Search NASA⌕ Search

SEARCH · Search NASA

Results for “uniform method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

A TRACER METHOD FOR COMPUTING TYPE IA SUPERNOVA YIELDS: BURNING MODEL CALIBRATION, RECONSTRUCTION OF THICKENED FLAMES, AND VERIFICATION FOR PLANAR DETONATIONS

We refine our previously introduced parameterized model for explosive carbon–oxygen fusion during thermonuclear Type Ia supernovae (SNe Ia) by adding corrections to post-processing of recorded Lagrangian fluid-element histories to obtain more accurate isotopic yields. Deflagration and detonation products are verified for propagation in a medium of uniform density. A new method is introduced for reconstructing the temperature–density history within the artificially thick model deflagration front. We obtain better than 5% consistency between the electron capture computed by the burning model and yields from post-processing. For detonations, we compare to a benchmark calculation of the structure of driven steady-state planar detonations performed with a large nuclear reaction network and error-controlled integration. We verify that, for steady-state planar detonations down to a density of 5 × 10{sup 6} g cm{sup −3}, our post-processing matches the major abundances in the benchmark solution typically to better than 10% for times greater than 0.01 s after the passage of the shock front. As a test case to demonstrate the method, presented here with post-processing for the first time, we perform a two-dimensional simulation of a SN Ia in the scenario of a Chandrasekhar-mass deflagration–detonation transition (DDT). We find that reconstruction of deflagration tracks leads to slightly more complete silicon burning than without reconstruction. The resulting abundance structure of the ejecta is consistent with inferences from spectroscopic studies of observed SNe Ia. We confirm the absence of a central region of stable Fe-group material for the multi-dimensional DDT scenario. Detailed isotopic yields are tabulated and change only modestly when using deflagration reconstruction.

79 ASTRONOMY AND ASTROPHYSICS↗

Formation of Kinetically Trapped Nanoscopic Unilamellar Vesicles from Metastable Nanodiscs

Zwitterionic long-chain lipids (e.g., dimyristoyl phosphatidylcholine, DMPC) spontaneously form onion-like, thermodynamically stable structures in aqueous solutions (commonly known as multilamellar vesicles, or MLVs). It has also been reported that the addition of zwitterionic short-chain (i.e., dihexanoyl phosphatidylcholine, DHPC) and charged long-chain (i.e., dimyristoyl phosphatidylglycerol, DMPG) lipids to zwitterionic long-chain lipid solutions results in the formation of unilamellar vesicles (ULVs). Here, we report a kinetic study on lipid mixtures composed of DMPC, DHPC, and DMPG. Two membrane charge densities (i.e., [DMPG]/[DMPC] = 0.01 and 0.001) and two solution salinities (i.e., [NaCl] = 0 and 0.2 M) are investigated. Upon dilution of the high-concentration samples at 50 °C, thermodynamically stable MLVs are formed, in the case of both weakly charged and high salinity solution mixtures, implying that the electrostatic interactions between bilayers are insufficient to cause MLVs to unbind. Importantly, in the case of these samples small angle neutron scattering (SANS) data show that, initially, nanodiscs (also known as bicelles) or bilayered ribbons form at low temperatures (i.e., 10 °C), but transform into uniform size, nanoscopic ULVs after incubation at 10 °C for 20 h, indicating that the nanodisc is a metastable structure. The instability of nanodiscs may be attributed to low membrane rigidity due to a reduced charge density and high salinity. Moreover, the uniform-sized ULVs persist even after being heated to 50 °C, where thermodynamically stable MLVs are observed. This result clearly demonstrates that these ULVs are kinetically trapped, and that the mechanical properties (e.g., bending rigidity) of 10 C nanodiscs favor the formation of nanoscopic ULVs over that of MLVs. From a practical point of view, this method of forming uniform-sized ULVs may lend itself to their mass production, thus making them economically feasible for medical applications that depend on monodisperse lipid-based systems for therapeutic and diagnostic purposes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SU-F-E-03: PET/CT Guided Dose Boost to Hypoxic Sub-Volume in Nasopharyngeal Carcinomas Using Self-Optimizing Non-Uniform VMAT

