Search NASA⌕ Search

SEARCH · Search NASA

Results for “volume visualization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Performance Optimization and Auto-Tuning

In the broader computational research community, one subject of recent research is the problem of adapting algorithms to make effective use of multi- and many-core processors. Effective use of these architectures, which have complex memory hierarchies with many layers of cache, typically involves a careful examination of how an algorithm moves data through the memory hierarchy. Unfortunately, there is often a non-obvious relationship between algorithmic parameters like blocking strategies, and their impact on memory utilization, and, in turn, the relationship with runtime performance. Auto-tuning is an empirical method used to discover optimal values for tunable algorithmic parameters under such circumstances. The challenge is compounded by the fact that the settings that produce the best performance for a given problem and a given platform may not be the best for a different problem on the same platform, or the same problem on a different platform. The high performance visualization research community has begun to explore and adapt the principles of auto-tuning for the purpose of optimizing codes on modern multi- and many-core processors. This report focuses on how performance optimization studies reveal a dramatic variation in performance for two fundamental visualization algorithms: one based on a stencil operation having structured, uniform memory access, and the other is ray casting volume rendering, which uses unstructured memory access patterns. The two case studies highlighted in this report show the extra effort required to optimize such codes by adjusting the tunable algorithmic parameters can return substantial gains in performance. Additionally, these case studies also explore the potential impact of and the interaction between algorithmic optimizations and tunable algorithmic parameters, along with the potential performance gains resulting from leveraging architecture-specific features.

97 MATHEMATICS AND COMPUTING↗

DynaM: Dynamic Multiresolution Data Representation for Large-Scale Scientific Analysis

Fast growing large-scale systems enable scientific applications to run at a much larger scale and accordingly produce gigantic volumes of simulation output. Such data imposes a grand challenge to post-processing tasks such as visualization and data analysis, because these tasks are often performed at a host machine that is remotely located and equipped with much less memory and storage resources. During the simulation runs, it is also desirable for scientists to be able to interactively monitor and steer the progress of simulation. This requires scientific data to be represented in an efficient form for initial exploration and computation steering. In this paper, we propose DynaM a software framework that can represent scientific data in a multiresolution form, and dynamically organize data blocks into an optimized layout for efficient scientific analysis. DynaM supports a convolution-based multiresolution data representation for abstracting scientific data for visualization at a wide spectrum of resolution. To support the efficient generation and retrieval of different data granularities from such representation, a dynamic data organization in DynaM is enabled to cater distinct peculiarities of different size data blocks for efficient and balanced I/O performance. Our experimental results demonstrate that DynaM can efficiently represent large scientific dataset and speed up the visualization of multidimensional scientific data. An up to 29 times speedup is achieved on Jaguar supercomputer at Oak Ridge National Laboratory.

Tian, Yuan↗

TU-H-CAMPUS-IeP3-01: Simultaneous PET Restoration and PET/CT Co-Segmentation Using a Variational Method

Purpose: PET images are usually blurred due to the finite spatial resolution, while CT images suffer from low contrast. Segment a tumor from either a single PET or CT image is thus challenging. To make full use of the complementary information between PET and CT, we propose a novel variational method for simultaneous PET image restoration and PET/CT images co-segmentation. Methods: The proposed model was constructed based on the Γ-convergence approximation of Mumford-Shah (MS) segmentation model for PET/CT co-segmentation. Moreover, a PET de-blur process was integrated into the MS model to improve the segmentation accuracy. An interaction edge constraint term over the two modalities were specially designed to share the complementary information. The energy functional was iteratively optimized using an alternate minimization (AM) algorithm. The performance of the proposed method was validated on ten lung cancer cases and five esophageal cancer cases. The ground truth were manually delineated by an experienced radiation oncologist using the complementary visual features of PET and CT. The segmentation accuracy was evaluated by Dice similarity index (DSI) and volume error (VE). Results: The proposed method achieved an expected restoration result for PET image and satisfactory segmentation results for both PET and CT images. For lung cancer dataset, the average DSI (0.72) increased by 0.17 and 0.40 than single PET and CT segmentation. For esophageal cancer dataset, the average DSI (0.85) increased by 0.07 and 0.43 than single PET and CT segmentation. Conclusion: The proposed method took full advantage of the complementary information from PET and CT images. This work was supported in part by the National Cancer Institute Grants R01CA172638. Shan Tan and Laquan Li were supported in part by the National Natural Science Foundation of China, under Grant Nos. 60971112 and 61375018.

