Search NASA⌕ Search

SEARCH · Search NASA

Results for “voltage profile”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Gunn threshold voltage characterization in GaAs devices with wedge-shaped tapering

Here, we fabricate gallium arsenide-based devices with a wedge-shaped tapering region connected to a rectangular-shaped region and measure the threshold voltage required to trigger the Gunn effect. The threshold voltage reduction is attributed to the focusing of the electric field toward the narrower end of the device and is effective when the device has a steep enough tapering. We also model the electric field profile for the tapered devices using an intuitive graphical approach and the finite element method and provide estimates for the threshold voltages of tapered devices. Finally, we compare the estimates to the measured values and provide possible reasons for the discrepancies. We believe the capability of threshold voltage reduction with the wedge-shaped tapering design could be useful in device applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Fast, Space qualified 3000 V modulator for a Cloud Profiling Radar

This paper describes the design approach for the FEM and its performance in EM and Flight configurations. This design is a simple but universal approach which allows the designers to greater flexibility and freedom in designing high swinging voltage space- qualifiable FEM.

CloudSat↗

Local spring effect in titanium-based layered oxides

Titanium-based layered oxides (TLOs) are one of the most promising electrode material families for sodium-ion batteries (NIBs) due to their smooth charge/discharge profiles and excellent cycle performance. However, the reaction mechanism of these materials, especially the reason for the disappearance of multiple voltage plateaus, is still not clear. Herein, two representative TLOs (Na 2/3 Ni 1/3 Ti 2/3 O 2 and Na 2/3 Co 1/3 Ti 2/3 O 2 ) with the same P2 crystal structure have been studied to scrutinize those unexplained issues. In situ synchrotron high-energy X-ray diffraction revealed a solid solution reaction mechanism for both, suggesting the absence of rigid phase transitions upon electrochemical cycling. An interesting “spring effect” of the TiO 6 octahedron, i.e., the reversible vibration of the central Ti atom inside the local octahedron upon electrochemical redox, was demonstrated by advanced X-ray absorption spectroscopy and theoretical calculations. Such an effect could suppress the rigid phase transitions, and result in smooth charge/discharge profiles and enhanced cycle stability. Finally, this work not only accounts for the disappearance of multiple voltage plateaus of TLOs for NIBs, but also provides an effective local-structure viewpoint to increase the cycle stability of electrode materials for other advanced battery systems.

25 ENERGY STORAGE↗

Negligible voltage hysteresis with strong anionic redox in conventional battery electrode

Lattice anionic (oxygen) redox reactions (ARR) offers opportunities for developing high-capacity batteries, however, often suffers the notoriously high hysteresis in voltages and low initial coulombic efficiency. Particularly, ARR was widely considered inherent to these kinetic issues. Here, unambiguous evidences of strong and reversible ARR is found in Na 2/3 Ni 1/3 Mn 2/3 O 2 through mapping of resonant inelastic X-ray scattering (mRIXS). Strikingly, the material displays negligible voltage hysteresis (0.1 V) and high initial coulombic efficiency with a highly stable electrochemical profile. Our independent analysis of the Ni, Mn and O states consistently interpret the redox mechanism of Na 2/3 Ni 1/3 Mn 2/3 O 2 , which reveals a strong ARR system with facile kinetics and highly stable electrochemical profile that previously found only in cationic redox systems of conventional non-Alkali-rich materials.

25 ENERGY STORAGE↗

A 75 kVA Intelligent Power Stages (IPS) Unit Design for Future Grid-interface Application

The demand for grid-interface converter with flexible dc bus is driven by the fast development of energy storage system (ESS), electric vehicle (EV) charging system, and versatile residential load. This paper first proposes a two-stage intelligent power stage (IPS) unit for future grid-interface applications. To achieve zero common-mode (CM) voltage emissions, step-up and step-down voltage gain, a 3-level four-switch buck-boost (3-L FSBB) dc-dc converter is adopted with fully zero voltage switching (ZVS). In one IPS unit, an advanced fiberoptic communication with sub-nanosecond synchronization is developed for different enhanced gate drivers. Moreover, an enhanced gate driver integrated current and voltage sensors is designed for monitoring and diagnostics. To achieve a whole low-profile design, three 12 oz heavy copper planar ac inductors are designed and implemented. Finally, a 75 kVA IPS unit was built to verify both the thermal and electrical design.