Purpose: This study is to evaluate the feasibility of simultaneously integrated boost (SIB) to hypoxic subvolume (HTV) in nasopharyngeal carcinomas under the guidance of 18F-Fluoromisonidazole (FMISO) PET/CT using a novel non-uniform volumetric modulated arc therapy (VMAT)technique. Methods: Eight nasopharyngeal carcinoma patients treated with conventional uniform VMAT were retrospectively analyzed. For each treatment, actual conventional uniform VMAT plan with two or more arcs (2–2.5 arcs, totally rotating angle < 1000o) was designed with dose boost to hopxic subvolume (total dose, 84Gy) in the gross tumor volme (GTV) under the guidance of 18F- FMISO PET/CT. Based on the same dataset, experimental single arc non-uniform VAMT plans were generated with the same dose prescription using customized software tools. Dosimetric parameters, quality assurance and the efficiency of the treatment delivery were compared between the uniform and non-uniform VMAT plans. Results: To develop the non-uniform VMAT technique, a specific optimization model was successfully established. Both techniques generate high-quality plans with pass rate (>98%) with the 3mm, 3% criterion. HTV received dose of 84.1±0.75Gy and 84.1±1.2Gy from uniform and non-uniform VMAT plans, respectively. In terms of target coverage and dose homogeneity, there was no significant statistical difference between actual and experimental plans for each case. However, for critical organs at risk (OAR), including the parotids, oral cavity and larynx, dosimetric difference was significant with better dose sparing form experimental plans. Regarding plan implementation efficiency, the average machine time was 3.5 minutes for the actual VMAT plans and 3.7 minutes for the experimental nonuniform VMAT plans (p>0.050). Conclusion: Compared to conventional VMAT technique, the proposed non-uniform VMAT technique has the potential to produce efficient and safe treatment plans, especially in cases with complicated anatomical structures and demanding dose boost to subvolumes.

60 APPLIED LIFE SCIENCES↗

Real-time fast inverse dose optimization for image guided adaptive radiation therapy-Enhancements to fast inverse dose optimization (FIDO)

A fast, accurate and stable optimization algorithm is very important for inverse planning of intensity-modulated radiation therapy (IMRT), and for implementing dose-adaptive radiotherapy in the future. Conventional numerical search algorithms with positive beam weight constraints generally require numerous iterations and may produce suboptimal dose results due to trapping in local minima regions of the objective function landscape. A direct solution of the inverse problem using conventional quadratic objective functions without positive beam constraints is more efficient but it will result in unrealistic negative beam weights. We review here a direct solution of the inverse problem that is efficient and does not yield unphysical negative beam weights. In fast inverse dose optimization (FIDO) method the objective function for the optimization of a large number of beamlets is reformulated such that the optimization problem is reducible to a linear set of equations. The optimal set of intensities is then found through a matrix inversion, and negative beamlet intensities are avoided without the need for externally imposed ad hoc conditions. In its original version [S. P. Goldman, J. Z. Chen, and J. J. Battista, in Proceedings of the XIVth International Conference on the Use of Computers in Radiation Therapy, 2004, pp. 112-115; S. P. Goldman, J. Z. Chen, and J. J. Battista, Med. Phys. 32, 3007 (2005)], FIDO was tested on single two-dimensional computed tomography (CT) slices with sharp KERMA beams without scatter, in order to establish a proof of concept which demonstrated that FIDO could be a viable method for the optimization of cancer treatment plans. In this paper we introduce the latest advancements in FIDO that now include not only its application to three-dimensional volumes irradiated by beams with full scatter but include as well a complete implementation of clinical dose-volume constraints including maximum and minimum dose as well as equivalent uniform dose constraints. The method has been integrated into a commercial treatment planning system (Pinnacle, Philips Medical Systems) for beta testing using clinical radiotherapy cases and standard dose constraints set by radiation oncologists. Our FIDO method consistently delivered excellent treatment plans comparable and often better than those obtained using standard optimization techniques that are considerably slower. By design, FIDO is guaranteed to find a global minimum and will achieve highly conformal and homogeneous dose distributions without the need for artificial internal contours that must be created in conventional IMRT optimization systems to help the search engines better control some beam entry directions and in this way avoid the creation of hot and cold spots. This method provides a fast, intuitive and robust technique that yields excellent results for the inverse planning of IMRT. FIDO's ability to efficiently optimize very large numbers of beamlet weights also makes it an ideal tool for the optimization of helical tomotherapy. Future gains in speed will make it possible to use FIDO for instant treatment plan reoptimization using CT images produced at the radiotherapy machine, just prior to daily treatments of the patient.

