SCA) and camera support structure. The SCA is a 70 mm film system that is rigidly mounted to the LFC lens support structure and, through the simultaneous acquisition of two star fields with each earth viewing LFC frame, makes it possible to precisely determine the pointing of the LFC optical axis with reference to the earth nadir point. Other components complete the current OCPS configuration as a high-precision cartographic data acquisition system. The primary design objective for the OCPS was to maximize system performance characteristics while maintaining a high level of reliability compatible with rocket launch conditions and the on-orbit environment. The full OCPS configuration was launched on a highly successful maiden voyage aboard the STS Orbiter vehicle Challenger on Oct. 5, 1984, as a major payload aboard the STS-41G mission.

Schardt, B. B.↗

Mission Report on the Orbiter Camera Payload System (OCPS) Large Format Camera (LFC) and Attitude Reference System (ARS)

The Orbiter Camera Payload System (OCPS) is an integrated photographic system which is carried into earth orbit as a payload in the Space Transportation System (STS) Orbiter vehicle's cargo bay. The major component of the OCPS is a Large Format Camera (LFC), a precision wide-angle cartographic instrument that is capable of producing high resolution stereo photography of great geometric fidelity in multiple base-to-height (B/H) ratios. A secondary, supporting system to the LFC is the Attitude Reference System (ARS), which is a dual lens Stellar Camera Array (SCA) and camera support structure. The SCA is a 70-mm film system which is rigidly mounted to the LFC lens support structure and which, through the simultaneous acquisition of two star fields with each earth-viewing LFC frame, makes it possible to determine precisely the pointing of the LFC optical axis with reference to the earth nadir point. Other components complete the current OCPS configuration as a high precision cartographic data acquisition system. The primary design objective for the OCPS was to maximize system performance characteristics while maintaining a high level of reliability compatible with Shuttle launch conditions and the on-orbit environment. The full-up OCPS configuration was launched on a highly successful maiden voyage aboard the STS Orbiter vehicle Challenger on October 5, 1984, as a major payload aboard mission STS 41-G. This report documents the system design, the ground testing, the flight configuration, and an analysis of the results obtained during the Challenger mission STS 41-G.

Mollberg, Bernard H.↗

Liquid booster engine reuse - A recovery system

The paper presents the design of a recovery system for a suborbital payload of an Atlas E rocket. This program utilizes off-the-shelf and previously qualified avionics, flotation, and decelerator systems. A brief history of liquid-engine recoveries is presented first, then the system design utilizing two self-contained structurally-identical pods diametrically mounted to the thrust section is outlined. A mortar-deployed drogue and the main parachute are described, and experimental procedures are considered. Data obtained from one tricluster drop employing a cylindrical test vehicle and helicopter is analyzed, and a satisfactory load balance between the parachutes is observed.

Von Eckroth, Wulf↗