Search NASA⌕ Search

SEARCH · Search NASA

Results for “teeth”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Dynamically stable, self-similarly evolving, and self-organized states of high beta tokamak and reversed pinch plasmas and advanced active control

Generalized simultaneous eigenvalue equations derived from a generalized theory of self-organization are applied to a set of simultaneous equations for two-fluid model plasmas. An advanced active control by using theoretical time constants is proposed by predicting quantities to be controlled. Typical high beta numerical configurations are presented for the ultra low q tokamak plasmas and the reversed-field pinch (RFP) ones in cylindrical geometry by solving the set of simultaneous eigenvalue equations. Improved confinement with no detectable saw-teeth oscillations in tokamak experiments is reasonably explained by the shortest time constant of ion flow. The shortest time constant of poloidal ion flow is shown to be a reasonable mechanism for suppression of magnetic fluctuations by pulsed poloidal current drives in RFP experiments. The bifurcation from basic eigenmodes to mixed ones deduced from stability conditions for eigenvalues is shown to be a good candidate for the experimental bifurcation from standard RFP plasmas to their improved confinement regimes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Material Behavior At The Extreme Cutting Edge In Bandsawing

In recent years, bandsawing has been widely accepted as a favourite option for metal cutting off operations where the accuracy of cut, good surface finish, low kerf loss, long tool life and high material removal rate are required. Material removal by multipoint cutting tools such as bandsaw is a complex mechanism owing to the geometry of the bandsaw tooth (e.g., limited gullet size, tooth setting etc.) and the layer of material removed or undeformed chip thickness or depth of cut (5 {mu}m-50 {mu}m) being smaller than or equal to the cutting edge radius (5 {mu}m-15 {mu}m). This situation can lead to inefficient material removal in bandsawing. Most of the research work are concentrated on the mechanics of material removal by single point cutting tool such as lathe tool. However, such efforts are very limited in multipoint cutting tools such as in bandsaw. This paper presents the fundamental understanding of the material behaviour at the extreme cutting edge of bandsaw tooth, which would help in designing and manufacturing of blades with higher cutting performance and life. ''High Speed Photography'' has been carried out to analyse the material removal process at the extreme cutting edge of bandsaw tooth. Geometric model of chip formation mechanisms based on the evidences found during ''High Speed Photography'' and ''Quick Stop'' process is presented. Wear modes and mechanism in bimetal and carbide tipped bandsaw teeth are also presented.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Modelling Of Residual Stresses Induced By High Speed Milling Process

Maintenance processes used in heavy industries often include high speed milling operations. The reliability of the post-process material state has to be studied. Numerical simulation appears to be a very interesting way to supply an efficient residual stresses (RS) distribution prediction.Because the adiabatic shear band and the serrated chip shaping are features of the austenitic stainless steel high speed machining, a 2D high speed orthogonal cutting model is briefly presented. This finite element model, developed on Forge registered software, is based on data taken from Outeiro and al.'s paper [1]. A new behaviour law fully coupling Johnson-Cook's constitutive law and Latham and Cockcroft's damage model is detailed in this paper. It ensures results that fit those found in literature.Then, the numerical tools used on the 2D model are integrated to a 3D high speed milling model. Residual stresses distribution is analysed, on the surface and into the depth of the material. Various revolutions and passes of the two teeth hemispheric mill on the workpiece are simulated. Thus the sensitivity of the residual stresses generation to the cutting conditions can be discussed. In order to validate the 3D model, a comparison of the cutting forces measured by EDF R and D to those given by numerical simulations is achieved.

36 MATERIALS SCIENCE↗

Sintering Effects on Morphology, Thermal Stability and Surface Area of Sol-Gel Derived Nano-Hydroxyapatite Powder

