Search NASA⌕ Search

SEARCH · Search NASA

Results for “total temperature”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Maternal provisioning interacts with incubation temperature to affect hatchling mercury exposure in an oviparous reptile

The thermal environment experienced by developing embryos can influence the utilization of maternally provisioned resources. Despite being particularly consequential for oviparous ectotherms, these dynamics are largely unexplored within ecotoxicological frameworks. Here, we test if incubation temperature interacts with maternally transferred mercury to affect subsequent body burdens and tissue distributions of mercury in hatchling American alligators (Alligator mississippiensis). Nine clutches of alligator eggs were collected from a mercury-contaminated reservoir and incubated at either female- or male-promoting temperatures. Total mercury (THg) concentration was measured in egg yolk collected during incubation and in a suite of tissues collected from hatchlings. THg concentrations in residual yolk and blood were higher in hatchlings incubated at cooler, female-promoting temperatures compared to the warmer, male-promoting temperatures. THg concentrations in most tissues were positively correlated with THg concentrations in blood and dermis, and egg yolk THg concentration was the best predictor of THg concentration in many resultant tissues. Furthermore, our results highlight a hereto unknown role of the developmental environment in mediating tissue specific uptake of contaminants in an oviparous reptile.

59 BASIC BIOLOGICAL SCIENCES↗

Computational/experimental investigation of staged injection into a Mach 2 flow

The stage normal injection of two jets of air into a Mach 2 freestream behind a rearward-facing step has been investigated using laser-induced iodine fluorescence and laser doppler anemometry techniques. A detailed data set has been compiled that includes profiles of pressure, temperature, two components of velocity, and mole fraction of the injectant at 44 locations, plus planar surveys of pressure, temperature, velocity, and mole fraction. A companion numerical study was performed using the SPARK Navier-Stokes code. Good overall agreement was observed for this complex, highly three-dimensional flowfield. Discrepancies were observed in the computed and measured total temperatures, turbulent mixing, and shock strengths. The effect of grid resolution was investigated by calculating solutions on grids of 60,000 points, 200,000 points, and 450,000 points. Differences in the solutions on the two finer grids were small. The effect of turbulence modeling was investigated by calculating solutions with three different algebraic models for the jet turbulence. Overall, the turbulence models were found to have the greatest effect on the numerical solutions, followed by the grid resolution and the injectant Mach number.

Eklund, D. R.↗

Aerodynamic heating in large cavities in an array of RSI tiles

A large panel of reusable surface insulation (RSI) tiles including lost tile cavities was aerothermally tested in the Langley 8 foot high temperature structures tunnel to determine both the heat load within the cavities and the structural performance of the RSI surrounding the cavities. Tests were conducted with a turbulent boundary layer at a nominal free stream Mach number of 6.6, a total temperature of 1800 K, a Reynolds number per meter of 5 million, and a dynamic pressure of 62 kPa. The maximum aerodynamic heating to the floor of the cavity was two to three times the normal surface heating. The cavity heating rates agreed with data from other facilities and were successfully correlated with an empirical equation. A zippering failure occurred to a tile downstream of a double tile cavity when the separated flow attached to the floor of the cavity and forced the tile from its position.

Hunt, L. R.↗

Experimental investigation of aerodynamic performance of cooled turbine vanes at gas- to collant-temperature ratios up to 2.75

The results of an experimental investigation of the aerodynamic performance of two geometrically similar turbine vanes with different cooling designs are presented. The test vanes were a convection-film-cooled vanes and a transpiration-cooled vane. A solid uncooled vane with the same aerodynamic profile as the cooled vane was also tested. Four vanes of each type were tested in an annular sector cascade. The cooled vanes were tested at primary to coolant temperature ratios of 1.0, 1.75, and 2.75 and a coolant to primary pressure ratios of 1.0, 1.2, and 1.5. This resulted in coolant flows up to about 10 percent of the primary flow. The principal measurements were surveys of vane exit total pressure, total temperature, and static pressure. The report includes a brief description of the test facility and the design of the test vanes. The test results presented include weight flow and efficiency data for the uncooled vanes and coolant flow, primary flow, and efficiency data as functions of the cooling variables for the cooled vanes.