61 RADIATION PROTECTION AND DOSIMETRY↗

Study of preparation of TiB{sub 2} by TiC in Al melts

TiB{sub 2} particles are prepared by TiC in Al melts and the characteristics of them are studied. It is found that TiC particles are unstable when boron exists in Al melts with high temperature and will transform to TiB{sub 2} and Al{sub 4}C{sub 3}. Most of the synthesized TiB{sub 2} particles are regular hexagonal prisms with submicron size. The diameter of the undersurfaces of these prisms is ranging from 200 nm to 1 {mu}m and the height is ranging from 100 nm to 300 nm. It is considered that controlling the transformation from TiC to TiB{sub 2} is an effective method to prepare small and uniform TiB{sub 2} particles. - Highlights: Black-Right-Pointing-Pointer TiC can easily transform into TiB{sub 2} in Al melts. Black-Right-Pointing-Pointer TiB{sub 2} formed by TiC will grow into regular hexagonal prisms with submicron size. Black-Right-Pointing-Pointer Controlling the transformation from TiC to TiB{sub 2} is an effective method to prepare small and uniform TiB{sub 2} particles.

36 MATERIALS SCIENCE↗

Beam Uniformity Controllable Ion Source with a Long Slit

With scaling up of a substrate of LCD and silicon, an ion source with a longer extraction area than the substrate has been used for an ion implantation system. Wide sheet beam emitted from a long extraction area is effective to decrease space charge effect of a high current ion beam. An ion source which has this structure has been applied for FPD. This ion source controls the source plasma partially. This function is one of the methods to adjust the uniformity of the ion sheet beam. However, there are technical difficulties for this ion source. Therefore, we have developed three types of ion sources which have a longer extracting slit than the substrate and different direction of the source magnetic field. This paper shows the structures and the experimental result of these ion sources.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Tracking discontinuities in parameter space

We develop a geometric framework in Feynman-parameter space to determine constraints on the sequential discontinuities of Feynman integrals. Our method is based on tracking the deformation of the integration contour as external kinematics are analytically continued. This procedure imposes powerful constraints on the analytic structure of Feynman integrals, providing crucial inputs for their bootstrap. We demonstrate the usefulness of this framework by applying it to integrals in dimensional regularization, with higher propagator powers, and to examples with non-uniform transcendental weight. The method is illustrated with several one- and two-loop calculations.

Differential and Algebraic Geometry↗

Large-scale uniform ZnO tetrapods on catalyst free glass substrate by thermal evaporation method

Highlights: • Investigate the growth of ZnO-Ts on glass substrate by thermal evaporation method. • Glass substrate without any catalyst or a seed layer. • The morphology was controlled by adjusting the temperature of the material and the substrate. • Glass substrate was placed vertically in the quartz tube. - Abstract: Here, we report for the first time the catalyst-free growth of large-scale uniform shape and size ZnO tetrapods on a glass substrate via thermal evaporation method. Three-dimensional networks of ZnO tetrapods have needle–wire junctions, an average leg length of 2.1–2.6 μm, and a diameter of 35–240 nm. The morphology and structure of ZnO tetrapods were investigated by controlling the preparation temperature of each of the Zn powder and the glass substrate under O{sub 2} and Ar gases. Studies were carried out on ZnO tetrapods using X-ray diffraction, field emission scanning electron microscopy, UV–vis spectrophotometer, and a photoluminescence. The results showed that the sample grow in the hexagonal wurtzite structure with preferentially oriented along (002) direction, good crystallinity and high transmittance. The band gap value is about 3.27 eV. Photoluminescence spectrum exhibits a very sharp peak at 378 nm and a weak broad green emission.

36 MATERIALS SCIENCE↗

Phase-based velocity extraction method for photonic Doppler velocimetry with potential higher time resolution

We present an extension of the [Takeda et al., J. Opt. Soc. Am. 72, 156 (1982)] phase extraction method to heterodyne photonic Doppler velocimetry applications. The method yields results equivalent to those obtained by the short-time Fourier transform (STFT), while offering potential improvements in time resolution. Unlike STFT, which relies on window functions, such as the Hamming window, that emphasize central data points and diminish the influence of edges, the extended Takeda method utilizes all data uniformly. This uniform treatment allows for the derivation of empirical equations that directly relate velocity error to the actual time resolution rather than to the local analysis duration. The established equation provides a useful metric for both optimizing hardware configuration and guiding data analysis. Simulation and experimental results confirm that, for a given dataset, specifying a target time resolution yields consistent velocity errors for both methods. These findings underscore the Takeda method’s advantages, particularly its potential higher time resolution and reduced computational burden, making it a valuable tool for high-throughput applications such as laser dynamic compression experiments.

