Electrification Options for Multi-Family Water Heating in Cold Climates - Final Report

In multi-family buildings, large water storage tanks in centralized domestic hot water (DHW) systems can serve as thermal energy storage (TES) batteries to mitigate grid impact. These systems offer demand shift and efficiency benefits, significantly reducing peak power consumption, particularly in cold climates. This study evaluates the load-shifting benefits of a centralized heat pump water heater (HPWH) system equipped with a CO2 heat pump in multi-family buildings through simulation. The heat pump system and water storage tank are sized using design-day sizing. A finite-element-based stratified tank model and CO2 heat pump performance map from a commercial DHW product are used. Annual simulations are conducted to assess the benefits of the centralized DHW system for energy efficiency improvements, load shifting, and emission reductions. These simulations incorporate utility tariffs and marginal grid emission data from Los Angeles and Chicago. In Los Angeles, using a water tank as a thermal battery achieves 7.4% utility cost savings and 10.2% emission reduction. In Chicago, compared to HPWH conventional operation without preheating, TES-enabled central HPWH provides 15% utility cost savings and 13% emission reduction. The case study demonstrates that the demand reduction potential of central CO2 HPWHs is significant in cold climate regions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Paternal preconception alcohol consumption increased Angiotensin II‐mediated vasoconstriction in male offspring cerebral arteries via oxidative stress‐AT1R pathway

Abstract Alcohol consumption is popular worldwidely and closely associated with cardiovascular diseases. Influences of paternal preconception alcohol consumption on offspring cerebral arteries are largely unknown. Male rats were randomly given alcohol or water before being mated with alcohol‐naive females to produce alcohol‐ and control‐sired offspring. Middle cerebral artery (MCA) was tested with a Danish Myo Technology wire myograph, patch‐clamp, IONOPTIX, immunofluorescence and quantitative PCR. Alcohol consumption enhanced angiotensin II (AngII)‐mediated constriction in male offspring MCA mainly via AT1R. PD123,319 only augmented AngII‐induced constriction in control offspring. AngII and Bay K8644 induced stronger intracellular calcium transient in vascular smooth muscle cells (VSMCs) from MCA of alcohol offspring. L‐type voltage‐dependent calcium channel (L‐Ca 2+ ) current at baseline and after AngII‐stimulation was higher in VSMCs. Influence of large‐conductance calcium‐activated potassium channel (BK C a ) was lower. Caffeine induced stronger constriction and intracellular calcium release in alcohol offspring. Superoxide anion was higher in alcohol MCA than control. Tempol and thenoyltrifluoroacetone alleviated AngII‐mediated contractions, while inhibition was significantly higher in alcohol group. The mitochondria were swollen in alcohol MCA. Despite lower Kcnma1 and Prkce expression, many genes expressions were higher in alcohol group. Hypoxia induced reactive oxygen species production and increased AT1R expression in control MCA and rat aorta smooth muscle cell line. In conclusion, this study firstly demonstrated paternal preconception alcohol potentiated AngII‐mediated vasoconstriction in offspring MCA via ROS‐AT1R. Alcohol consumption increased intracellular calcium via L‐Ca 2+ channel and endoplasmic reticulum and decreased BK Ca function. The present study provided new information for male reproductive health and developmental origin of cerebrovascular diseases.

Zhang, Ze↗

Tethys: A Spatiotemporal Downscaling Model for Global Water Demand

Humans use water for many important tasks, such as drinking, growing food, and cooling power plants. Since future water demands depend on complex global interactions between economic sectors (e.g., demand for wheat in one country causing demand for water to grow that wheat in another country), it is often modeled at coarse spatial and temporal scales as part of models that account for complex, multi-sector system dynamics. However, models that project future water availability typically simulate physical processes at much finer scales. Tethys enables integration between these kinds of models by downscaling region-scale water demand projections using sector-specific proxies and formulas.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Developing Near Optimal Control Sequences for Chiller Plants with Water-side Economizers: A Case Study in a Warm and Marine Climate

