Search NASA⌕ Search

SEARCH · Search NASA

Results for “tensor sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

TU-EF-BRA-02: Longitudinal Proton Spin Relaxation and T1-Imaging

NMR, and Proton Density MRI of the 1D Patient - Anthony Wolbarst Net Voxel Magnetization, m(x,t). T1-MRI; The MRI Device - Lisa Lemen ‘Classical’ NMR; FID Imaging in 1D via k-Space - Nathan Yanasak Spin-Echo; S-E/Spin Warp in a 2D Slice - Ronald Price Magnetic resonance imaging not only reveals the structural, anatomic details of the body, as does CT, but also it can provide information on the physiological status and pathologies of its tissues, like nuclear medicine. It can display high-quality slice and 3D images of organs and vessels viewed from any perspective, with resolution better than 1 mm. MRI is perhaps most extraordinary and notable for the plethora of ways in which it can create unique forms of image contrast, reflective of fundamentally different biophysical phenomena. As with ultrasound, there is no risk from ionizing radiation to the patient or staff, since no X-rays or radioactive nuclei are involved. Instead, MRI harnesses magnetic fields and radio waves to probe the stable nuclei of the ordinary hydrogen atoms (isolated protons) occurring in water and lipid molecules within and around cells. MRI consists, in essence, of creating spatial maps of the electromagnetic environments around these hydrogen nuclei. Spatial variations in the proton milieus can be related to clinical differences in the biochemical and physiological properties and conditions of the associated tissues. Imaging of proton density (PD), and of the tissue proton spin relaxation times known as T1 and T2, all can reveal important clinical information, but they do so with approaches so dissimilar from one another that each is chosen for only certain clinical situations. T1 and T2 in a voxel are determined by different aspects of the rotations and other motions of the water and lipid molecules involved, as constrained by the local biophysical surroundings within and between its cells – and they, in turn, depend on the type of tissue and its state of health. Three other common applications of MRI exploit its capability to detect and image distinct movements of fluids: MR angiography (MRA), which rivals CT angiography but often requires no contrast medium, monitors the bulk flow of blood; functional MRI ( f MRI), distinguishes the perfusion of oxygenated blood from that of de-oxygenated, and lights up parts of the brain that are activated by a stimulus, rather like PET; and diffusion tensor imaging (DTI) indicates the diffusion of free water along tracts of axons, thereby bringing nerve trunks into view. There are variants on all of these themes, and on others as well. Magnetic Resonance Spectroscopy (MRS), for example, can perform non-invasive ‘virtual biopsies’ that allow identification of certain cancers and other lesions. And an MRI-guided needle biopsy can sample brain tissue from a region only millimeters in dimensions. MRI, however, involves deeper and more complex aspects of physics, technology, and biology than do most other imaging modalities, and it is widely considered to be correspondingly more difficult to learn. We could probably cover all of this rather comprehensively if we had 50 hours available rather than 2 ̶ but, to paraphrase a former Secretary of Defense, you tell your story in the time you have allotted. The four presenters and another physicist, Kevin King from GE, have combined their efforts to co-author a single slide show that describes essentials of MRI as simply as possible. It is obviously far from thorough, but hopefully it will succeed in explaining some of the basics in a simplified but still valid fashion; in providing a taste of the numerous capabilities and complexities of the modality; and in whetting your appetite to learn more. Part I. NMR, and Proton Density MRI of the 1D Patient (Wolbarst), begins with an introductory case study that illustrates a half dozen ways in which MRI provides valuable clinical information. It then explores the nuclear magnetic resonance (NMR) phenomenon, which underlies MRI. NMR can be introduced with either of two approaches. In the first, one thinks (loosely) of the nuclei of hydrogen atoms as (rotating and charged and therefore) magnetic objects, whose spin-axes tend to align in a strong external magnetic field, much like a compass needle. As with the Bohr atom, this spin-up/spin-down picture is a highly abridged version of the full quantum mechanical treatment, but still it leads to some useful, legitimate pictures of the NMR process occurring within a voxel: When RF photons of the correct (Larmor) frequency elevate protons in a fixed magnetic field out of their lower-energy spin state into the upper, the NMR phenomenon is indicated by the detectable absorption of RF power. With the addition of a linear gradient field along a multi-voxel, one-dimensional patient/phantom, as well, we can determine the water content of each compartment – an example of a real MRI study, albeit in 1D. Part I concludes with a discussion of the net magnetization at position x, m0(x), under conditions of dynamic thermal equilibrium, which leads into: Part II. Net Voxel Magnetization, m(x,t); T1-MRI; The MRI Device (Lemen), investigates the biophysics of the form of proton spin relaxation process characterized by the time T1. It then moves on to the creation of an MR image that displays the spatial variation in the values of this clinically relevant parameter, again in 1D. Finally, the design and workings of a clinical MRI machine are sketched, in preparation for: Part III. ‘Classical’ NMR; FID Imaging in 1D via k-Space (Yanasak) presents the second standard approach to NMR and MRI, the classical model. It focuses on the time dependence of the net nuclear magnetization, m(x,t), the overall magnetic field generated by the cohort of protons in the voxel at position x. Quite remarkably, this nuclear net magnetization itself acts in a strong magnetic field like a gyroscope in a gravitational field. This tack is better for explaining Free Induction Decay (FID), which involves a brief introduction to the Fourier transform and k-space. This leads to conventional Spin-Echo (S-E) reconstruction techniques for creating clinical images from raw data, and sets the stage for: Part IV. Spin-Echo; S-E / Spin Warp in a 2D Slice (Price) discusses application of the S- E sequence of radiofrequency pulses and gradient magnetic fields to the 1D patient. T2 is introduced but not explained. This Part also considers how to manipulate the image acquisition parameters so as to generate clinical pictures with contrast dominated by spatial variations in PD, T1, or T2. We conclude by demonstrating the spin-warp approach to imaging in 2D with a simple 2×2, 4-voxel example. Much of this material is presented in more detail in the chapter “MRI of the One-dimensional Patient, Part I”, in Advances in Medical Physics, Vol 5 (2014). Copies are on display at the Medical Physics Publishing booth. Learning Objectives: The participant will learn about the processes of NMR and T1 spin relaxation in a tissue voxel in a uniform magnetic field. The participant will learn about combining spin-up/spin-down NMR and T1 processes with a linear gradient to effect frequency-encoding of voxel spatial position. This approach can be used to create proton density and T1 MRI maps, respectively, of the contents of multi-voxel 1D phantoms. The participant will learn about how the ‘classical’ model of NMR it can generate Free Induction Decay (FID) images of 1D phantoms, which involves the use of the Fourier transform in k-space. This can lead simply into standard Spin-Echo images. The participant will learn about extending Spin-Echo imaging into 2 and more dimensions.

