Search NASA⌕ Search

SEARCH · Search NASA

Results for “two phase flow boiling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Two-Phase Flow Technology Developed and Demonstrated for the Vision for Exploration

NASA s vision for exploration will once again expand the bounds of human presence in the universe with planned missions to the Moon and Mars. To attain the numerous goals of this vision, NASA will need to develop technologies in several areas, including advanced power-generation and thermal-control systems for spacecraft and life support. The development of these systems will have to be demonstrated prior to implementation to ensure safe and reliable operation in reduced-gravity environments. The Two-Phase Flow Facility (T(PHI) FFy) Project will provide the path to these enabling technologies for critical multiphase fluid products. The safety and reliability of future systems will be enhanced by addressing focused microgravity fluid physics issues associated with flow boiling, condensation, phase separation, and system stability, all of which are essential to exploration technology. The project--a multiyear effort initiated in 2004--will include concept development, normal-gravity testing (laboratories), reduced gravity aircraft flight campaigns (NASA s KC-135 and C-9 aircraft), space-flight experimentation (International Space Station), and model development. This project will be implemented by a team from the NASA Glenn Research Center, QSS Group, Inc., ZIN Technologies, Inc., and the Extramural Strategic Research Team composed of experts from academia.

Sankovic, John M.↗

Computations of Drop Collision and Coalescence

Computations of drops collisions, coalescence, and other problems involving drops are presented. The computations are made possible by a finite difference/front tracking technique that allows direct solutions of the Navier-Stokes equations for a multi-fluid system with complex, unsteady internal boundaries. This method has been used to examine the various collision modes for binary collisions of drops of equal size, mixing of two drops of unequal size, behavior of a suspension of drops in linear and parabolic shear flows, and the thermal migration of several drops. The key results from these simulations are reviewed. Extensions of the method to phase change problems and preliminary results for boiling are also shown.

Tryggvason, Gretar↗

TOUGHREACT User's Guide: A Simulation Program for Non-isothermal Multiphase Reactive Geochemical Transport in Variably Saturated Geologic Media, V1.2.1