Hydroxyapatite (HAP) ceramics have been recognized as substitute materials for bone and teeth in orthopedic and dentistry field due to their chemical and biological similarity to human hard tissue. The nanosized and nanocrystalline forms of HAP have great potential to revolutionize the hard tissue-engineering field, starting from bone repair and augmentation to controlled drug delivery systems. This paper reports the synthesis of biomimetic nano-hydroxyapatite (HAP) by sol-gel method using calcium nitrate tetrahydrate (CNT) and potassium dihydrogen phosphate (KDP) as calcium and phosphorus precursors, respectively to obtain a desired Ca/P ratio of 1.67. Deionized water was used as a diluting media for HAP sol preparation and ammonia was used to adjust the pH to 11. After aging, the HAP gel was dried at 55 deg. C and sintered to different temperatures (200 deg. C, 400 deg. C, 600 deg. C, 800 deg. C, 1000 deg. C and 1200 deg. C). The dried and sintered powders were characterized for phase composition using Fourier transform infrared (FTIR) spectroscopy and X-ray diffraction (XRD). The particle size and morphology was studied using transmission electron microscopy (TEM). The thermal behavior of the dried HAP nanopowder was studied in the temperature range of 55 deg. C to 1000 deg. C using thermal gravimetric analyser (TGA). The BET surface area of absorbance was determined by Nitrogen adsorption using Brunauer-Emmett-Teller (BET) method. The presence of characteristic peaks of the phosphate and OH groups in FTIR spectrums confirmed the formation of pure HAP in dried as well as sintered powders. XRD results also confirmed the formation of stoichiometric nano-HAP. Sintering revealed that with increase in temperature, both the crystallinity and crystallite size of nano-HAP particles increased. The synthesized nano-HAP powder was found to be stable upto 1000 deg. C without any additional phase other than HAP, whereas peak of {beta}-TCP (tricalcium phosphate) was observed at 1200 deg. C. Photomicrograph of TEM showed that the nanopowder sintered at 600 deg. C is composed of hydroxyapatite nanoparticles (26.0-45.6 nm), which is well in agreement with the crystallite size calculated using XRD data. TGA study showed the thermal stability of the synthesized nano-HAP powder. The BET surface area decreased with increase in sintering temperature.

36 MATERIALS SCIENCE↗

Stray RF Power Estimates From EC Exploitation During ITER Plasma Operations

The EC H and CD system of ITER tokamak is an essential tool for all the phases of ITER operation. Different levels of EC power are required through all the plasma discharge: up to 6.7 MW for assisting the breakdown and burn through, up to 20 MW for current drive and saw-teeth control from the equatorial launcher and up to 20 MW for NTM stabilization from the upper launchers. The assistance to breakdown and burn through is characterized by a very low (if not negligible) RF power absorption by the plasma. A significant level of stray radiation may also arise from partial absorption due to non-optimal plasma parameters and/or wrong injected polarization. The stray power radiated in the vacuum chamber is estimated as a first step toward mitigating potential harmful consequence to in-vessel structures and diagnostics. Power loading of the chamber walls (peek power and average power density for straight beam propagation in the empty chamber) and diffuse stray radiation effects are simulated to infer suitable strategies to avoid damage to first wall and to microwave sensitive components.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Non-destructive thermal wave method applied to study thermal properties of fast setting time endodontic cement

The thermal wave method is applied for thermal properties measurement in fast endodontic cement (CER). This new formula is developed upon using Portland cement in gel and it was successfully tested in mice with good biocompatibility and stimulated mineralization. Recently, thermal expansion and setting time were measured, conferring to this material twice faster hardening than the well known Angelus Mineral trioxide aggregate (MTA) the feature of fast hardening (∼7 min) and with similar thermal expansion (∼12 μstrain/ °C). Therefore, it is important the knowledge of thermal properties like thermal diffusivity, conductivity, effusivity in order to match thermally the tissue environment upon its application in filling cavities of teeth. Photothermal radiometry technique based on Xe illumination was applied in CER disks 600 μm thick for heating, with prepared in four particle sizes (25, 38, 45, and 53) μm, which were added microemulsion gel with variation volumes (140, 150, 160, and 170) μl. The behavior of the thermal diffusivity CER disks shows linear decay for increase emulsion volume, and in contrast, thermal diffusivity increases with particles sizes. Aiming to compare to MTA, thermal properties of CER were averaged to get the figure of merit for thermal diffusivity as (44.2 ± 3.6) × 10{sup −3} cm{sup 2}/s, for thermal conductivity (228 ± 32) mW/cm K, the thermal effusivity (1.09 ± 0.06) W s{sup 0.5}/cm{sup 2} K and volume heat capacity (5.2 ± 0.7) J/cm{sup 3} K, which are in excellent agreement with results of a disk prepared from commercial MTA-Angelus (grain size < 10 μm using 57 μl of distilled water)

