Search NASA⌕ Search

SEARCH · Search NASA

Results for “targeted quantification”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Targeted Metabolomics of the Phenylpropanoid Pathway in Arabidopsis thaliana using Reversed Phase Liquid Chromatography Coupled with Tandem Mass Spectrometry: Measuring Lignin Precursors by LC-MS

The phenylpropanoid pathway is a source of a diverse group of compounds derived from phenylalanine, many of which are involved in lignin biosynthesis and serve as precursors for the production of valuable compounds, such as coumarins, flavonoids, and lignans. Consequently, recent efforts have been invested in mechanistically understanding monolignol biosynthesis, making the quantification of these metabolites vital. To develop an improved and comprehensive analytical method for (i) extensively profiling, and (ii) accurately quantifiying intermediates of the monolignol biosynthetic network, using Arabidopsis thaliana as a model system. A liquid chromatography-tandem mass spectrometry with electrospray ionization was developed to quantify phenylpropanoid metabolites in Arabidopsis wildtype and cinnamoyl CoA reductase1 (CCR1) deficient lines (ccr1). Vortexing at high temperatures (65°C) enhanced release of phenylpropanoids, specifically the more hydrophobic compounds. A pH of 5.3 and ammonium acetate buffer concentration of 2.5 mM resulted in an optimal analyte response across standards. Ion suppression was estimated using standard spike recovery studies for accurate quantitation. The optimized method was used to profile Arabidopsis wildtype and ccr1 stems. An increase in hydroxycinnamic acid derivatives and a decrease in the hydroxycinnamyl aldehydes and alcohols in ccr1 lines, supports a shift of flux from lignin synthesis to other secondary metabolites and phenylpropanoid derivatives. Compared to existing targeted profiling techniques, our method is capable of quantifying a wider range of intermediates (15 out of 22 in WT Arabidopsis stems) at low in vivo concentrations (~50 pmol/g-FW for certain compounds), while requiring minimal sample preparation.

09 BIOMASS FUELS↗

Quantification of Motion of Different Thoracic Locations Using Four-Dimensional Computed Tomography: Implications for Radiotherapy Planning

Purpose: To assess the respiratory motion of different thoracic nodal locations and its dependence on the presence of enlarged nodes; to assess the respiratory motion of different parenchymal tumor locations; and to determine the appropriate margins to cover the respiratory motion of targets at these locations. Methods and Materials: We reviewed the four-dimensional computed tomography scans of 20 patients with thoracic tumors treated at our institution. The motion of four central thoracic locations (aortic arch, carina, and bilateral hila), parenchymal tumor locations (upper vs. lower, and anterior vs. middle vs. posterior thorax), and bilateral diaphragmatic domes was measured. Results: For the central thoracic locations, the largest motion was in the superoinferior (SI) dimension (>5 mm for bilateral hila and carina, but <4 mm for aortic arch). No significant difference was found in the motion of these locations in the absence or presence of enlarged nodes. For parenchymal tumors, upper tumors exhibited smaller SI motion than did lower tumors (3.7 vs. 10.4 mm, p = 0.029). Similarly, anterior tumors exhibited smaller motion than did posterior tumors in both the SI (4.0 vs. 8.0 mm, p = 0.013) and lateral (2.8 vs. 4.6 mm, p = 0.045) directions. The margins that would be needed to encompass the respiratory motion of each of the evaluated locations in 95% of patients were tabulated and range from 3.4 to 37.2 mm, depending on the location and direction. Conclusions: The results of our study have provided data for appropriate site-specific internal target volume expansion that could be useful in the absence of four-dimensional computed tomography-based treatment planning. However, generalizing the results from a small patient population requires discretion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

ORNL Quasi-Static Mechanical Characterization and Analysis: FY09 Annual Report to TARDEC

