Tracking the Influence of Thermal Expansion and Oxygen Vacancies on the Thermal Stability of Ni-Rich Layered Cathode Materials

The ever-growing demand for high-energy lithium-ion batteries in portable electronics and electric vehicles has triggered intensive research efforts over the past decade. An efficient strategy to boost the energy and power density of lithium-ion batteries is to increase the Ni content in the cathode materials. However, a higher Ni content in the cathode materials gives rise to safety issues. Herein, thermal expansion and oxygen vacancies are proposed as new critical factors that affect the thermal stability of charged Ni-rich cathode materials based on a systematic synchrotron-based X-ray study of Li 0.33 Ni 0.5+x Co 0.2 Mn 0.3-x O 2 (x = 0, 0.1, 0.2) cathode materials during a heating process. Charged cathode materials with higher Ni contents show larger thermal expansion, which accelerates transition metal migration to the Li layers. Oxygen vacancies are formed and accumulate mainly around Ni ions until the layered-to-spinel phase transition begins. The oxygen vacancies also facilitate transition metal migration to the Li layers. Thermal expansion and the presence of oxygen vacancies decrease the energy barrier for cation migration and facilitate the phase transitions in charged cathode materials during the heating process. These results provide valuable guidance for developing new cathode materials with improved safety characteristics.

25 ENERGY STORAGE↗

Energy impact of heating electrification in mid-rise multifamily buildings in mixed-humid climates

Decarbonizing the electric grid in conjunction with electrifying residential heating is a critical step to combat climate change. Heating in multifamily buildings with the existing natural gas-fired central boiler is a complex process that not only leads to overheating in some apartment units but also results in energy waste and high gas bills. In this study, we consider a multifamily building in New York City, USA, to evaluate the performance of five different heating systems, which represent a step-by-step transition from the conventional to a fully electrified heating system, and determine their impact on the site energy consumption and source CO 2 emissions. Results indicate that overheating in a multifamily building can raise the indoor temperature by as much as 8°C above comfortable limits. Transitioning from conventional steam radiators to cold climate heat pumps can reduce annual site heating energy by up to 70% and source CO 2 emissions by up to 21%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Benchmarking Coordination Number Prediction Algorithms on Inorganic Crystal Structures

Coordination numbers and geometries form a theoretical framework for understanding and predicting materials properties. Algorithms to determine coordination numbers automatically are increasingly used for machine learning and automatic structural analysis. In this work, we introduce MaterialsCoord, a benchmark suite containing 56 experimentally-derived crystal structures (spanning elements, binaries, and ternary compounds) and their corresponding coordination environments as described in the research literature. We also describe CrystalNN, a novel algorithm for determining near neighbors. We compare CrystalNN against 7 existing near-neighbor algorithms on the MaterialsCoord benchmark, finding CrystalNN to perform similarly to several well-established algorithms. For each algorithm, we also assess computational demand and sensitivity towards small perturbations that mimic thermal motion. Finally, we investigate the similarity between bonding algorithms when applied to the Materials Project database. Finally, we expect that this work will aid the development of coordination prediction algorithms as well as improve structural descriptors for machine learning and other applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Interface and Thermophysical Properties of R 32 Refrigerant

Driven by the urgent demand for efficient cooling in microelectronics and advanced thermal management systems, difluoromethane (R32/CH 2 F 2 ) has emerged as a promising candidate owing to its favorable thermophysical properties, including high heat transfer efficiency and low viscosity. While bulk properties such as density, viscosity, and thermal conductivity have been widely studied, interfacial properties, including surface tension and interfacial thickness, remain comparatively underexplored, despite their importance in phase-transition dynamics. Here, we perform molecular dynamics (MD) simulations from 180 to 300 K using an optimized transferable force field for fluoropropenes with enhanced electrostatics to assess both bulk and interfacial behavior of R32. Simulations reproduced density within ±2.1%, viscosity within 3.05%, and thermal conductivity within 7.41% of NIST reference data. Heat capacities (C p and C v ) were predicted within 5%. For interfacial properties, surface tension trends were reproduced within 13.58% deviation, and the vapor–liquid coexistence curve closely matched reference data, yielding a critical temperature of 345.7 K (1.6% deviation) and a critical density of 0.397 g/cm 3 (6.4% deviation). Importantly, the vapor–liquid interface exhibited pronounced temperature-dependent broadening across the 180–290 K range. This behavior correlates with increasing molecular kinetic energy, reduction in intermolecular cohesive interactions, and a progressive loss of preferential dipole alignment, which collectively enhance thermal fluctuation amplitudes at elevated temperatures. These validated results provide predictive molecular-level insights, particularly for interfacial properties that remain less characterized. By reducing property prediction errors in key parameters such as critical temperature, this work provides reliable inputs for heat-exchanger and system models. Such correlations can support optimized component sizing, improved performance, and reduced refrigerant charge. Beyond R32, the methodology offers a transferable framework for blended and next-generation low-GWP refrigerants, contributing to sustainable thermal management aligned with the 2027 EU F-Gas regulation and 2030 Kigali Amendment.