60 APPLIED LIFE SCIENCES↗

Quantification of morphological change in materials based on image data utilizing machine learning techniques

Computed tomography (CT) resolution has become high enough to monitor morphological changes due to aging in materials in long-term applications. We explored the utility of the critic of a generative adversarial network (GAN) to automatically detect such changes. The GAN was trained with images of pristine Pharmatose, which is used as a surrogate energetic material. It is important to note that images of the material with altered morphology were only used during the test phase. The GAN-generated images visually reproduced the microstructure of Pharmatose well, although some unrealistic particle fusion was seen. Calculated morphological metrics (volume fraction, interfacial line length, and local thickness) for the synthetic images also showed good agreement with the training data, albeit with signs of mode collapse in the interfacial line length. While the critic exposed changes in particle size, it showed limited ability to distinguish images by particle shape. The detection of shape differences was also a more challenging task for the selected morphological metrics that related to energetic material performance. We further tested the critic with images of aged Pharmatose. Subtle changes due to aging are difficult for the human analyst to detect. Both critic and morphological metrics analysis showed image differentiation.

36 MATERIALS SCIENCE↗

Treatment of Tilted Sonar Data for Salt Cavern Analysis

Structural modeling and visualization of salt caverns requires three-dimensional representations. These representations are typically produced from sonar surveys conducted by companies that then produce a report of depths, distances, and volumes. There are multiple formats that are vendor dependent, and, as technology improves, there have been changes from only horizontal surveys to inclined shots for ceilings and floors to mid-cavern inclined shots. For geomechanical modeling, leaching predictions, and cavern stability visualizations, Sandia has previously written in-house software, called SONAR8, that created a consistent geometry format from the processed sonar reports. However, the increase in the need for mid-cavern inclined surveys led to the discovery of certain limitations in that code. This report describes methods used to process the multiple different formats to handle inclined shots in a consistent and accurate manner in our modeling efforts. A set of file formats and a database schema that was developed for this work is also documented in the appendices.

02 PETROLEUM↗

Effect of pulse sequence parameter selection on signal strength in positive-contrast MRI markers for MRI-based prostate postimplant assessment

Purpose: For postimplant dosimetric assessment, computed tomography (CT) is commonly used to identify prostate brachytherapy seeds, at the expense of accurate anatomical contouring. Magnetic resonance imaging (MRI) is superior to CT for anatomical delineation, but identification of the negative-contrast seeds is challenging. Positive-contrast MRI markers were proposed to replace spacers to assist seed localization on MRI images. Visualization of these markers under varying scan parameters was investigated. Methods: To simulate a clinical scenario, a prostate phantom was implanted with 66 markers and 86 seeds, and imaged on a 3.0T MRI scanner using a 3D fast radiofrequency-spoiled gradient recalled echo acquisition with various combinations of scan parameters. Scan parameters, including flip angle, number of excitations, bandwidth, field-of-view, slice thickness, and encoding steps were systematically varied to study their effects on signal, noise, scan time, image resolution, and artifacts. Results: The effects of pulse sequence parameter selection on the marker signal strength and image noise were characterized. The authors also examined the tradeoff between signal-to-noise ratio, scan time, and image artifacts, such as the wraparound artifact, susceptibility artifact, chemical shift artifact, and partial volume averaging artifact. Given reasonable scan time and managable artifacts, the authors recommended scan parameter combinations that can provide robust visualization of the MRI markers. Conclusions: The recommended MRI pulse sequence protocol allows for consistent visualization of the markers to assist seed localization, potentially enabling MRI-only prostate postimplant dosimetry.