Coupled modeling of subsurface multiphase fluid and heat flow, solute transport, and chemical reactions can be applied to many geologic systems and environmental problems, including geothermal systems, diagenetic and weathering processes, subsurface waste disposal, acid mine drainage remediation, contaminant transport, and groundwater quality. TOUGHREACT has been developed as a comprehensive non-isothermal multi-component reactive fluid flow and geochemical transport simulator to investigate these and other problems. A number of subsurface thermo-physical-chemical processes are considered under various thermohydrological and geochemical conditions of pressure, temperature, water saturation, and ionic strength. TOUGHREACT can be applied to one-, two- or three-dimensional porous and fractured media with physical and chemical heterogeneity. The code can accommodate any number of chemical species present in liquid, gas and solid phases. A variety of equilibrium chemical reactions are considered, such as aqueous complexation, gas dissolution/exsolution, and cation exchange. Mineral dissolution/precipitation can take place subject to either local equilibrium or kinetic controls, with coupling to changes in porosity and permeability and capillary pressure in unsaturated systems. Chemical components can also be treated by linear adsorption and radioactive decay. The first version of the non-isothermal reactive geochemical transport code TOUGHREACT was developed (Xu and Pruess, 1998) by introducing reactive geochemistry into the framework of the existing multi-phase fluid and heat flow code TOUGH2 (Pruess, 1991). TOUGHREACT was further enhanced with the addition of (1) treatment of mineral-water-gas reactive-transport under boiling conditions, (2) an improved HKF activity model for aqueous species, (3) gas species diffusion coefficients calculated as a function of pressure, temperature, and molecular properties, (4) mineral reactive surface area formulations for fractured and porous media, and (5) porosity, permeability, and capillary pressure changes owing to mineral precipitation/dissolution (Sonnenthal et al., 1998, 2000, 2001; Spycher et al., 2003a). Subsequently, TOUGH2 V2 was released with additional EOS modules and features (Pruess et al., 1999). The present version of TOUGHREACT includes all of the previous extensions to the original version, along with the replacement of the original TOUGH2 (Pruess, 1991) by TOUGH2 V2 (Pruess et al., 1999). TOUGHREACT has been applied to a wide variety of problems, some of which are included as examples, such as: (1) Supergene copper enrichment (Xu et al., 2001); (2) Mineral alteration in hydrothermal systems (Xu and Pruess, 2001a; Xu et al., 2004b; Dobson et al., 2004); (3) Mineral trapping for CO{sub 2} disposal in deep saline aquifers (Xu et al., 2003b and 2004a); (4) Coupled thermal, hydrological, and chemical processes in boiling unsaturated tuff for the proposed nuclear waste emplacement site at Yucca Mountain, Nevada (Sonnenthal et al., 1998, 2001; Sonnenthal and Spycher, 2000; Spycher et al., 2003a, b; Xu et al., 2001); (5) Modeling of mineral precipitation/dissolution in plug-flow and fracture-flow experiments under boiling conditions (Dobson et al., 2003); (6) Calcite precipitation in the vadose zone as a function of net infiltration (Xu et al., 2003); and (7) Stable isotope fractionation in unsaturated zone pore water and vapor (Singleton et al., 2004). The TOUGHREACT program makes use of 'self-documenting' features. It is distributed with a number of input data files for sample problems. Besides providing benchmarks for proper code installation, these can serve as a self-teaching tutorial in the use of TOUGHREACT, and they provide templates to help jump-start new applications. The fluid and heat flow part of TOUGHREACT is derived from TOUGH2 V2, so in addition to the current manual, users must have the manual of the TOUGH2 V2 (Pruess et al., 1999). The present version of TOUGHREACT provides the following TOUGH2 fluid property or 'EOS' (equation-of-state) modules: (1) EOS1 for water, or two waters with typical applications to hydrothermal problems, (2) EOS2 for multiphase mixtures of water and CO{sub 2} also with typical applications to hydrothermal problems, (3) EOS3 for multiphase mixtures of water and air with typical applications to vadose zone and nuclear waste disposal problems, (4) EOS4 that has the same capabilities as EOS3 but with vapor pressure lowering effects due to capillary pressure, (5) EOS9 for single phase water (Richards equation) with typical applications to ambient temperature and pressure reactive geochemical transport problems, and (6) ECO2N for multiphase mixtures of water, CO{sub 2} and NaCl with typical applications to CO{sub 2} disposal in deep brine aquifers.

