Search NASA⌕ Search

SEARCH · Search NASA

Results for “tomography problems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

HamPerf: A Hamiltonian-Oriented Approach to Quantum Benchmarking

Quantum computing technologies are undergoing rapid development. The different qubit modalities being considered for quantum computing each have their strengths and weaknesses, making it challenging to compare their performance relative to each other and the state-of-the-art in classical high-performance computing. To better understand the utility of a given quantum processor and to assess when and how it will be able to advance the frontiers of computational science, researchers need a robust approach to quantum benchmarking. A variety of approaches have been proposed, many of which characterize the presence of noise in current quantum devices. These efforts include component-level performance metrics, such as randomized benchmarking and gate set tomography; high-level application-dependent metrics; and devicelevel metrics, such as the Quantum Volume. However, it remains unclear how low-level metrics, such as fidelities and decoherence times, and global device metrics, such as Quantum Volume, relate to the computational utility and practical limitations of quantum processors to solve useful problems. In this paper, we describe our Hamiltonian-oriented approach to quantum benchmarking called HamPerf. Where previous application-dependent approaches specify a suite of benchmarking circuits inspired by applications, we place the problem Hamiltonian at the center. Our strategy allows us to probe the computational performance of a quantum processor on standardized and relevant problem sets, agnostic of the algorithms and hardware used to solve them; it also provides fundamental insights into how device characteristics correlate with computational utility.

Butko, Anastasiia↗

PHOTOMETRIC AND SPECTROSCOPIC STUDIES OF MASSIVE BINARIES IN THE LARGE MAGELLANIC CLOUD. I. INTRODUCTION AND ORBITS FOR TWO DETACHED SYSTEMS: EVIDENCE FOR A MASS DISCREPANCY?

The stellar mass-luminosity relation is poorly constrained by observations for high-mass stars. We describe our program to find eclipsing massive binaries in the Magellanic Clouds using photometry of regions rich in massive stars, and our spectroscopic follow-up to obtain radial velocities and orbits. Our photometric campaign identified 48 early-type periodic variables, of which only 15 (31%) were found as part of the microlensing surveys. Spectroscopy is now complete for 17 of these systems, and in this paper we present analysis of the first two, LMC 172231 and ST2-28, simple detached systems of late-type O dwarfs of relatively modest masses. Our orbit analysis yields very precise masses ({approx}2%), and we use tomography to separate the components and determine effective temperatures by model fitting, necessary for determining accurate (0.05-0.07 dex) bolometric luminosities in combination with the light-curve analysis. Our approach allows more precise comparisons with evolutionary theory than previously possible. To our considerable surprise, we find a small, but significant, systematic discrepancy: all of the stars are slightly undermassive, by typically 11% (or overluminous by 0.2 dex) compared with that predicted by the evolutionary models. We examine our approach for systematic problems, but find no satisfactory explanation. The discrepancy is in the same sense as the long-discussed and elusive discrepancy between the masses measured from stellar atmosphere analysis with the stellar evolutionary models, and might suggest that either increased rotation or convective overshooting is needed in the models. Additional systems will be discussed in future papers of this series, and will hopefully confirm or refute this trend.

79 ASTRONOMY AND ASTROPHYSICS↗

Universal framework for simultaneous tomography of quantum states and SPAM noise

We present a general denoising algorithm for performing simultaneous tomography of quantum states and measurement noise. This algorithm allows us to fully characterize state preparation and measurement (SPAM) errors present in any quantum system. Our method is based on the analysis of the properties of the linear operator space induced by unitary operations. Given any quantum system with a noisy measurement apparatus, our method can output the quantum state and the noise matrix of the detector up to a single gauge degree of freedom. We show that this gauge freedom is unavoidable in the general case, but this degeneracy can be generally broken using prior knowledge on the state or noise properties, thus fixing the gauge for several types of state-noise combinations with no assumptions about noise strength. Such combinations include pure quantum states with arbitrarily correlated errors, and arbitrary states with block independent errors. This framework can further use available prior information about the setting to systematically reduce the number of observations and measurements required for state and noise detection. Our method effectively generalizes existing approaches to the problem, and includes as special cases common settings considered in the literature requiring an uncorrelated or invertible noise matrix, or specific probe states.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-C-204-04: Patient Specific Proton Stopping Powers Estimation by Combining Proton Radiography and Prior-Knowledge X-Ray CT Information