Stabe, R. G.↗

Temperature-Corrected Model of Turbulence in Hot Jet Flows

An improved correction has been developed to increase the accuracy with which certain formulations of computational fluid dynamics predict mixing in shear layers of hot jet flows. The CFD formulations in question are those derived from the Reynolds-averaged Navier-Stokes equations closed by means of a two-equation model of turbulence, known as the k-epsilon model, wherein effects of turbulence are summarized by means of an eddy viscosity. The need for a correction arises because it is well known among specialists in CFD that two-equation turbulence models, which were developed and calibrated for room-temperature, low Mach-number, plane-mixing-layer flows, underpredict mixing in shear layers of hot jet flows. The present correction represents an attempt to account for increased mixing that takes place in jet flows characterized by high gradients of total temperature. This correction also incorporates a commonly accepted, previously developed correction for the effect of compressibility on mixing.

Abdol-Hamid, Khaled S.↗

Optical measurement of static temperature and hydroxyl radical profiles in a hydrogen-fueled supersonic combustor

Profiles of static temperature and hydroxyl radical concentration were measured in a two-dimensional supersonic combustor test section 22.8 cm downstream of hydrogen injection. A high-pressure gas generator supplied vitiated air to the test section at Mach 2.44, atmospheric pressure, and a total temperature of about 2240 K. Room-temperature hydrogen was injected through a 0.40-cm step slot at Mach 1 and matched pressure. The measurements utilized a noninterfering spectral line absorption technique in which narrow ultraviolet emission lines of the hydroxyl electronic transition are absorbed by the broader absorption lines in the combustion gas. Comparison of the measured temperature profiles with theoretical calculations showed good agreement.

Gaugler, R. E.↗

Aerodynamic heating and loading within large open cavities in cone and cone-cylinder-flare models at Mach 6.7

The aerodynamic heating and loading distributions within large cavities exposed by surface openings to hypersonic flow were determined in the 8-foot high-temperature structures tunnel. Cone and cone-cylinder-flare models with cavities having regular and irregular surface-opening shapes were aerothermally tested at various angles of attack up to 30 deg. Tests were conducted at a Mach number of 6.7, a total temperature of 1800 K, a dynamic pressure of 80 kPa, and a stream unit Reynolds number of 6,000,000 per meter. The results showed that the heating rates at internal reattachment were generally lower but of the same order as the corresponding external heating rates; however, other internal heating rates were an order of magnitude lower. The internal flow showed characteristics of being funneled into jets or being dispersed dependent upon the internal surface contour.

Hunt, R. L.↗

Bluntness and Supersaturation Effects on the Second Mode Instability in Mach 10 Flow

An experimental campaign was conducted on a 7-degree half-angle cone in the NASA Langley Research Center 31-Inch Mach 10 Tunnel to investigate the impact of nosetip radius and freestream supersaturation on the development of the second mode instability. The model was instrumented with surface-mounted Kulite® and PCB® pressure transducers and thermocouples. Power spectral density plots demonstrate the anticipated trends of the second mode instability weakening and shifting to lower frequencies with increased bluntness. Heat transfer measurements suggest laminar flow over the bulk of the model for most testing conditions, with evidence of transition by the cone base for the sharpest nosetip (R = 0.15 mm) at the higher unit Reynolds numbers. The dynamic surface pressure and heat transfer measurements show that reducing the temperature of the freestream to a supersaturated state has a significant stabilizing effect on the model boundary layer. The surface measurements are observed to be highly dependent on the level of clustering in the freestream. Significant changes in surface pressure spectra due to total temperature reduction are first noted below T0= 948 K, while more substantial fluctuation reductions are found below T0= 810 K.

Hypersonics↗

Exhaust-Gas Pressure and Temperature Survey of F404-GE-400 Turbofan Engine

An exhaust-gas pressure and temperature survey of the General Electric F404-GE-400 turbofan engine was conducted in the altitude test facility of the NASA Lewis Propulsion System Laboratory. Traversals by a survey rake were made across the exhaust-nozzle exit to measure the pitot pressure and total temperature. Tests were performed at Mach 0.87 and a 24,000-ft altitude and at Mach 0.30 and a 30,000-ft altitude with various power settings from intermediate to maximum afterburning. Data yielded smooth pressure and temperature profiles with maximum jet temperatures approximately 1.4 in. inside the nozzle edge and maximum jet temperatures from 1 to 3 in. inside the edge. A low-pressure region located exactly at engine center was noted. The maximum temperature encountered was 3800 R.

