Search NASA⌕ Search

SEARCH · Search NASA

Results for “throughput”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Accelerating catalytic advancements through the precision of high-throughput experiments & calculations

The growing demand for energy-efficient processes to support a sustainable future drives the need for research to rapidly explore chemical and material space through accelerated catalyst discovery initiatives. Recent breakthroughs in high-throughput experimental and computational methods are transforming the catalysis field, surpassing traditional approaches to manipulating variables in catalytic processes. Key advancements in innovation include the integration of machine learning for efficient catalyst screening, high-throughput experimentation, data-driven methodologies employing comprehensive databases, and in situ and in operando techniques for realistic observations. This progress has undoubtedly been intertwined with a collaborative framework across disciplines, reshaping catalyst discovery methods in both industry and academia. This Opinion article presents a multifaceted perspective from coauthors with expertise spanning various stages of the Technology Readiness Level spectrum, highlighting both opportunities and persistent challenges in integrating computational and experimental approaches in catalysis. These challenges span from obtaining high-quality experimental data, scaling simulations to industrially relevant materials and process conditions to navigating the complexity and predictive accuracy of computational models.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Challenging conventional assumptions in PV: a high-throughput open-air approach to low-cost perovskite module production

Perovskite solar modules (PSMs) offer a promising pathway to low-cost photovoltaics, yet their commercialization is challenged by manufacturing scalability, device uniformity, additive costs, interlayer complexity, and module stability. This study introduces a comprehensive technoeconomic analysis of single junction PSM's and projections for tandem perovskite-Si modules that integrate all materials and manufacturing steps, module performances, projected lifetimes, and manufacturing costs across scales. Here, we highlight an open-air manufacturing approach to fabricate all active layers of serially interconnected PSMs, including electrodes and charge transport layers, enabling high-throughput production without inert or vacuum environments. The analysis reveals two orders of magnitude throughput enhancement and cost reductions of 24% in all-open-air production, escalating to over 60% at 1 GW factory capacity compared to conventional methods. Levelized cost of energy (LCOE) projections for utility-scale installations over 30 years, accounting for module replacement and recycling, demonstrate the potential to achieve the 2030 US target of $0.03 per kWh with realistic 7–11-year PSM lifetimes, outperforming incumbent silicon-based modules. Neither four terminal (4T) nor two terminal (2T) tandem-Si PSMs improve over single junction perovskite or silicon LCOE regardless of higher efficiencies at any modeled lifetime. Addressing PSM technical challenges with a cost-modeling framework guides commercialization efforts and provides a convincing pathway for challenging incumbent Si-based PV.

14 SOLAR ENERGY↗

A high-throughput reaction system to measure the gas-phase photocatalytic oxidation activity of TiO{sub 2} nanotubes

A sixteen-channel, high-throughput system was designed and built to test the activity of catalysts for gas-phase photocatalytic oxidation of methanol. The system utilizes granular catalyst films to model relevant applications and allow for rapid processing. It is capable of 48 catalyst tests per day using the procedure described herein. Several experiments were performed to minimize both the within-node and between-node variances of the system. Utilizing the high-throughput system, the significance of preparation methods on the photocatalytic activity of TiO{sub 2} nanotubes was investigated. A one-half fractional factorial experiment identified the factors that significantly impact catalyst activity as the following: precursor type (Degussa P-25, or nanotubes), platinum loading, the interaction between precursor and dope time, and the interaction between the precursor and calcination temperature. Based on experimental results, catalyst activity is optimized by doping TiO{sub 2} nanotubes directly (rather than doping P-25 prior to nanotube formation), a low platinum loading (0.01 wt %), and using a dope time of 30 min followed by calcination at 773 K. The optimum catalyst preparation conditions produced a catalyst that was three times more active than the starting P-25 material.

