Search NASA⌕ Search

SEARCH · Search NASA

Results for “water power technologies”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Levelized cost and carbon intensity of solar hydrogen production via water splitting using a scalable and intrinsically safe photocatalytic Z-scheme raceway system

Generating hydrogen from local energy resources such as solar or wind would unlock a low-carbon energy carrier that could be used to reduce greenhouse gas emissions in sectors such as industry and transportation. Yet, the allocation of new or existing power generation solely to hydrogen production remains contentious due to disputes regarding emissions accounting. Photocatalytic (PC) hydrogen production technologies offer a unique solution, as hydrogen is produced directly from solar energy and water, without the need for electricity generation. However, cost projections for all photocatalytic designs to date have suggested that they are not cost competitive compared to conventional electrolysis systems manufactured at scale. Herein, we offer the first illustrative benchmark of cost and carbon intensity of hydrogen produced in a type 2 “Z-scheme” photocatalytic reactor design, which employs suspended semiconducting nanoconductor particles organized into two stacked volumes in a raceway design. The “Z-scheme” system utilizes two separate photoabsorber particles, tuned to drive either the hydrogen evolution reaction or the oxygen evolution reaction individually, connected via a reversible, charge transfer redox couple in solution. Furthermore, the results suggest a highly competitive and scalable technology, that justifies further experimental validation and prototyping in the field.

Carbon↗

Reports from the Frontier: Understanding Voltage Losses in Anion Exchange Membrane Water Electrolyzers

With the growth of renewable energy sources, hydrogen is attracting significant attention worldwide as an effective medium for energy storage. “Green hydrogen” is currently produced primarily by water electrolysis in which water is split into hydrogen and oxygen using power from low-carbon energy sources such as wind, solar, and nuclear. Among the low temperature water electrolysis technologies, anion exchange membrane water electrolyzers (AEMWEs) have recently emerged as a promising competitor to traditional alkaline water electrolyzers (AWEs) and proton exchange membrane electrolyzers (PEMELs) due to their potential stack cost reduction in various cell components. In conclusion, favorable aspects of AEMWEs include the use of PGM-free electrocatalysts as well as low-cost membranes, bipolar plates (BPs), and porous transport layers while offering high voltage efficiency and durability.

08 HYDROGEN↗

A comparative assessment of the economic viability of nuclear-integrated direct air capture systems

Direct air capture (DAC) systems require heat and electricity to operate, which can be supplied by nuclear power plants (NPPs). In this study, the performance and cost of various conceptual nuclear-DAC systems are assessed, and their performance is compared with several non-nuclear options. Three nuclear-DAC systems are considered: (1) a liquid solvent direct air capture (L-DAC) system with heat supplied from natural gas (NG) and electricity supplied by an NPP, (2) an electrified L-DAC system, fully powered by electricity from an NPP, and (3) a solid sorbent direct air capture (S-DAC) system utilizing both heat and electricity generated by an NPP. Two nuclear technologies are considered: a pressurized water reactor and a high-temperature gas-cooled reactor. Under the medium conservatism scenario, the levelized cost of direct air capture (LCOD) for these systems range from $\$$310/tCO 2 to $\$$525/tCO 2 with the L-DAC system having an NG heat supply at the lower end of the range, and the electrified L-DAC system and the S-DAC system at the higher end of the range. Coupling with nuclear energy led to a 21 % reduction in LCOD for the L-DAC system with NG heat supply and a 29 % reduction for the S-DAC system when compared to fully NG-powered options. When powering the DAC system with grid electricity, the LCOD is highly dependent on the assumed electricity price and carbon intensity. The nuclear option is the cheaper choice when the price of low-carbon grid electricity exceeds $\$$95/MWh and $\$$45/MWh for the L-DAC and S-DAC systems, respectively.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Leveraging a Southern California Energy Innovation Cluster to Pilot and Validate Emerging Energy Technologies