The testing and evaluation of candidate glasses for transparent armor served as a primary goal. Other armor ceramics were evaluated too, in support of the development of innovative test methods, whose use will ultimately help in the improvement of armor ceramics or help in better predicting their ballistic performance. The following summarizes this report and this year's work: (1) The elastic properties of a spherical indenter affect the forces necessary to initiate fracture in a target ceramics. The lower the elastic modulus of an indenter material, the easier (i.e., lower forces required) it is to initiate fracture. This implies the fracture initiation of an armor ceramic will depend on the elastic properties of a projectile material, and that this effect, represented by the Dundurs Parameter, can be managed to guide improvement of both armor and projectile materials. (2) The largest flaws in a population dictate both contact damage and fracture initiations. This implies the ballistic response of armor ceramics will improve if those large flaws are precluded from appearing in the materials during their processing. (3) Failure stress dependence on effective area for Hertzian indentation was developed. Such analysis is adaptable to predict ballistically produced fracture initiation as a function of projectile material and projectile size. (4) A simple, quick, and inexpensive test method was developed to measure the apparent yield stress of armor ceramics. This is significant because yield stress is used as input in ballistic models, and yield stress is traditionally measured using (complex, timeconsuming, and expensive) shock physics experiments. (5) Radial confinement increases the necessary indentation forces to initiate fracture and yield-like responses in ceramics. Ballistic improvement of an armor ceramic will occur if the ceramic can be compressively pre-stressed. (6) The median crack produced by a Hertzian indent is associated with a dramatic increase in target ceramic compliance. More so than any other produced damage mechanism. This suggests that a ballistically induced median crack in an armor ceramic may be associated with the dwell penetration event. (7) Glass exhibits tensile strength that is very much dependent on the amount of material, the side being tested (air versus tin if a float glass), and where it is being tensile stressed (in the middle or near an edge). The management of these effects will improve ballistic resistance of transparent armor (or any ceramic armor that is undergoing deflection as a consequence of a ballistic impact). (8) Plasma-arc heat treatment is a quick and relatively inexpensive method to improve the strength of glass. It is implementable into the production line for the mass production of glass. Increased strain-to-failure and bending deflections are concomitant with increased strength, and therefore, ballistic resistance is improvable using this method. (9) The Hertzian stress field at high contact stresses is very similar to the stress field from a ballistic impact. This is significant because the results from Hertzian indentation measurements have the prospect of being used as input in ballistic models to predict dwell conditions. (10) The understanding of glass densification and fragmentation behaviors are aided by piezo-Raman spectroscopy and quasi-static, high-energy fracture. Continued refinement of these test methods will improve the understanding of glass impact resistance. (11) In addition to glass, strength-size scaling was evident in SiC and B{sub 4}C. Previously proposed strength dependencies on rate from shock experiments may instead be explained by this strength-size scaling effect. (12) The quantification of strength-size scaling in armor ceramics clearly shows there is no single strength value that can be used to describe that ceramic. A ballistic modeler can therefore use more appropriate failure stress value(s) as input to predict deflection and expanding cavity responses in the ceramic target. These follow-on efforts are recommended based on the above statements: (1) Dynamic Hertzian indentation using a dynamic hardness tester; (2) Quantify flaw population size in strategic armor ceramics; (3) Refine and increase robustness of apparent yield stress measurement; (4) Quantify fracture and yield processed in armor ceramics as a function of confined stress; (5) Develop test method to accurately measure stress condition of median crack formation; (6) Measure strength-size scaling in glass ceramic candidates for transparent armor; (7) Refine plasma-arc heat treating to maximize strengthening of glasses and glass ceramics; (8) Refine ballistic modeling analysis to improve adaptability of Hertzian indentation results; (9) Refine densification and fragmentation test methods and interpretations; and (10) Predict ballistically-induced armor deflection and expanding cavity performance using strength-size scaling results.