Walton, James T.↗

Transpiration cooling in the locality of a transverse fuel jet for supersonic combustors

The objective of the current work was to determine the feasibility of transpiration cooling for the relief of the local heating rates in the region of a sonic, perpendicular, fuel jet of gaseous hydrogen. Experiments were conducted to determine the interaction between the cooling required and flameholding limits of a transverse jet in a high-enthalpy, Mach 3 flow in both open-jet and direct-connect test mode. Pulsed shadowgraphs were used to illustrate the flow field. Infrared thermal images indicated the surface temperatures, and the OH(-) emission of the flame was used to visualize the limits of combustion. Wall, static presures indicated the location of the combustion within the duct and were used to calculate the combustion efficiency. The results from both series of tests at facility total temperatures of 1700 K and 2000 K are presented.

Northam, G. Burton↗

Unsteady Flow Field in a Multistage Axial Flow Compressor

The flow field in a multistage compressor is three-dimensional, unsteady, and turbulent with substantial viscous effects. Some of the specific phenomena that has eluded designers include the effects of rotor-stator and rotor-rotor interactions and the physics of mixing of velocity, pressure, temperature and velocity fields. An attempt was made, to resolve experimentally, the unsteady pressure and temperature fields downstream of the second stator of a multistage axial flow compressor which will provide information on rotor-stator interaction effects and the nature of the unsteadiness in an embedded stator of a three stage axial flow compressor. Detailed area traverse measurements using pneumatic five hole probe, thermocouple probe, semi-conductor total pressure probe (Kulite) and an aspirating probe downstream of the second stator were conducted at the peak efficiency operating condition. The unsteady data was then reduced through an ensemble averaging technique which splits the signal into deterministic and unresolved components. Auto and cross correlation techniques were used to correlate the deterministic total temperature and velocity components (acquired using a slanted hot-film probe at the same measurement locations) and the gradients, distributions and relative weights of each of the terms of the average passage equation were then determined. Based on these measurements it was observed that the stator wakes, hub leakage flow region, casing endwall suction surface corner region, and the casing endwall region away from the blade surfaces were the regions of highest losses in total pressure, lowest efficiency and highest levels of unresolved unsteadiness. The deterministic unsteadiness was found to be high in the hub and casing endwall regions as well as on the pressure side of the stator wake. The spectral distribution of hot-wire and kulite voltages shows that at least eight harmonics of all three rotor blade passing frequencies are present at this measurement location. In addition to the basic three rotor blade passing frequencies (R1, R2 and R3) and their harmonics, various difference frequencies such as (2R1 -R2) and (2R3-R2) and their harmonics are also observed. These difference frequencies are due to viscous and potential interactions between rotors 1, 2 and 3 which are sensed by both the total pressure and aspirating probes at this location. Significant changes occur to the stator exit flow features with passage of the rotor upstream of the stator. Because of higher convection speeds of the rotor wake on the suction surface of the downstream stator than on the pressure side, the chopped rotor wake was found to be arriving at different times on either side of the stator wake. As the rotor passes across the stator.

Suryavamshi, N.↗

An Experimental Study of Jet Exhaust Simulation

An investigation was conducted to determine the effect of varying the jet exhaust ratio of specific heats, gas constants, and temperatures on jet interference on afterbody drag. Jet exhaust simulation parameters were also evaluated. In addition to air, three other exhaust gases, each with a different value of each of the gas parameters, were tested. The range of the ratios of specific heats, gas constants, and total temperatures of the four gases are identified. Tests were made using a single nacelle model with afterbodies having boattail angles of 10 degrees and 20 degrees with sonic and Mach two jet exits. Wind tunnel tests were conducted through a Mach number range of 0.60 to 1.20 and a Reynolds number per meter from 10.06 million to 14.05 million.