Purpose: The material relative stopping power (RSP) uncertainty is the highest contributor to the range uncertainty in proton therapy. The purpose of this work is to develop a robust and systematic method that yields accurate, patient specific, RSP by combining 1) pre-treatment x-ray CT and 2) daily proton radiograph of the patient. Methods: The method is formulated as a linear least-square optimization problem (min||Ax-B||2). The parameter A represents the pathlength crossed by the proton in each material. The RSPs for the materials (water equivalent thickness (WET)/physical thickness) are denoted by x. B is the proton radiograph expressed as WET crossed. The problem is minimized using a convex-conic optimization algorithm with xi<xi+1 constraint. The Gammex RMI-465 phantom, with 13 material inserts, is used to investigate the optimal RSPs. The proton radiograph (B) is produced using Geant4 simulation. The matrix A is computed by calculating proton trajectories through the CT with the cubic-spline approach. Geant4 RSPs are used as reference and the clinical HU-RSP calibration curve is used as comparison. The convergence is investigated as a function of the number of angles and protons used. The radiographs angle which yield the most accurate RSPs are investigated. Results: Optimization with 9 angles and 104 protons/angle yields precise RSP (<0.75%) for all materials, except plastic lung (1.5%). Average deviation relative to Geant4 RSP is 0.5% and 3.5% using HU-RSP. Using more than two angles or more than 4×103 proton does not further increase the RSP estimate accuracy. The insert distance to the beam initial plane is related to the RSP error for this insert material. Specific filters are applied on the proton angle and energy loss to remove nuclear interaction artefacts. Conclusion: The proposed formulation of the problem with prior knowledge x-ray CT demonstrates serious potential to increase the accuracy of present RSP estimates.

60 APPLIED LIFE SCIENCES↗

Fast compressed sensing-based CBCT reconstruction using Barzilai-Borwein formulation for application to on-line IGRT

Purpose: Compressed sensing theory has enabled an accurate, low-dose cone-beam computed tomography (CBCT) reconstruction using a minimal number of noisy projections. However, the reconstruction time remains a significant challenge for practical implementation in the clinic. In this work, we propose a novel gradient projection algorithm, based on the Gradient-Projection-Barzilai-Borwein formulation (GP-BB), that handles the total variation (TV)-norm regularization-based least squares problem for the CBCT reconstruction in a highly efficient manner, with speed acceptable for routine use in the clinic. Methods: CBCT is reconstructed by minimizing an energy function consisting of a data fidelity term and a TV-norm regularization term. Both terms are simultaneously minimized by calculating the gradient projection of the energy function with the step size determined using an approximate Hessian calculation at each iteration, based on the Barzilai-Borwein formulation. To speed up the process, a multiresolution optimization is used. In addition, the entire algorithm was designed to run with a single graphics processing unit (GPU) card. To evaluate the performance, the Shepp-Logan numerical phantom, the CatPhan 600 physical phantom, and a clinically-treated head-and-neck patient were acquired from the TrueBeam system (Varian Medical Systems, Palo Alto, CA). For each scan, in total, 364 projections were acquired in a 200 deg. rotation. The imager has 1024 x 768 pixels with 0.388 x 0.388-mm resolution. This was down-sampled to 512 x 384 pixels with 0.776 x 0.776-mm resolution for reconstruction. Evenly spaced angles were subsampled and used for varying the number of projections for the image reconstruction. To assess the performance of our GP-BB algorithm, we have implemented and compared with three compressed sensing-type algorithms, the two of which are popular and published (forward-backward splitting techniques), and the other one with a basic line-search technique. In addition, the conventional Feldkamp-Davis-Kress (FDK) reconstruction of the clinical patient data is compared as well. Results: In comparison with the other compressed sensing-type algorithms, our algorithm showed convergence in {<=}30 iterations whereas other published algorithms need at least 50 iterations in order to reconstruct the Shepp-Logan phantom image. With the CatPhan phantom, the GP-BB algorithm achieved a clinically-reasonable image with 40 projections in 12 iterations, in less than 12.6 s. This is at least an order of magnitude faster in reconstruction time compared with the most recent reports utilizing GPU technology given the same input projections. For the head-and-neck clinical scan, clinically-reasonable images were obtained from 120 projections in 34-78 s converging in 12-30 iterations. In this reconstruction range (i.e., 120 projections) the image quality is visually similar to or better than the conventional FDK reconstructed images using 364 projections. This represents a dose reduction of nearly 67% (120/364 projections) while maintaining a reasonable speed in clinical implementation. Conclusions: In this paper, we proposed a novel, fast, low-dose CBCT reconstruction algorithm using the Barzilai-Borwein step-size calculation. A clinically viable head-and-neck image can be obtained within {approx}34-78 s while simultaneously cutting the dose by approximately 67%. This makes our GP-BB algorithm potentially useful in an on-line image-guided radiation therapy (IGRT).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The emerging role of 4D synchrotron X-ray micro-tomography for climate and fossil energy studies: five experiments showing the present capabilities at beamline 8.3.2 at the Advanced Light Source