Various advanced control sequences for chiller plants with water-side economizers (WSE) have been proposed in literature, but the optimization of those controls is limited. It is possible to maximize energy savings by developing near-optimal control sequences, which are dependent on several factors such as the load profile. To address these gaps, we first identify an advanced control sequence and three key control parameters for chiller plants with WSE. Next, optimizations are performed to minimize energy consumption for seven combinations of control parameters. A chiller plant with WSE system in a warm and marine climate is studied and two load profiles are considered. The system and controls are modeled using the Modelica Buildings library. The results show optimizing the selected control parameters can reduce energy consumption by up to 11% depending on the load profile. Specifically, optimizing the cooling tower efficiency threshold in the condenser water reset control can significantly reduce energy savings for the variable load profile by efficiently shifting the load from the cooling tower to the chiller. This paper provides practical guidance for developing near-optimal control sequences for chiller plant with WSE systems considering impacts such as the load profile.

chiller plant↗

Multistage Stochastic optimization for mid-term integrated generation and maintenance scheduling of cascaded hydroelectric system with renewable energy uncertainty

The uncertainties resulting from the escalating penetration of renewable energy resources pose severe challenges to the efficient operation of modern power systems. Hydroelectricity is characterized by its flexibility, controllability, and reliability, and thus becomes one of the most ideal energy resources to hedge against such uncertainties. This paper studies the mid-term integrated generation and maintenance scheduling of a cascaded hydroelectric system (CHS) consisting of multiple cascaded reservoirs and hydroelectric units. To precisely describe the mid-term water regulation policies, the hydraulic coupling relationship and water-energy nexus of CHS are incorporated into the proposed optimization model. The uncertainties of natural water inflow and the power outputs of wind/solar energy generation are taken into consideration and captured via a stochastic process modeled by a scenario tree. A multistage stochastic optimization (MSO) approach is developed to coordinate the complementary operations of multiple energy resources, by optimizing the mid-term water resource management, generation scheduling, and maintenance scheduling of CHS. The proposed MSO model is formulated as a large-scale mixed-integer linear program that presents significant computational intractability. To address this issue, a tailored Benders decomposition algorithm is developed. Two real-world case studies are conducted to demonstrate the capability and characteristics of the proposed model and algorithm. The computational results show that the proposed MSO model can exploit the flexibility of hydroelectricity to efficiently respond to variable wind and solar power, and reserve water resources for the generation in peak months to reduce the consumption of fossil fuel. Furthermore, the proposed solution approach also exhibits promising computational efficiency when handling large-scale models.

13 HYDRO ENERGY↗

Airport Ground Support Equipment Analysis

Ground support equipment (GSE) plays a critical role in providing services to aircraft at arrival and departure gates, ensuring smooth and efficient airport operations. As the airline industry seeks to reduce costs and expand energy options, electric GSE (eGSE) is emerging as a promising solution. This project examines the integration of eGSE into airport operations, addressing key considerations such as vehicle deployment, charging infrastructure, and grid impacts. We developed a flexible, bottom-up modeling framework to evaluate energy demands and infrastructure requirements across more than 300 U.S. airports, providing actionable insights to support electrification planning and implementation. The study focuses on eight major types of GSE with commercially available electric counterparts: aircraft tractors, ground power units, baggage tractors, belt loaders, cargo loaders, catering trucks, lavatory trucks, and water trucks. Project results include annual charging load profiles, total energy consumption, and the charger and fleet requirements for each airport.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Heat Recovery System for Domestic Dishwashers (Final Report)

The objectives of this project were to enable commercialization of a patent-pending technology for unprecedented dishwasher energy savings and non-energy consumer benefits. Specific objectives were to (1) provide customer-requested features of more thorough drying, (2) reduce kitchen humidity load (75% target reduction in water vapor released by the dishwasher), (3) introduce the lowest energy consumption domestic dishwasher on the market with 30% less energy consumption than that of the current best in market, and (4) maintain high cleaning performance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Crossing the Finish Line: Integration of Data-Driven Process Control for Maximization of Energy and Resource Efficiency in Advanced Water Resource Recovery Facilities

Improvements in process monitoring and control at water resource recovery facilities (WRRFs) could result in reductions in electricity consumption, chemical inputs, and greenhouse gas emissions, as well as improved energy recovery. Many current WRRF data collection, monitoring, and control approaches use 20th century process monitoring and control systems, which require large design safety factors to ensure reliability in the absence of more advanced, precise controls. Implementation of more modern data-driven control tools could lead to more efficient operations that provide intrinsic reliability with better overall process performance at full-scale. This project (1) developed and demonstrated data-driven process controls at full-scale facilities for five promising WRRF process technologies that provide whole-plant approaches and offer substantial energy and resource recovery benefits, and (2) created a Machine Learning (ML) Toolkit and an implementation guide of new process control approaches that walks users through each step of the ML workflow and illustrates the steps through case study examples.