36 MATERIALS SCIENCE↗

High energy x-ray diffraction/x-ray fluorescence spectroscopy for high-throughput analysis of composition spread thin films

High-throughput crystallography is an important tool in materials research, particularly for the rapid assessment of structure-property relationships. We present a technique for simultaneous acquisition of diffraction images and fluorescence spectra on a continuous composition spread thin film using a 60 keV x-ray source. Subsequent noninteractive data processing provides maps of the diffraction profiles, thin film fiber texture, and composition. Even for highly textured films, our diffraction technique provides detection of diffraction from each family of Bragg reflections, which affords direct comparison of the measured profiles with powder patterns of known phases. These techniques are important for high throughput combinatorial studies as they provide structure and composition maps which may be correlated with performance trends within an inorganic library.

36 MATERIALS SCIENCE↗

High-throughput characterization of stresses in thin film materials libraries using Si cantilever array wafers and digital holographic microscopy

We report the development of an advanced high-throughput stress characterization method for thin film materials libraries sputter-deposited on micro-machined cantilever arrays consisting of around 1500 cantilevers on 4-inch silicon-on-insulator wafers. A low-cost custom-designed digital holographic microscope (DHM) is employed to simultaneously monitor the thin film thickness, the surface topography and the curvature of each of the cantilevers before and after deposition. The variation in stress state across the thin film materials library is then calculated by Stoney's equation based on the obtained radii of curvature of the cantilevers and film thicknesses. DHM with nanometer-scale out-of-plane resolution allows stress measurements in a wide range, at least from several MPa to several GPa. By using an automatic x-y translation stage, the local stresses within a 4-inch materials library are mapped with high accuracy within 10 min. The speed of measurement is greatly improved compared with the prior laser scanning approach that needs more than an hour of measuring time. A high-throughput stress measurement of an as-deposited Fe-Pd-W materials library was evaluated for demonstration. The fast characterization method is expected to accelerate the development of (functional) thin films, e.g., (magnetic) shape memory materials, whose functionality is greatly stress dependent.

36 MATERIALS SCIENCE↗

Optima MDxt: A high throughput 335 keV mid-dose implanter

The continuing demand for both energy purity and implant angle control along with high wafer throughput drove the development of the Axcelis Optima MDxt mid-dose ion implanter. The system utilizes electrostatic scanning, an electrostatic parallelizing lens and an electrostatic energy filter to produce energetically pure beams with high angular integrity. Based on field proven components, the Optima MDxt beamline architecture offers the high beam currents possible with singly charged species including arsenic at energies up to 335 keV as well as large currents from multiply charged species at energies extending over 1 MeV. Conversely, the excellent energy filtering capability allows high currents at low beam energies, since it is safe to utilize large deceleration ratios. This beamline is coupled with the >500 WPH capable endstation technology used on the Axcelis Optima XEx high energy ion implanter. The endstation includes in-situ angle measurements of the beam in order to maintain excellent beam-to-wafer implant angle control in both the horizontal and vertical directions. The Optima platform control system provides new generation dose control system that assures excellent dosimetry and charge control. This paper will describe the features and technologies that allow the Optima MDxt to provide superior process performance at the highest wafer throughput, and will provide examples of the process performance achievable.

43 PARTICLE ACCELERATORS↗

Solion ion source for high-efficiency, high-throughput solar cell manufacturing

In this paper, we introduce the Solion ion source for high-throughput solar cell doping. As the source power is increased to enable higher throughput, negative effects degrade the lifetime of the plasma chamber and the extraction electrodes. In order to improve efficiency, we have explored a wide range of electron energies and determined the conditions which best suit production. To extend the lifetime of the source we have developed an in situ cleaning method using only existing hardware. With these combinations, source life-times of >200 h for phosphorous and >100 h for boron ion beams have been achieved while maintaining 1100 cell-per-hour production.