Here, continuous improvements at X-ray imaging beamlines at synchrotron light sources have made dynamic synchrotron X-ray micro-computed tomography (SXR-µCT) experiments more routinely available to users, with a rapid increase in demand given its tremendous potential in very diverse areas. In this work a survey of five different four-dimensional SXR-µCT experiments is presented, examining five different parameters linked to the evolution of the investigated system, and tackling problems in different areas in earth sciences. SXR-µCT is used to monitor the microstructural evolution of the investigated sample with the following variables: (i) high temperature, observing in situ oil shale pyrolysis; (ii) low temperature, replicating the generation of permafrost; (iii) high pressure, to study the invasion of supercritical CO 2 in deep aquifers; (iv) uniaxial stress, to monitor the closure of a fracture filled with proppant, in shale; (v) reactive flow, to observe the evolution of the hydraulic properties in a porous rock subject to dissolution. For each of these examples, it is shown how dynamic SXR-µCT was able to provide new answers to questions related to climate and energy studies, highlighting the significant opportunities opened recently by the technique.

47 OTHER INSTRUMENTATION↗

Compact Beta Particle/Positron Imager for Plant Biology

The 11CO2 tracer is used to facilitate plant biology research towards optimization of plant productivity, biofuel development and carbon sequestration in biomass. Positron emission tomography (PET) imaging has been used to study carbon transport in live plants using 11CO2. Plants typically have very thin leaves resulting in little medium for the emitted positrons to undergo an annihilation event. For the emitted positron from 11C decay approximately 1mm of water equivalent material is needed for positron annihilation. Thus most of the positrons do not annihilate inside the leaf, resulting in limited sensitivity for PET imaging. To address this problem we have developed a compact beta-positive beta-minus particle (BPBM) imager for 11CO2 leaf imaging. The detector is based on a Hamamatsu H8500 position sensitive photomultiplier tube optically coupled via optical grease and a 3mm thick glass plate to a 0.5mm thick Eljin EJ-212 plastic scintillator. The detector is equipped with a flexible arm to allow its placement and orientation on the leaf of the plant of interest while maintaining the leaf&#x27;s original orientation. We are planning to utilize the imaging device at the Duke University Phytotron to investigate dynamic carbon transport differences between invasive and native species.