54 ENVIRONMENTAL SCIENCES↗

Evaluation of Equivalent Battery Model Representations for Thermostatically Controlled Loads in Commercial Buildings

Models for thermostatically controlled loads in commercial buildings often include many parameters and variables compared to residential buildings. As such, it is beneficial to use reduced-order models to represent these resources. A classic example of such a model is the Virtual Battery or Equivalent Battery Model (EBM). In this paper, the typical EBM is extended to higher-order commercial Heating, Ventilation, and Air-conditioning (HVAC) models and adapted for electric water heaters. Finally, we compare the performance of EBMs with detailed thermal models using three classic optimization problems - energy maximization, energy minimization, and power reference tracking. Our results show that the EBM-constrained and detailed thermal model-constrained problems produce similar outcomes in terms of temperature, power, and total energy consumption.

commercial buildings↗

Scaling Up: Demonstrating Risk Reduction and Cost Compression for Commercial Heat Pump Water Heaters (CRADA 625) (Final Report)

This report is a final deliverable for project 81966: Scaling Up: Demonstrating Risk Reduction and Cost Compression for Commercial Heat Pump Water Heaters (CRADA 625) Commercial heat pump water heater (CHPWH) systems can significantly improve the energy efficiency of service water heating (SWH), aka domestic hot water (DHW), in commercial and multifamily buildings but have not yet achieved widespread adoption due to pricing, complexity, and perceived risk factors. The goal of this project – Scaling Up: Demonstrating Risk Reduction and Cost Compression for Commercial HPWHs (Scaling Up) – was to demonstrate and validate a holistic systems approach for CHPWHs that de-risks the technology, creating a reliable, cost-effective, and repeatable approach to CHPWH deployment.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Pool Boiling Reliability Tests and Degradation Mechanisms of Microporous Copper Inverse Opal (CuIOs) Structures

The rising power density in electronic systems requires thermal management solutions that are both high-performing and reliable. Porous materials such as Copper Inverse Opal (CuIOs) have unique structural features, including high permeability and high thermal conductivity, to enhance pool boiling performance. However, there is little understanding of the degradation mechanism of such porous materials under pool boiling conditions. In this study, samples of 10 ..mu..m thick CuIOs with 4.8 ..mu..m diameter, covering silicon substrate of area 11 mm x 11 mm, with various heated areas ranging from 2.5 mm x 2.5 mm to 10 mm x 10 mm, were tested in 100 degrees C deionized water at a constant heat flux of 110 Wcm -2 for 3-to-7 days. The combined effect of erosion and corrosion caused structural degradation of the CuIOs. The directly heated area had the most severe degradation while the edge of the heater and the unheated area showed progressively less degradation, maintaining some CuIOs structure even after the 7-day reliability test. Among all the tested samples with various heater sizes, the 2.5 mm x 2.5 mm heater sample - in which the heater size was designed to be comparable to the water bubble characteristic length - had the largest critical heat flux (CHF) up to 300 Wcm -2 with a superheat ~ 13 degrees C. Additionally, CuIOs with a smaller heated area performed better in terms of reliability. This study offers preliminary insights into CuIOs degradation mechanisms, contributing to the development of more robust thermal management solutions. We expect that electroless plating of CuIOs with gold (Au), nickel (Ni), and atomic layer deposition (ALD) aluminum oxide (Al 2 O 3 ) in combination with appropriate application-specific coolants will further improve the reliability and lifetime of the CuIOs.

boiling-induced degradation↗

Pool Boiling Reliability Tests and Degradation Mechanisms of Microporous Copper Inverse Opal (CuIOs) Structures: Preprint