Cao, Yuliang↗

Statistical Profiles of E1 EMP Coupling to Single Conductors

An electro-magnetic pulse (EMP) event can induce large currents and voltages on electrical conductors such as electrical power transmission lines which span many kilometers and the shorter lines typically tens of meters in length used to monitor equipment controlling the power grid. The exact current and voltage induced on a conductor depends on many factors, such as line height, diameter and length as well as ground conductivity and the location of the EMP event relative to the conductor. The current work focus on the line location and orientation relative to the EMP source. A statistical, Monte-Carlo approach is used in sampling the line configuration and then calculating the induced current and voltage. Thousands of EMP events are simulated on the region of the Earth where the EMP event can couple to a given above-ground conductor and the resulting current and voltage is then calculated on that conductor. Through the many simulations, one can assemble statistics on the insult including the peak value, rise time and pulse width.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Experimental investigation of a wall stablized arc with comparisons to theoretical predictions

A wall-stabilized, constricted-arc heater was investigated by extensive measurements of pressure, voltage, and wall heat flux at different axial locations along the constrictor. Radial temperature profiles were measured at one axial location by the radiance of a single line method and also by the continuum radiance at a wavelength of 4955 A. The arc heater with an inside diameter of 2.37 cm and a constrictor length of 42 cm was operated with nitrogen flow rate from about 2 to 10 g/sec, and are currents from 400 to 1200 amperes. Based on a literature search, two different digital computer programs were selected which were used to predict the pertinent parameters by numerical solutions to the governing differential equations. The program selections were based on completeness and availability. In general the predictions were adequate when laminar flow was assumed, and the greatest difficulty was encountered in the predictions of wall heat flux. The results of the measurements are shown in graphical form, along with the theoretical predictions from both computer programs.

Wells, W. L.↗

Design and fabrication of a four-rod radio frequency quadrupole with a variable aperture

Radiofrequency quadrupole (RFQ) linear accelerators with variable aperture cell parameters offer an effective means of accelerating high-intensity ion beams exceeding 100 mA and have been implemented in various RFQ designs. However, in a four-rod RFQ, the use of dielectric perturbation methods to measure the voltage distribution behind the rod electrodes is not applicable when implementing variable aperture geometries, because changes in the rod shape influence the electric field at the location of the perturbation element. Therefore, it was necessary to design the rod profile for each cell such that the electric field distribution behind the rods remains unaffected by changes in the aperture. In this study, we present a method to adjust the voltage distribution by modifying the geometry of the rod electrodes according to each cell's aperture parameters. This design approach enables the integration of variable aperture cells into a four-rod RFQ linac, significantly enhancing the achievable beam current. To ensure uniform capacitance and maintain a constant rod-electrode voltage despite variations in the average aperture radius, we developed a systematic method for shaping the rod electrodes. This method was refined using two-dimensional (2D) and three-dimensional (3D) electromagnetic field simulations to optimize the electrode cross-sectional profiles. The fabricated rod electrodes were then installed in a four-rod RFQ, and the electric field distribution was measured using the perturbation method and tuned by adjusting the base plates. As a result, the measured variation of ±1.1 % confirms that this design methodology can produce a sufficiently uniform voltage distribution for high-current beam acceleration. These results demonstrate the practical feasibility of a variable-aperture four-rod RFQ linac.