09 BIOMASS FUELS↗

The large-volume high-pressure facility at GSECARS: A 'Swiss-army-knife' approach to synchrotron-based experimental studies

A number of new techniques have been developed at the large-volume press (LVP) high-pressure facility at the GeoSoilEnviroCARS (GSECARS) sector of the advanced photon source (APS). This article describes the 10 MN (1000 T) and 2.5 MN (250 T) hydraulic presses in the insertion device (ID) and bending magnet (BM) beamlines, respectively, with several apparatus and various diffraction and imaging techniques developed since the inception of the facility. Several Kawai-type high-pressure modules, whose second-stage anvils range from 10 mm to 25.4 mm in edge lengths, are used in the hydraulic presses, with pressure (P) and temperature (T) capabilities up to 30 GPa and 3000 K. A DIA-type apparatus can be compressed in both presses for studies requiring large sample volumes. A deformation DIA (D-DIA) has been developed to allow controlled deformation studies on both crystalline and glass materials, using monochromatic diffraction and imaging, up to 20 GPa and 1800 K. A high-pressure tomography apparatus is available for conducting tomography studies at high P and T, with a typical spatial resolution of a few micrometers. Toroidal anvil modules provide large 2{theta} angles for studies of non-crystalline materials, and a new large D-DIA module is under construction for double-stage megabar pressure generation as well as deformation on large samples with the capability of acoustic emission detection. The flexible design of the monochromator at the BM beamline makes it feasible to switch between monochromatic and white-beam mode during an experiment, ideal for monochromatic imaging studies (e.g., high-P tomography) with energy-dispersive diffraction for pressure measurements. A new angle-dispersive diffraction technique has been developed for high P-T crystallography studies, where a solid-state detector is step-scanned, thereby collecting a large number of angle-dispersive spectra over a wide range of photon energies recorded in the multi-channel analyzer. An ultrasonic interferometer is available and has been used in several high-pressure modules for acoustic velocity measurements. These unique features allow world-wide users to select the best experimental techniques for tackling a wide range of problems relevant to earth and planetary science, materials science, physics, and chemistry. Scientific highlights are provided and future improvements and prospects are discussed.

43 PARTICLE ACCELERATORS↗

Measuring the evolution of intergalactic gas from z = 0 to 5 using the kinematic Sunyaev–Zel’dovich effect

ABSTRACT A complete census of baryons in the late Universe is a long-standing challenge due to the intermediate temperate and rarefied character of the majority of cosmic gas. To gain insight into this problem, we extract measurements of the kinematic Sunyaev–Zel’dovich (kSZ) effect from the cross-correlation of angular redshift fluctuations maps, which contain precise information about the cosmic density and velocity fields, and cosmic microwave background maps high-pass filtered using aperture photometry; we refer to this technique as angular redshift fluctuations (ARF)–kSZ tomography. Remarkably, we detect significant cross-correlation for a wide range of redshifts and filter apertures using 6dF galaxies, BOSS galaxies, and SDSS quasars as tracers, yielding a 11σ detection of the kSZ effect. We then leverage these measurements to set constraints on the location, density, and abundance of gas inducing the kSZ effect, finding that this gas resides outside dark matter haloes, presents densities ranging from 10 to 250 times the cosmic average, and comprises half of cosmic baryons. Taken together, these findings indicate that ARF–kSZ tomography provides a nearly complete census of intergalactic gas from z = 0 to 5.

Chaves-Montero, Jonás↗

Data-centric machine learning in quantum information science

Abstract We propose a series of data-centric heuristics for improving the performance of machine learning systems when applied to problems in quantum information science. In particular, we consider how systematic engineering of training sets can significantly enhance the accuracy of pre-trained neural networks used for quantum state reconstruction without altering the underlying architecture. We find that it is not always optimal to engineer training sets to exactly match the expected distribution of a target scenario, and instead, performance can be further improved by biasing the training set to be slightly more mixed than the target. This is due to the heterogeneity in the number of free variables required to describe states of different purity, and as a result, overall accuracy of the network improves when training sets of a fixed size focus on states with the least constrained free variables. For further clarity, we also include a ‘toy model’ demonstration of how spurious correlations can inadvertently enter synthetic data sets used for training, how the performance of systems trained with these correlations can degrade dramatically, and how the inclusion of even relatively few counterexamples can effectively remedy such problems.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-E-T-420: Failure Effects Mode Analysis for Trigeminal Neuralgia Frameless Radiosurgery