60 APPLIED LIFE SCIENCES↗

TU-EF-BRA-03: Free Induction Decay (without the Decay) and Spin-Echo Imaging

NMR, and Proton Density MRI of the 1D Patient - Anthony Wolbarst Net Voxel Magnetization, m(x,t). T1-MRI; The MRI Device - Lisa Lemen ‘Classical’ NMR; FID Imaging in 1D via k-Space - Nathan Yanasak Spin-Echo; S-E/Spin Warp in a 2D Slice - Ronald Price Magnetic resonance imaging not only reveals the structural, anatomic details of the body, as does CT, but also it can provide information on the physiological status and pathologies of its tissues, like nuclear medicine. It can display high-quality slice and 3D images of organs and vessels viewed from any perspective, with resolution better than 1 mm. MRI is perhaps most extraordinary and notable for the plethora of ways in which it can create unique forms of image contrast, reflective of fundamentally different biophysical phenomena. As with ultrasound, there is no risk from ionizing radiation to the patient or staff, since no X-rays or radioactive nuclei are involved. Instead, MRI harnesses magnetic fields and radio waves to probe the stable nuclei of the ordinary hydrogen atoms (isolated protons) occurring in water and lipid molecules within and around cells. MRI consists, in essence, of creating spatial maps of the electromagnetic environments around these hydrogen nuclei. Spatial variations in the proton milieus can be related to clinical differences in the biochemical and physiological properties and conditions of the associated tissues. Imaging of proton density (PD), and of the tissue proton spin relaxation times known as T1 and T2, all can reveal important clinical information, but they do so with approaches so dissimilar from one another that each is chosen for only certain clinical situations. T1 and T2 in a voxel are determined by different aspects of the rotations and other motions of the water and lipid molecules involved, as constrained by the local biophysical surroundings within and between its cells – and they, in turn, depend on the type of tissue and its state of health. Three other common applications of MRI exploit its capability to detect and image distinct movements of fluids: MR angiography (MRA), which rivals CT angiography but often requires no contrast medium, monitors the bulk flow of blood; functional MRI ( f MRI), distinguishes the perfusion of oxygenated blood from that of de-oxygenated, and lights up parts of the brain that are activated by a stimulus, rather like PET; and diffusion tensor imaging (DTI) indicates the diffusion of free water along tracts of axons, thereby bringing nerve trunks into view. There are variants on all of these themes, and on others as well. Magnetic Resonance Spectroscopy (MRS), for example, can perform non-invasive ‘virtual biopsies’ that allow identification of certain cancers and other lesions. And an MRI-guided needle biopsy can sample brain tissue from a region only millimeters in dimensions. MRI, however, involves deeper and more complex aspects of physics, technology, and biology than do most other imaging modalities, and it is widely considered to be correspondingly more difficult to learn. We could probably cover all of this rather comprehensively if we had 50 hours available rather than 2 ̶ but, to paraphrase a former Secretary of Defense, you tell your story in the time you have allotted. The four presenters and another physicist, Kevin King from GE, have combined their efforts to co-author a single slide show that describes essentials of MRI as simply as possible. It is obviously far from thorough, but hopefully it will succeed in explaining some of the basics in a simplified but still valid fashion; in providing a taste of the numerous capabilities and complexities of the modality; and in whetting your appetite to learn more. Part I. NMR, and Proton Density MRI of the 1D Patient (Wolbarst), begins with an introductory case study that illustrates a half dozen ways in which MRI provides valuable clinical information. It then explores the nuclear magnetic resonance (NMR) phenomenon, which underlies MRI. NMR can be introduced with either of two approaches. In the first, one thinks (loosely) of the nuclei of hydrogen atoms as (rotating and charged and therefore) magnetic objects, whose spin-axes tend to align in a strong external magnetic field, much like a compass needle. As with the Bohr atom, this spin-up/spin-down picture is a highly abridged version of the full quantum mechanical treatment, but still it leads to some useful, legitimate pictures of the NMR process occurring within a voxel: When RF photons of the correct (Larmor) frequency elevate protons in a fixed magnetic field out of their lower-energy spin state into the upper, the NMR phenomenon is indicated by the detectable absorption of RF power. With the addition of a linear gradient field along a multi-voxel, one-dimensional patient/phantom, as well, we can determine the water content of each compartment – an example of a real MRI study, albeit in 1D. Part I concludes with a discussion of the net magnetization at position x, m0(x), under conditions of dynamic thermal equilibrium, which leads into: Part II. Net Voxel Magnetization, m(x,t); T1-MRI; The MRI Device (Lemen), investigates the biophysics of the form of proton spin relaxation process characterized by the time T1. It then moves on to the creation of an MR image that displays the spatial variation in the values of this clinically relevant parameter, again in 1D. Finally, the design and workings of a clinical MRI machine are sketched, in preparation for: Part III. ‘Classical’ NMR; FID Imaging in 1D via k-Space (Yanasak) presents the second standard approach to NMR and MRI, the classical model. It focuses on the time dependence of the net nuclear magnetization, m(x,t), the overall magnetic field generated by the cohort of protons in the voxel at position x. Quite remarkably, this nuclear net magnetization itself acts in a strong magnetic field like a gyroscope in a gravitational field. This tack is better for explaining Free Induction Decay (FID), which involves a brief introduction to the Fourier transform and k-space. This leads to conventional Spin-Echo (S-E) reconstruction techniques for creating clinical images from raw data, and sets the stage for: Part IV. Spin-Echo; S-E / Spin Warp in a 2D Slice (Price) discusses application of the S- E sequence of radiofrequency pulses and gradient magnetic fields to the 1D patient. T2 is introduced but not explained. This Part also considers how to manipulate the image acquisition parameters so as to generate clinical pictures with contrast dominated by spatial variations in PD, T1, or T2. We conclude by demonstrating the spin-warp approach to imaging in 2D with a simple 2×2, 4-voxel example. Much of this material is presented in more detail in the chapter “MRI of the One-dimensional Patient, Part I”, in Advances in Medical Physics, Vol 5 (2014). Copies are on display at the Medical Physics Publishing booth. Learning Objectives: The participant will learn about the processes of NMR and T1 spin relaxation in a tissue voxel in a uniform magnetic field. The participant will learn about combining spin-up/spin-down NMR and T1 processes with a linear gradient to effect frequency-encoding of voxel spatial position. This approach can be used to create proton density and T1 MRI maps, respectively, of the contents of multi-voxel 1D phantoms. The participant will learn about how the ‘classical’ model of NMR it can generate Free Induction Decay (FID) images of 1D phantoms, which involves the use of the Fourier transform in k-space. This can lead simply into standard Spin-Echo images. The participant will learn about extending Spin-Echo imaging into 2 and more dimensions.