Fluids↗

Technoeconomic feasibility of photovoltaic recycling

Abstract Photovoltaic (PV) modules are a key technology to aid the imminent transition from carbon‐based energy. End‐of‐life crystalline silicon PV modules produce a waste stream that is predominantly landfilled due to the recycling challenges associated with PV reuse economics. Current practices recycle the aluminum frame and repurpose the junction box but landfill the rest of the module. The primary challenge in recycling the remaining module is finding a technoeconomically viable method for separating the silicon and glass from the ethylene vinyl acetate (EVA) layers. This issue will rapidly expand with time as it is estimated that flat glass production for solar panels is currently unable to meet the demand for PV. Current literature suggests that chemical, thermal, and mechanical delamination offer economically feasible solutions under ideal circumstances. In this work we evaluate these methods using end‐of‐life panels and assess the economic viability. The technoeconomic study presented here suggests the most economically viable option for disposing of end‐of‐life solar panels, given current technology, is landfilling. Thermal delamination may offer an alternative route in the future. Financial incentives, which can be quantified with this work, may be required to kickstart PV recycling to help bridge externalities around environmental impact.

Crespo, Beatrice↗

Advanced Energy Approaches for Mixed-Use Developments in the Front Range Urban Corridor

The primary objective of the document is to present example technical approaches and strategies that planners and developers can reference for all-electric mixed-use developments in the Rocky Mountain Front Range urban corridor that are considering advanced energy performance goals such as high levels of energy efficiency and renewable integration. The strategies are tailored toward the vision for a zero energy, all-electric, district thermal system-connected starter district. In this example, on-site solar generation is emphasized as a strategy that can be combined with electrical and thermal energy storage for enhanced community resilience and demand flexibility. Opportunities for utilizing or adapting these strategies include: sharing with vertical developers for potential integration of strategies into vertical design guidelines; incorporation into Owner Project Requirements (OPRs); providing example strategies to design teams as a starting point for design; informing structure of agenda for a building design charrette; comparing building designs to example strategies at various points in the design process to evaluate design progression. While the technical strategies outlined in this document can help inform the development of guidelines for projects in the Front Range urban corridor, this document does not set requirements for any rating, certification, program, or policy.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Dynamic Probabilistic Safety Assessment Studies for Advanced Reactor Using RAVEN

Probabilistic Safety Assessment (PSA) is used extensively to evaluate the risks associated with complex engineering systems like Nuclear Power Plants (NPPs). Current PSA models are based on the Event-Tree/Fault-Tree (ET/FT) methodology. ET and FT models are static and are based on Boolean logic approaches. In the past, concerns have been raised in the literature regarding the capability of the traditional static modelling approaches to adequately account for the impact of process, hardware, software, firmware and human interactions on the stochastic system behaviour. To overcome the limitations of the traditional approach to PSA, several dynamic PSA methodologies have been proposed. One of the dynamic PSA methodologies used for dynamic evaluations is Dynamic Event Tree (DET) framework which can be used to assess the impact of the parameter variability and scenario dynamics on the PSA model for the initiating event. The DET framework couples the stochastic model (number of component/trains that start on demand, operator action timing, etc.) with a Thermal-Hydraulic (TH) model of the plant. This paper explores the use of DET along with a case study on advanced reactor. The initiating event selected for the study was Class IV power supply failure event. The TH analysis considering uncertainty in various parameters was performed using RELAP5 and Reactor Analysis and Virtual control ENvironment (RAVEN) tool. Based on the uncertainty analysis, it is concluded that the peak clad temperatures (PCT) are within the limits in all the code runs implying a high-degree of safety margin. However, variation in time to reach the PCT was observed among the code runs and the mean time to reach the PCT was found to be around 8590sec (approximately 2.4 hours). Hence, sufficient time margin is available for human intervention and the operator might have a relatively stress-free state during such an accident scenario. Due to the static nature of the traditional PSA models, the safety margin available was lesser, whereas, with the help of dynamic PSA models, one can demonstrate that the actual available safety margin is more in the present case study and is valuable input from the design point of view.

