Search NASA⌕ Search

SEARCH · Search NASA

Results for “transmission operation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

An Overview of Renewable Energy Desk Activities for Power Grid Operations and Planning

This document summarizes how grid operators can address gaps in their planning and operations to maintain reliability as they pursue clean energy goals. When transitioning to higher renewable energy levels, many system operators configure a dedicated renewable energy desk to manage variable renewable energy resource operation. Establishing such a desk in the control room can be a key step in the modernization effort. A renewable energy desk in a control room is a specialized hub focused solely on monitoring, predicting, and managing the influx of energy from renewable sources.

ENERGY PLANNING, POLICY, AND ECONOMY,POWER TRANSMI↗

A General State Estimation Formulation for Three-Phase Unbalanced Power Systems

Almost all of the three-phase state estimation algorithms assume existence of a reference bus whose phase angles are perfectly balanced. This assumption is quite realistic for transmission systems, and also for most distribution systems that are connected to a strong transmission system where transmission side can modeled by a balanced reference bus. However, for distribution systems having high penetration of renewable sources or for microgrids operating in islanded mode, the assumption of a balanced reference bus will not be realistic. While there are recent publications focusing on this problem, formulation of the three-phase unbalanced state estimation problem with proper treatment of the reference bus remains unaddressed. In this paper, a new formulation will be described where an accurate state estimation solution can be obtained for any unbalanced threephase system irrespective of its operating conditions (balanced or highly unbalanced), configuration (isolated microgrid, connected to transmission system, etc.) and whether or not it contains any synchronous generators. Validation of the proposed formulation will be carried out via simulations.

State Estimation, Distribution System, Unbalanced ↗

High-Temperature RF Transmission Loss Characteristics of Platinum–Inconel 600 and Platinum–304 Steel Interconnects

Radio frequency (RF) transmission losses that occur at electronic interconnects is currently an important limitation of wireless sensors and other electronic device packages that must operate in high-temperature environments. Herein, in-situ RF transmission losses were measured for two types of interconnects: platinum (Pt) wire bonded to an Inconel 600 coaxial cable; and Pt-wire bonded to a block of 304 steel. Heating the Pt wire/Inconel interconnects at 800 °C for up to 200 hours were found to be very stable with no measurable transmission losses. In contrast, Pt wire/304 steel block interconnects examined over similar test periods at 800 °C exhibited gradual increases in transmission losses leveling off at 10, 38 and 85 mdB at 400 MHz, 700 MHz, and 1 GHz, respectively. Increasing the test temperature to 900 °C caused further elevated transmission losses of 30, 70 and 108 mdB at the same reported frequencies. By comparison, temperature cycling of the Pt wire/304 steel interconnects between room temperature and 900 °C was found to cause more significant degradation. In particular, four thermal cycles from room temperature to 900 °C resulted in losses of 75, 271, and 482 mdB at the same reported frequencies. Parabolic oxidation relative to the RF skin depth in the 304 steel block at the tested frequencies are discussed as possible reasons for the transmission losses during the isothermal soaks, whereas interconnect degradation due to differences in thermal expansion between Pt and 304 steel are primarily responsible for transmission losses caused by high temperature cycling.

304 steel↗

CyDER: A Cyber Physical Co-simulation Platform for Distributed Energy Resources in Smartgrids