60 APPLIED LIFE SCIENCES↗

TU-EF-BRA-04: Into 2, 3, and 4 Dimensions

NMR, and Proton Density MRI of the 1D Patient - Anthony Wolbarst Net Voxel Magnetization, m(x,t). T1-MRI; The MRI Device - Lisa Lemen ‘Classical’ NMR; FID Imaging in 1D via k-Space - Nathan Yanasak Spin-Echo; S-E/Spin Warp in a 2D Slice - Ronald Price Magnetic resonance imaging not only reveals the structural, anatomic details of the body, as does CT, but also it can provide information on the physiological status and pathologies of its tissues, like nuclear medicine. It can display high-quality slice and 3D images of organs and vessels viewed from any perspective, with resolution better than 1 mm. MRI is perhaps most extraordinary and notable for the plethora of ways in which it can create unique forms of image contrast, reflective of fundamentally different biophysical phenomena. As with ultrasound, there is no risk from ionizing radiation to the patient or staff, since no X-rays or radioactive nuclei are involved. Instead, MRI harnesses magnetic fields and radio waves to probe the stable nuclei of the ordinary hydrogen atoms (isolated protons) occurring in water and lipid molecules within and around cells. MRI consists, in essence, of creating spatial maps of the electromagnetic environments around these hydrogen nuclei. Spatial variations in the proton milieus can be related to clinical differences in the biochemical and physiological properties and conditions of the associated tissues. Imaging of proton density (PD), and of the tissue proton spin relaxation times known as T1 and T2, all can reveal important clinical information, but they do so with approaches so dissimilar from one another that each is chosen for only certain clinical situations. T1 and T2 in a voxel are determined by different aspects of the rotations and other motions of the water and lipid molecules involved, as constrained by the local biophysical surroundings within and between its cells – and they, in turn, depend on the type of tissue and its state of health. Three other common applications of MRI exploit its capability to detect and image distinct movements of fluids: MR angiography (MRA), which rivals CT angiography but often requires no contrast medium, monitors the bulk flow of blood; functional MRI ( f MRI), distinguishes the perfusion of oxygenated blood from that of de-oxygenated, and lights up parts of the brain that are activated by a stimulus, rather like PET; and diffusion tensor imaging (DTI) indicates the diffusion of free water along tracts of axons, thereby bringing nerve trunks into view. There are variants on all of these themes, and on others as well. Magnetic Resonance Spectroscopy (MRS), for example, can perform non-invasive ‘virtual biopsies’ that allow identification of certain cancers and other lesions. And an MRI-guided needle biopsy can sample brain tissue from a region only millimeters in dimensions. MRI, however, involves deeper and more complex aspects of physics, technology, and biology than do most other imaging modalities, and it is widely considered to be correspondingly more difficult to learn. We could probably cover all of this rather comprehensively if we had 50 hours available rather than 2 ̶ but, to paraphrase a former Secretary of Defense, you tell your story in the time you have allotted. The four presenters and another physicist, Kevin King from GE, have combined their efforts to co-author a single slide show that describes essentials of MRI as simply as possible. It is obviously far from thorough, but hopefully it will succeed in explaining some of the basics in a simplified but still valid fashion; in providing a taste of the numerous capabilities and complexities of the modality; and in whetting your appetite to learn more. Part I. NMR, and Proton Density MRI of the 1D Patient (Wolbarst), begins with an introductory case study that illustrates a half dozen ways in which MRI provides valuable clinical information. It then explores the nuclear magnetic resonance (NMR) phenomenon, which underlies MRI. NMR can be introduced with either of two approaches. In the first, one thinks (loosely) of the nuclei of hydrogen atoms as (rotating and charged and therefore) magnetic objects, whose spin-axes tend to align in a strong external magnetic field, much like a compass needle. As with the Bohr atom, this spin-up/spin-down picture is a highly abridged version of the full quantum mechanical treatment, but still it leads to some useful, legitimate pictures of the NMR process occurring within a voxel: When RF photons of the correct (Larmor) frequency elevate protons in a fixed magnetic field out of their lower-energy spin state into the upper, the NMR phenomenon is indicated by the detectable absorption of RF power. With the addition of a linear gradient field along a multi-voxel, one-dimensional patient/phantom, as well, we can determine the water content of each compartment – an example of a real MRI study, albeit in 1D. Part I concludes with a discussion of the net magnetization at position x, m0(x), under conditions of dynamic thermal equilibrium, which leads into: Part II. Net Voxel Magnetization, m(x,t); T1-MRI; The MRI Device (Lemen), investigates the biophysics of the form of proton spin relaxation process characterized by the time T1. It then moves on to the creation of an MR image that displays the spatial variation in the values of this clinically relevant parameter, again in 1D. Finally, the design and workings of a clinical MRI machine are sketched, in preparation for: Part III. ‘Classical’ NMR; FID Imaging in 1D via k-Space (Yanasak) presents the second standard approach to NMR and MRI, the classical model. It focuses on the time dependence of the net nuclear magnetization, m(x,t), the overall magnetic field generated by the cohort of protons in the voxel at position x. Quite remarkably, this nuclear net magnetization itself acts in a strong magnetic field like a gyroscope in a gravitational field. This tack is better for explaining Free Induction Decay (FID), which involves a brief introduction to the Fourier transform and k-space. This leads to conventional Spin-Echo (S-E) reconstruction techniques for creating clinical images from raw data, and sets the stage for: Part IV. Spin-Echo; S-E / Spin Warp in a 2D Slice (Price) discusses application of the S- E sequence of radiofrequency pulses and gradient magnetic fields to the 1D patient. T2 is introduced but not explained. This Part also considers how to manipulate the image acquisition parameters so as to generate clinical pictures with contrast dominated by spatial variations in PD, T1, or T2. We conclude by demonstrating the spin-warp approach to imaging in 2D with a simple 2×2, 4-voxel example. Much of this material is presented in more detail in the chapter “MRI of the One-dimensional Patient, Part I”, in Advances in Medical Physics, Vol 5 (2014). Copies are on display at the Medical Physics Publishing booth. Learning Objectives: The participant will learn about the processes of NMR and T1 spin relaxation in a tissue voxel in a uniform magnetic field. The participant will learn about combining spin-up/spin-down NMR and T1 processes with a linear gradient to effect frequency-encoding of voxel spatial position. This approach can be used to create proton density and T1 MRI maps, respectively, of the contents of multi-voxel 1D phantoms. The participant will learn about how the ‘classical’ model of NMR it can generate Free Induction Decay (FID) images of 1D phantoms, which involves the use of the Fourier transform in k-space. This can lead simply into standard Spin-Echo images. The participant will learn about extending Spin-Echo imaging into 2 and more dimensions.