43 PARTICLE ACCELERATORS↗

Thermocouple Rakes for Measuring Boundary Layer Flows Extremely Close to Surface

Of vital interest to aerodynamic researchers is precise knowledge of the flow velocity profile next to the surface. This information is needed for turbulence model development and the calculation of viscous shear force. Though many instruments can determine the flow velocity profile near the surface, none of them can make measurements closer than approximately 0.01 in. from the surface. The thermocouple boundary-layer rake can measure much closer to the surface than conventional instruments can, such as a total pressure boundary layer rake, hot wire, or hot film. By embedding the sensors (thermocouples) in the region where the velocity is equivalent to the velocity ahead of a constant thickness strut, the boundary-layer flow profile can be obtained. The present device fabricated at the NASA Glenn Research Center microsystem clean room has a heater made of platinum and thermocouples made of platinum and gold. Equal numbers of thermocouples are placed both upstream and downstream of the heater, so that the voltage generated by each pair at the same distance from the surface is indicative of the difference in temperature between the upstream and downstream thermocouple locations. This voltage differential is a function of the flow velocity, and like the conventional total pressure rake, it can provide the velocity profile. In order to measure flow extremely close to the surface, the strut is made of fused quartz with extremely low heat conductivity. A large size thermocouple boundary layer rake is shown in the following photo. The latest medium size sensors already provide smooth velocity profiles well into the boundary layer, as close as 0.0025 in. from the surface. This is about 4 times closer to the surface than the previously used total pressure rakes. This device also has the advantage of providing the flow profile of separated flow and also it is possible to measure simultaneous turbulence levels within the boundary layer.

Hwang, Danny P.↗

Optimal Charging of Nickel-Hydrogen Batteries for Life Extension

We are exploring the possibility of extending the cycle life of battery systems by using a charging profile that minimizes cell damage. Only nickel-hydrogen cells are discussed at this time, but applications to lithium-ion cells are being considered. The process first requires the development of a fractional calculus based nonlinear dynamic model of the specific cells being used. The parameters of this model are determined from the cell transient responses. To extend cell cycle life, an instantaneous damage rate model is developed. The model is based on cycle life data and is highly dependent on cell voltage. Once both the cell dynamic model and the instantaneous damage rate model have been determined, the charging profile for a specific cell is determined by numerical optimization. Results concerning the percentage life extension for different charging strategies are presented. The overall procedure is readily adaptable to real-time implementations where the charging profile can maintain its minimum damage nature as the specific cell ages.

Hartley, Tom T.↗

Characterization of Downstream Ion Energy Distributions From a High Current Hollow Cathode in a Ring Cusp Discharge Chamber

The presence of energetic ions produced by a hollow cathodes operating at high emission currents (greater than 10 Angstroms) has been documented in the literature. As part of an ongoing effort to uncover the underlying physics of the formation of these ions, ion efflux from a high current hollow cathode operating in an ion thruster discharge chamber was investigated. Using a spherical sector electrostatic energy analyzer located downstream of the discharge cathode, the ion energy distribution over a 0 to 60 eV energy range was measured. The sensitivity of the ion energy distribution function to zenith angle was also assessed at 3 different positions: 0, 15, and 25 degrees. The measurements suggest that the majority of the ion current at the measuring point falls into the analyzer with an energy approximately equal to the discharge voltage. The ion distribution, however, was found to be quite broad. The high energy tail of the distribution function tended to grow with increasing discharge current. Sensitivity of the profiles to flow rate at fixed discharge current was also investigated. A simple model is presented that provides a potential mechanism for the production of ions with energies above the discharge voltage.