36 MATERIALS SCIENCE↗

Analysis of surface integrity of grinded gears using Barkhausen noise analysis and x-ray diffraction

The contribution is focused to present results of study grinded gears made of 18CrNiMo7-6 steel used in the wind power plant for support (service) purposes. These gears were case-hardened due to standard hard case and soft core formation. This heat treatment increases wear resistance and fatigue strength of machine parts. During serial production some troubles with surface integrity have occurred. When solving complex problems lots of samples were prepared. For grinding of gears were used different parameters of cutting speed, number of material removal and lots from different subsuppliers. Material characterization was carried out using Barkhausen noise analysis (BNA) device; X-ray diffraction (XRD) measurement of surface residual stresses was done as well. Depth profile of measured characteristics, e.g. magnetoelastic parameter and residual stress was obtained by step by step layers' removing using electrolytic etching. BNA software Viewscan was used to measure magnetizing frequency sweep (MFS) and magnetizing voltage sweep (MVS). Scanning of Magnetoelastic parameter (MP) endwise individual teeth were also carried out with Viewscan. These measurements were done to find problematic surface areas after grinding such as thermal damaged locations. Plots of the hardness and thickness of case-hardened layer on cross sections were measurered as well. Evaluation of structure of subsurface case-hardened layer and core was made on etched metallographic patterns. The aim of performed measurements was to find correlation between conditions of grinding, residual stresses and structural and magnetoelastic parameters. Based on correlation of measured values and technological parameters optimizing the production of gears will be done.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Non-axisymmetric equilibrium reconstruction of a current-carrying stellarator using external magnetic and soft x-ray inversion radius measurements

Non-axisymmetric free-boundary equilibrium reconstructions of stellarator plasmas are performed for discharges in which the magnetic configuration is strongly modified by ohmically driven plasma current. These studies were performed on the compact toroidal hybrid device using the V3FIT reconstruction code with a set of 50 magnetic diagnostics external to the plasma. With the assumption of closed magnetic flux surfaces, the reconstructions using external magnetic measurements allow accurate estimates of the net toroidal flux within the last closed flux surface, the edge safety factor, and the plasma shape of these highly non-axisymmetric plasmas. Lastly, the inversion radius of standard saw-teeth is used to infer the current profile near the magnetic axis; with external magnetic diagnostics alone, the current density profile is imprecisely reconstructed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Detection of questionable occlusal carious lesions using an electrical bioimpedance method with fractional electrical model

This in vitro study evaluated the diagnostic performance of an alternative electric bioimpedance spectroscopy technique (BIS-STEP) detect questionable occlusal carious lesions. Six specialists carried out the visual (V), radiography (R), and combined (VR) exams of 57 sound or non-cavitated occlusal carious lesion teeth classifying the occlusal surfaces in sound surface (H), enamel caries (EC), and dentinal caries (DC). Measurements were based on the current response to a step voltage excitation (BIS-STEP). A fractional electrical model was used to predict the current response in the time domain and to estimate the model parameters: Rs and Rp (resistive parameters), and C and α (fractional parameters). Histological analysis showed caries prevalence of 33.3% being 15.8% hidden caries. Combined examination obtained the best traditional diagnostic results with specificity = 59.0%, sensitivity = 70.9%, and accuracy = 60.8%. There were statistically significant differences in bioimpedance parameters between the H and EC groups (p = 0.016) and between the H and DC groups (Rs, p = 0.006; Rp, p = 0.022, and α, p = 0.041). Using a suitable threshold for the Rs, we obtained specificity = 60.7%, sensitivity = 77.9%, accuracy = 73.2%, and 100% of detection for deep lesions. It can be concluded that BIS-STEP method could be an important tool to improve the detection and management of occlusal non-cavitated primary caries and pigmented sites.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Bacterial biofilm shows persistent resistance to liquid wetting and gas penetration