60 APPLIED LIFE SCIENCES↗

Glancing-incidence focussed ion beam milling: A coherent X-ray diffraction study of 3D nano-scale lattice strains and crystal defects

Here, this study presents a detailed examination of the lattice distortions introduced by glancing incidence Focussed Ion Beam (FIB) milling. Using non-destructive multi-reflection Bragg coherent X-ray diffraction we probe damage formation in an initially pristine gold micro-crystal following several stages of FIB milling. These experiments allow access to the full lattice strain tensor in the micro-crystal with ~25 nm 3D spatial resolution, enabling a nano-scale analysis of residual lattice strains and defects formed. Our results show that 30 keV glancing incidence milling produces fewer large defects than normal incidence milling at the same energy. However the resulting residual lattice strains have similar magnitude and extend up to ~50 nm into the sample. At the edges of the milled surface, where the ion-beam tails impact the sample at near-normal incidence, large dislocation loops with a range of Burgers vectors are formed. Further glancing incidence FIB polishing with 5 keV ion energy removes these dislocation loops and reduces the lattice strains caused by higher energy FIB milling. However, even at the lower ion energy, damage-induced lattice strains are present within a ~20 nm thick surface layer. These results highlight the need for careful consideration and management of FIB damage. They also show that low-energy FIB-milling is an effective tool for removing FIB-milling induced lattice strains. This is important for the preparation of micro-mechanical test specimens and strain microscopy samples.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Spectroscopic Signatures of Phonon Character in Molecular Electron Spin Relaxation

Spin–lattice relaxation constitutes a key challenge for the development of quantum technologies, as it destroys superpositions in molecular quantum bits (qubits) and magnetic memory in single molecule magnets (SMMs). Gaining mechanistic insight into the spin relaxation process has proven challenging owing to a lack of spectroscopic observables and contradictions among theoretical models. Here, we use pulse electron paramagnetic resonance (EPR) to profile changes in spin relaxation rates (T 1 ) as a function of both temperature and magnetic field orientation, forming a two-dimensional data matrix. For randomly oriented powder samples, spin relaxation anisotropy changes dramatically with temperature, delineating multiple regimes of relaxation processes for each Cu(II) molecule studied. We show that traditional T 1 fitting approaches cannot reliably extract this information. Single-crystal T 1 anisotropy experiments reveal a surprising change in spin relaxation symmetry between these two regimes. We interpret this switch through the concept of a spin relaxation tensor, enabling discrimination between delocalized lattice phonons and localized molecular vibrations in the two relaxation regimes. Variable-temperature T 1 anisotropy thus provides a unique spectroscopic method to interrogate the character of nuclear motions causing spin relaxation and the loss of quantum information.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Seismic anisotropy of serpentinite from Val Malenco, Italy

Serpentinites, deformed in mantle subduction zones, are thought to contribute significantly to seismic anisotropy of the upper mantle and have therefore been of great interest with studies on deformation, preferred orientation, and elastic properties. Here we present a combined study of a classical sample from Val Malenco, Italy, investigating the microstructure and texture with state-of-the art synchrotron X-ray and neutron diffraction methods and measuring ultrasonic velocities both with a multi-anvil apparatus and a novel instrument to measure 3-D velocities on spheres. Both, results from diffraction methods and velocity measurements are compared, discussing advantages and disadvantages. From spherical velocities, elastic tensor properties can be derived by inversion. Also from quantitative texture measurements, elastic properties can be modeled by self-consistent averaging. We report good agreement between the velocity and microstructural models is observed.

58 GEOSCIENCES↗

Density-Matrix Based Extended Lagrangian Born–Oppenheimer Molecular Dynamics

Extended Lagrangian Born–Oppenheimer molecular dynamics [ Phys. Rev. Lett. 2008, 100, 123004] is presented for Hartree–Fock theory, where the extended electronic degrees of freedom are represented by a density matrix, including fractional occupation numbers at elevated electronic temperatures. In contrast to regular direct Born–Oppenheimer molecular dynamics simulations, no iterative self-consistent field optimization is required prior to the force evaluations. To sample regions of the potential energy landscape where the gap is small or vanishing, which leads to particular convergence problems in regular direct Born–Oppenheimer molecular dynamics simulations, an adaptive integration scheme for the extended electronic degrees of freedom is presented. The integration scheme is based on a tunable, low-rank approximation of a fourth-order kernel, K, that determines the metric tensor, T ≡ K T K, used in the extended harmonic oscillator of the Lagrangian that generates the dynamics of the electronic degrees of freedom. Here, the formulation and algorithms provide a general guide to implement extended Lagrangian Born–Oppenheimer molecular dynamics for quantum chemistry, density functional theory, and semiempirical methods using a density matrix formalism.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Physics-informed machine learning of the Lagrangian dynamics of velocity gradient tensor