The CyDER project aimed at developing an open-source, modular and scalable co-simulation platform for power grids with large shares of Distributed Energy Resources (DERs). The project partners are the Lawrence Berkeley National Lab (LBNL), Lawrence Livermore National Lab (LLNL), PG&E, SolarCity, and ChargePoint. The prime recipient is LBNL; SolarCity and ChargePoint were partners for the project’s first two years. Increased DER integration introduces a number of challenges in power grid operation including a more dynamic interaction between the transmission grid and distribution grids, and increased modeling complexity. Although specialized software exists to precisely model different components of the power system, it is far from trivial to integrate all various models and perform a holistic simulation. Instead of replicating all models in a common simulation program, a commonly accepted approach to tackle this model diversity is to couple third-party simulators and models through a co-simulation platform that coordinates information exchange among the various components. Following this line of research, this project’s objective was to develop a co-simulation platform based on a widely accepted industrial standard called Functional Mockup Interface (FMI). Within this process, the project developed models compliant with the FMI standard, called Functional Mockup Units (FMUs), and used them to perform various operational and planning power system analyses. Relying and building upon an industrial standard is the main differentiation of this project compared with previous or parallel efforts in the co-simulation area. Particular emphasis was put on delivering software utilities to facilitate setting up and running co-simulations by end-users. Furthermore, a strong aspect of this project is demonstrating that co-simulation techniques can be used to perform Hardware-in-the-Loop (HIL) simulations that couple software components (e.g., simulated models) with hardware components (e.g., real devices such PV systems and batteries). The long-term goal of CyDER project is to help establish FMI as a powerful standard for co-simulation and promote adoption by electric utilities and other interested stakeholders. The main accomplishments of the project include the development of several FMUs including distribution and transmission grid models, PV inverters with Volt/Var/Watt controllers, batteries, and predictive optimal controllers. Additionally, a unique software package was developed, called SimulatorToFMU, which is capable of exporting any Python-driven simulator or Python script as an FMU. This is an important contribution towards establishing FMI as one of the main co-simulation standards, because more and more third-party programs for sub-system modeling and simulation are delivered with Python APIs. The CyDER platform was used to perform PV hosting capacity analyses in real utility feeders with and without smart inverter controls, battery storage, and EV charging. Smart inverter controls include conventional Volt/Var/Watt controls for reactive power support and active power curtailment, but also predictive controls that optimize the charging and discharging profile of the battery connected on the DC side in order to minimize the customer’s economic benefit. Finally, an important result of this project is delivering an experimental setup that consists of residential-scale PV inverters with battery storage, a real-time grid simulator with an ideal voltage source as grid emulator, and micro Phasor Measurement Units (PMUs). All these components and additional software modules are coupled to one another using the FMI standard and can be co-simulated with the CyDER platform.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Storage Futures Study: Grid Operational Impacts of Widespread Storage Deployment

This report, the fifth in the Storage Futures Study series, uses cost-driven scenarios from the ReEDS model as a starting point to examine the operational impacts of grid-scale storage deployment and relationships between this deployment and the contribution of variable renewable energy. We use commercial production cost modeling software to evaluate hourly operation of five scenarios that reach between 210 gigawatts (GW) and 930 GW of installed storage by 2050. We find that storage plays an important role in these power systems between now and 2050 - by storing the lowest-marginal cost generation (often, overgeneration from solar or wind plants) and generating energy during the highest net load periods of the day and year. Storage helps with the integration of variable renewable energy and by providing an important resource to provide continued reliable power.

battery↗

Propagating Parameter Uncertainty in Power System Nonlinear Dynamic Simulations Using a Koopman Operator-Based Surrogate Model

In this work, we propose a Koopman operator-based surrogate model for propagating parameter uncertainties in power system nonlinear dynamic simulations. First, we augment a priori known state-space model by reformulating parameters deemed uncertain as pseudo-state variables. Then, we apply the Koopman operator theory to the resulting state-space model and obtain a linear dynamical system model. This transformation allows us to analyze the evolution of the system dynamics through its Koopman eigenfunctions, eigenvalues, and modes. Of particular importance for this letter, the obtained linear dynamical system is a surrogate that enables the evaluation of parameter uncertainties by simply perturbing the initial conditions of the Koopman eigenfunctions associated with the pseudo-state variables. Simulations carried out on the New England test system reveal the excellent performance of the proposed method in terms of accuracy and computational efficiency.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Evaluating efficacy of indoor non-pharmaceutical interventions against COVID-19 outbreaks with a coupled spatial-SIR agent-based simulation framework