36 MATERIALS SCIENCE↗

Quantification of the effect of uncertainty on impurity migration in PISCES-A simulated with GITR

A Bayesian inference strategy has been used to estimate uncertain inputs to global impurity transport code (GITR) modeling predictions of tungsten erosion and migration in the linear plasma device, PISCES-A. This allows quantification of GITR output uncertainty based on the uncertainties in measured PISCES-A plasma electron density and temperature profiles (n e , T e ) used as inputs to GITR. The technique has been applied for comparison to dedicated experiments performed for high (4 × 10 22 m –2 s –1 ) and low (5 × 10 21 m –2 s –1 ) flux 250 eV He–plasma exposed tungsten (W) targets designed to assess the net and gross erosion of tungsten, and corresponding W impurity transport. The W target design and orientation, impurity collector, and diagnostics, have been designed to eliminate complexities associated with tokamak divertor plasma exposures (inclined target, mixed plasma species, re-erosion, etc) to benchmark results against the trace impurity transport model simulated by GITR. The simulated results of the erosion, migration, and re-deposition of W during the experiment from the GITR code coupled to materials response models are presented. Specifically, the modeled and experimental W I emission spectroscopy data for a 429.4 nm line and net erosion through the target and collector mass difference measurements are compared. Furthermore, the methodology provides predictions of observable quantities of interest with quantified uncertainty, allowing estimation of moments, together with the sensitivities to plasma temperature and density.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Quantitatively controlled electrophoretic deposition of nanocrystal films from non-aqueous suspensions

This study presents a novel method to correlate the mass and charge transfer kinetics during the electrophoretic deposition of nanocrystal films by using a purpose-built double quartz crystal microbalance combined with simultaneous current-measurement. Our data support a multistep process for film formation: generation of charged nanocrystal flux, charge transfer at the electrode, and polarization of neutral nanocrystals near the electrode surface. The polarized particles are then subject to dielectrophoretic forces that reduce diffusion away from the interface, generating a sufficiently high neutral particle concentration at the interface to form a film. The correlation of mass and charge transfer enables quantification of the nanocrystal charge, the fraction of charged nanocrystals, and the initial sticking coefficient of the particles. These quantities permit calculation of the film thickness, providing a theoretical basis for using concentration and voltage as process parameters to grow films of targeted thicknesses.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Vertical column dual-comb spectroscopy to a TBS

Open-path dual-frequency-comb spectroscopy (DCS) is a broadband, high spectral resolution, and high precision method for measuring gas concentrations over kilometer-scale paths. It has been used for detection and quantification of emissions of pollutants, hazardous gasses, and greenhouse gasses (GHGs). DCS has been shown to measure trace-gas mixing ratios with 0.14%-0.4% agreement between instruments. To achieve high signal-to-noise ratios (SNRs) with DCS, comb light is targeted onto a retroreflector at the end of the measurement path, which returns the signal to a detector co-located with the launch signal. Installing the retroreflector on a mobile platform such as a balloon or unmanned aerial vehicle (UAV) extends the capabilities of DCS by enabling variable path lengths, greater mobility, and access to higher altitudes. Mobile-target DCS has many uses in plume and leak detection, emissions modeling, and planetary boundary layer (PBL) studies. It is a promising method for observing vertical distributions of GHGs and mixing processes in the PBL, which are difficult to measure but important for pollution and climate monitoring as well as for understanding transport of gasses through the atmosphere. Tethered balloons are an intriguing platform because they enable longer flight durations and higher altitudes than easily obtainable with a UAV and thus allow for column measurements up to and above the PBL. New measurements completed in October/November 2024 reach the highest altitudes above ground level yet achieved by mobile-target DCS. For these measurements, the retroreflector was mounted on a 7 m diameter tethered helium balloon. An actively tracking gimbal on the ground holds the DCS launch telescope and keeps the 5 cm beam pointed onto the retroreflector while the balloon is lifted, lowered, and moved by wind and turbulence.

atmosphere↗

Advancing Inverse Sensitivity/Uncertainty Methods for Nuclear Fuel Cycle Applications