Reduced models describing the Lagrangian dynamics of the velocity gradient tensor (VGT) in homogeneous isotropic turbulence (HIT) are developed under the physics-informed machine learning (PIML) framework. We consider the VGT at both Kolmogorov scale and coarse-grained scale within the inertial range of HIT. Building reduced models requires resolving the pressure Hessian and subfilter contributions, which is accomplished by constructing them using the integrity bases and invariants of the VGT. The developed models can be expressed using the extended tensor basis neural network (TBNN) introduced by Ling et al. [J. Fluid Mech. 807, 155 (2016)]. Physical constraints, such as Galilean invariance, rotational invariance, and incompressibility condition, are thus embedded in the models explicitly. Our PIML models are trained on the Lagrangian data from a high-Reynolds number direct numerical simulation (DNS). To validate the results, we perform a comprehensive out-of-sample test. We observe that the PIML model provides an improved representation for the magnitude and orientation of the small-scale pressure Hessian contributions. Statistics of the flow, as indicated by the joint PDF of second and third invariants of the VGT, show good agreement with the “ground-truth” DNS data. A number of other important features describing the structure of HIT are reproduced by the model successfully. We have also identified challenges in modeling inertial range dynamics, which indicates that a richer modeling strategy is required. This helps us identify important directions for future research, in particular towards including inertial range geometry into the TBNN.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Statistical analysis of near-wall structures in turbulent channel flow

The two-point correlation tensor is used to analyze near-wall structures in turbulent channel flow. Simulation results have been utilized to obtain the correlation tensor with sufficient spatial resolution to permit accurate differentiation for computing the vorticity correlation, and the resolution of sharp features such as the shear layer and its corresponding region of spanwise vorticity. Proper orthogonal decomposition and stochastic estimation were observed to yield similar results when appropriate conditions were employed for the estimation. Resulting structures were such that they would be detected by standard conditional sampling methods. The results of decomposing the vorticity field and the velocity field were significantly different, indicating that if a coherent structure is found that dominates the velocity fields, the curl of that velocity structure will not dominate the vorticity field.

Moser, Robert D.↗

BiFeO(3): Synchrotron Radiation Structure Refinement And Magnetoelectric Geometry

Presently BiFeO{sub 3} focuses attention due to its multiferroic nature. This phase shows a highly distorted perovskite crystal structure, with R3c crystal symmetry. Details of the crystallographic structure are required input for a detailed explanation of its remarkable magnetoelectric properties. Present report contributes a high-resolution synchrotron radiation diffraction analysis of the BiFeO{sub 3} crystal structure. Single-phased sample was obtained by conventional solid-state reaction under bismuth atmosphere. XRD experiment was performed on beamline 2-1, Stanford Synchrotron Radiation Laboratory, with 12 keV X-rays. For data Rietveld processing, Fullprof software package was applied. Obtained cell parameters (in {angstrom}, hexagonal system description) were a = 5.57414(4); c = 13.85882(12). Group-theoretical analysis of BiFeO{sub 3} linear magnetoelectric tensor is presented. Only transverse effect is allowed by symmetry. Axial-symmetry polycrystal ceramics cannot show linear magnetoelectric coupling.

36 MATERIALS SCIENCE↗

Random insights into the complexity of two-dimensional tensor network calculations

Projected entangled pair states (PEPS) offer memory-efficient representations of some quantum many-body states that obey an entanglement area law and are the basis for classical simulations of ground states in two-dimensional (2d) condensed matter systems. However, rigorous results show that exactly computing observables from a 2d PEPS state is generically a computationally hard problem. Yet approximation schemes for computing properties of 2d PEPS are regularly used, and empirically seen to succeed, for a large subclass of (“not too entangled”) condensed matter ground states. Adopting the philosophy of random matrix theory, in this work, we analyze the complexity of approximately contracting a 2d random PEPS by exploiting an analytic mapping to an effective replicated statistical mechanics model that permits a controlled analysis at a large bond dimension. Through this statistical-mechanics lens, we argue that (i) although approximately sampling wave-function amplitudes of random PEPS faces a computational-complexity phase transition above a critical bond dimension, and (ii) one can generically efficiently estimate the norm and correlation functions for any finite bond dimension. Furthermore, these results are supported numerically for various bond-dimension regimes. It is an important open question whether the above results for random PEPS apply more generally also to PEPS representing physically relevant ground states.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Gravity dual for a model of perception

One of the salient features of human perception is its invariance under dilatation in addition to the Euclidean group, but its non-invariance under special conformal transformation. We investigate a holographic approach to the information processing in image discrimination with this feature. We claim that a strongly coupled analogue of the statistical model proposed by Bialek and Zee can be holographically realized in scale invariant but non-conformal Euclidean geometries. We identify the Bayesian probability distribution of our generalized Bialek-Zee model with the GKPW partition function of the dual gravitational system. We provide a concrete example of the geometric configuration based on a vector condensation model coupled with the Euclidean Einstein-Hilbert action. From the proposed geometry, we study sample correlation functions to compute the Bayesian probability distribution.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A non-hybrid method for the PDF equations of turbulent flows on unstructured grids