Contagious respiratory diseases, such as COVID-19, depend on sufficiently prolonged exposures for the successful transmission of the underlying pathogen. It is important that organizations evaluate the efficacy of non-pharmaceutical interventions aimed at mitigating viral transmission among their personnel. We have developed a operational risk assessment simulation framework that couples a spatial agent-based model of movement with an agent-based SIR model to assess the relative risks of different intervention strategies. By applying our model on MIT’s Stata center, we assess the impacts of three possible dimensions of intervention: one-way vs unrestricted movement, population size allowed onsite, and frequency of leaving designated work location for breaks. We find that there is no significant impact made by one-way movement restrictions over unrestricted movement. Instead, we find that reducing the frequency at which individuals leave their workstations combined with lowering the number of individuals admitted below the current recommendations lowers the likelihood of highly connected individuals within the contact networks that emerge, which in turn lowers the overall risk of infection. We discover three classes of possible interventions based on their epidemiological effects. By assuming a direct relationship between data on secondary attack rates and transmissibility in the agent-based SIR model, we compare relative infection risk of four respiratory illnesses, MERS, SARS, COVID-19, and Measles, within the simulated area, and recommend appropriate intervention guidelines.

60 APPLIED LIFE SCIENCES↗

Investigation of HVAC operation strategies for office buildings during COVID-19 pandemic

To minimize the indoor transmission of contaminants, such as the virus that can lead to COVID-19, buildings must provide the best indoor air quality possible. Improving indoor air quality can be achieved through the building's HVAC system to decrease any concentration of indoor contaminants by dilution and/or by source removal. However, doing so has practical downsides on the HVAC operation that are not always quantified in the literature. This paper develops a temporal simulation capability that is used to investigate the indoor virus concentration and operational cost of an HVAC system for two mitigation strategies: (1) supplying 100% outdoor air into the building and (2) using different HVAC filters, including MERV 10, MERV 13, and HEPA filters. These strategies are applied to a hypothetical medium office building consisting of five occupied zones and located in a cold and dry climate. We modeled the building using the Modelica Buildings library and developed new models for HVAC filtration and virus transmission to evaluate COVID-19 scenarios. We show that the ASHRAE-recommended MERV 13 filtration reduces the average virus concentration by about 10% when compared to MERV 10 filtration, with an increase in site energy consumption of about 3%. In contrast, the use of 100% outdoor air reduces the average indoor concentration by about an additional 1% compared to MERV 13 filtration, but significantly increases heating energy consumption. Use of HEPA filtration increases the average indoor concentration and energy consumption compared to MERV 13 filtration due to the high resistance of the HEPA filter.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Flexible Operation of Natural Gas Power Plants in Texas: Startup and Shutdown Durations and Nitrogen Dioxide Emissions

This dataset provides insights into historical flexible operation of natural gas power plants in Texas, with a focus on startup and shutdown events. The dataset includes tables summarizing startup and shutdown durations as well as nitrogen oxide (NOx) emission factors during these events, and compares these emission factors with those observed during all other operating phases (referred to here as “steady-state operation”). The dataset is derived using the U.S. Environmental Protection Agency (EPA)’s Clean Air Markets Program Data (CAMPD). Historical hourly data from 2015–2024, including electricity generation, heat input, and NOx emission factors, are used for natural gas combined cycle units, combustion turbine units, and steam turbine units in Texas. This work was authored by the National Laboratory of the Rockies, operated by the Alliance for Energy Innovation, LLC, for the U.S Department of Energy (DOE) under contract no. DE-AC36-08GO28308. Funding was provided by the U.S. Department of Energy as part of its Grid Modernization Laboratory Consortium, a strategic partnership between DOE and the national laboratories to bring together leading experts, technologies, and resources to collaborate on the goal of modernizing the nation’s grid. The views expressed in the dataset do not necessarily represent the views of the DOE or the U.S. Government.