Most of the world's bacteria exist in robust, sessile communities known as biofilms, ubiquitously adherent to environmental surfaces from ocean floors to human teeth and notoriously resistant to antimicrobial agents. We report the surprising observation that Bacillus subtilis biofilm colonies and pellicles are extremely nonwetting, greatly surpassing the repellency of Teflon toward water and lower surface tension liquids. The biofilm surface remains nonwetting against up to 80% ethanol as well as other organic solvents and commercial biocides across a large and clinically important concentration range. We show that this property limits the penetration of antimicrobial liquids into the biofilm, severely compromising their efficacy. To highlight the mechanisms of this phenomenon, we performed experiments with mutant biofilms lacking ECM components and with functionalized polymeric replicas of biofilm microstructure. We show that the nonwetting properties are a synergistic result of ECM composition, multiscale roughness, reentrant topography, and possibly yet other factors related to the dynamic nature of the biofilm surface. Finally, we report the impenetrability of the biofilm surface by gases, implying defense capability against vapor-phase antimicrobials as well. These remarkable properties of B. subtilis biofilm, which may have evolved as a protection mechanism against native environmental threats, provide a new direction in both antimicrobial research and bioinspired liquid-repellent surface paradigms.

59 BASIC BIOLOGICAL SCIENCES↗

KEPLER-16b: SAFE IN A RESONANCE CELL

The planet Kepler-16b is known to follow a circumbinary orbit around a system of two main-sequence stars. We construct stability diagrams in the ''pericentric distance-eccentricity'' plane, which show that Kepler-16b is in a hazardous vicinity to the chaos domain-just between the instability ''teeth'' in the space of orbital parameters. Kepler-16b survives, because it is close to the stable half-integer 11/2 orbital resonance with the central binary, safe inside a resonance cell bounded by the unstable 5/1 and 6/1 resonances. The neighboring resonance cells are vacant, because they are ''purged'' by Kepler-16b, due to overlap of first-order resonances with the planet. The newly discovered planets Kepler-34b and Kepler-35b are also safe inside resonance cells at the chaos border.

79 ASTRONOMY AND ASTROPHYSICS↗

The Kinematics of Proal Chewing in Rats

Chewing kinematics are well-documented in several mammal species with fused mandibular symphyses, but relatively understudied in mammals with an unfused symphysis, despite the fact that more than half of extant Mammalia have an unfused mandibular symphysis. The Wistar brown rat (Rattus norvegicus) is widely used in human health research, including studies of mastication or neurological studies where mastication is the output behavior. These animals are known to have unfused mandibular symphyses and proal jaw (rostrocaudal) motion during occlusion, but the lack of high resolution, 3-dimensional analysis of rat chewing leaves the functional significance of symphyseal mobility unknown. We used biplanar fluoroscopy and the X-ray reconstruction of moving morphology workflow to quantify chewing kinematics in 3 brown rats, quantifying overall jaw kinematics, including motions about the temporomandibular joint and unfused mandibular symphysis. During occlusion, the teeth and the mandibular condyle translate almost exclusively anteriorly (proal) during occlusion, with little motion in any other degrees of freedom. At the symphysis, we observed minimal flexion throughout the chew cycle. Overall, there are fundamental differences in jaw kinematics between rats and other mammals and therefore rats are not an appropriate proxy for ancestral mammal jaw mechanics. Additionally, differences between humans and rat chewing kinematics must be considered when using rats as a clinical model for pathological feeding research.

59 BASIC BIOLOGICAL SCIENCES↗

EURADOS INTERCOMPARISON ON MEASUREMENTS AND MONTE CARLO MODELLING FOR THE ASSESSMENT OF AMERICIUM IN A USTUR LEG PHANTOM

United States Transuranium and Uranium Registries (USTUR) Case 0102 was the first whole-body donation to the USTUR (1979), of a worker affected by a substantial accidental 241Am intake(1). Half of this man’s skeleton, encased in tissue-quivalent plastic, provides a unique human ‘phantom’ for calibrating in vivo counting systems. In this case, the 241Am skeletal activity was measured 25 y after the intake. Approximately 82 % of the 241Am remaining in the body was found in the bones and teeth. The241Am activity concentration throughout the skeleton (in all types of bone) was fairly uniform(2). A protocol has been proposed by a group of in vivo laboratories from Europe [CIEMAT-Spain, IRSN-France and Helmholtz Zentrum Mu¨nchen (HMGU)-Germany] and Canada (HML) participating in this DOS/USTUR intercomparison. The focus areas for the study included: (1) the efficiency pattern along the leg phantom using Germanium detectors (experimental and computational), (2) the comparison of Monte Carlo (MC) results with experimental values in counting efficiency data and (3) the inflence of americium distribution in the bone material (volume or surface).