Computer simulation↗

Global existence and uniform stabilization of a generalized dissipative Klein-Gordon equation type with boundary damping

In this paper, we prove the existence, uniqueness, and uniform stability of strong and weak solutions of the nonlinear generalized Klein-Gordon equation (1.1){sub 1} (see Sec. I) in bounded domains with nonlinear damped boundary conditions given by (1.1){sub 3} (see Sec. I) with some restrictions on function f(u), h({nabla}u), g(u{sub t}), and b(x), we prove the existence and uniqueness by means of nonlinear semigroup method and obtain the uniform stabilization by using the multiplier technique.

97 MATHEMATICS AND COMPUTING↗

Homological Invariants of Pauli Stabilizer Codes

Abstract We study translationally invariant Pauli stabilizer codes with qudits of arbitrary, not necessarily uniform, dimensions. Using homological methods, we define a series of invariants called charge modules. We describe their properties and physical meaning. The most complete results are obtained for codes whose charge modules have Krull dimension zero. This condition is interpreted as mobility of excitations. We show that it is always satisfied for translation invariant 2D codes with unique ground state in infinite volume, which was previously known only in the case of uniform, prime qudit dimension. For codes all of whose excitations are mobile we construct a p-dimensional excitation and a $$(D-p-1)$$ ( D - p - 1 ) -form symmetry for every element of thep-th charge module. Moreover, we define a braiding pairing between charge modules in complementary degrees. We discuss examples which illustrate how charge modules and braiding can be computed in practice.

Physics↗

A Weak Galerkin Method for the Reissner–Mindlin Plate in Primary Form

We developed a new finite element method for the Reissner–Mindlin equations in its primary form by using the weak Galerkin approach. Like other weak Galerkin finite element methods, this one is highly flexible and robust by allowing the use of discontinuous approximating functions on arbitrary shape of polygons and, at the same time, is parameter independent on its stability and convergence. Furthermore, error estimates of optimal order in mesh size h are established for the corresponding weak Galerkin approximations. Numerical experiments are conducted for verifying the convergence theory, as well as suggesting some superconvergence and a uniform convergence of the method with respect to the plate thickness.

97 MATHEMATICS AND COMPUTING↗

Solvent-Free Melt-Processed Cathode Mitigates Li Anode Instability in Polymer-Based Solid-State Batteries

Solvent-free manufacturing of battery components is a promising alternative to traditional slurry processing for reducing the cost and environmental impact. In this work, we used twin-screw melt extrusion to fabricate a polymer-based high voltage composite cathode. The melt-processed cathode is dense (near zero porosity) and thick (65 μm) and has high active material loading (80 wt %). The active particles are distributed uniformly throughout the melt-processed cathode, unlike the traditional slurry-cast cathode, which exhibits inhomogeneous particle distribution. In the melt-processed cathode, polymer and carbon form separate phases, whereas in the slurry-cast cathode they blend into a single phase. Due to these structural differences, the melt-processed cathode shows smooth charge–discharge profiles, while the slurry-cast cathode shows noisy charging and soft-shorting behavior. In conclusion, this work highlights that twin-screw extrusion as a scalable, solvent-free manufacturing method is advantageous in producing uniform cathodes, which mitigates anode instability.

25 ENERGY STORAGE↗

Distribution System Segmented Model Simplification with Independent Dynamically Changing End-Use Loads

With more emerging technologies in power distribution systems, to support quasi-static time-series (QSTS) simulation over short time frames, accurately modeling the dynamic behavior of end-use load under various conditions is im- portant. However, time and cost can be a burden for the QSTS simulation of thousands of houses representing dynamic load behaviors on large distribution feeders. There are two main contributions of this paper in order to reduce the QSTS simulation complexity. First, the paper presents a method to stochasti- cally model the dynamic behavior of end-use load for QSTS simulations. Second, using the stochastically modeled load behavior as an input to a distribution sys- tem, and building on our previous QSTS simulation simplification/acceleration method that relies on uniform load behavior, this paper presents a segment substitution approach for the simplification of distribution system models with independent dynamically changing end-use loads. Our numerical results show that compared to GridLAB-D, a software tool that simulates end-use load be- havior through physical models, the proposed stochastic modeling approach achieved an 89.3% simulation time reduction for end-use loads, while accurately capturing the temporally changing total load behavior. Moreover, the QSTS simulation of a large test distribution system through OpenDSS showed that the proposed simplification method decreased the feeder simulation time by a factor of three at less than 0.3% voltage error. Compared to our previous method with independent dynamic loads, the voltage error is reduced by a factor of four.