In probability density function (PDF) methods of turbulent flows, the joint PDF of several flow variables is computed by numerically integrating a system of stochastic differential equations for Lagrangian particles. A set of parallel algorithms is proposed to provide an efficient solution of the PDF transport equation modeling the joint PDF of turbulent velocity, frequency and concentration of a passive scalar in geometrically complex configurations. In the vicinity of walls the flow is resolved by an elliptic relaxation technique down to the viscous sublayer, explicitly modeling the high anisotropy and inhomogeneity of the low-Reynolds-number wall region without damping or wall-functions. An unstructured Eulerian grid is employed to extract Eulerian statistics, to solve for quantities represented at fixed locations of the domain (i.e., the mean pressure and the elliptic relaxation tensor) and to track particles. All three aspects regarding the grid make use of the finite element method employing the simplest linear shapefunctions. To model the small-scale mixing of the transported scalar, the interaction by exchange with the conditional mean (IECM) model is adopted. An adaptive algorithm to compute the velocity-conditioned scalar mean is proposed that homogenizes the statistical error over the sample space with no assumption on the shape of the underlying velocity PDF. Compared to other hybrid particle-in-cell approaches for the PDF equations, the current methodology is consistent without the need for consistency conditions. The algorithm is tested by computing the dispersion of passive scalars released from concentrated sources in two different turbulent flows: the fully developed turbulent channel flow and a street canyon (or cavity) flow. Algorithmic details on estimating conditional and unconditional statistics, particle tracking and particle-number control are presented in detail. Relevant aspects of performance and parallelism on cache-based shared memory machines are discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Small-angle neutron polarimetry apparatus (SANPA): Development at the NIST Center for Neutron Research

Spherical neutron polarimetry directly measures the rotation of the neutron polarization after scattering from materials with magnetic structure. It is an under utilized measurement technique that is capable of measuring all nine elements of the polarization tensor of a material. In this article, we describe our new cryogen-free small-angle neutron polarimetry apparatus and infrastructure at the NIST Center for Neutron Research. The resulting apparatus is capable of continuous operation and is designed for measurements at low temperatures (4–8 K) using niobium Meissner shielding and mu-metal shielding to produce a zero-field (≤1 μT) cooling sample environment.

47 OTHER INSTRUMENTATION↗

Rescuing quadratic inflation

Inflationary models based on a single scalar field φ with a quadratic potential V = ½m{sup 2}φ{sup 2} are disfavoured by the recent Planck constraints on the scalar index, n{sub s}, and the tensor-to-scalar ratio for cosmological density perturbations, r{sub T}. In this paper we study how such a quadratic inflationary model can be rescued by postulating additional fields with quadratic potentials, such as might occur in sneutrino models, which might serve as either curvatons or supplementary inflatons. Introducing a second scalar field reduces but does not remove the pressure on quadratic inflation, but we find a sample of three-field models that are highly compatible with the Planck data on n{sub s} and r{sub T}. We exhibit a specific three-sneutrino example that is also compatible with the data on neutrino mass difference and mixing angles.

79 ASTRONOMY AND ASTROPHYSICS↗

Near-Efficient and Non-Asymptotic Multiway Inference

We establish non-asymptotic efficiency guarantees for tensor decomposition–based inference in count data models. Under a Poisson framework, we consider two related goals: (i) parametric inference , the estimation of the full distributional parameter tensor, and (ii) multiway analysis , the recovery of its canonical polyadic (CP) decomposition factors. Our main result shows that in the rank-one setting, a rank-constrained maximum-likelihood estimator achieves multiway analysis with variance matching the Cramér–Rao Lower Bound (CRLB) up to absolute constants and logarithmic factors. This provides a general framework for studying “near-efficient” multiway estimators in finite-sample settings. For higher ranks, we illustrate that our multiway estimator may not attain the CRLB; nevertheless, CP-based parametric inference remains nearly minimax optimal, with error bounds that improve on prior work by offering more favorable dependence on the CP rank. Numerical experiments corroborate near-efficiency in the rank-one case and highlight the efficiency gap in higher-rank scenarios.