The rising power density in electronic systems requires thermal management solutions that are both high-performing and reliable. Porous materials such as Copper Inverse Opals (CuIOs) have unique structural features, including high permeability and high thermal conductivity, to enhance pool boiling performance. However, there is little understanding of the degradation mechanism of such porous materials under pool boiling conditions. In this study, samples of 10-micrometer-thick CuIOs with 4.8-micrometer diameter, covering silicon substrate of area 11-mm by 11-mm, with various heated areas ranging from 2.5-mm by 2.5-mm to 10-mm by 10-mm, were tested in 100 degrees C deionized water at a constant heat flux of 110 watts per square cm for 3-7 days. The combined effect of erosion and corrosion caused structural degradation of the CuIOs. The directly heated area had the most severe degradation while the edge of the heater and the unheated area showed progressively less degradation, maintaining some CuIOs structure even after the 7-day reliability test. Among all the tested samples with various heater sizes, the 2.5-mm by 2.5-mm heater sample - in which the heater size was designed to be comparable to the water bubble characteristic length - had the largest critical heat flux (CHF) up to 300 watts per square cm with a superheat of approximately 13 degrees C. Additionally, CuIOs with a smaller heated area performed better in terms of reliability. This study offers preliminary insights into CuIOs degradation mechanisms, contributing to the development of more robust thermal management solutions. We expect that electroless plating of CuIOs with gold (Au), nickel (Ni), and atomic layer deposition of aluminum oxide in combination with appropriate application-specific coolants will further improve the reliability and lifetime of the CuIOs.

boiling-induced degradation↗

Application of Artificial Neural Network Model for Optimized Control of Condenser Water Temperature Set-Point in a Chilled Water System

Here, in this study, real-time predictive control and optimization model based on an ANN (artificial neural network) was developed to evaluate the cooling energy saving performance of the optimized control of CndWT (condenser water temperature). For this purpose, the difference in TCEC (total cooling energy consumption) between the conventional control strategy when the CndWT produced by the cooling tower is fixed and the optimized control strategy when real-time control of the CndWT through the optimal ANN model is applied was compared and analyzed. For the modeling of the building to be simulated, the co-simulation of EnergyPlus and MATLAB was built through the middleware Building Controls Virtual Test Bed. For the prediction of TCEC, an ANN model was developed through MATLAB's neural network toolbox. The model accuracy of the ANN was examined through Cv(RMSE) index and as a result, Cv(RMSE) of the optimized ANN model turned out to be approximately 25 %. More importantly, the predictive control technique was able to save TCEC by 5.6 % compared to the conventional control method constantly fixing CndWT set-point to 30 °C. These results showed that the CndWT needs to be dynamically controlled using artificial intelligence technique such as ANN model and that significant energy savings were achievable compared to the conventional fixed control.

42 ENGINEERING↗

Modeling of multi-component precipitation and crystallization for zero-liquid-discharge desalination

This study proposes novel ZLD treatment trains that integrate multi-component chemical precipitation and multi-effect evaporative crystallization for efficient brine management. The methodology emphasizes sustainability by integrating CO₂ for chemical precipitation and reducing environmental impact, exemplified with two case studies: produced water that includes industrial waste heat utilization by adopting the emerging vacuum air-gapped membrane distillation (VAGMD) technology, and brackish groundwater that is abundant in sulphate which undergoes treatment by low-salt-rejection reverse osmosis (LSRRO) with interstage chemical precipitation. Here, this study is the first of its kind to simultaneously account for reducing risk of mineral scaling and effective recovery of valuable solids when incorporating VAGMD and LSRRO in ZLD treatment trains. Using Reaktoro and WaterTAP, both Python-based, open-source platforms, we model the recovery of high-purity magnesium, calcium, and sodium salts while optimizing energy consumption and operational efficiency in proposed ZLD pathways for case studies of produced water and brackish desalination brine management. Validation with experimental and reference data confirms the reliability of the models used. In both case studies, the optimized ZLD process achieves recovery rates of 97%, 99%, and 90% for Mg, Ca, and Na, with purities exceeding 99%, and brine volume reduced to less than 4% of the initial feed flow.

3D CT scans↗

Techno-economic analysis of the water, energy, and greenhouse gas emissions impacts from the adoption of water efficiency practices in the U.S. manufacturing sector

Water is a critical resource for all of manufacturing. As such, mitigating risks to the supply of water to manufacturing plants facilitates maintaining a vital manufacturing sector. Reductions in water use through water efficiency is one method for mitigating risk, however little is known about its potential in the United States (U.S.) manufacturing sector. Herein, we address this gap and calculate the water reduction potential in U.S. manufacturing from commercially available water efficiency opportunities specific to the manufacturing sector. A list of water efficiency measures specific to the manufacturing sector is compiled and applied to estimates of U.S. manufacturing water withdrawals. The energy and carbon dioxide equivalent (CO 2 e) emission impacts from implementation of these measures are also quantified to better inform the resource, environmental, and economic trade-offs from implementation of these measures. We find that the water savings potential from the evaluated measures is up to 60 percent of U.S. manufacturing water withdrawal for certain subsectors, with the energy and emissions impact dependent on the measure. Further, we calculate the levelized cost of conserved water for several water efficiency measures (-$\$4,000$ to $\$85$/thousand m 3 , where negative values indicate net cost savings and positive values indicate net cost expenditures) and compare them to the levelized cost of alternative water sources ($\$600$ to $\$3,400$/thousand m 3 ). The results show significant opportunities for water and energy use reductions at levelized costs at least one order of magnitude lower than alternative water supplies, with some being revenue-generating.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Characterizing manufacturing wastewater in the United States for the purpose of analyzing energy requirements for reuse

