Search NASA⌕ Search

SEARCH · Search NASA

Results for “test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Optimizing resource allocation in Miscanthus breeding via sparse testing designs for genomic prediction

Phenotyping high-biomass perennial crops is laborious and the rate of genetic gain in conventional perennial crop breeding programs is typically low. So, it is especially important to identify methods that produce efficiency gains in the breeding process. Miscanthus is a C4 perennial grass with favorable characteristics for producing biomass as a feedstock for biofuels and diverse bio-based products. Increasing biomass yield will increase profitability and environmental benefits, so it is a key target for Miscanthus breeding. In addition, the identification of well-adapted genotypes across a wide range of environmental conditions requires the establishment of multi-environment trials (METs). Sparse testing is a genomic prediction-based strategy that reduces the phenotyping costs in METs by selecting a subset of genotypes to evaluate in a subset of environments and then predicts the performance of the unobserved genotype-environment combinations. A Miscanthus sacchariflorus (MSA) population comprising 336 genotypes observed across three environments was analyzed implementing sparse testing designs. Three prediction models considering main effects (environments, genotypes, genomic) and interaction effects (genotype-by-environment; G×E interaction) were implemented for forecasting dry biomass yield (YDY), total culm (TCM), average internode length (AIL), and culm node number (CNN). Multiple calibration sets based on different compositions and sizes were considered to evaluate performance in terms of the predictive ability (PA) and the mean square error (MSE) for a fixed testing set size. The training set size ranged from 52 to 112 to predict a fixed set of 224 unobserved genotypes across all three environments. The results showed that the model accounting for G×E interaction consistently presented the highest PA and the lowest MSE: for CNN (PA: ~0.77, MSE: ~0.5) and YDY (PA: ~0.70, MSE: ~1.3) while for TCM and AIL these ranged from ~0.28 to 0.41 and ~1.3 to 4.3, respectively. Overall, varying training sets and allocation strategies did not affect PA and MSE, with 52 non-overlapping and 0 overlapping genotypes per environment as the optimal cost-effective allocation framework. This suggests that implementing sparse testing designs could significantly reduce phenotyping costs by fivefold, without compromising PA in breeding programs for perennial crops such as Miscanthus.

Miscanthus sacchariflorus (MSA)↗

UNCERTAINTIES FOR IN-REACTOR TESTING OF TRITIUM LOADED GETTERS WITH TEMPERATURE CONTROL

The fourth experiment in TPBAR Materials Irradiation Separate-Effects Test (TMIST) series (TMIST-4) is planned to experimentally determine the effect of neutron irradiation on the equilibrium vapor pressure of tritium over a tritium loaded Nickel-Plated Zirconium (NPZ) getter in a simulated TPBAR service environment. This pressure will be used to estimate the tritium permeation rate. In the thermal design in the TMIST-4, two evaluations are required. 1) The cladding temperature is calculated to estimate the feasibility of detecting potential irradiation enhancement of the partial pressure for an NPZ getter. This work is required to obtain a precise cladding temperature for measurement of a low tritium partial pressure. This work has been completed and indicated that the required/target cladding temperatures based on the TMIST-4 test plan can be satisfied under the test condition range by modifying the capsule component shapes and inserting a thermally conductive metal sleeve. 2) The evaluation of uncertainties associated with the test design and operation is performed. This includes fabrication tolerances, and power and nuclear operating conditions. These factors will impact the component temperatures inside capsules and resulting the tritium partial pressure. The tritium permeation rate is a function of temperature and tritium partial pressure. The prediction of tritium permeation rates affects the feasibility of obtaining measurement resolutions required to reach reasonable conclusion for potential irradiation enhanced performance. This work will investigate the uncertainties.

TTP, TPBAR, TMIST-4, TPBAR Materials Irradiation S↗

Comparative Analysis of Heat Exchangers for High Temperature High Pressure Helium Component Testing