Purpose: Functional radiosurgery has been used successfully in the treatment of trigeminal neuralgia but presents significant challenges to ensuring the high prescription dose is delivered accurately. A review of existing practice should help direct the focus of quality improvement for this treatment regime. Method: Failure modes and effects analysis was used to identify the processes in preparing radiosurgery treatment for TN. The map was developed by a multidisciplinary team including: neurosurgeon, radiation oncology, physicist and therapist. Potential failure modes were identified for each step in the process map as well as potential causes and end effect. A risk priority number was assigned to each cause. Results: The process map identified 66 individual steps (see attached supporting document). Corrective actions were developed for areas of high risk priority number. Wrong site treatment is at higher risk for trigeminal neuralgia treatment due to the lack of site specific pathologic imaging on MR and CT – additional site specific checks were implemented to minimize the risk of wrong site treatment. Failed collision checks resulted from an insufficient collision model in the treatment planning system and a plan template was developed to address this problem. Conclusion: Failure modes and effects analysis is an effective tool for developing quality improvement in high risk radiotherapy procedures such as functional radiosurgery.

60 APPLIED LIFE SCIENCES↗

Four-dimensional phase space tomography from one-dimensional measurements of a hadron beam

In this paper, we use one-dimensional measurements to infer the four-dimensional phase space density of an accumulated proton beam in the Spallation Neutron Source (SNS) accelerator. The reconstruction was performed by maximizing the distribution’s entropy subject to the measurement constraints and thus represents the most conservative inference from the data. The reconstructed distribution reproduces the measured profiles down to the noise level, and simulations indicate that the problem is reasonably well constrained. Similar measurements could serve as benchmarks for beam dynamics simulations in the SNS or hadron accelerators.

43 PARTICLE ACCELERATORS↗

Microstructure and Properties of A356 Alloy Wheels Fabricated by Low-Pressure Die Casting with Local Squeeze

The low-pressure die-casting process (LPDC) is widely used in fabricating aluminum alloy automotive wheels. With good castability and mechanical properties, A356 alloys are important and common materials for LPDC wheels. However, in practical casting process, defects often appear, especially porosities in the wheel thick-walled parts (i.e., spoke) due to inadequate interdendritic feeding, which greatly decreases the mechanical properties. In this investigation, to deal with this problem, local squeeze (LS) was added in conventional LPDC to enhance the interdendritic feeding. The practical A356 alloy wheel castings were fabricated with different LS velocities and times. The quantitative characteristics of α-Al cells, Si particles, and porosities with and without the LS analyzed by optical microscope, scanning electron microscope, and 3D x-ray computed tomography were compared. Their effects on the tensile and impact properties were discussed. The results have shown that the LS can increase the cooling rate and feed shrinkage of spoke parts, hence resulting in finer grains and denser microstructure. In result, the properties of spoke parts were improved with the LS.

36 MATERIALS SCIENCE↗

Development of computational small animal models and their applications in preclinical imaging and therapy research