24 POWER TRANSMISSION AND DISTRIBUTION↗

MODAQ-BB (Modular Offshore Data Acquisition System - Blackbox) [SWR-24-72]

MODAQ-BB is a compact, rapid deployment data acquisition system that can withstand water depths up to 400m. Codenamed "BlackBox" (or simply BB), since its initial purpose was to track marine assets and record vital data streams that could later be recovered in the event of a mishap - much like a traditional black box used in aviation and shipping, the name has stuck. MODAQ BlackBox is a battery-operable microcontroller platform with internal inertial sensing, GPS, satellite communications, and additional I/O (input/output) support in a depth-rated pressure enclosure. Since BB is self-contained and relatively compact, it can be quickly deployed with minimal effort. The enclosure can be clamped to a tube (such as part of a railing) or mast in a location with unobstructed view of the sky using the available clamp accessory or a common hose clamp. While BB is designed to operate unattended, users can configure what data are uploaded and the frequency of satellite transmissions. Once data are uploaded, they can be relayed to an email distribution list, the MODAQ:Web operational dashboard, or a custom destination. BB has found utility in the National Laboratory of the Rockies' (NLR's) Waterpower projects beyond its original vision and has been configured and successfully deployed in more traditional data-gathering applications where a simple, battery-operated solution was indicated. As part of the MODAQ family, BB fills a space in the spectrum of missions that can be supported that were previously impractical using the traditional MODAQ hardware architecture due to factors such as weight, size, and cost.

Raye, Robert↗

Development and Implementation of Fault-Correction Algorithms in Fault Detection and Diagnostics Tools

A fault detection and diagnostics (FDD) tool is a type of energy management and information system that continuously identifies the presence of faults and efficiency improvement opportunities through a one-way interface to the building automation system and the application of automated analytics. Building operators on the leading edge of technology adoption use FDD tools to enable median whole-building portfolio savings of 8%. Although FDD tools can inform operators of operational faults, currently an action is always required to correct the faults to generate energy savings. A subset of faults, however, such as biased sensors, can be addressed automatically, eliminating the need for staff intervention. Automating this fault “correction” can significantly increase the savings generated by FDD tools and reduce the reliance on human intervention. Doing so is expected to advance the usability and technical and economic performance of FDD technologies. This paper presents the development of nine innovative fault auto-correction algorithms for Heating, Ventilation, and Air Conditioning pi(HVAC) systems. When the auto-correction routine is triggered, it overwrites control setpoints or other variables to implement the intended changes. It also discusses the implementation of the auto-correction algorithms in commercial FDD software products, the integration of these strategies with building automation systems and their preliminary testing.

field testing↗

On the Low Risk of Subsynchronous Resonance (SSR) in Type III Wind Turbines Operating in Grid-Forming Control

We have shown in a previous work that the risk of sub-synchronous resonance (SSR) between a wind power plant with Type III wind turbines and series-compensated transmission lines is low when the wind turbines in the plant are operated in grid-forming mode, instead of the standard grid-following mode. The fundamental mechanism behind the improved damping characteristics is explained in this paper by modeling the positive and negative sequence impedances of Type III wind turbines for GFM operation mode. It is discovered that the GFM control naturally acts against the negative resistance of Type III wind turbines that results from an interaction between the proportional gain of the rotor-side converter current controller and negative slip. The developed sequence impedance models and improved damping behavior are verified using PSCAD simulations of a 2.5-MW Type III GFM wind turbine. The modeling predictions are also supported by experimentally measuring the sequence impedance response of a 2.5-MW Type III wind turbine during operation in GFL and GFM modes.