60 APPLIED LIFE SCIENCES↗

Data-Intensive Visual Analysis for Cyber Security

Protecting communications networks against attacks where the aim is to steal information, disrupt order, or harm critical infrastructure can require the collection and analysis of staggering amounts of data. The ability to detect and respond to threats quickly is a paramount concern across sectors, and especially for critical government, utility and financial networks. Yet detecting emerging or incipient threats in immense volumes of network traffic requires new computational and analytic approaches. Network security increasingly requires cooperation between human analysts able to spot suspicious events through means such as data visualization and automated systems that process streaming network data in near real-time to triage events so that human analysts are best able to focus their work.

Pike, William A.↗

Simultaneous {sup 68}Ga-DOTATOC-PET/MRI for IMRT Treatment Planning for Meningioma: First Experience

Purpose: To evaluate intensity-modulated radiotherapy (IMRT) treatment planning based on simultaneous positron-emission tomography and magnetic resonance imaging (PET/MRI) of meningioma. Methods and Materials: A meningioma patient was examined prior to radiotherapy with dedicated planning computed tomography (CT), MRI, PET/CT with gallium-68-labeled DOTATOC ({sup 68}Ga-DOTATOC), and simultaneous {sup 68}Ga-DOTATOC-PET/MRI. The first gross target volume (GTV) was defined based on a combination of separate MR and {sup 68}Ga-DOTATOC-PET/CT imaging (GTV{sub PET/CT+MR}). Then, the simultaneous PET/MR images were used to delineate a second GTV (GTV{sub PET/MR}) by following exactly the same delineation strategy. After an isotropic expansion of those volumes by a 4-mm safety margin, the resulting planning target volumes (PTVs) were compared by calculating the intersection volume and the relative complements. A cross-evaluation of IMRT plans was performed, where the treatment plan created for the PTV{sub PET/CT+MR} was applied to the PET/MR-based PTV{sub PET/MR}. Results: Generally, target volumes for IMRT treatment planning did not differ between MRI plus {sup 68}Ga-DOTATOC-PET/CT and simultaneous PET/MR imaging. Only in certain regions of the GTV were differences observed. The overall volume of the PET/MR-based PTV was approximately the same as that obtained from PET/CT data. A small region of infiltrative tumor growth next to the main tumor mass was better visualized with combined PET/MR due to smaller PET voxel sizes and improved recovery. An IMRT treatment plan was optimized for the PTV{sub PET/CT+MR}. The evaluation of this plan with respect to the PTV{sub PET/MR} showed parts of the target volume that would not have received the full radiation dose after delineation of the tumor, based on simultaneous PET/MR. Conclusion: This case showed that differences in target volumes delineated on the basis of separate MR and PET/CT and simultaneous PET/MR may be observed that can have significant consequences for an effectively applied radiotherapy treatment plan.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantitative Analysis Of Three-dimensional Branching Systems From X-ray Computed Microtomography Data

Branching structures such as lungs, blood vessels and plant roots play a critical role in life. Growth, structure, and function of these branching structures have an immense effect on our lives. Therefore, quantitative size information on such structures in their native environment is invaluable for studying their growth and the effect of the environment on them. X-ray computed tomography (XCT) has been an effective tool for in situ imaging and analysis of branching structures. We developed a costless tool that approximates the surface and volume of branching structures. Our methodology of noninvasive imaging, segmentation and extraction of quantitative information is demonstrated through the analysis of a plant root in its soil medium from 3D tomography data. XCT data collected on a grass specimen was used to visualize its root structure. A suite of open-source software was employed to segment the root from the soil and determine its isosurface, which was used to calculate its volume and surface. This methodology of processing 3D data is applicable to other branching structures even when the structure of interest is of similar x-ray attenuation to its environment and difficulties arise with sample segmentation.