Helium gas loops have been designed and built to gain a better understanding of the gas thermohydraulic phenomena that take place in a helium system. Some of these loops are used for validation and testing of components for high temperature gas-cooled reactors (HTGRs). However, most of them operate at lower pressure and temperature than an HTGR. While these loops can provide valuable information about gas-cooled reactor components, the operating envelope of the experiment is constrained by the maximum operating conditions of the helium loop. In response to the lack of an experimental facility that can provide the infrastructure needed to validate and test components at nominal pressures and temperatures of HTGRS, the HElium Component Testing Out-of-pile Research (HECTOR) facility was designed at Idaho National Laboratory with the assistance of University of Idaho and Walsh Engineering. With the capability to test at temperatures up to 800°C and pressures of 8MPa, HECTOR serves as a critical tool for the advancement of HTGR technology. The facility's primary role is to provide a controlled, high-fidelity environment for the assessment of component resilience and efficiency under nominal HTGR conditions. In the quest to enhance the efficiency and performance of HECTOR, a comparative analysis of three distinct types of heat exchangers—shell and tube, offset strip fin, and printed-circuit—was conducted, focusing primarily on two critical metrics: the required surface area and pressure drop characteristics. The shell and tube heat exchanger, renowned for its robust design and widespread industrial application, was evaluated against the offset strip fin and the cuttingedge printed-circuit heat exchangers, both of which are lauded for their compactness and thermal effectiveness. This comparative study aims to provide detailed insights into the thermal management capabilities of each heat exchanger type under the conditions inherent to HECTOR, thereby facilitating an informed selection for systems demanding high operational integrity and efficiency.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Post-irradiation 1600°C Heating Test of AGR-1 UCO Fuel Kernels

Five bare kernels were selected from the U.S. Advanced Gas Reactor (AGR) 1 irradiation experiment Compact 5-3-1 to perform post-irradiation safety tests. The safety test involved heating the kernels in the Fuel Accident Condition Simulator (FACS) furnace in the inert atmosphere to a peak temperature of 1600°C and isothermally holding at this temperature for about 47 hours while collecting fission products released. This test was to assess the retention of fission products in bare kernels without the effects of the other TRISO layers (buffer, IPyC, SiC, and OPyC) or the graphitic matrix material. The bare kernels released nearly 100% of cesium and antimony, while they were able to maintain about 30% of europium, 50% of strontium, and the majority of cerium and ruthenium. In addition, about 48% of the calculated inventory of Kr-85 released during the test, indicating that kernels were capable of retaining a considerable fraction of fission gas K-85 during irradiation.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Advanced Conductor Testing – 824 kcmil 26/19 ACCR 3M

This report discusses the advanced conductor testing of 3M's ACCR conductor. The testing included exposure to wildfire temperatures and subsequent ultimate tensile strength tests.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Test–retest reliability for a social discounting of personal information task

Increasing cybercrime rates means identifying potential victims is critically important. Social discounting tasks show that individuals share less personally identifying information as social distance increases. However, the test–retest reliability and uniqueness of this measure is unclear. The current study assessed social discounting for personally identifying information (SDPII), delay discounting, risk taking, and personality at two measurement waves 30 days apart for 64 undergraduate students. Test–retest reliability was statistically significant for the SDPII and all other measures, replicating previous studies. SDPII rates were not significantly correlated with other measures during both measurement waves, showing discriminant validity. SDPII rates were lower than those reported in a previous study but were still well described by a hyperbolic discounting function, suggesting replicability across studies. Furthermore, the high test–retest reliability, uniqueness, and replicability of the SDPII suggests that it may quantitatively identify cybercrime victimization. Future research should test which measure or combination of measures can accurately predict scam and cybercrime victimization to inform data-based interventions.

99 GENERAL AND MISCELLANEOUS↗

The AGN-201 Digital Twin: A test bed for remotely monitoring nuclear reactors

Research reactors have historically provided researchers and scientists with a means for testing and understanding the workings of nuclear phenomena. With the lack of new research reactors built in the past decades, it is important now more than ever to utilize and provide evidence for the usefulness of research reactors. Here, this work explores the use of the AGN-201 research reactor at Idaho State University as a test bed for developing a digital twin (named the AGN-201 DT) to realize remote monitoring for nuclear reactors. The goal of the AGN-201 DT is to monitor the AGN-201 reactor and detect when undeclared events take place to provide information for a monitoring agency. The AGN-201 DT was able to detect (without a priori knowledge) when multiple undeclared experiments were placed in the core using on-the-fly machine learning and reactor physics analysis. The AGN-201 reactor provided a test bed for developing, deploying, and testing a digital twin for monitoring nuclear reactors.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Long-Term field testing of the accuracy and HVAC energy savings potential of occupancy presence sensors in A Single-Family home