The development of multimodality preclinical imaging techniques and the rapid growth of realistic computer simulation tools have promoted the construction and application of computational laboratory animal models in preclinical research. Since the early 1990s, over 120 realistic computational animal models have been reported in the literature and used as surrogates to characterize the anatomy of actual animals for the simulation of preclinical studies involving the use of bioluminescence tomography, fluorescence molecular tomography, positron emission tomography, single-photon emission computed tomography, microcomputed tomography, magnetic resonance imaging, and optical imaging. Other applications include electromagnetic field simulation, ionizing and nonionizing radiation dosimetry, and the development and evaluation of new methodologies for multimodality image coregistration, segmentation, and reconstruction of small animal images. This paper provides a comprehensive review of the history and fundamental technologies used for the development of computational small animal models with a particular focus on their application in preclinical imaging as well as nonionizing and ionizing radiation dosimetry calculations. An overview of the overall process involved in the design of these models, including the fundamental elements used for the construction of different types of computational models, the identification of original anatomical data, the simulation tools used for solving various computational problems, and the applications of computational animal models in preclinical research. The authors also analyze the characteristics of categories of computational models (stylized, voxel-based, and boundary representation) and discuss the technical challenges faced at the present time as well as research needs in the future.

61 RADIATION PROTECTION AND DOSIMETRY↗

PhytoBeta imager: a positron imager for plant biology

Several positron emitting radioisotopes such as 11C and 13N can be used in plant biology research. The 11CO2 tracer is used to facilitate plant biology research toward optimization of plant productivity, biofuel development and carbon sequestration in biomass. Positron emission tomography (PET) imaging has been used to study carbon transport in live plants using 11CO2. Because plants typically have very thin leaves, little medium is present for the emitted positrons to undergo an annihilation event. The emitted positrons from 11C (maximum energy 960 keV) could require up to approximately 4 mm of water equivalent material for positron annihilation. Thus many of the positrons do not annihilate inside the leaf, resulting in limited sensitivity for PET imaging. To address this problem we have developed a compact beta-positive, beta-minus particle imager (PhytoBeta imager) for 11CO2 leaf imaging. The detector is based on a Hamamatsu H8500 position sensitive photomultiplier tube optically coupled via optical grease to a 0.5 mm thick Eljen EJ-212 plastic scintillator. The detector is equipped with a flexible arm to allow its placement and orientation over or under the leaf to be studied while maintaining the leaf&#x27;s original orientation. To test the utility of the system the detector was used to measure carbon translocation in a leaf of the spicebush (Lindera benzoin) under two transient light conditions.

09 BIOMASS FUELS↗

Resolution-enhanced X-ray fluorescence microscopy via deep residual networks

Abstract Multimodal hard X-ray scanning probe microscopy has been extensively used to study functional materials providing multiple contrast mechanisms. For instance, combining ptychography with X-ray fluorescence (XRF) microscopy reveals structural and chemical properties simultaneously. While ptychography can achieve diffraction-limited spatial resolution, the resolution of XRF is limited by the X-ray probe size. Here, we develop a machine learning (ML) model to overcome this problem by decoupling the impact of the X-ray probe from the XRF signal. The enhanced spatial resolution was observed for both simulated and experimental XRF data, showing superior performance over the state-of-the-art scanning XRF method with different nano-sized X-ray probes. Enhanced spatial resolutions were also observed for the accompanying XRF tomography reconstructions. Using this probe profile deconvolution with the proposed ML solution to enhance the spatial resolution of XRF microscopy will be broadly applicable across both functional materials and biological imaging with XRF and other related application areas.