Environmental Molecular Sciences Laboratory↗

Xi-cam : a versatile interface for data visualization and analysis

Xi-cam is an extensible platform for data management, analysis and visualization. Xi-cam aims to provide a flexible and extensible approach to synchrotron data treatment as a solution to rising demands for high-volume/high-throughput processing pipelines. The core of Xi-cam is an extensible plugin-based graphical user interface platform which provides users with an interactive interface to processing algorithms. Plugins are available for SAXS/WAXS/GISAXS/GIWAXS, tomography and NEXAFS data. With Xi-cam 's `advanced' mode, data processing steps are designed as a graph-based workflow, which can be executed live, locally or remotely. Remote execution utilizes high-performance computing or de-localized resources, allowing for the effective reduction of high-throughput data. Xi-cam 's plugin-based architecture targets cross-facility and cross-technique collaborative development, in support of multi-modal analysis. Xi-cam is open-source and cross-platform, and available for download on GitHub.

Pandolfi, Ronald J. (ORCID:0000000308248548)↗

Quantitative Discomanometry: Correlation of Intradiscal Pressure Values to Pain Reduction in Patients With Intervertebral Disc Herniation Treated With Percutaneous, Minimally Invasive, Image-Guided Techniques

Purpose: To illustrate quantitative discomanometry's (QD) diagnostic efficacy and predictive value in discogenic-pain evaluation in a prospective study correlating intradiscal pressure values with pain reduction after percutaneous image-guided technique (i.e., percutaneous decompression, PD). Materials and Methods: During the last 3 years, 36 patients [21 male and 15 female (mean age 36 {+-} 5.8 years)] with intervertebral disc hernia underwent QD before PD. Under absolute sterilization and fluoroscopy, a mixture of contrast medium and normal saline (3:1 ratio) was injected. A discmonitor performed a constant rate injection and recorded pressure and volume values, thus producing the relative pressure-volume curve. PD was then performed. Pain reduction and improved mobility were recorded at 3, 12, and 24 months after PD using clinical evaluation and a numeric visual scale (NVS; 0 to 10 units). Results: Mean pain values of 7.5 {+-} 1.9 (range 4 to 8) NVS units were recorded before PD; these decreased to 2.9 {+-} 2.44 at 3 months, 1.0 {+-} 1.9 at 12 months, and 1.0 {+-} 1.9 NVS units at 24 months after PD. Recorded correlations (pressure, volume, significant pain-reduction values) with bilateral statistical significance included a maximum injected volume of 2.4 ml (p = 0.045), P{sub o} < 14 psi [initial pressure required to inject 0.1 ml of the mixture inside the disc (p = 0.05)], P{sub max} {<=} 65 psi [greatest pressure value on the curve (p = 0.018)], and P{sub max} - P{sub o} {<=} 47 psi (p = 0.038). Patients meeting these pressure or volume cut-off points, either independently or as a total, had significant pain reduction (>4 NVS units) after PD. No complications were noted. Conclusions: QD is an efficient technique that may have predictive value for discogenic pain evaluation. It might serve as a useful tool for patient selection for intervertebral disc therapies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Target Visualization at the National Ignition Facility

As the National Ignition Facility continues its campaign to achieve ignition, new methods and tools will be required to measure the quality of the targets used to achieve this goal. Techniques have been developed to measure target surface features using a phase-shifting diffraction interferometer and Leica Microsystems confocal microscope. Using these techniques we are able to produce a detailed view of the shell surface, which in turn allows us to refine target manufacturing and cleaning processes. However, the volume of data produced limits the methods by which this data can be effectively viewed by a user. This paper introduces an image-based visualization system for data exploration of target shells at the National Ignition Facility (NIF) at Lawrence Livermore National Laboratory. It aims to combine multiple image sets into a single visualization to provide a method of navigating the data in ways that are not possible with existing tools.

