Atom Probe Tomography Analysis of Mica

Laser-assisted atom probe tomography (APT) is a relatively new, powerful technique for sub-nanometric mineral and biomineral analysis. However, the laser-assisted APT analysis of highly anisotropic and chemically diverse minerals, such as phyllosilicates, may prove especially challenging due to the complex interaction between the crystal structure and the laser pulse upon applying a high electric field. Micas are a representative group of nonswelling clay minerals of relevance to a number of scientific and technological fields. In this study, a Mg-rich biotite was analyzed by APT to generate preliminary data on nonisotropic minerals and to investigate the effect of the crystallographic orientation on mica chemical composition and structure estimation. Here, the difference in results obtained for specimens extracted from the (001) and ( hk 0) mica surfaces indicate the importance of both experimental parameters and the crystallography. Anisotropy of mica has a strong influence on the physicochemical properties of the mineral during field evaporation and the interpretation of APT data. The promising results obtained in the present study open the way to future innovative APT applications on mica and clay minerals and contribute to the general discussion on the challenges for the analysis of geomaterials by atom probe tomography.

3D reconstructions↗

Time of Flight Secondary Ion Mass Spectrometry for Characterization of Pt-Coated Porous Transport Layers in PEM Water Electrolyzers

Titanium-based porous transport layers (PTLs) and iridium-based catalyst layers (CLs) are two main components of proton exchange membrane water electrolyzers (PEMWEs). PTLs are typically coated with platinum to minimize interfacial losses and to support long-term operation. Optimizing coatings and the PTL-CL interface requires comprehensive characterization. This study establishes time-of-flight secondary ion mass spectrometry (ToF-SIMS) as a valuable technique for PTL characterization, addressing capabilities and limitations related to PTL morphology. A methodology was developed that uses a Cs + sputter beam for dynamic depth profiling, with data collected in both positive-ion (MCs + ) and negative-ion modes to generate depth profiles, 2D ion maps, and 3D ion reconstructions. ToF-SIMS detected relative differences in platinum-layer thickness between samples; these trends were validated by cross-sectional scanning transmission electron microscope (STEM) measurements and flat-titanium substrate controls. Interfacial oxide layers are identified in both ion modes, with enhanced oxide sensitivity in negative mode. The technique’s high sensitivity enables detection of nanometer-scale coatings and trace impurities within the bulk PTL structure. These results provide a methodological framework for analyzing Pt-coated PTLs, with the potential to extend to other components in PEMWEs and other electrolyzer systems.

36 MATERIALS SCIENCE↗

Determinants of synapse diversity revealed by super-resolution quantal transmission and active zone imaging

Neural circuit function depends on the pattern of synaptic connections between neurons and the strength of those connections. Synaptic strength is determined by both postsynaptic sensitivity to neurotransmitter and the presynaptic probability of action potential evoked transmitter release (P r ). Whereas morphology and neurotransmitter receptor number indicate postsynaptic sensitivity, presynaptic indicators and the mechanism that sets P r remain to be defined. To address this, we developed QuaSOR, a super-resolution method for determining P r from quantal synaptic transmission imaging at hundreds of glutamatergic synapses at a time. We mapped the P r onto super-resolution 3D molecular reconstructions of the presynaptic active zones (AZs) of the same synapses at the Drosophila larval neuromuscular junction (NMJ). We find that P r varies greatly between synapses made by a single axon, quantify the contribution of key AZ proteins to P r diversity and find that one of these, Complexin, suppresses spontaneous and evoked transmission differentially, thereby generating a spatial and quantitative mismatch between release modes. Transmission is thus regulated by the balance and nanoscale distribution of release-enhancing and suppressing presynaptic proteins to generate high signal-to-noise evoked transmission.

59 BASIC BIOLOGICAL SCIENCES↗

3D mapping of residual stresses in growing grains of partially recrystallized Gum Metal

The crystallographic orientations and residual stresses within recrystallizing grains in partially recrystallized beta titanium-Gum Metal-were examined non-destructively in 3D using synchrotron Differential Aperture X-ray Microscopy. Contrary to common assumptions, significant local stresses and stress variations are observed within the recrystallizing grains. The results reveal that the development of these local residual stresses depends on the plastic deformation mode and material's elastic constants, rather than grain properties such as size and orientation, or even the material's yield stress. This work provides insights valuable for the design of advanced materials with heterogeneous microstructures.