The energy-saving potential of occupancy-centric smart thermostats has been extensively explored in simulations but lacked field testing for energy savings quantification and sensor performance assessment in real buildings. This paper presents a long-term field study conducted in a single-family home in Texas, U.S. to evaluate the performance of occupancy-centric controls (OCC) of HVAC (heating, ventilation, and air-conditioning) system in terms of energy savings, sensor accuracy, and impact on electric peak demand. The test site was equipped with a commercial off-the-shelf (COTS) smart thermostat and multiple occupancy presence sensors for OCC implementation. Additionally, a sub-metering system was installed to monitor electricity consumption of various end-use equipment, including the HVAC system. A supplementary device was installed to track the ground-truth occupancy for the accuracy evaluation of the occupancy presence sensor. Scenarios of baseline and OCC controls were alternated weekly over the 20-month testing period. The results indicated an effective OCC execution, as evidenced by indoor temperature profiles. During the 2023 cooling season, OCC achieved total energy savings of 1,958 kWh, corresponding to a 17.6% energy savings ratio. Under certain conditions, daily HVAC energy savings reached as high as 17 kWh, with a savings ratio of 35%. Sensor performance showed an overall accuracy of 83.8%, a False Positive Rate (FPR) of 12.8%, and a False Negative Rate (FNR) of 47.4%. A key limitation was the sensor’s inability to detect stationary occupants during sleep, leading to a midnight FNR of nearly 100% and significantly compromising thermal comfort. Additionally, the implementation of OCC resulted in extended periods of high electricity demand on summer afternoons, affecting occupant’s thermal comfort and posing potential challenges to community-level grid operations if OCC were widely adopted. Furthermore, this study addresses a critical research gap by empirically investigating energy-saving potential and occupancy sensor performance in residential buildings. Through a comprehensive field-testing study, the research examines the interrelationship between sensor accuracy, energy savings, and thermal comfort, an area that has received limited attention in the current literature.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Comprehensive evaluation of commercially scalable atomic-layer-deposited alumina coating impact on full cell battery performance across varied test conditions

Atomic Layer Deposition (ALD) has emerged as a strategic enhancement method for lithium-ion battery (LIB) materials offering potential benefits and durability benefits for industrial battery production. However, the translation from laboratory achievements to commercial-scale applications has been limited. Here, this study aims to bridge this gap by comprehensively evaluating the effects of commercially scalable Al 2 O 3 ALD coatings using full pouch cell performance as a means to assess the ALD impact. We utilized large-scale slot-die coating techniques to ensure consistent electrode quality and tested four configurations of pouch cells to analyze the individual effects of ALD coating on anode and cathode electroactive materials. Our extensive testing matrix included long-term cycling, fast discharge, fast charge, leakage current, and high voltage tests. While at lower C-rates (<~1C), the influence of Al 2 O 3 coatings on cell performance is not significant. Fast charging conditions reveal that the anode ALD coating significantly enhances performance via a passivating effect, while on the cathode, it is detrimental, potentially due to increased resistance of the thin interfacial layer formed during the ALD processing. Leakage current and high-voltage tests show that the application of ALD coatings on either anode or cathode effectively minimizes side reactions at the electrode-electrolyte interface. Additionally, ALD coatings significantly mitigate concentrated and localized lithium plating on the anodes. These insights provide a valuable understanding of the potential of ALD technologies in LIB manufacturing to tailor cell performance, paving the way for safer, more efficient, and cost-effective battery solutions.

25 ENERGY STORAGE↗

Ultra-high temperature testing and performance of L-PBF C103

Additive Manufacturing (AM) of refractory alloys is gaining traction as a materials processing route for components subject to extreme temperature environments. Due to the low oxidation resistance of refractory alloys, novel methods for evaluating their elevated temperature performance must be developed. In this work, a Gleeble® 3800 thermomechanical load frame was modified to evaluate the mechanical properties of laser powder bed fusion (L-PBF) consolidated niobium alloy C103 ranging from room temperature (RT) to 1400 °C. The fixturing and sample geometry were designed to accommodate Joule heating and prevent damage to the test chamber. Oxidation of the samples was minimized via testing in vacuum level of 1E-5 Torr. Ultimate tensile strength (UTS), yield strength (YS), elongation, and strain-hardening behavior were determined as a function of temperature. L-PBF C103 presented an average UTS of ∼650 MPa and over 25 % elongation at RT. Above RT, the UTS and YS dropped then leveled off from 500 °C to 1000 °C with values ranging from ∼400 MPa to ∼460 MPa, which is consistent with dynamic strain aging observed in this class of alloys. The strength rapidly declined after 1200 °C to ∼150 MPa at 1400 °C. Fractography indicated ductile fractures for the C103 at all test temperatures, and Electron Backscatter Diffraction (EBSD) analysis revealed a textured microstructure and the presence of dynamic recrystallization within the necked region of the sample tested at 1400 °C.