42 ENGINEERING↗

3D visualization of polymer nanostructure

Soft materials and structured polymers are extremely useful nanotechnology building blocks. Block copolymers, in particular, have served as 2D masks for nanolithography and 3D scaffolds for photonic crystals, nanoparticle fabrication, and solar cells. F or many of these applications, the precise 3 dimensional structure and the number and type of defects in the polymer is important for ultimate function. However, directly visualizing the 3D structure of a soft material from the nanometer to millimeter length scales is a significant technical challenge. Here, we propose to develop the instrumentation needed for direct 3D structure determination at near nanometer resolution throughout a nearly millimeter-cubed volume of a soft, potentially heterogeneous, material. This new capability will be a valuable research tool for LANL missions in chemistry, materials science, and nanoscience. Our approach to soft materials visualization builds upon exciting developments in super-resolution optical microscopy that have occurred over the past two years. To date, these new, truly revolutionary, imaging methods have been developed and almost exclusively used for biological applications. However, in addition to biological cells, these super-resolution imaging techniques hold extreme promise for direct visualization of many important nanostructured polymers and other heterogeneous chemical systems. Los Alamos has a unique opportunity to lead the development of these super-resolution imaging methods for problems of chemical rather than biological significance. While these optical methods are limited to systems transparent to visible wavelengths, we stress that many important functional chemicals such as polymers, glasses, sol-gels, aerogels, or colloidal assemblies meet this requirement, with specific examples including materials designed for optical communication, manipulation, or light-harvesting Our Research Goals are: (1) Develop the instrumentation necessary for imaging materials at {approx} 10 nm resolution over hundreds of microns in 3 spatial dimensions. Super-resolution microcopy methods based upon single molecule localization were originally limited to 2D slices. Recent advances in this field have extended these methods to three dimensions. However, the 3D rendering was limited to viewing sparsely labeled cellular structures over a z-depth of less than 1 micron. Our first goal is to extend super resolution microscopy to z-depths of hundreds of microns. This substantial improvement is needed to image polymer nanostructure over functionally relevant length scales. (2) Benchmark this instrument by studying the 3D nanostructure of diblock co-polymer morphologies. We will test and benchmark our instrument by imaging fluorescently labeled diblock copolymers, molecules that self-assemble into a variety of 3D nano-structures. We reiterate these polymers are useful for a variety of applications ranging from lithography to light harvesting.

36 MATERIALS SCIENCE↗

PET/MRI of Hepatic 90Y Microsphere Deposition Determines Individual Tumor Response

PurposeThe purpose of our study is to determine if there is a relationship between dose deposition measured by PET/MRI and individual lesion response to yttrium-90 ({sup 90}Y) microsphere radioembolization.Materials and Methods26 patients undergoing lobar treatment with {sup 90}Y microspheres underwent PET/MRI within 66 h of treatment and had follow-up imaging available. Adequate visualization of tumor was available in 24 patients, and contours were drawn on simultaneously acquired PET/MRI data. Dose volume histograms (DVHs) were extracted from dose maps, which were generated using a voxelized dose kernel. Similar contours to capture dimensional and volumetric change of tumors were drawn on follow-up imaging. Response was analyzed using both RECIST and volumetric RECIST (vRECIST) criteria.ResultsA total of 8 hepatocellular carcinoma (HCC), 4 neuroendocrine tumor (NET), 9 colorectal metastases (CRC) patients, and 3 patients with other metastatic disease met inclusion criteria. Average dose was useful in predicting response between responders and non-responders for all lesion types and for CRC lesions alone using both response criteria (p < 0.05). D70 (minimum dose to 70 % of volume) was also useful in predicting response when using vRECIST. No significant trend was seen in the other tumor types. For CRC lesions, an average dose of 29.8 Gy offered 76.9 % sensitivity and 75.9 % specificity for response.ConclusionsPET/MRI of {sup 90}Y microsphere distribution showed significantly higher DVH values for responders than non-responders in patients with CRC. DVH analysis of {sup 90}Y microsphere distribution following treatment may be an important predictor of response and could be used to guide future adaptive therapy trials.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