Compton, W. B., III↗

The effects of temperature on supersonic jet noise emission

This paper examines the generation of sound produced by high temperature supersonic jets. In particular, the question of the importance of supersonic instability waves to noise emission is considered relative to the role of Kelvin-Helmholtz (K-H) instability waves. Here, these waves are taken to be synonymous with the Mach emission process. Jet total temperatures from 313 to 1534 K are investigated using an axisymmetric water cooled supersonic nozzle designed for Mach 2. The aerodynamic and acoustic results of this study indicate that the dominant noise contributors are the K-H waves over the entire temperature range. Good agreement between measured and numerically predicted plume properties are obtained and an elliptic nozzle is used to demonstrate reduction of the K-H waves.

Seiner, John M.↗

Development of a temperature-compensated hot-film anemometer system for boundary-layer transition detection on high-performance aircraft

A hot-film constant-temperature anemometer (CTA) system was flight-tested and evaluated as a candidate sensor for determining boundary-layer transition on high-performance aircraft. The hot-film gage withstood an extreme flow environment characterized by shock waves and high dynamic pressures, although sensitivity to the local total temperature with the CTA indicated the need for some form of temperature compensation. A temperature-compensation scheme was developed and two CTAs were modified and flight-tested on the F-104/Flight Test Fixture (FTF) facility at a variety of Mach numbers and altitudes, ranging from 0.4 to 1.8 and 5,000 to 40,000 ft respectively.

Chiles, H. R.↗

Development of a temperature-compensated hot-film anemometer system for boundary-layer transition detection on high-performance aircraft

A hot-film constant-temperature anemometer (CTA) system was flight-tested and evaluated as a candidate sensor for determining boundary-layer transition on high-performance aircraft. The hot-film gage withstood an extreme flow environment characterized by shock waves and high dynamic pressures, although sensitivity to the local total temperature with the CTA indicated the need for some form of temperature compensation. A temperature-compensation scheme was developed and two CTAs were modified and flight-tested on the F-104/Flight Test Fixture (FTF) facility at a variety of Mach numbers and altitudes, ranging from 0.4 to 1.8 and 5,000 to 40,000 ft respectively.

Chiles, H. R.↗

Coherent anti-Stokes Raman spectroscopy temperature measurements in a hydrogen-fueled supersonic combustor

Coherent anti-Stokes Raman spectroscopy (CARS) thermometry has been used to obtain static temperature cross sections in a three-dimensional supersonic combustor flowfield. Data were obtained in three spanwise planes downstream of a single normal fuel injector which was located downstream of a rearward-facing step. The freestream flow was nominally Mach 2 and was combustion heated to a total temperature of 1440 K (yielding a static temperature of about 800 K in the freestream) to simulate the inflow to a combustor operating at a flight Mach number of about 5.4. Since a broadband probe laser was used an instantaneous temperature sample was obtained with each laser shot at a repetition rate of 10 Hz. Thus root-mean-square (rms) temperatures and temperature probability density functions (pdf's) were obtained in addition to mean temperatures.

Smith, Michael W.↗

Qualitative Assessment of the Acoustic Disturbance Environment in the NASA LaRC 20-Inch MACH 6 Wind Tunnel

An experimental investigation was conducted on a 5-degree-half-angle cone with a flare in a conventional Mach 6 wind tunnel to examine the effect of facility noise on boundary layer transition. The effect of tunnel noise was inferred by comparing transition onset locations determined from the present test to that previously obtained in a Mach 6 quiet tunnel. Together, the two sets of experiments are believed to represent the first direct comparison of transition onset between a conventional and a quiet hypersonic wind tunnel using a common test model. In the present conventional hypersonic tunnel experiment, adiabatic wall temperatures were measured and heat transfer distributions were inferred on the cone flare model at zero degree angle of attack over a range of length Reynolds numbers (2 x 10(exp 6) to 10 x 10(exp 6)) which resulted in laminar and turbulent flow. Wall-to-total temperature ratio for the transient heating measurements and the adiabatic wall temperature measurements were 0.69 and 0.86, respectively. The cone flare nosetip radius was varied from 0.0001 to 0.125-inch to examine the effects of bluntness on transition onset. At comparable freestream conditions the transition onset Reynolds number obtained on the cone flare model in the conventional "noisy" tunnel was approximately 25% lower than that measured in the low disturbance tunnel.

Horvath, Thomas J.↗