The EPIC Pilot Program, led by the Los Angeles Cleantech Incubator (LACI), was designed to help early-stage clean technology startups accelerate technical validation, investment readiness, and market entry. The project focused on supporting startups in designing and deploying small-scale pilots with the guidance of EPIC Partners, a network of regional stakeholders in the Southern California energy ecosystem, including but not limited to: the Los Angeles Department of Water and Power (LADWP), the California Energy Commission (CEC), Los Angeles County Metropolitan Transportation Authority (LA Metro), and Edison International, among others. Through mentorship, funding, and site access for technology deployments, the program provided a structured pathway for startups to test and refine their technologies in real-world settings.

14 SOLAR ENERGY↗

An Evaluation of The Dynamic Physical Security Risk Assessment Methodology for Fleet-Wide Applications

The requirements for U.S. nuclear power plants to maintain a large onsite physical security force contribute to their high operational costs. The cost of maintaining the current physical security posture is approximately 10% of the overall operation and maintenance budget for commercial nuclear power plants. The goal of the Light Water Reactor Sustainability (LWRS) program’s physical security pathway is to develop tools, methods, and technologies and provide the technical basis for an optimized physical security posture. The conservatisms built into current security postures may be analyzed and minimized to reduce security costs while still ensuring adequate security and operational safety. The research performed at Idaho National Laboratory within LWRS program’s physical security pathway has successfully developed a dynamic force-on-force modeling framework using various computer simulation tools and integrating them with the dynamic assessment Event Modeling Risk Assessment using Linked Diagrams (EMRALD) tool. This integrated process for physical security analysis is named Modeling and Analysis for Safety Security using Dynamic EMRALD Framework (MASS-DEF). This document provides an update on the progress in applying the MASS-DEF process to an operating commercial nuclear power plant as well as additional industry feedback regarding use of the tool for other physical security risk-informed topics. This report is only a summary of the progress and does not contain specific modeling results as those contain sensitive security information. Previous reports described how a user could integrate their plant-specific force-on-force models with the dynamic simulation tool EMRALD, model operator actions, and integrate with probabilistic risk assessment tools, such as CAFTA (Computer Aided Fault Tree Analysis System) or SAPHIRE (Systems Analysis Programs for Hands-on Integrated Reliability Evaluations), and with thermal-hydraulic tools, such as RELAP-5 or MAAP. Previous reports applied various combinations of available simulations codes with EMRALD using generic plant models to demonstrate how to perform the analysis. This report is an update the progress of applying the dynamic computational framework to an actual nuclear facility using their security scenarios and timelines. This report also provides an update to the procedural guidance for the MASS-DEF process and an overview of the generic models available for use by utilities. This report does not contain any plant’s sensitive information and/or safeguards information. This study’s purpose was to verify that the results achieved using generic models are similar to actual plant results and refine our guidance on the use of the framework. This assessment enables further analysis, such as what-if scenarios and staff-reduction evaluation, thereby optimizing physical security at plants.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Plant-specific Model and Data Analysis using Dynamic Security Modeling and Simulation