LLEPE

LLEPE (liquid-liquid equilibrium parameter estimator) is a tool for estimating thermodynamic parameters like standard enthalpies, standard molar volumes and Pitzer coefficients, by combining Gibbs minimization with regression to multiphase equilibrium isotherm data. It also includes visualization tools to access data quality and prediction model performance.

ILOEJE, CHUKWUNWIKE↗

Visual analysis of code security

To help increase the confidence that software is secure, researchers and vendors have developed different kinds of automated software security analysis tools. These tools analyze software for weaknesses and vulnerabilities, but the individual tools catch different vulnerabilities and produce voluminous data with many false positives. This paper describes a system that brings together the results of disparate software analysis tools into a visual environment to support the triage and exploration of code vulnerabilities. Our system allows software developers to explore vulnerability results to uncover hidden trends, triage the most important code weaknesses, and show who is responsible for introducing software vulnerabilities. By correlating and normalizing multiple software analysis tools' data, the overall vulnerability detection coverage of software is increased. A visual overview and powerful interaction allows the user to focus attention on the most pressing vulnerabilities within huge volumes of data, and streamlines the secure software development workflow through integration with development tools.

99 GENERAL AND MISCELLANEOUS↗

Prelude to Simulation Diagnostics in MOOSE: Diagnosing Meshes

As finite element simulations increase in complexity, so does the need for high quality meshes. Without proper diagnostics, issues pertaining to poor mesh quality or improper mesh construction may go undetected, causing simulations to fail unexpectedly. This paper details the new mesh diagnostic system available in MOOSE, which provides users with the tools to inspect mesh quality for both externally and internally generated meshes. This system can detect issues arising from element volume size, non-conformal elements, intersecting edges, missing sidesets, as well as other common mesh issues. As meshes increase in size and complexity, such issues become more difficult to diagnose through visual inspection alone.

99 - GENERAL AND MISCELLANEOUS↗

High Performance Data Analytics on a Commodity Private Cloud

Sandia is researching novel methods of analysis for large datasets. The term “Big Data” has been used frequently in recent years to describe a discipline of computer science that attempts to distil an increasing quantity of data into a result or meaningful subset that can be easily visualized and acted upon by human consumers. These data are frequently characterized by one or more of the following: high volume, velocity, variety, and veracity. Sandia scientists and researchers are no strangers to large datasets, which often typify the result of high-performance computing workloads. The challenge for Sandia data scientists, however, comes at the arrival of exascale computing, which has become mandated by executive order for national computing centers. Because of power and networking limitations, exascale computing precludes the movement of datasets at exascale from data production to data analysis. Such analysis must be done in-situ, to mitigate the time and power costs of network transport. Currently, many of Sandia’s data analytics environments exist as independent entities, often specialized for individual use cases, interconnected to other data analytics, high-performance computing, and storage systems. Sandia is procuring, installing, and researching future platforms for such data analytics. A memory footprint of 256 GB per node, fourteen data rate (FDR) InfiniBand networking, PCIe connected non-volatile memory (NVMe) data storage, and an object data store will characterize the coming institutional data analytics platforms. The combined systems will contain 300 compute nodes. A cloud-inspired software stack resulting from collaboration between the Sandia centers will allow the systems to support a flexible mix of user and system-facing workloads and use cases including code development and testing in R and Python, Apache Hadoop and Spark, distributed in-memory databases, graph analytics, emulytics, system log and predictive analytics, and data visualization for institutional and mission customers. These systems will arrive at the end of FY 2015 and production is planned by the spring of FY 2016.

97 MATHEMATICS AND COMPUTING↗