33 ADVANCED PROPULSION SYSTEMS↗

Interpreting accelerated tests on perovskite modules using photooxidation of MAPbI 3 as an example

Solar panels (modules) based on metal halide perovskites are following a fast track to commercialization. Unlike more established solar cell materials, there are not yet decades-long field observations to increase consumer confidence. The "physics and chemistry of failure" approach is used in other industries and estimates product degradation based on laboratory accelerated tests integrated with an understanding of degradation mechanisms. This work uses that approach to quantify the relationship between accelerated tests and projected product behavior for metal halide perovskite modules. Degradation involving photooxidation of methylammonium lead iodide is used to illustrate the method. Acceleration factors in common accelerated tests are found to be low. Conclusions emphasize that the accelerated tests on photovoltaics should not be interpreted as equivalent across module types or as a green light for commercialization unless supported by the appropriate field data or physics and chemistry of failure analysis.

14 SOLAR ENERGY↗

Numerical Simulations in Support of a Long-Term Test of Gas Production From Hydrate Accumulations on the Alaska North Slope: Water Production and Associated Design and Management Issues

Here, we investigated numerical simulation strategies for a long-term test of depressurization-induced gas production from the B1 Sand of Unit B at the Hydrate-01 Stratigraphic Test Well. The main objective of this study was to estimate fluid production rates (with emphasis on water production) under a variety of conditions and production scenarios and contribute new insights to the design and management of the field test. In the first part of the study, we investigated the system response to a three-step depressurization process using two limiting sets of flow properties─the expected maximum and minimum intrinsic and effective permeabilities─for the very heterogeneous reservoir. In the second part, we investigated the effect of the production interval length and placement within the formation relative to the boundaries of the hydrate-bearing unit. The best performing well configuration was used in the third part of the study, which used the most representative subsurface flow properties to investigate the effect of the depressurization strategy on the production performance. The best overall performance (largest gas production with modest water production and a strong response at the observation wells) was obtained with a 10 m-long well situated 3 m below the top of the formation and a three-step depressurization scheme at 15-day intervals to a terminal bottomhole pressure of 2.8 MPa. The overall production performance was enhanced by a faster rate of depressurization. Estimated water production rates in all cases were limited and easily manageable. None of the tested well configurations or depressurization strategies significantly reduced water production without also severely reducing gas production. In all the investigated cases, 95% of the long-term fraction of produced water was replenished by inflows from the boundaries and could not be reduced. These substantial water inflows are an unavoidable feature of HU-B and cannot be easily mitigated by a hydraulic control.

02 PETROLEUM↗

Tre-DST: A Drug Susceptibility Test for Mycobacterium tuberculosis Using Solvatochromic Trehalose Probes

In 2024, an estimated 10 million people developed Tuberculosis (TB), nearly half a million of whom were infected with drug-resistant tuberculosis (DR-TB). Early detection of infection and drug resistance enables rapid engagement in effective care. Bacterial culture and nucleic acid testing remain the primary diagnostic methods, with smear microscopy being phased out. However, these methods present significant limitations for diagnosing drug resistance, such as lengthy time-to-result for phenotypic tests, as well as the need for prior knowledge of resistance mutations and prohibitive cost for molecular tests. To address this, we developed a rapid phenotypic TB drug susceptibility test, termed Tre-DST, based on novel metabolically incorporated trehalose probes, which specifically detect live mycobacteria. We used the nonpathogenic Mycobacterium smegmatis and the virulence-attenuated Mycobacterium tuberculosis (Mtb) H37Ra or auxotrophic Mtb to demonstrate a strong correlation between cost-effective plate reader results and flow cytometry data, suggesting that the plate reader is a suitable fluorescence detector for Tre-DST. We determined that adding a 1-week incubation step allowed Mtb samples originally seeded at 10 4 CFU/mL to become detectable, over 2 weeks earlier than colony-forming unit analysis. We found that Tre-DST reports on drug susceptibility in a drug-agnostic manner, demonstrating loss of fluorescence with frontline TB drugs as well as the newer drug bedaquiline. Tre-DST distinguished RIF- and INH-resistant auxotrophs from susceptible controls and accurately reported the resistance activity. Ultimately, because Tre-DST is agnostic to mechanisms of drug resistance, this assay is likely compatible with all WHO-recommended and future DR-TB drugs as a diagnostic in reference laboratories.