The inverse sensitivity/uncertainty quantification (IS/UQ) method has recently been implemented in the Inverse Sensitivity/UnceRtainty Estimiator (INSURE) module of the AMPX system [1]. The IS/UQ method aims to quantify and prioritize the cross section measurements along with uncertainties needed to yield a given nuclear application(s) target response uncertainty, and doing this at a minimum cost. Since in some cases the extant uncertainties of the differential cross section data are already near the limits of the present-day state-of-the-art measurements, requiring significantly smaller uncertainties may be unrealistic. Therefore we have incorporated integral benchmark experiments (IBEs) data into the IS/UQ method using the generalized linear least-squares method, and have implemented it in the INSURE module. We show how the IS/UQ method could be applied to systematic and statistical uncertainties in a self-consistent way. We show how the IS/UQ method could be used to optimize uncertainties of IBEs and differential cross section data simultaneously.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Multiscale modeling of HBV infection integrating intra- and intercellular viral propagation to analyze extracellular viral markers

Chronic infection with hepatitis B virus (HBV) is caused by the persistence of closed circular DNA (cccDNA) in the nucleus of infected hepatocytes. Despite available therapeutic anti-HBV agents, eliminating the cccDNA remains challenging. Thus, quantifying and understanding the dynamics of cccDNA are essential for developing effective treatment strategies and new drugs. However, such study requires repeated liver biopsy to measure the intrahepatic cccDNA, which is basically not accepted because liver biopsy is potentially morbid and not common during hepatitis B treatment. We here aimed to develop a noninvasive method for quantifying cccDNA in the liver using surrogate markers in peripheral blood. We constructed a multiscale mathematical model that explicitly incorporates both intracellular and intercellular HBV infection processes. The model, based on age-structured partial differential equations, integrates experimental data from in vitro and in vivo investigations. By applying this model, we roughly predicted the amount and dynamics of intrahepatic cccDNA within a certain range using specific viral markers in serum samples, including HBV DNA, HBsAg, HBeAg, and HBcrAg. Our study represents a significant step towards advancing the understanding of chronic HBV infection. The noninvasive quantification of cccDNA using our proposed method holds promise for improving clinical analyses and treatment strategies. By comprehensively describing the interactions of all components involved in HBV infection, our multiscale mathematical model provides a valuable framework for further research and the development of targeted interventions.

59 BASIC BIOLOGICAL SCIENCES↗

Integration of a hyphenated HPIC-ICPMS protocol for the measurement of transplutonium isotopic mass distributions for 252Cf campaigns at Oak Ridge National Laboratory

Rapid measurement of transplutonium isotopic mass distributions during 252Cf production campaigns at Oak Ridge National Laboratory is a critical need. Mass measurements for the isotopes of plutonium, americium, curium, and californium are routinely requested to support the α-hydroxy-isobutyrate runs for the purification and recovery of the heavy curium target material and final 249Bk, 252Cf, and 254Es enriched isotope products. This paper presents the integration of an online high-pressure ion chromatography inductively coupled plasma mass spectrometry technique together with the protocol and chemistry that allows for rapid baseline separation and direct quantification of the transplutonium elemental concentrations and isotopic compositions.

Roach, Benjamin↗

Elastic scattering of 3 He + 4 He with the SONIK scattering chamber

Measurements of the elastic scattering cross section of 3 He and 4 He are important in order to improve constraints on theoretical models of 4 He ⁢( 3 He ,𝛾)⁢ 7 Be, a key reaction in Big Bang nucleosynthesis and solar neutrino production. The astrophysical 𝑆 factor for this reaction is a significant source of uncertainty in the standard-solar-model prediction of the 7 Be and 8 B solar neutrino fluxes. The elastic scattering measurements reported in the literature do not extend to low energies and lack proper uncertainty quantification. A new measurement of the 4 He ⁢( 3 He, 3 He)⁢ 4 He reaction has been made at center-of-mass energies 𝐸c.m.=0.38−3.13 MeV using the Scattering of Nuclei in Inverse Kinematics (SONIK) scattering chamber: a windowless, extended gas target surrounded by an array of 30 collimated silicon charged particle detectors situated at TRIUMF. This is the first elastic scattering measurement of 3 He + 4 He made below 500 keV and it has greater angular range and better precision than previous measurements. The elastic scattering data were analyzed using both 𝑅-matrix and halo effective field theory frameworks, and values of the 𝑠-wave scattering length and effective range were extracted. Here, the resulting improvement in knowledge of the 𝑠-wave effective-range function at low energies reduces the overall uncertainty in 𝑆 34 at solar energies.