Power distribution system modeling, stochastic pro↗

Characterizing the marker-dye correction for Gafchromic EBT2 film: A comparison of three analysis methods

Purpose: Gafchromic EBT2 film has a yellow marker dye incorporated into the active layer of the film that can be used to correct the film response for small variations in thickness. This work characterizes the effect of the marker-dye correction on the uniformity and uncertainty of dose measurements with EBT2 film. The effect of variations in time postexposure on the uniformity of EBT2 is also investigated. Methods: EBT2 films were used to measure the flatness of a {sup 60}Co field to provide a high-spatial resolution evaluation of the film uniformity. As a reference, the flatness of the {sup 60}Co field was also measured with Kodak EDR2 films. The EBT2 films were digitized with a flatbed document scanner 24, 48, and 72 h postexposure, and the images were analyzed using three methods: (1) the manufacturer-recommended marker-dye correction, (2) an in-house marker-dye correction, and (3) a net optical density (OD) measurement in the red color channel. The field flatness was calculated from orthogonal profiles through the center of the field using each analysis method, and the results were compared with the EDR2 measurements. Uncertainty was propagated through a dose calculation for each analysis method. The change in the measured field flatness for increasing times postexposure was also determined. Results: Both marker-dye correction methods improved the field flatness measured with EBT2 film relative to the net OD method, with a maximum improvement of 1% using the manufacturer-recommended correction. However, the manufacturer-recommended correction also resulted in a dose uncertainty an order of magnitude greater than the other two methods. The in-house marker-dye correction lowered the dose uncertainty relative to the net OD method. The measured field flatness did not exhibit any unidirectional change with increasing time postexposure and showed a maximum change of 0.3%. Conclusions: The marker dye in EBT2 can be used to improve the response uniformity of the film. Depending on the film analysis method used, however, application of a marker-dye correction can improve or degrade the dose uncertainty relative to the net OD method. The uniformity of EBT2 was found to be independent of the time postexposure.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Surface heterogeneity propagation and homogenization for pouch cell-scale Li metal anodes

Li metal anode is a promising candidate for next-generation energy storage systems and is widely explored in Li-ion and solid-state batteries. Despite its potential, Li metal anodes face instabilities during long-term cycling, especially when paired with NMC or sulfur-based cathodes, where Li is cycled at high capacities of 6-8 mAh/cm2, equivalent to a thickness of 30-40 µm. During such extensive utilization, degradation mechanisms such as excessive solid electrolyte interphase (SEI), dendrites, and dead Li emerge, and ultimately lead to sudden failure and reduced cycle life. The origin of the degradation mechanisms stem from surface heterogeneities introduced during Li foil manufacturing and storage [1, 2]. As cycling progresses, the local heterogeneities propagate, resulting in uneven Li utilization and degradation-prone regions across the electrode [3], which consequently induce performance variations at the cell level. This heterogeneity propagation is particularly pronounced in large-format pouch cells in practical applications, where the surface effects are magnified. Without a clear understanding of the multi-scale heterogeneities and the development of surface homogenization methods, the performance consistency will be compromised, hindering the commercialization of Li metal batteries. In this presentation, we investigate the evolution of surface heterogeneity propagation on commercially available Li foils. We discover that inhomogeneous Li utilization appears as early as the first half-cycle of formation, manifesting as localized clusters and pits. In pouch cell configurations, these features exhibit areal density variations across the electrode on a scale of millimeters. To improve Li utilization homogeneity, a scalable mechanical brushing method is introduced to remove the chemically heterogeneous surface passivation layer. Furtherore, the influence of utilization homogeneity on cell-to-cell consistency is evaluated using 32 Li-NMC811 pouch cells divided into as-received and brushed Li groups. On the brushed Li, clusters and pits are no longer observable, and the cells exhibit significantly improved consistency in discharge capacity trajectories and cycle lifetime. Overall, this study highlights the role of Li surface utilization homogeneity on long-term cycling performance. Our research provides a pathway for improving large-area electrode uniformity and establishing evaluation methods for cell-to-cell consistency, both are key steps toward the commercialization of Li metal batteries and beyond. [1] Otto, Svenja-K., et al. "In-depth characterization of lithium-metal surfaces with XPS and ToF-SIMS: toward better understanding of the passivation layer." Chemistry of Materials 33.3 (2021): 859-867. [2] Hatzell, Kelsey, et al. "Aligning lithium metal battery research and development across academia and industry." Joule (2024). [3] Kim, Sangwook, et al. "Calendar life of lithium metal batteries: Accelerated aging and failure analysis." Energy Storage Materials 65 (2024): 103147.