diagnostics↗

Development of an ERT‐Based Framework for Bentonite Buffers Monitoring From Laboratory Tests: 1. Characterizing Thermal–Hydrological–Mechanical Processes

Abstract Bentonite clay is widely used in engineered barrier systems for the permanent disposal of high‐level radioactive waste due to its low permeability, high swelling capacity, and thermal stability. However, the complex thermal‐hydrological‐mechanical (THM) processes induced by heating from decaying radioactive waste and hydration from surrounding rock can lead to heterogeneous changes that are difficult to measure and predict. This study develops an Electrical Resistivity Tomography (ERT)‐based framework for monitoring THM processes, progressing from sample‐scale to bench‐scale tests, to inform field‐scale applications. Sample‐scale tests analyzed small bentonite samples under controlled variations in water content, temperature, and porosity to establish fundamental resistivity relationships. Bench‐scale tests involved larger bentonite columns subjected to heating (up to 200°C) and hydration under controlled pressure, simulating repository conditions. ERT measurements, complemented by X‐ray CT imaging, temperature monitoring, and tracing sensors, revealed coupled THM processes, such as hydration‐induced compression, swelling, and thermal gradients, leading to complex resistivity patterns. The results demonstrate the potential of ERT for capturing THM‐induced resistivity changes, though challenges remain in upscaling and quantitative analysis. This study evaluates laboratory test capabilities and proposes future improvements for understanding THM‐induced resistivity responses. A conceptual framework for ERT implementation in field‐scale monitoring is presented, synthesizing findings from both scales and exploring how ERT data can inform long‐term modeling and reduce prediction uncertainties. Overall, this ERT‐based framework offers a robust method for monitoring bentonite buffers, aiding in early issue detection and supporting the safe long‐term disposal of radioactive waste in geological repositories, while highlighting the need for future development. Plain Language Summary Bentonite clay is crucial in engineered barrier systems (EBS) for containing high‐level radioactive waste due to its ability to absorb water, swell, seal and remain stable under high temperatures. When bentonite absorbs water and heats up from radioactive decay, it experiences complex changes in its physical and mechanical properties. Understanding these changes is important for ensuring the long‐term safety and effectiveness of EBS. This study used Electrical Resistivity Tomography (ERT), a non‐invasive method that measures electrical conductivity to monitor these changes during laboratory experiments. The ERT data revealed significant variations in resistivity corresponding to changes in water content, temperature, and density, providing detailed spatial and temporal insights into the behavior of bentonite. These findings enhance our ability to predict the long‐term performance of bentonite barriers, ensuring the safe containment of radioactive waste. By improving our understanding of bentonite's behavior, this research supports the development of more reliable and effective barrier systems for radioactive waste disposal, protecting the environment and public health. Key Points ERT monitoring was employed to capture resistivity changes in bentonite during controlled heating and hydration experiments, providing insights into THM processes ERT data reveal significant resistivity changes correlated with water content, temperature, and mechanical effects, enhancing the understanding of THM dynamics in bentonite This study explores the potential of the framework for application in field‐scale EBS monitoring, emphasizing the need for integrating additional geophysical methods for comprehensive subsurface imaging

Chen, Hang↗

High-power test of a C-band linear accelerating structure with an RFSoC-based LLRF system