Foster, John E.↗

Public Reference Data for Megawatt-Scale Hydrogen Electrolysis - NLR Historical Solar PV

The U.S. Department of Energy and National Laboratory of the Rockies (NLR) demonstrate hydrogen electrolysis from variable sources, hydrogen compression and storage, and hydrogen fuel cell power production using megawatt-scale equipment at NLR’s Flatirons Campus as part of the Advanced Research on Integrated Energy Systems (ARIES) research platform. This dataset represents part of that effort and is intended for academic, national laboratory, industrial, and other stakeholders to plan, design, and validate models of megawatt-scale hydrogen technologies and diverse energy infrastructure nationwide. These data provide a baseline for how existing hydrogen electrolysis technologies perform when coupled with various energy technologies. Future datasets will demonstrate how existing hydrogen fuel cell technologies can provide controllable, dispatchable, and variable power output for artificial intelligence data centers and other variable loads. This dataset entry describes the behavior of a 1.25-MW proton exchange membrane MC250 electrolyzer system, manufactured by Nel Hydrogen , [1] when fed historical data generated by the 430-kW, fixed-axis solar photovoltaic (PV) array located at NLR’s Flatirons Campus. (While the electrolyzer balance of plant supports up to 2.5 MW of electrolysis, NLR only has a single 1.25-MW electrolysis stack.) Solar PV power output data for the 2020 calendar year were categorized on a daily basis by total energy generation and standard deviation. Each day was then ranked by these metrics, and the 25th, 50th, and 100th percentiles were selected. The 75th percentile day did not exhibit sufficient variability to make for a valuable experiment. A similar process was used for the related historical wind dataset . [2] The historical days in 2020 that represented these percentiles are Dec. 19, March 29, and May 4, respectively. The entire solar day’s power profile was then fed through the MC250 electrolyzer. Due to its length, the 100th percentile day experiment was split into two parts, and the final 3 hours of the solar day were not captured. These final 3 hours contained no spikes or dips of interest and simply represented a slow decay of input solar power. Also, a single timestamp (13:13:47 on Jan. 14, 2026) was lost in the hydrogen system supervisory control and data acquisition. Finally, during the 25th percentile experiment (solar day Dec. 19, 2020) data recording was lost from 11:00:13 to 11:14:45. The roughly 15 minutes of the solar profile were rerun at the end of the experiment and spliced into this time slot during post-processing. The electrolysis system controls hydrogen production by varying direct current applied to the stack, from a maximum of 3,000 A to a minimum safe operation of 300 A, or 10%. Because the current–voltage characteristic changes as the stack ages and efficiency degrades, the actual minimum safe operating power changes over time. The historical solar profiles were translated from power (kilowatts) to current (amperes) using a curve fit with calibration data and sent to the electrolyzer power supply at 1-Hz frequency. For more details on the statistical analysis process, see the slide deck “Public Reference Data for Megawatt-Scale Hydrogen Electrolysis: NLR Historical Solar PV Analysis and Profile Generation” accessible with this data entry. These datasets report relevant hydrogen balance-of-plant and system data, all captured at 1 Hz, including hydrogen mass production measured with an Emerson Coriolis flow meter. Each .zip file represents a single solar PV electrolysis experiment and is formatted as: {technology}_{percentile}_{scaling factor} For instance, “solarPV-430kW_25_2x.zip” reports the experiment using the 25th percentile solar data from the historical 2020 solar PV dataset, scaled to 200%. Scaling factors were applied to the generated solar PV power output files to more closely match the 1.25-MW capacity of the electrolyzer. Each .zip folder contains the following files: A .csv file containing raw data. An .xlsx file explaining all the fields in the raw data. A .png plot showing the time series of hydrogen production, electrolysis power consumption, and solar power input. A PDF file detailing the historical solar data statistical analysis used to generate the solar profile. An experiment labeled “characterization_200.zip” demonstrates the MC250 electrolyzer steady-state response with 30-minute load steps for a total duration of 5 hours. Finally, a .csv file is provided with all experiments combined into one dataset labeled "combined_solarPV_experiments.csv". [1] nelhydrogen.com/product/mc-series-electrolyser . [2] data.nlr.gov/submissions/316 .