36 MATERIALS SCIENCE↗

Accelerating full waveform inversion via source stacking and cross-correlations

SUMMARY Accurate synthetic seismic wavefields can now be computed in 3-D earth models using the spectral element method (SEM), which helps improve resolution in full waveform global tomography. However, computational costs are still a challenge. These costs can be reduced by implementing a source stacking method, in which multiple earthquake sources are simultaneously triggered in only one teleseismic SEM simulation. One drawback of this approach is the perceived loss of resolution at depth, in particular because high-amplitude fundamental mode surface waves dominate the summed waveforms, without the possibility of windowing and weighting as in conventional waveform tomography. This can be addressed by redefining the cost-function and computing the cross-correlation wavefield between pairs of stations before each inversion iteration. While the Green’s function between the two stations is not reconstructed as well as in the case of ambient noise tomography, where sources are distributed more uniformly around the globe, this is not a drawback, since the same processing is applied to the 3-D synthetics and to the data, and the source parameters are known to a good approximation. By doing so, we can separate time windows with large energy arrivals corresponding to fundamental mode surface waves. This opens the possibility of designing a weighting scheme to bring out the contribution of overtones and body waves. It also makes it possible to balance the contributions of frequently sampled paths versus rarely sampled ones, as in more conventional tomography. Here we present the results of proof of concept testing of such an approach for a synthetic 3-component long period waveform data set (periods longer than 60 s), computed for 273 globally distributed events in a simple toy 3-D radially anisotropic upper mantle model which contains shear wave anomalies at different scales. We compare the results of inversion of 10 000 s long stacked time-series, starting from a 1-D model, using source stacked waveforms and station-pair cross-correlations of these stacked waveforms in the definition of the cost function. We compute the gradient and the Hessian using normal mode perturbation theory, which avoids the problem of cross-talk encountered when forming the gradient using an adjoint approach. We perform inversions with and without realistic noise added and show that the model can be recovered equally well using one or the other cost function. The proposed approach is computationally very efficient. While application to more realistic synthetic data sets is beyond the scope of this paper, as well as to real data, since that requires additional steps to account for such issues as missing data, we illustrate how this methodology can help inform first order questions such as model resolution in the presence of noise, and trade-offs between different physical parameters (anisotropy, attenuation, crustal structure, etc.) that would be computationally very costly to address adequately, when using conventional full waveform tomography based on single-event wavefield computations.

Romanowicz, Barbara↗

Data consistency conditions for truncated fanbeam and parallel projections

Purpose: In image reconstruction from projections, data consistency conditions (DCCs) are mathematical relationships that express the overlap of information between ideal projections. DCCs have been incorporated in image reconstruction procedures for positron emission tomography, single photon emission computed tomography, and x-ray computed tomography (CT). Building on published fanbeam DCCs for nontruncated projections along a line, the authors recently announced new DCCs that can be applied to truncated parallel projections in classical (two-dimensional) image reconstruction. These DCCs take the form of polynomial expressions for a weighted backprojection of the projections. The purpose of this work was to present the new DCCs for truncated parallel projections, to extend these conditions to truncated fanbeam projections on a circular trajectory, to verify the conditions with numerical examples, and to present a model of how DCCs could be applied with a toy problem in patient motion estimation with truncated projections. Methods: A mathematical derivation of the new parallel DCCs was performed by substituting the underlying imaging equation into the mathematical expression for the weighted backprojection and demonstrating the resulting polynomial form. This DCC result was extended to fanbeam projections by a substitution of parallel to fanbeam variables. Ideal fanbeam projections of a simple mathematical phantom were simulated and the DCCs for these projections were evaluated by fitting polynomials to the weighted backprojection. For the motion estimation problem, a parametrized motion was simulated using a dynamic version of the mathematical phantom, and both noiseless and noisy fanbeam projections were simulated for a full circular trajectory. The fanbeam DCCs were applied to extract the motion parameters, which allowed the motion contamination to be removed from the projections. A reconstruction was performed from the corrected projections. Results: The mathematical derivation revealed the anticipated polynomial behavior. The conversion to fanbeam variables led to a straight-forward weighted fanbeam backprojection which yielded the same function and therefore the same polynomial behavior as occurred in the parallel case. Plots of the numerically calculated DCCs showed polynomial behavior visually indistinguishable from the fitted polynomials. For the motion estimation problem, the motion parameters were satisfactorily recovered and ten times more accurately for the noise-free case. The reconstructed images showed that only a faint trace of the motion blur was still visible after correction from the noisy motion-contaminated projections. Conclusions: New DCCs have been established for fanbeam and parallel projections, and these conditions have been validated using numerical experiments with truncated projections. It has been shown how these DCCs could be applied to extract parameters of unwanted physical effects in tomographic imaging, even with truncated projections.

62 RADIOLOGY AND NUCLEAR MEDICINE↗