Elastic scattering reactions↗

SU-G-IeP3-07: High-Resolution, High-Sensitivity Imaging and Quantification of Intratumoral Distributions of Gold Nanoparticles Using a Benchtop L-Shell XRF Imaging System

Purpose: To demonstrate the ability to perform high-resolution imaging and quantification of sparse distributions of gold nanoparticles (GNPs) within ex vivo tumor samples using a highly-sensitive benchtop L-shell x-ray fluorescence (XRF) imaging system. Methods: An optimized L-shell XRF imaging system was assembled using a tungsten-target x-ray source (operated at 62 kVp and 45 mA). The x-rays were filtered (copper: 0.08 mm & aluminum: 0.04 mm) and collimated (lead: 5 cm thickness, 3 cm aperture diameter) into a cone-beam in order to irradiate small samples or objects. A collimated (stainless steel: 4 cm thickness, 2 mm aperture diameter) silicon drift detector, capable of 2D translation, was placed at 90° with respect to the beam to acquire XRF/scatter spectra from regions of interest. Spectral processing involved extracting XRF signal from background, followed by attenuation correction using a Compton scatter-based normalization algorithm. Calibration phantoms with water/GNPs (0 and 0.00001–10 mg/cm{sup 3}) were used to determine the detection limit of the system at a 10-second acquisition time. The system was then used to map the distribution of GNPs within a 12×11×2 mm{sup 3} slice excised from the center of a GNP-loaded ex vivo murine tumor sample; a total of 110 voxels (2.65×10{sup −3} cm{sup 3}) were imaged with 1.3-mm spatial resolution. Results: The detection limit of the current cone-beam benchtop L-shell XRF system was 0.003 mg/cm{sup 3} (3 ppm). Intratumoral GNP concentrations ranging from 0.003 mg/cm{sup 3} (3 ppm) to a maximum of 0.055 mg/cm{sup 3} (55 ppm) and average of 0.0093 mg/cm{sup 3} (9.3 ppm) were imaged successfully within the ex vivo tumor slice. Conclusion: The developed cone-beam benchtop L-shell XRF imaging system can immediately be used for imaging of ex vivo tumor samples containing low concentrations of GNPs. With minor finetuning/optimization, the system can be directly adapted for performing routine preclinical in vivo imaging tasks. Supported by NIH/NCI grant R01CA155446 This investigation was supported by NIH/NCI grant R01CA155446.

60 APPLIED LIFE SCIENCES↗

Hydrologic Model Analyses for Decision Support at the Los Alamos National Laboratory Site - 18363

Modeling hydrologic flow and transport in the subsurface presents a number of challenges including large datasets that contain limited information about the properties of the subsurface and models with a large number of parameters characterizing the properties of the subsurface and the ambient hydrologic conditions (e.g., groundwater recharge). This, in turn, leads to substantial uncertainty in predictions about quantities of interest (e.g., the concentration of a contaminant at points of compliance). We present a number of methods and tools that have recently been developed to address these problems. The model calibration tools are capable of assimilating large datasets (for example, on the order of 1,000,000 model calibration targets) into numerical models, calibrating models with a large number of model parameters (on the order of 1,000,000), or both. These tools leverage recently developed methods in numerical linear algebra such as matrix-free methods and randomized matrix sketching. The uncertainty quantification tools are highly-parallel and enable us to robustly quantify the uncertainties in model parameters (and therefore uncertainty in quantities of interest). Having these capabilities in model analysis tools enables more informed decision making related to remediation of groundwater contaminants. The model analyses that we present are related to the Los Alamos National Laboratory (LANL) chromium site. The analyses are performed by MADS (Model Analysis and Decision Support; http://mads.lanl.gov). (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Quantification of water content by laser induced breakdown spectroscopy on Mars