14 SOLAR ENERGY↗

High-throughput and automated SAXS/USAXS experiment for industrial use at BL19B2 in SPring-8

A highly automated system combining a sample transfer robot with focused SR beam has been established for small-angle and ultra small-angle X-ray scattering (SAXS/USAXS) measurement at BL19B2 for industrial use of SPring-8. High-throughput data collection system can be realized by means of X-ray beam of high photon flux density concentrated by a cylindrical mirror, and a two-dimensional pixel detector PILATUS-2M. For SAXS measurement, we can obtain high-quality data within 1 minute for one exposure using this system. The sample transfer robot has a capacity of 90 samples with a large variety of shapes. The fusion of high-throughput and robotic system has enhanced the usability of SAXS/USAXS capability for industrial application.

43 PARTICLE ACCELERATORS↗

A pulse-front-tilt–compensated streaked optical spectrometer with high throughput and picosecond time resolution

A high-throughput, broadband optical spectrometer coupled to the Rochester optical streak system equipped with a Photonis P820 streak tube was designed to record time-resolved spectra with 1-ps time resolution. Spectral resolution of 0.8 nm is achieved over a wavelength coverage range of 480 to 580 nm, using a 300-groove/mm diffraction grating in conjunction with a pair of 225-mm-focal-length doublets operating at an f/2.9 aperture. Overall pulse-front tilt across the beam diameter generated by the diffraction grating is reduced by preferentially delaying discrete segments of the collimated input beam using a 34-element reflective echelon optic. The introduced delay temporally aligns the beam segments and the net pulse-front tilt is limited to the accumulation across an individual sub-element. The resulting spectrometer design balances resolving power and pulse-front tilt while maintaining high throughput.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Message-passing neural networks for high-throughput polymer screening

Machine learning methods have shown promise in predicting molecular properties, and given sufficient training data, machine learning approaches can enable rapid high-throughput virtual screening of large libraries of compounds. Graph-based neural network architectures have emerged in recent years as the most successful approach for predictions based on molecular structure and have consistently achieved the best performance on benchmark quantum chemical datasets. However, these models have typically required optimized 3D structural information for the molecule to achieve the highest accuracy. These 3D geometries are costly to compute for high levels of theory, limiting the applicability and practicality of machine learning methods in high-throughput screening applications. In this study, we present a new database of candidate molecules for organic photovoltaic applications, comprising approximately 91,000 unique chemical structures. Compared to existing datasets, this dataset contains substantially larger molecules (up to 200 atoms) as well as extrapolated properties for long polymer chains. We show that message-passing neural networks trained with and without 3D structural information for these molecules achieve similar accuracy, comparable to state-of-the-art methods on existing benchmark datasets. Furthermore, these results therefore emphasize that for larger molecules with practical applications, near-optimal prediction results can be obtained without using optimized 3D geometry as an input. We further show that learned molecular representations can be leveraged to reduce the training data required to transfer predictions to a new density functional theory functional.

14 SOLAR ENERGY↗

VIPIR: A High-Throughput Drop-Weight Impact Instrument for Imaging the Initiation and Propagation of Reactions in Energetic Materials

Characterizing the handling safety and sensitivity of explosives has been a challenging area of study for over 60 years. Historically one of the most accessible and widely utilized experiments has been the drop-weight impact test, which involves dropping a weight on a small sample sandwiched between two anvils. Because this experiment generally only utilizes sound thresholds to determine whether or not a sample reacted, the physical and chemical properties governing sensitivity remain convolved. Better understanding of chemical and material characteristics is needed to give the chemistry and engineering communities a predictive tool to determine the handling sensitivity of explosives prior to pursuing expensive and potentially hazardous synthesis and formulation operations. Here, we are developing a high throughput drop tower instrument capable of imaging the deformation and flow of energetic materials during impact and the resulting thermal ignition and propagation events. This instrument is based on previous designs but has been modified for higher throughput and tailorable modifications in the future. Herein, we present key design features that enable high-speed visible and thermal imaging of explosive initiation by sub-shock impacts, as well as preliminary results in which ignition sites were observed in an erythritol tetranitrate sample.