grid-following turbine↗

Leveraging Existing Assets for Long Duration Energy Storage

Increased renewables penetration to electrical grid is necessary to reduce overall emissions from the electrical power generation sector. Nonetheless, its integration creates challenges to grid operators who must match the power being generated by intermittent renewables and other traditional energy sources with the demand from consumers, while ensuring the reliability and power quality for the entire system. Energy storage has been proposed as an alternative to natural gas peaking plants and a form to deliver excess renewable energy generation at times of peak demand. For energy storage to provide benefits to end customers (energy consumers), it must be reliable, efficient, and cost effective. The Illinois Sustainable Technology Center (ISTC), one of the surveys that integrate the Prairie Research Institute (PRI), aims to develop a Center for Energy Storage at Existing Assets (CESEA) at UIUC with the participation of Waste Pressure Corp and Ecotek Engineering USA LLC. CESEA will focus on LDES systems that can integrate to existing infrastructure in a manner that reduces the initial capital expenditure and demonstrates the ability to repurpose fossil assets that would otherwise become stranded, to serve the energy transition. CESEA aims to leverage UIUC’s unique facilities to validate LDES systems performance at a relevant operating environment. UIUC’s facilities include a 85-MW combined heat and power (CHP) power plant, two (2) solar PV plants totaling over 18 MWdc of installed capacity, an electrical grid along with a substation at transmission and distribution voltages, a 22-mile gas pipeline network operating at two pressure levels, along with steam and chilled water distribution networks. The new LDES systems will connect to the existing UIUC grid through a new test electrical station, which will have the capacity to accommodate additional connections to test new devices and technologies as part of future CESEA R&D activities. The test electrical station will contain meters, instrumentation, and controls to accurately capture data and allow optimization of control algorithms. CESEA will initially focus on technologies that: i) utilize existing equipment or facilities to perform at least one of the process steps in LDES (charging, storage, or discharging), ii) leverage mature or commercially available components or controls, iii) show potential for cost-leadership in 10+ hour storage at a commercial scale. Initial technologies that were identified to meet these criteria include Compressed Gas Energy Storage (CGES), and TES. CGES stores electricity by raising the pressure of a compressible gas inside a control volume and converting the stored energy to electricity via expansion-generation. CGES is a generalization of CAES that covers any working gas (not just air). A successful CGES demo will help to circumvent many challenges faced by CAES (long development times due to site prospecting, high cost of compression and storage, heat recovery management, etc.) by: 1) utilizing existing infrastructure (compressors, pipelines, underground storage or pressure vessels) used in the transportation and storage of industrial gases for LDES charging and storage; 2) deploying over sites already-developed for industrial applications with minor additional work; 3) leveraging the price structure of commercial industrial gas to cover the costs of electricity used during charging. A previous DOE-sponsored conceptual study (DE-FE-0032018) estimated the levelized cost of energy of a 1.1 MW / 17 MWh CGES system at $0.08/kWh, with a commercial 10x scale system cost estimated at <$0.04/kWh (Giardinella, 2022). The pilot-sized system was estimated to avoid up to 2693 tons of CO2/year.

25 ENERGY STORAGE↗

Long-Term High-Temperature High-Pressure Cable for Geothermal Logging Tools

Downhole logging tools are commonly used to characterize multi-thousand-foot geothermal wells. The elevated temperatures, pressures, and harsh chemical environments present significant challenges for the long-term operation of these tools, especially when real-time data transmission to the surface is required via data cable lines. Teflon-based single or multi-conductor cables with grease-filled cable heads are typically used for downhole tools. However, over extended periods of operation, the gr

15 GEOTHERMAL ENERGY↗

Real-Time Federated Cyber-Transmission-Distribution Testbed Architecture for the Resiliency Analysis