Normal conducting linear particle accelerators consist of multiple rf stations with accelerating structure cavities. Low-level rf (LLRF) systems are employed to set the phase and amplitude of the field in the accelerating structure and to compensate for the pulse-to-pulse fluctuation of the rf field in the accelerating structures with a feedback loop. The LLRF systems are typically implemented with analog rf mixers, heterodyne-based architectures, and discrete data converters. There are multiple rf signals from each of the rf stations, so the number of rf channels required increases rapidly with multiple rf stations. With a large number of rf channels, the footprint, component cost, and system complexity of the LLRF hardware will increase significantly. To meet the design goals of being compact and affordable for future accelerators, we have designed the next-generation LLRF (NG-LLRF) with a higher integration level based on RFSoC technology. The NG-LLRF system samples rf signals directly and performs rf mixing digitally. Further, the NG-LLRF has been characterized in loopback mode to evaluate the performance of the system and has also been tested with a standing-wave accelerating structure, a prototype for the Cool Copper Collider (C 3 ) with a peak rf power level up to 16.45 MW. The loopback test demonstrated amplitude fluctuation below 0.15% and phase fluctuation below 0.15°, which are considerably better than the requirements of C 3 . The rf signals from the different stages of the accelerating structure at different power levels are measured by the NG-LLRF, which will be critical references for the control algorithm designs. The NG-LLRF also offers flexibility in waveform modulation, so we have used rf pulses with various modulation schemes, which could be useful for controlling some of the rf stations in accelerators. In this paper, the high-power test results at different stages of the test setup will be summarized, analyzed, and discussed.

47 OTHER INSTRUMENTATION↗

The shard test and nanoporomechanics reverse classical paradigm of cement hydration being contractive

Le Chatelier in 1887 and Powers in 1947 demonstrated that the volume of nanoscale C-S-H (calcium silicate hydrate) particles formed during hydration is smaller than the combined volume of the reactants—the anhydrous Portland cement and water. Hydration has thus been considered as contractive. An experiment shows that the opposite is true above the nanoscale. The porous skeleton of cement paste expands as the growing C-S-H particles push each other apart, similar to crystal growth pressure. This is significant for high-performance concretes (HPC) with low water-cement ratios (w/c ≤ 0.4), where chemical self-desiccation lowers pore relative humidity by 40%, compared to just 1% in traditional concretes (w/c ≈ 0.5). Standard American Society for Testing and Materials (ASTM) C1608 tests, using 10 mm thick water-immersed specimens, show large shrinkage because the half-time of water ingress is many decades, unable to offset shrinkage-causing self-desiccation. The present experiment, using a laser microscopy-topography technique, proves the opposite—expansion, evidenced by measuring the length changes of water-immersed HPC shards 0.5 mm thick in which the diffusion halftime, only about one hour, allows continuous resaturation of pores, canceling self-desiccation. The faster diffusion (halftime of one hour) enables continuous pore resaturation, preventing shrinkage. When sealed with paraffin oil, the shards self-desiccate and shrink. These findings align with studies since 2015, showing that models excluding hydration expansion cannot fit test data across various specimen sizes and sealing conditions. The results suggest that standardized ASTM tests for the so-called chemical shrinkage in modern concretes with very low water-cement ratios are misleading and need revision.

Science & Technology - Other Topics↗

Characterizing novel Indium Phosphide pad detectors with focused X-ray beams and laboratory tests

Future tracking systems in High Energy Physics experiments will require large instrumented areas with low radiation length. Crystalline silicon sensors have been used in tracking systems for decades, but are difficult to manufacture and costly to produce for large areas. We are exploring alternative sensor materials that are amenable to fast fabrication techniques used for thin film devices. Indium Phosphide pad sensors were fabricated at Argonne National Lab using commercially available InP:Fe 2-inch mono-crystal substrates. Current-voltage and capacitance-voltage characterizations were performed to study the basic operating characteristics of a group of sensors. Micro-focused X-ray beams at Canadian Light Source and Diamond Light Source were used to study the response to ionizing radiation, and characterize the uniformity of the response for several devices. Electrical test results showed a high degree of performance uniformity between the 48 tested devices. X-ray test beam results showed good performance uniformity within tested devices after accounting for spatially-local defects and edge fields. As a result, this motivates further studies into thin film devices for future tracking detectors.

47 OTHER INSTRUMENTATION↗

A flexible test facility for liquid xenon detector development

As liquid xenon time projection chambers scale to ever-larger sizes, so too do the engineering challenges they pose. Here, we describe a large, flexible, multipurpose test facility capable of supporting the development of a number of key aspects of liquid xenon detector systems. Example applications of this facility include characterization of large-area light and charge sensor arrays, tests of xenon purification techniques and materials compatibility, and investigations into high-voltage phenomena. This facility uses an automated and remotely monitored cryo-cooling system based on immersion of the test chamber in a liquid bath rather than conductive coupling, leading to advantages in temperature and pressure stability, as well as increasing required response times in the case of cooling-power loss. Design advantages, operational procedures, and performance of the facility are described, as well as five examples of liquid xenon test chambers that use the facility.

Dark Matter detectors↗