61 RADIATION PROTECTION AND DOSIMETRY↗

Multiplexed communication over a high-speed quantum channel

In quantum information systems it is of particular interest to consider the best way in which to use the nonclassical resources consumed by that system. Quantum communication protocols are integral to quantum information systems and are among the most promising near-term applications of quantum information science. Here we show that a multiplexed, digital quantum communications system supported by a comb of vacuum squeezing has a greater channel capacity per photon than a source of broadband squeezing with the same analog band width. We report on the time-resolved, simultaneous observation of the first dozen teeth in a 2.4-GHz comb of vacuum squeezing produced by a subthreshold optical parametric oscillator, as required for such a quantum communications channel. We also demonstrate multiplexed communication on that channel.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Ultrashort-pulse-train pump and dump excitation of a diatomic molecule

An excitation scheme is proposed for transferring population between ground-vibrational levels of a molecule. The transfer is accomplished by pumping and dumping population with a pair of coherent ultrashort-pulse trains via a stationary state. By mismatching the teeth of the frequency combs associated with the pulse trains to the vibrational levels, high selectivity in the excitation, along with high transfer efficiency, is predicted. The pump-dump scheme does not suffer from spontaneous emission losses, it is insensitive to the pump-dump-train delay, and it requires only basic pulse shaping.

74 ATOMIC AND MOLECULAR PHYSICS↗

Doppler cooling with coherent trains of laser pulses and a tunable velocity comb

We explore the possibility of decelerating and Doppler cooling an ensemble of two-level atoms by a coherent train of short, nonoverlapping laser pulses. We derive analytical expressions for mechanical force exerted by the train. In frequency space the force pattern reflects the underlying frequency comb structure. The pattern depends strongly on the ratio of the atomic lifetime to the repetition time between the pulses and pulse area. For example, in the limit of short lifetimes, the frequency-space peaks of the optical force wash out. We propose to tune the carrier-envelope offset frequency to follow the Doppler-shifted detuning as atoms decelerate; this leads to compression of atomic velocity distribution about comb teeth and results in a ''velocity comb''--a series of narrow equidistant peaks in the velocity space.

74 ATOMIC AND MOLECULAR PHYSICS↗

Mechanical and Thermal Performance of Transverse Flux Machines

This research examines the vibration and thermal characteristics of double-sided flux concentrating Transverse Flux Machines (TFM), designed for direct drive application. Two TFM prototypes with different stator cores, one with Quasi U-Core and the other with E-Core, has been used for the study. 3D Finite Element Analysis (FEA) has been carried out to determine the no-load and with load performance of the TFMs along with their fluctuating axial electromagnetic force densities acting on the stator teeth. The deformation response of the stator cores was observed in the static structural analysis. Thermal analysis for the TFM was performed through FEA based on copper and iron losses in the machine to examine the temperature rise in different parts of the machine structure. Acceleration and noise measurements were experimentally obtained to characterize the vibrational performance of the prototypes.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Mechanical Performance of Transverse Flux Machines

This research examines the structural and vibrational characteristics of double-sided flux-concentrating transverse flux machines (TFMs), designed for direct-drive application. Two prototypes of TFM with different stator cores, one with Quasi U-Core and the other with E-Core, have been used for this study. Three-dimensional finite element analysis has been carried out to determine the no-load and with-load performances of the TFMs along with their fluctuating axial electromagnetic force densities acting on the stator teeth. The deformation response of the stator cores was observed in the static structural analysis. Acceleration and noise measurements were experimentally obtained to characterize the vibrational performance of the prototypes.

24 POWER TRANSMISSION AND DISTRIBUTION↗