With the ongoing automation driven by the push toward the smart electric grid and the advancement in associated cyber infrastructure, the interaction between physical [electric transmission and distribution (T&D) systems], cyber (communication, automation, and control), and human (grid operators and decision-makers) is increasingly becoming more complex. This creates the requirement of analyzing the effect of the transmission system on the distribution system and vice versa with consideration of the additional complexity of the cyber infrastructure. Such an integrated testbed will also help with resiliency analysis, where resiliency refers to the ability of the system to continue serving energy to the critical loads even with limited extreme contingencies. Interaction of the physical power grid with the cyber layer can be effectively modeled using real-time (RT) simulator for developing and validating various operational and control algorithms. Testbeds using RT simulators with multiple capabilities have been developed at different institutions. Still, no single existing testbed can offer full scalability while simultaneously meeting high fidelity requirements for resiliency experimentation. Co-simulating federated testbed assets can provide a scalable experimentation platform that can be leveraged for verification and validation. In this article, an architecture is developed for federated cyber-physical testbed. A local federation with two real-time simulators is developed: real-time digital simulator (RTDS) and OPAL-RT have been interfaced using VILLAS framework for end-to-end testing. Also, a real-time linear predictor is developed and integrated here to address the communication latency impact on geographically allocated federated RT simulation. Finally, resiliency analysis tools are formulated and utilized for T&D systems. Finally as an illustrative use case, the resiliency of a T&D test system is simulated, and the results are analyzed. A 179-bus Western Electricity Coordinating Council (WECC) transmission system is developed using OPAL-RT/ HYPERSIM, and a modified IEEE 13 node feeder system is modeled in RTDS/RSCAD and interfaced for resiliency analysis.

42 ENGINEERING↗

Mixed domain coherent link with electrically reconfigurable IMDD and coherent modes for O-band data center applications

We report the first O-band link with electrically reconfigurable intensity-modulation direct-detection (IMDD) and coherent operation using custom silicon photonic chips packaged with commercial electronic chips. Transmission below the KP4-FEC threshold is shown using commercial 53 Gbaud PAM4 digital signal processing (DSP) for 16QAM (200 Gbps/ λ ) and PAM4 (100 Gbps/ λ ). Efficient operation of the packaged full link at 12 and 11.2 pJ/bit is achieved for the PAM4 and 16QAM modes, respectively.

Misak, Stephen (ORCID:0000000154973084)↗

On the feasibility of using physics-informed machine learning for underground reservoir pressure management

In this work, we evaluate the feasibility of using physics-informed machine learning (PIML) for underground energy-related pressure management. To this end, we develop a PIML framework to manage underground reservoir pressures by training neural networks to determine fluid extraction rates for dedicated extraction wells during fluid injection operations given a range of reservoir conditions (e.g., transmissivity and storativity). We implement an automatically-differentiable analytical physics model of fluid flow in porous media within the PIML framework as a proxy for more complicated models. This allows us to execute a sufficient number of training scenarios to fully evaluate the feasibility of using PIML to support pressure management activities. We quantify the number of physics-model parameters required for automatic differentiation to become more efficient than finite-difference gradient calculations. We use a simple scenario with a single injector, extractor, and critical location for our feasibility analysis. We evaluate the effect of the size of the training dataset (i.e., the number of reservoir condition samples) on the accuracy and efficiency of the PIML framework. For an equivalent number of model evaluations, the larger training dataset took less time to train and produced a neural network that was able to more accurately manage reservoir pressures. We also evaluate the effect of the training dataset batch size (i.e., number of reservoir condition samples used to update the neural network coefficients during training; i.e., how the training dataset is partitioned). While training ran faster with larger batch sizes, they produced neural networks that managed pressures less accurately. We demonstrate the approach on a more complex scenario involving 10 injectors, 10 extractors, and 4 critical locations (a relatively high well density of 20 wells/km2). We provide the number of forward and adjoint model evaluations required in each case as an indication of the feasibility of using PIML for pressure management when more complicated physics models with longer execution times are used.

54 ENVIRONMENTAL SCIENCES↗

Reversible plasmonic switching in a graphene nanoresonator loaded with a core – shell quantum dot

A model of an all-plasmonic switch based on a graphene waveguide integrated with a stub nanoresonator loaded with a quantum dot is considered. Using the full-wave numerical simulation, it is shown that successive on/off switching of the control surface plasmon – polariton wave at the input of the waveguide leads to a change in the phase of the signal plasmon – polariton wave in the nanoresonator by π. This causes reversible switching of the device operation regime – from almost complete blocking to stable transmission of the signal plasmon – polariton wave through the waveguide. The effect is implemented at rates of ∼0.5 THz for infrared electromagnetic waves localised in a device with a switching region of 40 × 20 nm. (paper)

36 MATERIALS SCIENCE↗