99 GENERAL AND MISCELLANEOUS↗

Dispatch Informed Hydrogen Production

The cost of hydrogen production is projected to decline over the next several decades alongside the widespread deployment of energy constrained generating resources and electrification. While today’s system can utilize fast responding thermal generating assets to answer to changes in demand and energy constrained resource output, the system of tomorrow will more likely rely upon price responsive demands and virtual power plants. Since hydrogen is anticipated to be a primary generating fuel of the future while also providing a large demand base for its production, it is reasonable to evaluate the potential performance for hydrogen-electric coordination issues.

Brewer, John↗

Thermal modeling of directed energy deposition additive manufacturing using graph theory

Purpose: The purpose of this paper is to develop, apply and validate a mesh-free graph theory–based approach for rapid thermal modeling of the directed energy deposition (DED) additive manufacturing (AM) process. Design/methodology/approach: Here, the authors develop a novel mesh-free graph theory–based approach to predict the thermal history of the DED process. Subsequently, the authors validated the graph theory predicted temperature trends using experimental temperature data for DED of titanium alloy parts (Ti-6Al-4V). Temperature trends were tracked by embedding thermocouples in the substrate. The DED process was simulated using the graph theory approach, and the thermal history predictions were validated based on the data from the thermocouples. Findings: The temperature trends predicted by the graph theory approach have mean absolute percentage error of approximately 11% and root mean square error of 23°C when compared to the experimental data. Moreover, the graph theory simulation was obtained within 4 min using desktop computing resources, which is less than the build time of 25 min. By comparison, a finite element–based model required 136 min to converge to similar level of error. Research limitations/implications: This study uses data from fixed thermocouples when printing thin-wall DED parts. In the future, the authors will incorporate infrared thermal camera data from large parts. Practical implications: The DED process is particularly valuable for near-net shape manufacturing, repair and remanufacturing applications. However, DED parts are often afflicted with flaws, such as cracking and distortion. In DED, flaw formation is largely governed by the intensity and spatial distribution of heat in the part during the process, often referred to as the thermal history. Accordingly, fast and accurate thermal models to predict the thermal history are necessary to understand and preclude flaw formation. Originality/value: This paper presents a new mesh-free computational thermal modeling approach based on graph theory (network science) and applies it to DED. The approach eschews the tedious and computationally demanding meshing aspect of finite element modeling and allows rapid simulation of the thermal history in additive manufacturing. Although the graph theory has been applied to thermal modeling of laser powder bed fusion (LPBF), there are distinct phenomenological differences between DED and LPBF that necessitate substantial modifications to the graph theory approach.

42 ENGINEERING↗

Nuclear—thermal energy storage configurations for industrial combined heat and power supply—conceptual and thermodynamic study with high temperature gas-cooled reactor

Nuclear systems are promising candidates for delivering resilient heat and power for future energy security and independence. Traditionally, nuclear plants have been used for baseload electricity production and cogeneration of heat has seen relatively limited application utilizing typically only small portion of a reactor's thermal output. This paradigm may shift due to the increasing penetration of intermittent renewables and need for resource flexibility, various decarbonization efforts aimed at both electricity and heat demands, along with the perspective of small modular nuclear reactor applications, which can be sized based on local industrial needs. Here, this study provides a comprehensive guide for the nuclear and industrial sectors, emphasizing controllability in the combined heat and power configuration options for high temperature gas-cooled reactor and process steam supply. It investigates the integration of thermal energy storage to improve nuclear energy's responsiveness to varying industrial demands. The study emphasizes placing thermal energy storage between the nuclear primary loop and steam cycle to achieve greater efficiency and flexibility in power and heat output, surpassing traditional combined heat and power systems and avoiding efficiency losses seen in other thermal energy storage integration approaches.