The requirements for U.S. nuclear power plants to maintain a large on-site physical security force contribute to their high operational costs. The cost of maintaining the current physical security posture is approximately 10% of the overall operation and maintenance budget for commercial nuclear power plants. The goal of the Light Water Reactor Sustainability (LWRS) program’s physical security pathway is to develop tools, methods, and technologies and provide the technical basis for an optimized physical security posture. The conservatisms built into current security postures may be analyzed and minimized in order to reduce security costs while still ensuring adequate security and operational safety. The research performed at Idaho National Laboratory within LWRS program’s physical security pathway has successfully developed a dynamic force-on-force modeling framework using various computer simulation tools and integrating them with the dynamic assessment Event Modeling Risk Assessment using Linked Diagrams (EMRALD) tool. This document provides an update on the progress in applying a dynamic computational framework that links results from a commercially available force-on-force simulation tool, a commercially available thermal-hydraulic tool, and EMRALD to an operating commercial nuclear power plant. This report is only a summary of the progress and does not contain specific modeling results as those contain sensitive security information. This process of including plant procedures and multiple analysis results is being called Modeling and Analysis for Safety Security using Dynamic EMRALD Framework or MASS-DEF. Previous reports described how a user could integrate their plant-specific force-on-force models with the dynamic simulation tool EMRALD, model operator actions, integrate with probabilistic risk assessment tools, such as CAFTA (Computer Aided Fault Tree Analysis System) or SAPHIRE (Systems Analysis Programs for Hands-on Integrated Reliability Evaluations), and with thermal-hydraulic tools, such as RELAP-5. Previous reports applied various combinations of available simulations codes with EMRALD using generic plant models to demonstrate how to perform the analysis. This report documents the results of applying the dynamic computational framework to an actual nuclear facility using their security scenarios and timelines. This report does not contain any plant's sensitive information and/or Safeguards Information. The purpose of this study was to verify that results achieved using generic models are similar to actual plant results and to refine our guidance on the use of the framework. This assessment enables further analysis, such as what-if scenarios and staff-reduction evaluation, thereby optimizing physical security at plants.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Electrochemical deposition of amorphous aluminum oxides on lead pipes to prevent lead leaching into the drinking water

Over 5000 public drinking water systems in the US are out of compliance with the Lead and Copper Rule. Lead leaching from lead pipes is limited by the solubility of a naturally occurring scale. Changes in water quality may cause this scale to become more soluble, releasing lead into the drinking water. We propose a novel electrochemical method to prevent lead leaching from lead pipes. In this method, an aluminum wire and an alkaline phosphate electrolyte are inserted into the pipes. The pipes are then anodized for 2 h by using an external power supply, resulting in the electrodeposition of an insoluble aluminum oxide layer on top of the preexisting scale. This technology was tested on lead pipes from the EBMUD water distribution systems located in Berkeley, CA, using recirculating synthetic and actual tap water for 120 days. The untreated pipes leached an average of 23 ppb and 38 ppb of lead respectively, when using free chlorine and monochloramine as disinfection residuals. In contrast, the treated pipes leached 3 ppb and 5 ppb respectively. These results suggest that the proposed treatment has the potential to prevent lead leaching regardless of the disinfection residual and thus should be further explored in a field trial.

36 MATERIALS SCIENCE↗

Preconceptual Designs of Coupled Power Delivery between a 4-Loop PWR and 100-500 MWe HTSE Plants

This study develops a preconceptual design for the integration between a large-scale high-temperature electrolysis facility and a NPP. Two hydrogen facility sizes are considered: 100 MWnom and 500 MWnom. Both steam supply designs use cold reheat steam extraction as a heat source. A reboiler inside the protected area of the power plant transfers steam heat to the demineralized water supply for the hydrogen plant. After the heat transfer, the extracted steam condenses and returns to the condenser while the process steam routes out of the protected area to the electrolyzers. Electrical power is tapped off from the high voltage side of the GSU transformer, where it is then transported via a 345-kV transmission line to the hydrogen facility. Circuit breakers and disconnects are located at both ends of the transmission line. Step down transformers and miscellaneous switchgear/buses are located at the end of the transmission line inside the HTEF boundary. Control capabilities for the steam interfacing equipment and electrical dispatch are accessible from the Main Control Room, and protective relays for the transmission line are located inside the Relay Room. Computer modeling was performed for the thermal and electrical designs. PEPSE analysis provided the steady-state parameters for thermal extraction from the turbine cycle. These parameters were used to inform transients and size equipment in combination with Applied Flow Technology (AFT) Arrow and AFT Fathom modeling for steam and water piping, respectively. Electrical transients were analyzed using PSCAD. An ETAP model was used to evaluate power flow and short circuit, which enabled the sizing of transformers and protective equipment. A cost estimate was developed for both integration designs when considering plant separation distances of 250 m and 500 m. From these estimates, the modifications for thermal and electrical interfacing of a first-of-a-kind nuclear-integrated hydrogen facility are anticipated to cost between $60–250/kWnom., where the subscript “nom” refers to the nominal size of the hydrogen plant. On a thermal power basis, the thermal power has a cost of approximately $8/MWth for a 500 MWnom high temperature electrolysis plant located 500 m distant from the NPP. That value decreases to approximately $7.5/MWth for a 250 m separation distance between the hydrogen plant and the NPP. This value is lower than previous estimates of the cost of heat extracted from NPPs primarily because in this work the steam is extracted from cold reheat instead of the main steam line, which reduces the cost of the dispatched steam by approximately $3.5/MWth. Nuclear steam extraction can provide a profit avenue for many plants and is not restricted to hydrogen production. Ammonia production, oil refining, and paper production, among other industrial processes all require thermal energy, which can be provided by NPPs. Future work should look further at the details of thermal extraction for a variety of use cases. This can include increased levels of extraction and multiple simultaneous users. Additionally, site-specific studies should be performed to develop industry experience and improve cost accuracy.