97 MATHEMATICS AND COMPUTING↗

Recent Advancements in the PATO Material Response Code

Introduction: Predicting the complicated multiphysics phenomena during atmospheric entry requires high-fidelity modeling tools to refine estimates of mission risks during entry. To this end, new capabilities are being added to the Porous-material Analysis Toolbox based on OpenFOAM (PATO). PATO is an open-source software for Computational Material Response (CMR) of reactive porous materials submitted to high-temperature environments. The objective of this work is to highlight current efforts to add to and improve upon the modeling capabilities of PATO. These include efforts to loosely couple PATO with other discipline specialized codes including hypersonic Computational Fluid Dynamics (CFD), to assess the interaction effects between pyrolysis gas blowing and the boundary layer, and Computational Solid Mechanics (CSM), to address modeling of mechanical erosion. Other refinements include surface phenomena modeling capabilities to address the effects of silicone-based coatings applied to the TPS during flight preparation, and a unified multiphase solver for a mixed porous-material and plain-fluid domain. Coupling CMR with CFD (CMR/CFD): A loose coupling between PATO and the Data Parallel Line Relaxation (DPLR) CFD code has been achieved by making use of a blowing boundary condition at the heatshield surface available in DPLR. Starting with heat flux estimates with no pyrolysis gas blowing at the surface, blowing gases are computed by the CMR and passed to the CFD such that aerothermal properties of the environment can be recomputed for a new CMR computation. This leads to an iterative process which is supplemented with an estimate of the radiative heat flux using the Nonequilibrium air radiation (NEQAIR) program. The entire iterative process is illustrated in Figure 1. This coupling strategy has been utilized in computing the MSL material response. The goal is to compare the coupled CMR/CFD results with material response results obtained using traditional blowing corrections. Coupling CMS with CMR: A mechanical erosion model is currently being implemented in PATO to account for the additional mass removal induced by high shear conditions. The modeling process at each timestep consists of updating the mechanical properties as a function of temperature and computing the stress tensor and displacement fields of the material. Then, a failure criteria model determines the regions in which the stress exceeds the ultimate strength values resulting in mesh movement to account for mass removal. This model allows the material response simulation to compute the recession due to both oxidation and shear-induced erosion. The model is demonstrated by computing material response of sphere-cone arc jet samples. Surface Modeling Capabilities: NuSil, a silicone-based coating, was sprayed onto the MSL and Mars 2020 heatshields to mitigate shedding of phenolic dust. To better understand the effects of the NuSil coating on the material response, a novel model has been implemented in PATO. In this model, the equilibrium of the charred NuSil surface is modeled as pure silica, and a constant offset, inspired by the classical spallation model, is added to the the char blowing rate and wall enthalpy to reproduce HyMETS experimental results. The model has also been used to estimate the 3D material response of the MSL heatshield. Unified Solver: In addition to the iterative loose coupling approach mentioned above, a multiphase unified solver is being developed to couple the environment (plain-fluid phase) and the porous-material phase. The solver is based on the volume averaged conservation of mass, momentum, and energy for the macroscale with closure models which include microscale effects through effective physicochemical properties. The unified solver has been used to compute flow through a porous plug and solve the Beavers and Joseph problem. Since the strong coupling between phases is inherent to this solver, modeling assumptions present in other coupling methods of material response are mitigated. This strategy also makes it feasible to capture the competition between surface and volume ablation in the same computational domain, which is usually not possible with other coupling approaches.

Material Response↗