Laser induced breakdown spectroscopy (LIBS), as performed by the ChemCam instrument, provides a new technique to measure hydrogen at the surface of Mars. Using a laboratory replica of the LIBS instrument onboard the Curiosity rover, different types of hydrated samples (basalts, calcium and magnesium sulfates, opals and apatites) covering a range of targets observed on Mars have been characterized and analyzed in this paper. A number of factors related to laser parameters, atmospheric conditions and differences in targets properties can affect the standoff LIBS signal, and in particular the hydrogen emission peak. Dedicated laboratory tests were run to identify a normalization of the hydrogen signal which could best compensate for these effects and enable the application of the laboratory calibration to Mars data. We check that the hydrogen signal increases linearly with water content; and normalization of the hydrogen emission peak using to oxygen and carbon emission peaks (related to the breakdown of atmospheric carbon dioxide) constitutes a robust approach. Finally, moreover, the calibration curve obtained is relatively independent of the samples types.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Low-Cost alpha Alane for Hydrogen Storage

This project was directed towards the further development of the Savannah River National Laboratory (SRNL) lab-scale electrochemical synthesis of the hydrogen storage material alpha-alane and Ardica Technologies-SRI International (SRI) chemical downstream processes that are necessary to meet DoE cost metrics and transition alpha-alane synthesis to an industrial scale. Ardica has demonstrated the use of alpha-alane in a fuel-cell system for the U.S. Army WFC20 20W soldier power system that has successfully passed initial field trials with individual soldiers. While alpha-alane has been clearly identified as a desirable hydrogen storage material, cost-effective means for its production and regeneration on a scale of use applicable to the industry have yet to be established. We focused on three, principal development areas: 1. The construction of a comprehensive engineering techno-economic model to establish the production costs of alpha-alane by both electrochemical and chemical routes at scale. 2. The identification of critical, cost-saving design elements of the electrochemical cell and the quantification of the product yields of the primary electrochemical process. A moving particle-bed reactor design was constructed and operated. 3. The experimental quantification of the product yields of candidate downstream chemical processes necessary to produce alpha-alane to complete the most cost-effective overall manufacturing process. Our techno-economic model shows that under key assumptions most 2015 and 2020 DOE hydrogen storage system cost targets for low and medium power can be achieved using the electrochemical alane synthesis process. To meet the most aggressive 2020 storage system cost target, $1/g, our model indicates that 420 metric tons per year (MT/y) production of alpha-alane is required. Laboratory-scale experimental work demonstrated that the yields of two of the three critical component steps within the overall “electrochemical process” were sufficiently high to meet this production target. In the case of the yield of the third step, the crystallization of alpha-alane from the primary alane-related product of the electrochemical reaction, further development is required.

08 HYDROGEN↗

Estimating the cost of saving electricity through U.S. utility customer-funded energy efficiency programs

The program administrator and total cost of saved energy allow comparison of the cost of efficiency across utilities, states, and program types, and can identify potential performance improvements. Comparing program administrator cost with the total cost of saved energy can indicate the degree to which programs leverage investment by participants. Based on reported total costs and savings information for U.S. utility efficiency programs from 2009 to 2013, here we estimate the savings-weighted average total cost of saved electricity across 20 states at 0.046 per kilowatt-hour (kW h), comparing favorably with energy supply costs and retail rates. Programs targeted on the residential market averaged 0.030 per kW h compared to 0.053 per kW h for non-residential programs. Lighting programs, with an average total cost of 0.018 per kW h, drove lower savings costs in the residential market. We provide estimates for the most common program types and find that program administrators and participants on average are splitting the costs of efficiency in half. More consistent, standardized and complete reporting on efficiency programs is needed. Differing definitions and quantification of costs, savings and savings lifetimes pose challenges for comparing program results. Reducing these uncertainties could increase confidence in efficiency as a resource among planners and policymakers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Characterization and Improvement of RNA-Seq Precision in Quantitative Transcript Expression Profiling