08 HYDROGEN↗

Supercritical Carbon Dioxide Primary Power Large-Scale Pilot Plant

The United States electrical power generation fleet encompasses a wide range of technologies, ranging from traditional combustion-based power generation, to nuclear power, to renewable energy. While the distribution of these assets continues to shift due to economic and regulatory influences, coal combustion continues to be a key part of the US energy portfolio. Despite the relative maturity of coal combustion technology, improvements in overall fuel-to-power efficiency and generation flexibility are still possible and will improve both the economic and environmental factors of coal combustion. Echogen Power Systems proposes to lead a world-class team including the University of Missouri, Electric Power Research Institute and Louis Perry Associates in the design, construction and operation of a 10MWe coal-fired supercritical carbon dioxide (sCO 2 ) large-scale pilot. This transformational technology uses sCO 2 as a working fluid instead of water to achieve high thermodynamic efficiencies that can significantly exceed advanced steam-Rankine cycles. Further, the compact nature of sCO 2 turbomachinery offers capital cost and footprint advantages, and the low maintenance of a water-free power cycle can significantly reduce operation and maintenance (O&M) costs over conventional steam-Rankine systems. Recent integration studies of sCO 2 with coal combustion power plants highlight the significant improvements in plant efficiency that sCO 2 can offer relative to even advanced steam Rankine cycles. At commercial scales, coal-sCO 2 plant net efficiency is predicted to be 39-44.0% (HHV), or 10-20% higher output than conventional steam-Rankine systems, which will significantly improve the competitiveness of coal-fired generation. This proposal builds upon projects previously funded by the Department of Energy, including DE-FE0025959 (High-Efficiency Thermal Integration of Closed Supercritical CO 2 Brayton Power Cycles with Oxy-Fired Heaters) and DE-NE0008470 (Conceptual Design for sCO 2 Power Cycle Test Facility). An appropriately-scaled and properly designed and operated pilot project is essential to overcome the natural risk-aversion of the power generation industry and project financing community. The 10 MWe coal-fired sCO 2 pilot power plant proposed herein will reduce the technical and economic risk of this transformational technology, enabling commercial deployment at the conclusion of the project. For the second phase of this project, Echogen lead a team that completed and refined the pilot system conceptual system and key component designs resulting in the completion of a front-end-engineering-design (FEED) study, completed the NEPA review process, completed the permitting process for construction and operation, refined the techno-economic analysis of the proposed system at commercial scale and received commitments for Phase III cost share. The end result of the program will be to demonstrate the technical and economic superiority of the sCO 2 power cycle for coal-fired operation. Major risk elements will have been retired with sufficient operation at high power to enable the power generation industry to move forward with the first commercial deployment of this transformational system.