25 - ENERGY STORAGE↗

SU-F-T-578: Characterization of Vidar DosimetryPro Advantage RED Scanner with Application to SBRT and SRS QA

Purpose: To use Gafchromic EBT3 film to quantify key dosimetric characteristics of the Vidar DosimetryPro Advantage RED film scanner for use in SBRT/SRS QA, by analyzing scanner uniformity and dose sensitivity. Method: Gafchromic EBT3 film was used in this study. Films were irradiated using 6MV FFF and 10MV FFF beams from a Varian Edge linear accelerator, with setup of 100cm SAD at depth 5 cm. Nine doses were delivered per film, with calibration dose ranges of 1–10 Gy and 3–24 Gy for 6MV FFF, and 3–27 Gy for 10MV FFF. Films were scanned with the long side of the film parallel to the detector array. Dose calibration curves were fitted to a 3rd degree polynomial. The derivative of a calibration curve was taken to determine the scanner’s sensitivity per dose delivered (OD/Gy). Scanner non-uniformity was calculated in 2 dimensions by taking the mean of standard deviation in each row and column. Absolute dose SRS/SBRT Gamma analyses were performed with passing criteria of 3% and 1mm DTA. For comparison, Gamma analyses were also performed using an Epson Expression 10000 XL. Results: Uniformity for the Vidar scanner was 0.37% +/− 0.03% in the perpendicular to scan direction and 0.67% +/− 0.05% in the parallel to scan direction, with an overall uniformity of 0.52% +/− 0.03%. Epson red channel uniformity was 0.85% +/− 0.05% and 0.88% +/− 0.08% for the green channel. The Vidar average dose sensitivity from 1–10 Gy was 0.112 OD/Gy and 0.061 OD/Gy for 3–24 Gy. SBRT/SRS Gamma pass rates were 97.8 +/− 1.4 for Vidar and 97.5 +/− 1.4 for Epson. Conclusion: The Vidar scanner has 41% less non-uniformity compared to Epson XL10000 green channel. The dose sensitivity is 2–3 time greater for the Vidar scanner compared to the Epson in the SRS/SBRT dose range of 5–24 Gy.

60 APPLIED LIFE SCIENCES↗

Use of a Heat Flow Meter to Determine Active PCM Content in an Insulation

Residential and commercial roofs and walls are currently designed and tested using steady-state criteria. The resulting R-values, based on the apparent thermal conductivity, are used by building standards as an important measure of energy performance. Building envelope components, however, are subject to dynamic environmental conditions. This mismatch between the steady-state principles used in design and code requirements and their dynamic operation results in relatively low thermal efficiencies. Although several research centers have developed experimental methods for transient analysis of building envelopes, there are no standardized testing procedures available for screening materials and systems for which performance depends on dynamic response. For example, a full-scale dynamic evaluation of phase change materials (PCMs) is needed to assess their energy saving benefits. A nationally accepted small-scale (one to two foot size specimens) testing procedure is not available for the analysis of dynamic thermal characteristics of conventional thermal mass systems or PCM-enhanced materials. At the same time, data on these characteristics are necessary for whole-building simulations, energy analysis, and energy code work. The transient characteristics of PCM-enhanced products depend on the PCM content and quality. The only readily available method of thermal evaluation uses the differential scanning calorimeter. Unfortunately, this method requires small, relatively uniform test specimens. This requirement is unrealistic in the case of PCM-enhanced building envelope products such as PCM-cellulose, PCM-glass fiber, or PCM-gypsum blends. Small specimens are not representative of PCM-based blends, since these materials are not homogeneous. Jan Kosny and David Yarbrough, Oak Ridge National Laboratory, P.O. Box 2008, MS 6070, Oak Ridge, TN 37831-6070. Elizabeth Kossecka, Polish Academy of Sciences, Institute of Fundamental Technological Research, Pawinskiego 5 B, 02-106, Warsaw, Poland. A procedure for making dynamic heat-flow measurements using existing instrumentation has been developed to analyze the benefits of thermal storage. This small-scale testing method is useful for thermal analysis and as a potential quality control method for producers of PCM-enhanced building materials. The research may provide the basis for consensus standard development. This paper uses as an example a dynamic testing process for PCM-enhanced cellulose insulation.

25 ENERGY STORAGE↗