54 ENVIRONMENTAL SCIENCES↗

FY23 Report on Water NSTF Testing at Two-Phase Conditions: Off-normal Scenarios

Under support from the Department of Energy (DOE) and the Office of Advanced Reactor Technologies (ART), a large-scale test facility has been constructed at Argonne National Laboratory to generate NQA-1 qualified validation data for passive decay heat removal systems in advanced reactors. The Natural convection Shutdown heat removal Test Facility (NSTF) reflects key features of a ½ scale, water-based, Reactor Cavity Cooling System (RCCS) and is intended to study the behavior, bound performance, and ultimately guide design decisions for passive decay heat removal systems for advanced reactors. In addition to the experimental activities detailed in this report, a supportive computational modeling effort is on-going which has been demonstrated to significantly strengthen the experimental program while also improving accuracy of the computer models. Together these create a mutually beneficial relationship integral to meeting the overall program objective of examining the heat removal performance of the RCCS concept. This report details the experimental activities and upgrades performed during the program’s fifth year of water-based operation. The theme of this year of testing was examining off-normal scenarios. In practice, that meant examining scenarios with blockages or other design basis conditions. From a maintenance and capability standpoint that meant assessing valving options for implementing blockages, assessing drain and refill capabilities, and ensuring in all cases that operators could safely, efficiently, and repeatably bring the facility to an off-normal condition and return it to the normal operating state. In one notable case, no solution existed, nor was a solution commercially available, that met the facility needs for implementing blockages within the two-phase region of the chimney. A valve and feedthrough were custom-designed for NSTF to operate submerged in saturated water while being safely actuated from outside the tank. The fifth year of testing included eight matrix tests consisting of 162 hours of active heating, 9,735 kWh of electrical heating, with seven tests classified as Accepted per NQA-1 and one as Trending. All matrix tests were performed at two-phase flow conditions. The power parametric series from previous years was extended to include another scenario with a decay load equivalent to 1.75 MWt, full scale, further resolving the system flow oscillation response as a function of input power. A depletion test was performed to extend previous work and examine the system’s approach to stagnation and geysering that were not previously observed. This test began at an initial inventory level of 50%, prototypic power of 2.1 MWt, and employed an accelerated drain of 0.75 gpm plus boiloff until stagnation conditions were achieved and multiple geysering events were recorded. Further exploring the geysering phenomenon was a separate effects test examining static boiling in the risers and chimney. This static boiling test was performed at 48 kWe, a higher power than testing in the previous year, and included enhancements to the drain system to remove inventory in a better-controlled and more reliable manner. Two tests were performed, at prototypic conditions of 1.4 MWt and 2.4 MWt, respectively, examining the system response to throttled conditions in the singlephase region of the piping. A ball valve immediately before he riser inlet header was increasingly throttled, progressing the system through a repeatable pattern of two-phase oscillations and stable regimes before ultimately inducing stagnation and geysering. Concluding the year, two tests were performed at baseline conditions of 70% initial inventory level and 2.1 MWt of prototypic decay heat to examine both repeatability and the response to throttling within the two-phase region, at the inventory tank inlet using the custom valve mentioned above. The first such test repeated transient operating conditions and revealed significant sensitivity t

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Toward High Fidelity LES Simulations of 5 x 5 PWR Fuel Bundle with Mixing Vane

The present work illustrates one example of a computational fluid dynamics (CFD) application in the nuclear engineering field. Since CFD is one of the most powerful tools available at the actual state of the art that could in principle help and assist the design process, a compromise should be established between the accuracy of the CFD numerical model (RANS - LES - DNS) and the computational cost of the simulations. In this spirit, this work will present the computational results from two different CFD model categories, Large Eddy Simulations (LES) and Reynolds-averaged Navier-Stokes (RANS) models. Both treat the flow turbulence issue in two separate ways, which differ mostly in the resolution of the turbulence statistics and the computational cost. The single-phase hydraulic problem presented involves the steady-state turbulent flow field modelling and resolution around a scaled PWR mixing vane grid, designed by Westinghouse and tested by Texas A and M University. The role of the mixing vane/spacer grid is to enhance the turbulent mixing and hence heat transfer of the core coolant around fuel bundles, thus increasing the departure of nucleate boiling-critical heat flux (DNB-CHF) point, as well as important structural functions for the rods bundles. The authors numerically studied the flow field characteristics at the region downstream of the spacer grids and validated their results to particle imagery velocimetry (PIV) measurements. Dominguez and Hassan performed two-dimensional time resolved PIV (TR-PIV) measurements within a 5 x 5 PWR rod bundle with spacer-grids that utilized a matching index of refraction (MIR) approach. Their averaged data showed a rather uniform direction velocity profile after the spacer grid while the downstream illustrated a no slip wall profile. The available PIV flow field experimental results from Texas A and M show complex structures of the flow field downstream the mixing vanes with the formation of secondary flows that tend to enhance the turbulent heat transfer, due to the mixing vanes geometry itself. Computational results will be validated with the available experimental data.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Flow Boiling Heat Transfer Characteristics of Water for Metal-foam-filled Horizontal Tubes

The goal of this paper is to enhance the in-tube flow boiling heat transfer of water while accounting for potential increase in pressure drop. Metal foams are a class of cellular structure with large surface-area-to-volume ratio and tortuous structure which has shown promising results for various energy conversion and storage applications. The higher heat transfer area and higher nucleation sites density due to the porous media can effectively enhance the heat transfer of water in both single-phase and two-phase operations. This paper presents the local heat transfer and pressure drop measurements of water in a partially metal-foam-filled horizontal copper tube. The ranges of parameters in the experiments are: mass flux from 80 to 200 kg/s-m2, heat flux from 3.5 to 105 kW/m2, and vapor quality from subcooled to 0.3. The results in the metal-foam-filled tube are compared with that of the bare copper tube. The effect of metal foam on the thermal hydraulic characteristics is discussed and analyzed. In addition, the two-phase flow behavior in a transparent tube filled with the same metal foam was visualized and investigated by high-speed imaging system. The experiments were also conducted in the tube without the metal foam for comparison.