01 COAL, LIGNITE, AND PEAT↗

Can Food–Energy–Water Nexus Research Keep Pace with Agricultural Innovation?

The interconnection among food–energy–water (FEW) systems in meeting societal demands is broadly acknowledged. Similarly, competitive or synergistic allocations of water and energy resources for agricultural production, manufacturing, and human consumption are understood, and their economic impacts can be predicted. Far less appreciated and understood are the outcomes of the FEW nexus in response to operation changes in agricultural practices and the associated technological innovations for future generations. Also, the inter-scale and feedback effects of emerging technology-driven resource reallocation and decision-making on FEW systems are largely unknown. For example, how do the agroeconomic feedbacks of intelligent technologies influence the FEW nexus of agricultural production under environmental and demographic changes? How does the necessary water allocation for powering non-powered dams and pumped-storage hydropower generation influence agricultural production and municipal water supply maintenance? How do solar and wind energy farms influence land use for agriculture and the rural economy? In turn, how can the generated solar and wind energy help reduce the cost of groundwater extraction or water desalination?

42 ENGINEERING↗

Advancing the HERO WEC Through Integrated Modeling, Testing, and Field Deployments: Preprint

The Hydraulic and Electric Reverse Osmosis Wave Energy Converter (HERO WEC) was developed by the National Laboratory of the Rockies as a modular platform for advancing wave-powered desalination technologies. Designed to operate in either a hydraulic or electric configuration, the system enables direct comparison of mechanical-to-water and electrical-to-water conversion pathways using a single hardware architecture. Deployments at the Jennette's Pier test site in 2022 and 2024 demonstrated freshwater production between 60 and 300 gallons per day, including successful operation in wave heights as low as 0.25 m. A structured evaluation approach combining numerical modeling of hydrodynamic and PTO response, controlled laboratory testing, and in-ocean field deployments has been used to characterize and refine system performance. Insights from these efforts are now informing the second-generation HERO WEC (V2), which incorporates improved drivetrain components, refined geometry, enhanced control systems, and design updates aimed at increasing robustness and long-duration survivability. The HERO WEC platform continues to serve as an open-access research asset supporting broader marine energy and desalination development.

16 TIDAL AND WAVE POWER↗

In-Sodium Testing of a Prototype Thermoacoustic Power Sensor for Sodium-Cooled Fast Reactors