Measurement precision determines the power of any analysis to reliably identify significant signals, such as in screens for differential expression, independent of whether the experimental design incorporates replicates or not. With the compilation of large scale RNA-Seq data sets with technical replicate samples, however, we can now, for the first time, perform a systematic analysis of the precision of expression level estimates from massively parallel sequencing technology. This then allows considerations for its improvement by computational or experimental means. Results: We report on a comprehensive study of target coverage and measurement precision, including their dependence on transcript expression levels, read depth and other parameters. In particular, an impressive target coverage of 84% of the estimated true transcript population could be achieved with 331 million 50 bp reads, with diminishing returns from longer read lengths and even less gains from increased sequencing depths. Most of the measurement power (75%) is spent on only 7% of the known transcriptome, however, making less strongly expressed transcripts harder to measure. Consequently, less than 30% of all transcripts could be quantified reliably with a relative error < 20%. Based on established tools, we then introduce a new approach for mapping and analyzing sequencing reads that yields substantially improved performance in gene expression profiling, increasing the number of transcripts that can reliably be quantified to over 40%. Extrapolations to higher sequencing depths highlight the need for efficient complementary steps. In discussion we outline possible experimental and computational strategies for further improvements in quantification precision.

59 BASIC BIOLOGICAL SCIENCES↗

Identifying high-impact and high-uncertainty parameters in MiniFuel model predictions

The MiniFuel irradiation platform at Oak Ridge National Laboratory's High Flux Isotope Reactor (HFIR) is a flexible, high-throughput separate effects test capability. Finite element thermal models are relied upon to design MiniFuel experiments and to achieve experimental objectives. Recent reports show good agreement in the model prediction of target fuel temperatures, but as the capability of the experiments is extended to higher temperatures, the uncertainty in the model predictions must be quantified. To that end, high-impact, high-uncertainty parameters that contribute the most uncertainty to the model are identified. The uncertainty quantification was accomplished through a series of screening and sensitivity analyses. The first analysis utilizes the method of Morris to perform a computationally efficient preliminary screening that considers uncertainty in a large number of the model inputs. The most important parameters identified in the Morris screening study were then considered in a Sobol sensitivity analysis that more robustly ranks and quantifies the uncertainty associated with each parameter. From these analyses, it was determined that thermal contact conductance between components is the parameter that contributes the highest uncertainty. The estimated uncertainty of the MiniFuel model fuel temperature predictions is ±80 °C in the removable beryllium and ±40 °C in the vertical experiment facilities. In conclusion, the framework established by the series of sensitivity analyses presented herein could easily be adapted to fit the needs of accelerated fuel qualification processes.

Fuel, Irradiation↗

Ensemble methods for quantification of potassium oxide in ChemCam Mars and laboratory spectra

In this paper we test new approaches for predicting the amount of element oxides in rock samples from the ChemCam instrument suite onboard the NASA Curiosity rover by focusing on K 2 O. Using the expanded dataset compiled by Gasda et al. (2021) with and without the Earth to Mars (E2M and NoE2M) transformation discussed in Clegg et al. (2017) we trained blended submodels using the “double blending” technique and compared these to ensemble methods (Random Forest, ExtraTrees, and Gradient Boosting Regression). We found that ensemble methods performed similar to blended submodels when looking at RMSE-P on the laboratory spectra and provided significant advantages when looking at spectra coming from Mars. For the full model, blended submodels achieved an RMSE-P of 0.62 and 0.60 (E2M and NoE2M respectively) while Gradient Boosting Regression resulted in a slightly improved RMSE-P of 0.59 and 0.60. More importantly, by employing a local RMSE-P estimation technique where model performance is evaluated based on nearby test samples we found that using ensemble methods can lower the quantification limit for K 2 O from the current value of ≈0.6 wt% to ≈0.08 wt% using Extra Trees and Random Forest. This would allow for a much larger range of K 2 O values to be quantified on Mars with greater certainty given that most targets seen on Mars tend to have <1 wt% K2O. Finally, we used both Mean Decrease in Impurity (MDI) and permutation importance techniques to investigate the wavelengths used by the ensemble methods and found that they correspond to known potassium emission lines. This suggests that ensemble methods can provide an easier to train and improved alternative to blended submodels for predicting potassium compositions from Laser Induced Breakdown Spectroscopy (LIBS) data.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