Nawaz, Kashif↗

CTF Theory Manual

Coolant-Boiling in Rod Arrays|Two Fluids (COBRA-TF) is a thermal/ hydraulic (T/H) simulation code designed for light water reactor (LWR) vessel analysis. It uses a two-fluid, three-field (i.e. fluid film, fluid drops, and vapor) modeling approach. Both sub-channel and 3D Cartesian forms of 9 conservation equations are available for LWR modeling. The code was originally developed by Pacific Northwest Laboratory in 1980 and had been used and modified by several institutions over the last few decades. COBRA-TF also found use at the Pennsylvania State University (PSU) by the Reactor Dynamics and Fuel Management Group (RDFMG) and has been improved, updated, and subsequently re-branded as CTF. As part of the improvement process, it was necessary to generate sufficient documentation for the open-source code which had lacked such material upon being adopted by RDFMG. This document serves mainly as a theory manual for CTF, detailing the many two-phase heat transfer, drag, and important accident scenario models contained in the code as well as the numerical solution process utilized. Coding of the models is also discussed, all with consideration for updates that have been made when transitioning from COBRA-TF to CTF. Further documentation outside of this manual is also available at RDFMG which focus on code input deck generation and source code global variable and module listings.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Computation of Space Shuttle high-pressure cryogenic turbopump ball bearing two-phase coolant flow

A homogeneous two-phase fluid flow model, implemented in a three-dimensional Navier-Stokes solver using computational fluid dynamics methodology is described. The application of the model to the analysis of the pump-end bearing coolant flow of the high-pressure oxygen turbopump of the Space Shuttle main engine is studied. Results indicate large boiling zones and hot spots near the ball/race contact points. The extent of the phase change of the liquid oxygen coolant flow due to the frictional and viscous heat fluxes near the contact areas has been investigated for the given inlet conditions of the coolant.

Chen, Yen-Sen↗

Flow Boiling Pressure Drop Characteristics of Next-generation Refrigerants in a Micro‑fin Copper Tube

This paper presents experimental frictional pressure-drop data for flow boiling of R-410A, R-134a, and next-generation alternatives R-454C, R-455A, R-1234yf, and R-1234ze(E) in a horizontal micro-fin copper tube. Tests were conducted over a range of mass fluxes and evaporation temperatures to characterize refrigerant-dependent two-phase pressure-drop behavior. The results show that frictional pressure gradient increased with mass flux and vapor quality and generally increased as evaporation temperature decreased, with liquid viscosity strongly affecting the observed trends. Among the evaluated correlations, the Goto et al. (2001) model gave the best overall agreement with the measurements before optimization. Further optimization of the Kuo and Wang (1996) and Goto et al. (2001) models reduced the overall mean absolute deviation to below 15%, with the optimized Goto (2001) model providing the most consistent predictions across all six refrigerants. The results support improved pressure-drop prediction and evaporator design for next-generation refrigerants in micro-fin tubes.