47 OTHER INSTRUMENTATION↗

Absolute throughput calibration of multiple spherical crystals for the Orion High-REsolution X-ray spectrometer (OHREX)

We present absolute throughput analysis of several crystals for the Orion High-REsolution X-ray (OHREX) imaging crystal spectrometer using ray tracing and experimental measurements. The OHREX spectrometer is a high-resolution x-ray spectrometer designed to measure spectral line shapes at the Orion laser facility. The spectrometer is fielded with up to two spherical crystals simultaneously covering two independent spectral ranges. Each crystal has a nominal radius of curvature of R = 67.2 cm and is fielded at a nominal Bragg angle of 51.3°. To cover different bands of interest, several different crystals are available, including Ge (111), KAP, and several cuts of quartz, whose resolving power λ/Δλ exceeds 10 000. The calibrated response of the available crystals has previously been reported from measurements at the EBIT-I electron beam ion trap at Lawrence Livermore National Laboratory. Here, we model the absolute throughput of each crystal using ray tracing and verify the results using experimental data for the quartz $(10\bar{1}1)$ crystal.

47 OTHER INSTRUMENTATION↗

High-throughput, in situ imaging of multi-layer powder-blown directed energy deposition with angled nozzle

Laser metal additive manufacturing (AM) has become an increasingly popular technology due to its flexibility in geometry and materials. As one of the commercialized additive processes, powder-blown directed energy deposition (DED) has been used in multiple industries such as aerospace, automotive, medical device, etc. However, a lack of fundamental understanding remains for this process, and many opportunities for alloy development and implementation can be identified. A high-throughput, in situ DED system capable of multi-layer builds that can address these issues is presented here. In this work, implications of layer heights and energy density are investigated through an extensive process parameter sweep, showcasing the power of a high-throughput setup while also discussing multi-layer interactions.

47 OTHER INSTRUMENTATION↗

High throughput, spatially resolved thermal properties measurement using attachable and reusable 3ω sensors

The 3ω method is a well-established thermal technique used to measure the thermal conductivity of materials and the thermal resistance of interfaces. It has significant advantages over other steady state and transient thermal techniques in its ability to provide spatially resolved thermal property measurements over a wide range of thermal conductivity. Despite its advantages, it has been restricted to lab-scale use because of the difficulty involved in sample preparation and sensor fabrication and is limited to non-metallic substrates. High-throughput 3ω measurements with reusable sensors have not been realized yet. In this work, we demonstrate a method of applying reusable 3ω sensors fabricated on flexible polyimide films to measure bulk and spatially resolved thermal properties. Here, we establish the limits of thermal conductivity measurement with the method to be 1 to 200 W/mK, and within the measurement limit, we verify the method by comparing the measured thermal conductivities of standard samples with established values. From the 3ω measurements, we also determine the thermal resistance of an interlayer of thermal grease as a function of pressure and compare it against the resistance calculated from direct thickness measurements to demonstrate the ability of this method to provide spatially resolved subsurface information. The technique presented is general and applicable to both metallic and non-metallic substrates, providing a method for high-throughput 3ω measurements with reusable sensors and without considerable sample preparation.

47 OTHER INSTRUMENTATION↗

High-throughput approach for investigating interdiffusion in medium- and high-entropy alloys

Interdiffusion experiments are usually time-consuming and tedious since diffusion couples must be annealed at several temperatures for a long time. The efforts required to study interdiffusion in multicomponent alloys increase dramatically as multiple diffusion couples are required to cover broad composition ranges and determine the diffusivities of individual elements in different chemical environments. To circumvent this challenge, we present a high-throughput approach applicable to single-phase and compositionally complex alloys, which are assumed to approximate ideal solid solutions. Here, a simple diffusion-multiple experiment combined with a physically based kinetic model is proposed to efficiently determine the diffusion coefficients of the constituent elements in quaternary CrFeCoNi alloys. Compared with tracer diffusivities reported in the literature, the results, thus, obtained do not differ by more than a factor of 2 and were obtained from a single interdiffusion experiment. In contrast, the diffusivities simulated with commercial mobility and thermodynamic databases are strongly overestimated by a factor ranging from 1 to 16. Therefore, our approach enables high-throughput determination of diffusivities and can help in the design of alloys for high-temperature applications where diffusion plays a key role.