The ultimate goal of this project is to develop and demonstrate a thermoacoustic power sensor (TAPS) for Sodium-Cooled Fast Reactors (SFRs), with potential application also envisioned to other nuclear technologies such as Lead-Cooled Fast Reactors (LFRs), Molten Salt Reactors (MSRs), in addition to Light Water Reactors (LWRs). The project was led by Westinghouse Electric Company, LLC (Westinghouse) and carried out in collaboration with Argonne National Laboratory (ANL) and the University of Pittsburgh. A TAPS is a passive (self-powered), non-invasive (wireless) sensor envisioned for measuring key parameters, such as local temperature and neutron flux, in a nuclear reactor core. The sensor generates pressure waves (i.e., sound waves) with a frequency and amplitude dependent upon nuclear operating conditions (coolant temperature or power changes). The acoustic waves are able to travel through the core and associated structures, and reach to the sensor network placed outside and/or inside of the reactor vessel. These sensors require a very small amount of power which, during loss of power events, can be provided, for example, by harvesting gamma radiation energy, thus resulting in a monitoring system that can function both during normal operation and during loss of power events. Westinghouse and the University of Pittsburgh designed and fabricated TAPS prototypes for Argonne National Laboratory (ANL) to carry out in-sodium testing to evaluate the effects of sodium on the TAPS and the performance of the TAPS technique in sodium. Argonne received a TAPS prototype from Westinghouse, and the prototype was modified such that it can be installed into a test vessel and function in sodium at elevated temperature without potentially leaking. A water mockup test apparatus was constructed to validate proper working of the prototype. An instrumentation and control (I&C) system, running on the National Instruments (NI) LabView platform, was developed to: 1) operate both the water mockup test and the in-sodium test facility; and 2) process and analyze the received acoustic signals from an array of accelerometers and the Argonne sodium-submersible high-temperature acoustic sensor. The prototype was successfully tested in a water bath at different temperatures. Water mockup tests demonstrated that the TAPS prototype is working properly and its resonance frequency changes linearly with the coolant (water) temperature. A TAPS test apparatus was constructed and integrated with the upgraded Under-Sodium Viewing (USV) sodium test facility. The integrated USV-TAPS sodium test facility has been operational. The TAPS prototype and a high-temperature sodium-submersible acoustic sensor (SSAS) developed by Argonne were both installed inside the TAPS test vessel. Being operated within argon cover gas under ambient conditions, the TAPS prototype demonstrated that it was functioning properly with a resonance frequency at 1407.2 Hz, which was successfully detected by the accelerometers mounted on the external wall of the vessel and the high-temperature SSAS installed inside the vessel. After successfully transferring sodium into the vessel, in-sodium tests of the prototype were conducted. Tests of the TAPS prototype demonstrated that the resonance frequency of the TAPS changes linearly with respect to the temperature difference between the interior of the TAPS and bulk sodium. The early tests showed that the TAPS prototype could not establish a continuous and consistent resonance in sodium. The resonance diminished before the prototype reached its operating temperature. A signal postprocessor was added to the DAQ module latterly to isolate interferences, enhance signal conditioning, improve peak detection, and generate resonance frequency versus temperature plots. After testing in molten sodium and immersion at higher temperature for several weeks, the TAPS prototype was able to establish a continuous resonance. Performance evaluation of the TAPS prototype was then conducted in sodium. The tests included the investigation of 1) the effects of the temperature difference between the TAPS and bulk sodium, 2) the effects of sodium flowrate; and 3) the performance of the different sensor-receiver systems positioned inside or outside the vessel. Results of a test demonstrated that, with limited sodium circulation, a continuous and consistent resonance of the TAPS prototype was established occasionally. The tests also demonstrated that, because of the nature of detection principles and mounting methods, the high temperature SSAS is more affected by acoustic noise, while accelerometers are more affected by vibrations, in the test environment. It is unknown why the TAPS prototype only occasionally established a continuous and consistent resonance when the TAPS temperature reached its operating temperature in molten sodium, and why it ultimately failed to resonate at all. A failure modes assessment was conducted and a few potential causes of failure were identified. Different post in-sodium tests were conducted to obtain additional information potentially relevant to the cause of the failure. Nondestructive evaluation techniques are suggested to examine the internal integrity as well as the gas mixture of the prototype. If they prove inconclusive, the prototype should be cut open to conduct a thorough inspection of its internal integrity and determine the state of the gas mixture.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of reverse osmosis membrane with large feed pressure fluctuations from a wave-driven desalination system

Wave-driven desalination systems are proposed water treatment systems that involve reverse osmosis of seawater powered directly by wave motion. Such a configuration would result in drastic feed pressure fluctuations. For a technology conventionally operated with a constant feed condition, the effect of these variable pressures on membrane integrity and performance is unknown. Here, experiments were conducted with spiral wound membranes coupled to a system capable of producing feed pressure fluctuations of more than 400 psi. Feed composition included 5, 20, and 35 g/L NaCl, and a synthetic seawater at normal and 1.5x concentration. The variable feed conditions included sine-like pressure waves swings of 200-500 and 500-900 psi with frequencies of 1.25, 7.5, and 12 waves/min, and a model-generated random waveform. Between each wave experiment we performed membrane integrity tests at 650 psi and 25 g/L NaCl feed, which showed a 7.4% drop in the membrane's water permeability coefficient, an 18.4% flux decline, and more than 99% salt rejection over 1770 h of cumulative experimental time. Analysis of permeate samples showed high salt rejection. In general, variable feed pressure had no significant deleterious effect on membrane integrity or performance.