Hu, Yifeng [ORNL] (ORCID:0000000242875185)↗

Improvements to CTF Closure Models for Modelling of Two-Phase Flow

This report documents the efforts to improve the CTF prediction of void fraction and two-phase pressure drop by improving two-phase closure models. Previous validation activities have revealed that CTF tends to overpredict void fraction and two-phase pressure drop. In response to this, two approaches were taken to improve CTF’s predictive capabilities. Based on findings that the interfacial drag and subcooled boiling models significantly impact void prediction, alternative closure models for these physical effects were found and implemented into the code. An extensive assessment was performed by using the existing and newly added two-phase experimental data, which showed that void prediction, wall temperature, and two-phase pressure-drop results are improved by using the newly implemented models. A second approach for improving CTF modeling accuracy involved the use of a Bayesian calibration process that uses CTF validation data to optimize selected modeling coefficients and closure model multipliers to achieve a more accurate prediction of experimental results. A similar assessment was performed with calibrated models that improved the void and pressure-drop prediction for test cases that were both included and not included in the calibration dataset. Results of this study will be used to change the models used in CTF to achieve more accurate BWR analyses moving forward. This study also identified opportunities for improving additional closure models and other opportunities to use calibration techniques to improve CTF.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Experimental Studies on the Effect of Inlet Liquid Subcooling on the Chilldown Characteristics of Stainless Steel Tubes

Understanding transfer line chilldown process under microgravity is important for the efficient transfer of cryogenic propellants in space fuel depots to facilitate future long duration space missions. The present work is part of the ongoing efforts to develop and test a two-phase flow chilldown test section to study the complete chilldown process under sustained microgravity conditions onboard the International Space Station. In this study, ground-based chilldown experiments are carried out on a 60 cm long SS-316 test section with PF-5060 as the working fluid. The complete chilldown curve was obtained including the film, transition and nucleate boiling regimes along with the temperature transition points. The effect of inlet liquid subcooling on the behavior of the chilldown curves are presented. Further, the chilldown and heat flux curves are analyzed to obtain re-wetting/Leidenfrost and onset of nucleate boiling temperature transition points as well as the critical heat flux values. The effect of inlet liquid subcooling on regime-specific heat flux and heat transfer coefficients are also examined.

CFD↗

Boiling-Water Reactor Testing Capability in the Advanced Test Reactor

I-Loop is an irradiation facility that is currently being installed at the Advanced Test Reactor. It is a two-loop test facility capable of performing Light Water Reactor (LWR) irradiations in prototypic coolant conditions. The two loops are being installed to be capable of both Boiling Water Reactor (BWR) and Pressurized Water Reactor (PWR) pressure, temperature, and chemistry environments. Each loop is nominally dedicated as a BWR or PWR for simplicity of operations. In-reactor water loop testing that an I-Loop provides is key to the deployment of new accident tolerant fuel technologies and other advanced LWR fuel concepts. Currently, pressurized water loops are the only testing facilities available to test BWR fuel concepts. Their test environments are non-prototypic at higher pressure/temperature and at single-phase fluid flow conditions. This void in the LWR test bed capabilities is one that the I-Loop is uniquely situated to provide. This report discusses the mechanical design, thermal hydraulic calculations, and neutronic calculations of a proposed standard experiment of accident tolerant BWR fuel concepts. Mechanical design examines the geometry and features of the main components. Thermal hydraulic calculations examine the modeling and results of the two-phase flow options available. Lastly, neutronic calculations examine the Monte Carlo analysis of enrichment, heat rates, and flux spectrum.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A microgravity boiling and convective condensation experiment

A boiling and condensing test article consisting of two straight tube boilers, one quartz and one stainless steel, and two 1.5 m long glass-in-glass heat exchangers, on 6 mm ID and one 10 mm ID, was flown on the NASA KC-135 0-G aircraft. Using water as the working fluid, the 5 kw boiler produces two phase mixtures of varying quality for mass flow rates between 0.005 and 0.1 kg/sec. The test section is instrumented at eight locations with absolute and differential pressure transducers and thermocouples. A gamma densitometer is used to measure void fraction, and high speed photography records the flow regimes. A three axis accelerometer provides aircraft acceleration data (+ or - 0.01G). Data are collected via an analog-to-digital conversion and data acquisition system. Bubbly, annular, and slug flow regimes were observed in the test section under microgravity conditions. Flow oscillations were observed for some operating conditions and the effect of the 2-G pullout prior to the 0-G period was observed by continuously recording data throughout the parabolas. A total fo 300 parabolas was flown.