Recent Advancements in the PATO Material Response Code

Introduction: Predicting the complicated multiphysics phenomena during atmospheric entry requires high-fidelity modeling tools to refine estimates of mission risks during entry. To this end, new capabilities are being added to the Porous-material Analysis Toolbox based on OpenFOAM (PATO) [1,2,3]. PATO is an open-source software for Computational Material Response (CMR) of reactive porous materials submitted to high-temperature environments. The objective of this work is to highlight current efforts to add to and improve upon the modeling capabilities of PATO. These include efforts to loosely couple PATO with other discipline specialized codes including hypersonic Computational Fluid Dynamics (CFD), to assess the interaction effects between pyrolysis gas blowing and the boundary layer, and Computational Solid Mechanics (CSM), to address modeling of mechanical erosion. Other refinements include surface phenomena modeling capabilities to address the effects of silicone-based coatings applied to the TPS during flight preparation, and a unified multiphase solver for a mixed porous-material and plain-fluid domain. Coupling CMR with CFD (CMR/CFD): A loose coupling between PATO and the Data Parallel Line Relaxation (DPLR) [4] CFD code has been achieved by making use of a blowing boundary condition at the heatshield surface available in DPLR. Starting with heat flux estimates with no pyrolysis gas blowing at the surface, blowing gases are computed by the CMR and passed to the CFD such that aerothermal properties of the environment can be recomputed for a new CMR computation. This leads to an iterative process which is supplemented with an estimate of the radiative heat flux using the Nonequilibrium air radiation (NEQAIR) [5] program. The entire iterative process is illustrated in Figure 1. This coupling strategy has been utilized in computing the MSL material response. The goal is to compare the coupled CMR/CFD results with material response results obtained using traditional blowing corrections. Coupling CMS with CMR: A mechanical erosion model is currently being implemented in PATO to account for the additional mass removal induced by high shear conditions. The modeling process at each timestep consists of updating the mechanical properties as a function of temperature and computing the stress tensor and displacement fields of the material. Then, a failure criteria model determines the regions in which the stress exceeds the ultimate strength values resulting in mesh movement to account for mass removal. This model allows the material response simulation to compute the recession due to both oxidation and shear-induced erosion. The model is demonstrated by computing material response of sphere-cone arc jet samples. Surface Modeling Capabilities: NuSil, a silicone-based coating, was sprayed onto the MSL and Mars 2020 heatshields to mitigate shedding of phenolic dust. To better understand the effects of the NuSil coating on the material response, a novel model has been implemented in PATO. In this model, the equilibrium of the charred NuSil surface is modeled as pure silica, and a constant offset, inspired by the classical spallation model, is added to the the char blowing rate and wall enthalpy to reproduce HyMETS experimental results. The model has also been used to estimate the 3D material response of the MSL heatshield [6]. Unified Solver: In addition to the iterative loose coupling approach mentioned above, a multiphase unified solver is being developed to couple the environment (plain-fluid phase) and the porous-material phase. The solver is based on the volume averaged conservation of mass, momentum, and energy for the macroscale with closure models which include microscale effects through effective physicochemical properties. The unified solver has been used to compute flow through a porous plug and solve the Beavers and Joseph problem [7]. Since the strong coupling between phases is inherent to this solver, modeling assumptions present in other coupling methods of material response are mitigated. This strategy also makes it feasible to capture the competition between surface and volume ablation in the same computational domain, which is usually not possible with other coupling approaches.

Thermal Protection Systems↗