36 MATERIALS SCIENCE↗

pyRMG: A framework for high-throughput, large-cell DFT calculations on supercomputers

Exascale computing delivers the raw power to simulate ever larger and more chemically realistic systems, but realizing this potential requires codes that can efficiently use thousands of processors. Our real-space multigrid (RMG) density functional theory (DFT) code’s grid-decomposition approach scales nearly linearly with the number of graphics processing units (GPUs), even for simulations exceeding thousands of atoms. This scalability makes RMG a compelling tool for high-throughput DFT studies of materials that would otherwise be bottlenecked in other codes (for example, by global fast Fourier transforms in plane-wave DFT). However, the limited workflow infrastructure for RMG has thus far constrained its adoption to a small user community. In this work, we present pyRMG, a Python package designed to streamline the setup and execution of RMG DFT calculations. Built on the pymatgen and ASE (Atomic Simulation Environment) computational materials science Python packages, pyRMG automates input generation and convergence checking, and it integrates with modern job schedulers (e.g., Flux) on leadership-class platforms such as Frontier and Perlmutter. Here, we demonstrate pyRMG for a high-throughput study of strain effects in 2D 2L-Bi 2 Se 3 /2L-NbSe 2 heterostructures, which offers chemical insights into this system and shows that RMG-based workflows can converge with limited user intervention.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High-throughput, combinatorial synthesis of multimetallic nanoclusters

Significance Multielement nanomaterials hold great promise for various applications due to their widely tunable surface chemistry, yet it remains challenging to efficiently study this multidimensional space. Conventional approaches are typically slow and depend on serendipity, while a robust and general synthesis is still lacking among increasingly complex compositions. We report a high-throughput technique for combinatorial compositional design (formulation in solution phases) and rapid synthesis (within seconds) of ultrafine multimetallic nanoclusters with a homogeneous alloy structure. We synthesized and screened the PtPdRhRuIrFeCoNi compositional space using scanning droplet cell electrochemistry, with two promising catalysts quickly identified and further verified in a rotating disk setup. The reported high-throughput approach establishes a facile and reliable pipeline to significantly accelerate material discovery in multimetallic nanomaterials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Automated segmentation of soft X-ray tomography: Native cellular structure with submicron resolution at high-throughput for whole-cell quantitative imaging in yeast

Soft X-ray tomography (SXT) is an invaluable tool for quantitatively analyzing cellular structures at suboptical isotropic resolution. However, it has traditionally depended on manual segmentation, limiting its scalability for large datasets. Here, we leverage a deep learning-based autosegmentation pipeline to segment and label cellular structures in hundreds of cells across three Saccharomyces cerevisiae strains. This task-based pipeline uses manual iterative refinement to improve segmentation accuracy for key structures, including the cell body, nucleus, vacuole, and lipid droplets, enabling high-throughput and precise phenotypic analysis. Using this approach, we quantitatively compared the three-dimensional (3D) whole-cell morphometric characteristics of wild-type, VPH1-GFP, and vac14 strains, uncovering detailed strain-specific cell and organelle size and shape variations. We show the utility of SXT data for precise 3D curvature analysis of entire organelles and cells and detection of fine morphological features using surface meshes. Our approach facilitates comparative analyses with high spatial precision and statistical throughput, uncovering subtle morphological features at the single-cell and population level. This workflow significantly enhances our ability to characterize cell anatomy and supports scalable studies on the mesoscale, with applications in investigating cellular architecture, organelle biology, and genetic research across diverse biological contexts.

Chen, Jianhua [Lawrence Berkeley National Laborato↗