Kachnik, Leo↗

A Report from the Thermal Science Research Center (TSRC)

A vertical flow loop was designed and assembled to determine the local (circumferential and axial) and mean wall temperature distributions for single-phase and two-phase (subcooled and saturated) downward flow in both uniformly-heated and single-side heated vertical channels. Freon-11 was used as the working fluid in order to directly relate and compare the results with a previous experimental campaign which employed this same working fluid. For a given steady-state experiment, the following parameters were held constant: (1) exit pressure, (2) inlet temperature, and (3) mass velocity. For a given configuration of the 2.2 m long cylindrical channel test section, which had a 1.2 m long heated section, the applied heat rate was varied from zero through successive quasi-steady states to a level which corresponded to localized film boiling in the test section. The measurements showed that the boiling curve changes significantly at higher mass velocities with respect to both the circumferential and axial directions. The slope of the boiling curve changes in a non-monotonic fashion with respect to the circumferential directions. The slope of the boiling curve changes in a non-monotonic fashion with respect to the circumferential direction. The measurements point to the existence of a dry-out phenomenon occurring at multiple levels of the applied heat for the single-side heated channel. In comparing the heat transfer for horizontal channel flow with a vertically downward flow, the results show that significantly lower heat transfer occurs in the horizontal flow. However, this trend reverses as both the Reynolds number and the applied heat rate increase. Both the Liu-Winterton and Shah correlations were compared with the experimental data. The Shah correlation predicted the uniformly heated tube data better. When a thermal hydraulic diameter approach was used for the single-side heated case, the data at upstream locations for Z/L less than 0.5 was bounded above by the Liu-Winterton correlation and below by the Shah correlation. At Z/L = 0.5, the Shah correlation bounded the data; and for Z/L greater than 0.5, both correlations overpredicted the data with the Shah correlation being closest to the data. The present results indicate that additional correlational development is needed. In addressing some of the advanced space thermal management objectives concerning accommodating high heat fluxes in non-uniformly heated systems, a large battery of experiments 88 have been completed where local two-dimensional wall temperature variations were measured for both single-phase and two-phase flow in a single-side heated circular tube. As noted above, the results show significant axial and circumferential variations. Accurately accounting for such variations can result in optimized future advanced space, enhanced (high heat flux) thermal management systems.

Boyd, Ronald D.↗

Enhancement of Heat Transfer with Pool and Spray Impingement Boiling on Microporous and Nanowire Surface Coatings

The DOE National Renewable Energy Laboratory (NREL) is leading a national effort to develop next-generation cooling technologies for hybrid vehicle electronics. The goal is to reduce the size, weight, and cost of power electronic modules that convert direct current from batteries to alternating current for the motor, and vice versa. Aggressive thermal management techniques help to increase power density and reduce weight and volume, while keeping chip temperatures within acceptable limits. The viability of aggressive cooling schemes such as spray and jet impingement in conjunction with enhanced surfaces is being explored. Here, we present results from a series of experiments with pool and spray boiling on enhanced surfaces, such as a microporous layer of copper and copper nanowires, using HFE-7100 as the working fluid. Spray impingement on the microporous coated surface showed an enhancement of 100%-300% in the heat transfer coefficient at a given wall superheat with respect to spray impingement on a plain surface under similar operating conditions. Critical heat flux also increased by 7%-20%, depending on flow rates.

25 ENERGY STORAGE↗

Thermal effects in two-phase flow through face seals

When liquid is sealed at high temperature, it flashes inside the seal due to pressure drop and/or viscous heat dissipation. Two-phase seals generally exhibit more erratic behavior than their single phase counterparts. Thermal effects, which are often neglected in single phase seal analyses, play an important role in determining seal behavior under two-phase operation. It is necessary to consider the heat generation due to viscous shear, conduction into the seal rings and convection with the leakage flow. Analytical models developed work reasonably well at the two extremes - for low leakage rates when convection is neglected and for higher leakage rates when conduction is neglected. A preliminary model, known as the Film Coefficient Model, is presented which considers conduction and convection both, and allows continuous boiling over an extended region unlike the previous low-leakage rate model which neglects convection and always forces a discrete boiling interface. Another simplified, semi-analytical model, based on the assumption of isothermal conditions along the seal interafce, has been developed for low leakage rates. The Film Coefficient Model may be used for more accurate and realistic description.

Basu, Prithwish↗