combined heat and power (CHP)↗

Microwave-Assisted Activation of Mo/HZSM5 in Methane Dehydroaromatization

Natural gas flaring is a significant challenge for oil and gas producers. One viable option to mitigate flaring is the conversion of natural gas into valuable chemicals. Applying microwave energy to heterogenous catalyst materials offers advantages in terms of higher rates and product selectivities in comparison to traditional thermal systems which can be designed for on-demand chemical production in modular reactor systems. Methane dehydroaromatization (MDHA) produces transportable, liquid aromatic products directly from natural gas, which is ideal for remote production but is hindered by low thermodynamic yields and rapid deactivation. The stability and performance of the Mo/ZSM5 catalyst is often determined by the state and nature of Mo in the catalyst, which in turn is dictated by the temperature and gaseous environment during catalyst activation. In this study, the Mo/HZSM5 catalyst was activated under three different heating modes (thermal, microwave E-field, and microwave H-field) and four different gas environments (CO, He, CH4+H2, and H2). All the activated catalysts were characterized using different tools and performance evaluated in MDHA.

methane dehydroaromatization↗

Transient Modelling of HTGR Thermal Load Follow in Modelica

The ability of nuclear power plants to load follow electrical power demand is particularly important as we move to higher variable renewable (VRE) energy production on low carbon energy grids. High temperature gas reactors (HTGRs) are capable of load following by adjusting thermal output, but their high temperatures and thermal inertia significantly impact the power transients they are able to follow. To aid investigation into new integrated energy systems with advanced reactors, it is necessary to have an open-source transient model of a full HTGR primary and secondary. This paper introduces two new open-source models for a HTGR and corresponding balance of plant (BOP) written for the HYBRID library developed at Idaho National Laboratory. A transient thermal load follow test case was taken by the work from Brits et al. to benchmark our open-source model against transient operation results from other proprietary codes that exist. The control scheme for the two new models in combination is discussed and a comparison of the response in transient load follow between the two codes performed.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Molten Chloride Thermophysical Properties, Chemical Optimization, and Purification

Next-generation concentrating solar power (CSP) technology requires high-temperature heat-transfer fluids and thermal energy storage that can operate in the temperature range of 500°–720°C. This high temperature demands a new chemistry for the heat-transfer fluids that must have high-temperature thermal and chemical stabilities, high energy density, and low corrosion rate on metallic materials used in the heat exchangers, piping, and thermal energy storage tanks. A ternary MgCl 2 -KCl-NaCl chloride-salt system has been proposed to achieve such goals, given its high-temperature thermal stability. The chloride-salt-based systems have been used by the metallurgy industry as the electrolyte to electrolytically extract metallic magnesium. They have also attracted attentions from the nuclear industry for developing the molten salt fast reactors that can operate at close to atmospheric pressure and at higher temperature than traditional light-water reactors. However, the corrosion properties of the ternary salt are not well known. The corrosion mechanism is believed to be correlated to the presence of MgOHCl impurity at the operation temperature. MgOHCl is fundamentally caused by the hygroscopic nature of the MgCl 2 component. Therefore, the first key objective of this project is to understand the nature of the corrosiveness of the ternary chloride-salt system and its prevention by designing new lab-scale purification processes. Because of its importance, a working group called the Chloride Salt Collective across multiple U.S. Department of Energy national laboratories is established to gain experimental agreement on the corrosion behaviors. In addition, water generation during salt dehydration could lead to highly corrosive HCl/water mixture via a hydrolysis process between water and anhydrous MgCl 2 or MgCl 2 hydrates. MgOHCl will eventually be converted to MgO particulates regardless of the chemical path chosen (i.e., by thermal decomposition, chemical purification with an active metal, or electrochemical purification utilizing the reduction power of electron flows). Large MgO particles with high hardness can wear out bearing and bushing and even clog the delicate channels in the primary heat exchanger. Because of this, a second objective is to understand the chemistry behind salt purification and transfer the scientific understanding to a set of engineering know-how for large-scale salt melter design. Because there is limited information on the thermophysical properties and the sensitivity of these properties around the targeted salt composition, a third objective is to measure thermophysical properties relevant to system and component design and support Topic 1 Liquid Pathway development. For example, composition shift due to salt reaction with water can be a potential issue because it can lead to changes of thermophysical properties, such as (1) melting point (or freeze point), which can jeopardize safe operation of the supercritical CO 2 power cycle proposed for next-generation CSP, and (2) heat capacity and density, which can decrease the overall power-generation capability of the plants. The value of the thermal conductivity of the selected salt composition is also a critical criterion for the solar receiver design.