16 TIDAL AND WAVE POWER↗

Advanced Water-Related Technology Performance Development

This U.S. Department of Energy/National Energy Technology Laboratory techno-economic analysis evaluates those parameters having the greatest performance and cost impact on wet flue gas desulfurization (FGD) effluent wastewater treatment systems, and air cooled condensers for dry cooling systems. Two supercritical pulverized coal power plants are considered: 1) an existing plant (modified for surface water discharge and air emissions consistent with limits for existing plants) retrofitted with wet FGD effluent wastewater treatment and 2) a greenfield plant constructed with an air-cooled condenser (ACC). Sensitivity analyses are completed on various process parameters associated with the wet FGD effluent wastewater treatment system and ACC to determine the impact on the net plant efficiency and levelized cost of electricity (LCOE). Research and development targets are recommended for the parameters shown to have the greatest potential impact on cost or performance.

20 FOSSIL-FUELED POWER PLANTS↗

Application of electron beam technology to decompose persistent emerging drinking water contaminants: poly- and perfluoroalkyl substances (PFAS) and 1,4 dioxane.

Fermi Research Alliance, LLC (FRA) operates Fermilab under contract with the U.S. Department of Energy and has patents on technologies and applications of a novel mobile electron beam accelerator. A high-power version of this mobile accelerator based on FRA-developed SRF technology is under development at Illinois Accelerator Research Center (IARC) and can enable several new applications that have significant commercial potential. One such application is the e-beam treatment of persistent emerging contaminants in drinking water. The contaminants of concern are poly- and perfluoroalklyl substances (PFAS) and 1,4-dioxine. Both PFAS and 1,4-D are highly resistant to degradation and are not effectively removed by conventional drinking water treatment systems. Existing technologies, such as granular activated carbon (GAC) filters and reverse osmosis (RO) systems do not decompose. The Center for Clean Water Technology (CCWT) at Stony Brook University (SBU) is in the process of identifying and testing effective technologies to remove PFAS and/or 1,4-D from drinking waters. se PFAS, but rather concentrate them either by adsorption (GAC) or membrane rejection (RO). The Center for Clean Water Technology (CCWT) at Stony Brook University (SBU) is in the process of identifying and testing effective technologies to remove PFAS and/or 1,4-D from drinking waters to demonstrate the full-scale application of novel water treatment technologies and is experienced in conducting research to understand treatment performance with a particular focus on 1,4-D and PFAS contamination.

43 PARTICLE ACCELERATORS↗

A novel approach for produced water treatment: Supercritical water oxidation and desalination

Produced water generated from oil and gas operations contains significant quantities of environmentally hazardous hydrocarbons, organic chemicals, and inorganic salts. Environmental regulations with impaired water disposal mandates produced water treatment and desalination. Industry standard desalination technologies are energy-intensive and mandate extensive produced water pre-treatment including removal of hydrocarbons constituents for efficient operations. Herein this study investigates a novel process intensification approach integrating supercritical water oxidation (SCWO) unit operation with a supercritical water desalination (SCWD) process for energy efficient produced water treatment and desalination. The coupled SCWD-SCWO process is found to be very energy-efficient and cost effective than existing industry standard desalination technologies. For energy efficient operation, the heat generated from the SCWO of hydrocarbons present in the produced water is used for power generation using a high efficiency and low-cost re-heat Rankine cycle process. The cost of treating produced water with proposed SCWO-SCWD process is independent of the salt concentration. The proposed process has the potential to offer step-change improvements over conventional processes in both the efficiency and cost of produced water treatment: for example, a cost and energy saving of 70% and 100% is calculated for the treatment of produced water containing 250 g/l salt and 10.6 g/l hydrocarbon.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Rare Earth Elements (REE) and Critical Minerals (CM) in Middle Pennsylvanian-Age Coals and Associated Sediments in the Central Appalachian Basin, Eastern U.S.A.