This paper seeks to inform an improved understanding of the energy tradeoff associated with on-site manufacturing water reuse in the United States from a lifecycle perspective, in part by developing an analytical framework for understanding when this tradeoff for reuse is beneficial. We survey the literature to assess the current state of reuse and its motives and barriers in the United States, before synthesizing information from publicly available EPA data on contaminants in US manufacturing wastewaters and technologies for treating them. Using the available data, we derive a set of “ubiquitous contaminants” among the top ten in terms of mass discharged in more than half of US manufacturing subsectors (NAICS 31–33) according to EPA permit data. We also present information on proven treatment trains and their energy requirements. We then compare water quality requirements for specific contaminants in reclaimed water to those characteristic of wastewater streams currently being discharged from manufacturing plants into surface waters to highlight sectors with reuse opportunities that could require little cost to realize, such as primary metals and, to a lesser extent, petroleum and coal products. We conclude by highlighting data limitations that need to be rectified before applying the framework more broadly and discussing how these data gaps could be filled. Better understanding the relationship between energy and water in the context of on-site manufacturing water reuse would allow manufacturers to improve resiliency by reducing regulatory, physical, and reputational risks while lessening their footprint on local watersheds.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Empirical Dynamic Modeling Reveals Complexity of Methane Fluxes in a Temperate Salt Marsh

Abstract Methane dynamics within salt marshes are complex because vegetation types, temperature, oscillating water levels, and changes in salinity and redox conditions influence CH 4 production, consumption, oxidation, and emissions. These non‐linear and complex interactions among variables affect the traditionally expected functional relationships and present challenges for interpreting and developing process‐based models. We employed empirical dynamic modeling (EDM) and convergent cross mapping (CCM) as a novel approach for characterizing seasonal/multiday and diurnal CH 4 dynamics by inferring causal variables, lags, and interconnections among multiple biophysical variables within a temperate salt marsh using 5 years of eddy covariance data. EDM/CCM is a nonparametric approach capable of quantifying the coupling between variables while determining time scales where variable interactions are the most relevant. We found that gross primary productivity, tidal creek dissolved oxygen, and temperature were important for seasonal/multiday dynamics (rho = 0.73–0.80), while water level was most important for diurnal dynamics during both the growing and dormancy phenoperiods (rho = 0.72 and 0.56, respectively). Lags for the top‐ranked variables (i.e., gross primary productivity, dissolved oxygen, temperature, water level) occurred between 1 and 5 weeks at the seasonal scale and 1–24 hr at the diurnal scale. The EDM had high prediction capabilities for intra‐/inter‐seasonal patterns and annual CH 4 sums but had limitations in representing large, infrequent fluxes. Results highlight the importance of non‐linearity, drivers, lag times, and interconnections among multiple biophysical variables that regulate CH 4 fluxes in tidal wetlands. This research introduces a novel approach to examining CH 4 fluxes, which will aid in evaluating current paradigms in wetlands and other ecosystems.

Environmental Sciences & Ecology↗

Electrohydrodynamic Enabled Electrochemical Membrane Dehumidifier for Separate Sensible and Latent Cooling

In hot and humid parts of the world, air conditioning is a necessity for an adequate standard of living. Cooling and heating represent one-third of building energy consumption. When cooling humid air, a substantial amount of the cooling energy is absorbed by water vapor condensation. The dehumidification cooling load is referred to as the latent cooling load and the dry bulb cooling load is referred to as the sensible cooling load. In most residential applications, the total cooling load is processed by a vapor compression cycle. Processing the latent load separately would not only reduce energy consumption. It would also reduce the required refrigeration capacity. Refrigerants often have adverse ecological impacts, contributing to the greenhouse effect and depletion of the ozone layer. Reduction of the cooling capacity in a system could reduce the amount of refrigerant charge required.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