14 SOLAR ENERGY↗

Deep reinforcement learning control for co-optimizing energy consumption, thermal comfort, and indoor air quality in an office building

With the recent demand for decarbonization and energy efficiency, advanced HVAC control using Deep Reinforcement Learning (DRL) becomes a promising solution. Due to its flexible structures, DRL has been successful in energy reduction for many HVAC systems. However, only a few researches applied DRL agents to manage the entire central HVAC system and control multiple components in both the water loop and the air loop, owing to its complex system structures. Moreover, those researches have not extended their applications by incorporating the indoor air quality, especially both CO2 and PM2.5concentrations, on top of energy saving and thermal comfort, as achieving those objectives simultaneously can cause multiple control conflicts. What's more, DRL agents are usually trained on the simulation environment before deployment, so another challenge is to develop an accurate but relatively simple simulator. Therefore, we propose a DRL algorithm for a central HVAC system to co-optimize energy consumption, thermal comfort, indoor CO2 level, and indoor PM2.5 level in an office building. To train the controller, we also developed a hybrid simulator that decoupled the complex system into multiple simulation models, which are calibrated separately using laboratory test data. The hybrid simulator combined the dynamics of the HVAC system, the building envelope, as well as moisture, CO2, and particulate matter transfer. Three control algorithms (rule-based, MPC, and DRL) are developed, and their performances are evaluated on the hybrid simulator environment with a realistic scenario (i.e., with stochastic noises). The test results showed that, the DRL controller can save 21.4 % of energy compared to a rule-based controller, and has improved thermal comfort, reduced indoor CO2 concentration. The MPC controller showed an 18.6 % energy saving compared to the DRL controller, mainly due to savings from comfort and indoor air quality boundary violations caused by unmeasured disturbances, and it also highlights computational challenges in real-time control due to non-linear optimization. Finally, we provide the practical considerations for designing and implementing the DRL and MPC controllers based on their respective pros and cons.

Guo, Fangzhou↗

End-Use Savings Shapes Measure Documentation: Thermostat Control for Load Shedding in Large Offices

This documentation focuses on a single End-Use Savings Shape measure - thermostat control for load shedding. The thermostat control for load shedding measure applies heating and cooling temperature setpoint offsets for reducing the heating and cooling load during peak window. The measure takes daily peak load schedule inputs generated by the method "Dispatch Schedule Generation" described in the "Supplemental Documentation: Dispatch Schedule Generation for Demand Flexibility Measures" to determine the start and end times of the peak window, and then adjusts the thermostat cooling and/or heating setpoints by an offset value from original schedules during the peak window to reduce the HVAC or whole building daily peak load. The measure is flexible and allows users to adjust the heating and cooling offset values respectively, but for this study, the adjustment for heating and cooling setpoints are set to -2 degrees Celsius and +2 degrees Celsius by default. The measure provides options of adding rebound control period (default 2 hours) after peak windows for the setpoints to be ramped back to default values, to prevent the system from generating higher peak demand with step changes of setpoints in post-peak periods . This measure is applicable t o large offices equipped with electric HVAC system (either electric cooling only or both electric heating and cooling), which account for approximately 8.72% of the ComStock floor area. The thermostat control for load shedding measure demonstrates 2-5% daily peak demand reduction and 0.068% total site energy savings (3 trillion British thermal units [TBtu]) for the U.S. commercial building stock modeled in ComStock.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End-Use Savings Shapes Measure Documentation: Thermostat Control for Load Shifting in Large Offices