The Central Appalachian Basin (CAB) of Kentucky, Tennessee, West Virginia and Virginia has a long history of coal mining and oil and gas extraction that has empowered the regional and national economies, the development of infrastructure, and a highly trained energy resources work force. As our societal demands for advanced technologies have rapidly increased in recent years, coal-related materials are viewed as an important new unconventional domestic source of critical minerals (CM) that are required for telecommunications, aerospace and transportation industries, electronics, the transition to low-carbon emissions energy production, and many consumer products. Coal-related materials encompass coal, associated sediments, coal mining waste materials, produced waters, and ash residues from coal-fired power plants. An important objective of the Evolve Central Appalachia Project (Evolve CAPP), sponsored by the U.S. Department of Energy (DOE) National Energy Technology Laboratory (NETL) is to assess the quantity and distribution of CM resources in the CAB region. The rare earth elements (REE) are considered highest priority, although other important CM such as niobium, gallium, and zirconium are known to occur in the Middle Pennsylvanian-age coals and sediments. Working with coal industry partners who provided access to drill cores, coal-related sediments and waste materials, over 600 samples have been collected for laboratory analysis, and over 730 materials have been scanned using portable x-ray fluorescence (pXRF) equipment. The application of pXRF provides the means for real-time semiquantitative analysis of CM content at very close spacings (typically 2-3 inch intervals) along drill core and in-situ channel samples that span the roof, coal seam, and floor rock. The comparison of pXRF geochemical data with laboratory results, geologic data, and downhole spectral gamma logs can provide high resolution input to lithologic and depositional models for future CM resource evaluations. The preliminary findings show that pXRF is capable of accurately measuring low concentrations of many of the CM with a high level of confidence (Ba, Cr, Ga, K, Nb, Rb, Sr, Th, Y), whereas for others (La, Ce, Co, Mn, Nd, Ni, Sc, Ti, V) the detection limits are very high or spectral interferences increase the uncertainty. Notably, the mean abundances of Y (34 ppm), La (86 ppm), Ga (40 ppm), and V (146 ppm) in coal underclays in the CAB region are up to 7X enriched compared with the overlying coal. These values also exceed the reported concentrations in published reference materials for upper continental crustal rocks (Rudnick and Gao, 2003), North American Shale Composite (Gromet et al., 1984), and North American coal (Finkelman, 1993). The pXRF data are in part verified by laboratory results that indicate the mean Y abundance (36 ppm) is highly correlated (R2 = 0.807) with total REE (ΣREE). The correlation is even higher (R2 = 0.957) with heavy REE (ΣHREE). Applying these correlations to the pXRF data for the coal underclays, the mean estimated values for ΣREE+Y and ΣHREE+Y are 270 ppm and 58 ppm, respectively. Although these average values are not considered high, the range of Y measured by pXRF in the coal underclays extended as high as 114 ppm, which would suggest ΣREE+Y equal to 847 ppm. The mean abundances of Zr (192 ppm) and Th (21 ppm) in coal underclays are also enriched compared with the overlying coal and these results likely reflect the presence of resistant detrital heavy minerals such as monazite, xenotime, and zircon in the underclay matrix. Several of the profiled coal seams and associated wall rocks contained thin volcanic ash layers up to 4-5 inches in thickness. The extent to which these ash fall layers provided a source for CM under the paleoenvironmental conditions that resulted in coal deposits in the CAB remains to be fully studied. Continuing investigations in the Evolve CAPP study area will include laboratory determinations of mineralogic and clay compositions, and evaluations of CM geochemical mobility in the coal and coal underclays.

Lassetter, Billy↗