08 HYDROGEN↗

Static pressure measurements in A 30 kWe class arcjet

A series of cold and hot flow static pressure measurements have been made as a function of distance along the principal axis of a 30 kWe arcjet. During these experiments, the background pressure was varied from atmospheric pressure to less than 1 Torr. The experimental arcjet used in these tests had the same constrictor and conical nozzle dimensions as the baseline MOD-1 ammonia arcjet developed at NASA-JPL, but used nitrogen as the propellant gas. Comparison of the measured static pressure profiles with the arc erosion patterns on the anode surface showed that anode arc attachment points directly coincided with the minimum static pressure points. The dual voltage modes commonly observed in 30 kWe class arcjet thrusters are also believed to be caused by the presence of two pressure minima in the arcjet, one at the constrictor entrance and the other in the expansion nozzle. The static pressure profiles also suggest that the sonic flow transition occurs at the entrance to the nozzle, indicating the existence of very thick boundary layers in the arcjet constrictor.

Harris, William J.↗

Preliminary study of a wall stabilized constructed arc

An iterative, implicit, finite-difference numerical technique is described which is suitable for obtaining solutions to the governing equations for a gas flowing in an axially symmetric constricted-arc heater. The method is shown to provide adequate solutions for three cases of simple pipe flows found in the literature, and for flow in a constricted-arc heater by direct comparison with experimental data. The comparison with arc-heater data includes static pressure, arc voltage, and wall heat flux, all as a function of axial location, and a radial temperature profile at one axial station. The arc-heater data were taken with air as the test gas at a heater inlet pressure approximately 0.40 atm and two flow rates of 2.2 and 4.8 g/sec. The arc currents investigated were between 377 and 584 amperes.

Graves, R. A.↗

RCA SATCOM in-orbit experience: An update

The SATCOM in-orbit battery performance was evaluated. The capacitance and constant current charge rates for each of the three batteries were monitored. A typical eclipse discharge profile was generated and attendant reconditioning recharge conditions were considered. Battery temperatures, pressures, and average battery voltages are presented in tabular form. In-orbit data from monitoring the end of discharge voltage during eclipses, a key performance parameter, are also given.

Stewart, D.↗

Discharge Chamber Performance of the NEXIS Ion Thruster

The Nuclear-Electric Xenon Ion System (NEXIS) thruster was designed to produce greater than or equal to 70% efficiency at ISPs in excess of 6500 sec and total power levels in excess of 15 kW. In order to achieve this performance, the thruster requires a large area plasma generator capable of high propellant utilimtion efficiency and low discharge loss while producing a very flat, uniform beam profile. Fortunately, larger thrusters can be made more uniform and efficient due to the higher volume to surface ratio, provided that the magnetic cusp confinement is designed properly and the thruster length to diameter ratio is adequate. This paper describes the discharge chamber performance of the NEXIS Laboratory Model (LM) thruster. The LM discharge chamber is 65 cm in diameter at the grid plane and uses 6 ring-cusps to provide magnetic confinement of the plasma. The thruster was tested with flat carbon-carbon composite grids with the hole pattern masked to 57 cm in diameter and a conventional Type-B "1/2" diameter hollow cathode. During the preliminary "discharge only" tests, the LM thruster demonstrated profile factors of 0.84 and a discharge loss of about 160 eV/ion at 25 V discharge voltage and over 90% propellant utilization efficiency in simulated beam extraction experiments at 3.9 A of beam current. Analysis of the data from these tests used the discharge-only model developed by Brophy. Subsequent beam extraction experiments validated the key variables used in the model to predict the performance from the discharge-only data, and demonstrated 3.9 A of beam current at over 90% propellant utilization efficiency with a flatness parameter of better than 0.8 and a discharge loss of about 185 eV/ion. The slightly higher discharge loss measured during beam extractions was found to be due to a lower screen transparency in the as-manufactured LM grid set. Plasma measurements with a scanning probe internal to the thruster near the screen grid showed plasma densities over l x 10(exp 11) per cubic centimeter and electron temperatures of 3.5 to 5.5 eV depending on the operation parameters. The performance of the NEXIS discharge chamber contributed to the over 78% thruster efficiency measured during beam extraction at 7500 sec ISP and 25 kW of power, and over 81% thruster efficiency measured at 8500 sec ISP.