This documentation focuses on a single end-use savings shape measure - thermostat control for load shifting. The thermostat control for load shifting measure applies heating and cooling temperature setpoint adjustment for pre-conditioning before the peak window. The measure takes daily peak load schedule inputs generated by the method "Dispatch Schedule Generation" described in the "Supplemental Documentation: Dispatch Schedule Generation for Demand Flexibility Measures" to determine the start time of the peak window, and then adjusts the thermostat cooling or heating setpoints by a specified offset value from original schedules to precool or preheat the space , for a specified length of time before the start of peak window, and thus shifts load in the peak window to the pre-conditioning period. The measure is flexible and allows users to adjust the heating and cooling offset values and length of pre-conditioning period, but for this study, the load shifting strategy is applied as pre-cooling only (adjusting only cooling setpoints). The default adjustment for cooling setpoints is set to -1 degrees Celsius , and the default duration of pre-cooling is 1 hour. This measure is applicable to large offices equipped with electric HVAC system, which account for approximately 8.72% of the ComStock floor area. The thermostat control for load shifting measure demonstrates -1% daily peak demand reduction and 0% total site energy savings (0 trillion British thermal units [TBtu]) for the U.S. commercial building stock modeled in ComStock.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

In Cell Thermal Creep Frames for Demonstration Project Preparations

The thrust of advanced nuclear reactor demonstrations demands the accelerated qualification of in-core materials to enable licensing processes and developing the performance data. Due to the high-operating temperatures of such reactors, long-term mechanical behavior under constant load is essential to determine the geometrical and mechanical integrity of in-core components during operation and off-normal conditions. Therefore, the thermal creep behavior of neutron-irradiated advanced reactor materials must be determined. The feasibility of using subsize specimens for the irradiation campaigns and the limited available infrastructure challenge the assessment of thermal creep behavior of advanced reactor materials. Therefore, the U.S. Department of Energy Office of Nuclear Energy (DOE-NE) National Reactor Innovation Center (NRIC) prioritizes the development of a thermal creep testing infrastructure for multiple subsize specimens to accelerate the demonstration and deployment of advanced reactor concepts. This report describes the activities for the construction of a thermal creep testing capability at Idaho National Laboratory (INL). The overall project consists of conceptual design, out-of-cell demonstration, and in-cell demonstration phases. During fiscal year (FY)-2021, the team finished the conceptual design of a thermal creep test facility that can test multiple subsize specimens. This conceptual design consisted of the determination of technical and functional requirements, the determination of the design space, and the preparation of the technical drawings. Technical and functional requirements were categorized as required and desired capabilities and the conceptual design was performed to meet all the required capabilities with the flexibility to achieve the desired capabilities. The design space identified the operational capacity of the creep frame for different advanced reactor relevant materials with the consideration of the feasible operation in the hotcell at the Fuels and Applied Science Building (FASB) at INL. Based on the requirements and design space, the multiple specimen creep frame was designed. The official INL engineering drawing process was started and the procurement of materials for construction was initiated. For FY-2022, the out-of-cell demonstration and final installation of the multiple creep frame is planned.

36 MATERIALS SCIENCE↗

Influence of Phase-Change Materials and Operating Periods on Load Shifting for Thermal Storage Heat Pumps in European Climate Zones

As the reliance on heat pumps (HPs) for space conditioning increases worldwide, ex-tensive grid strains during utility peak hours are expected. Significant research efforts focus on investigating the use of integrated thermal energy storage (TES) systems to reduce peak energy demands. Conventionally, TES systems are often integrated to store and provide either cooling or heating, but not both. In this work, a single room-temperature phase-change material (PCM)-TES was integrated for dual-mode opera-tion with an R290 air-to-water 10.5 kW (3-Ton) HP. Two PCM melting temperatures (17°C, 22°C) were assessed to investigate their impact on system performance and cost reductions for Milan, Italy (4A); Barcelona, Spain (3A); and Oslo, Norway (6A). HP and HP-TES performance maps were generated using Modelica-based transient models and co-simulated with a prototype residential building using the Spawn of En-ergyPlusTM with simple rule-based controls. Our simulations indicate that PCM-17°C provided annual cost savings at higher peak-to-off-peak cost ratios, as the demand re-duction dominated the savings potential. The recharge energy costs and requirements became more dominant at lower cost ratios, making PCM-22°C more beneficial at lower cost ratios. Finally, despite Oslo's heating-dominated climate, the utility peak hours favor cooling demand reductions, making PCM-17°C more appealing. In all cases, the cost savings potential stabilized between 4 – 10% regardless of cost ratio, suggesting that system-level component and operation control optimization is required to maximize cost savings further.

25 ENERGY STORAGE↗