plasma generation↗

Method of Detecting System Function by Measuring Frequency Response

Real time battery impedance spectrum is acquired using one time record, Compensated Synchronous Detection (CSD). This parallel method enables battery diagnostics. The excitation current to a test battery is a sum of equal amplitude sin waves of a few frequencies spread over range of interest. The time profile of this signal has duration that is a few periods of the lowest frequency. The voltage response of the battery, average deleted, is the impedance of the battery in the time domain. Since the excitation frequencies are known, synchronous detection processes the time record and each component, both magnitude and phase, is obtained. For compensation, the components, except the one of interest, are reassembled in the time domain. The resulting signal is subtracted from the original signal and the component of interest is synchronously detected. This process is repeated for each component.

Morrison, John L.↗

What Reliability Engineers Should Know about Space Radiation Effects

Space radiation in space systems present unique failure modes and considerations for reliability engineers. Radiation effects is not a one size fits all field. Threat conditions that must be addressed for a given mission depend on the mission orbital profile, the technologies of parts used in critical functions and on application considerations, such as supply voltages, temperature, duty cycle, and redundancy. In general, the threats that must be addressed are of two types-the cumulative degradation mechanisms of total ionizing dose (TID) and displacement damage (DD). and the prompt responses of components to ionizing particles (protons and heavy ions) falling under the heading of single-event effects. Generally degradation mechanisms behave like wear-out mechanisms on any active components in a system: Total Ionizing Dose (TID) and Displacement Damage: (1) TID affects all active devices over time. Devices can fail either because of parametric shifts that prevent the device from fulfilling its application or due to device failures where the device stops functioning altogether. Since this failure mode varies from part to part and lot to lot, lot qualification testing with sufficient statistics is vital. Displacement damage failures are caused by the displacement of semiconductor atoms from their lattice positions. As with TID, failures can be either parametric or catastrophic, although parametric degradation is more common for displacement damage. Lot testing is critical not just to assure proper device fi.mctionality throughout the mission. It can also suggest remediation strategies when a device fails. This paper will look at these effects on a variety of devices in a variety of applications. This paper will look at these effects on a variety of devices in a variety of applications. (2) On the NEAR mission a functional failure was traced to a PIN diode failure caused by TID induced high leakage currents. NEAR was able to recover from the failure by reversing the current of a nearby Thermal Electric Cooler (turning the TEC into a heater). The elevated temperature caused the PIN diode to anneal and the device to recover. It was by lot qualification testing that NEAR knew the diode would recover when annealed. This paper will look at these effects on a variety of devices in a variety of applications. Single Event Effects (SEE): (1) In contrast to TID and displacement damage, Single Event Effects (SEE) resemble random failures. SEE modes can range from changes in device logic (single-event upset, or SEU). temporary disturbances (single-event transient) to catastrophic effects such as the destructive SEE modes, single-event latchup (SEL). single-event gate rupture (SEGR) and single-event burnout (SEB) (2) The consequences of nondestructive SEE modes such as SEU and SET depend critically on their application--and may range from trivial nuisance errors to catastrophic loss of mission. It is critical not just to ensure that potentially susceptible devices are well characterized for their susceptibility, but also to work with design engineers to understand the implications of each error mode. -For destructive SEE, the predominant risk mitigation strategy is to avoid susceptible parts, or if that is not possible. to avoid conditions under which the part may be susceptible. Destructive SEE mechanisms are often not well understood, and testing is slow and expensive, making rate prediction very challenging. (3) Because the consequences of radiation failure and degradation modes depend so critically on the application as well as the component technology, it is essential that radiation, component. design and system engineers work togetherpreferably starting early in the program to ensure critical applications are addressed in time to optimize the probability of mission success.

DiBari, Rebecca↗