36 MATERIALS SCIENCE↗

Inference of the linear matter power spectrum at z = 0 using DESI DR1 Full-Shape data

Measurements of galaxy distributions at large cosmic distances capture clustering from the past. In this study, we use a cosmological model to translate these observations into the present-day galaxy distribution. Specifically, we reconstruct the 3D linear matter power spectrum at redshift z = 0 using Dark Energy Spectroscopic Instrument (DESI) Year 1 (DR1) galaxy clustering data and Cosmic Microwave Background (CMB) observations, assuming the ΛCDM model, and compare it to the result assuming the w 0 w a CDM model. Building on previous state-of-the-art methods, we apply Effective Field Theory (EFT) modelling of the galaxy power spectrum to account for small-scale effects in the 2-point statistics of galaxy data. Implementation of the EFT approach improves the modelling of the galaxy power spectrum, providing a more robust consistency test of the assumed cosmological model. By casting both CMB and galaxy clustering observations, spanning distinct redshift regimes, into k-space, we can identify discrepancies between the datasets of different redshifts, which would indicate potential inaccuracies in the assumed expansion history. While previous studies have shown consistency with ΛCDM, this work extends the analysis with higher-quality data to further test the expansion histories of both ΛCDM and w 0 w a CDM. Our findings show that both ΛCDM and w 0 w a CDM provide consistent fits to the linear matter power spectrum recovered from DESI DR1 data.

cosmological parameters from LSS↗

The DUNE Far Detector Vertical Drift Technology. Technical Design Report

DUNE is an international experiment dedicated to addressing some of the questions at the forefront of particle physics and astrophysics, including the mystifying preponderance of matter over antimatter in the early universe. The dual-site experiment will employ an intense neutrino beam focused on a near and a far detector as it aims to determine the neutrino mass hierarchy and to make high-precision measurements of the PMNS matrix parameters, including the CP-violating phase. It will also stand ready to observe supernova neutrino bursts, and seeks to observe nucleon decay as a signature of a grand unified theory underlying the standard model. The DUNE far detector implements liquid argon time-projection chamber (LArTPC) technology, and combines the many tens-of-kiloton fiducial mass necessary for rare event searches with the sub-centimeter spatial resolution required to image those events with high precision. The addition of a photon detection system enhances physics capabilities for all DUNE physics drivers and opens prospects for further physics explorations. Given its size, the far detector will be implemented as a set of modules, with LArTPC designs that differ from one another as newer technologies arise. In the vertical drift LArTPC design, a horizontal cathode bisects the detector, creating two stacked drift volumes in which ionization charges drift towards anodes at either the top or bottom. The anodes are composed of perforated PCB layers with conductive strips, enabling reconstruction in 3D. Light-trap-style photon detection modules are placed both on the cryostat's side walls and on the central cathode where they are optically powered. This Technical Design Report describes in detail the technical implementations of each subsystem of this LArTPC that, together with the other far detector modules and the near detector, will enable DUNE to achieve its physics goals.

47 OTHER INSTRUMENTATION↗

Characterizing crystalline defects in single nanoparticles from angular correlations of single-shot diffracted X-rays

Characterizing and controlling the uniformity of nanoparticles is crucial for their application in science and technology because crystalline defects in the nanoparticles strongly affect their unique properties. Recently, ultra-short and ultra-bright X-ray pulses provided by X-ray free-electron lasers (XFELs) opened up the possibility of structure determination of nanometre-scale matter with Å spatial resolution. However, it is often difficult to reconstruct the 3D structural information from single-shot X-ray diffraction patterns owing to the random orientation of the particles. This report proposes an analysis approach for characterizing defects in nanoparticles using wide-angle X-ray scattering (WAXS) data from free-flying single nanoparticles. The analysis method is based on the concept of correlated X-ray scattering, in which correlations of scattered X-ray are used to recover detailed structural information. WAXS experiments of xenon nanoparticles, or clusters, were conducted at an XFEL facility in Japan by using the SPring-8 Ångstrom compact free-electron laser (SACLA). Bragg spots in the recorded single-shot X-ray diffraction patterns showed clear angular correlations, which offered significant structural information on the nanoparticles. The experimental angular correlations were reproduced by numerical simulation in which kinematical theory of diffraction was combined with geometric calculations. We also explain the diffuse scattering intensity as being due to the stacking faults in the xenon clusters.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Real-time High-resolution X-Ray Computed Tomography

Computed Tomography (CT) serves as a key imaging technology that relies on computationally intensive filtering and back-projection algorithms for 3D image reconstruction. While conventional high-resolution image reconstruction (> 2K3) solutions provide quick results, they typically treat reconstruction as an offline workload to be performed remotely on large-scale HPC systems. The growing demand for post-construction AI-driven analytics and the need for real-time adjustments call for high-resolution reconstruction solutions that are feasible on local computing resources, i.e. a multi-GPU server at most. In this paper, we propose a novel approach that utilizes Tensor Cores to optimize image reconstruction without sacrificing precision. We also introduce a framework designed to enable real-time execution of end-to-end distributed image reconstruction in a multi-GPU environment. Evaluations conducted on a single Nvidia A100 and H100 GPU show performance improvements of 1.91 × and 2.15 × compared to highly optimized production libraries. Furthermore, our framework, when deployed on 8-card Nvidia A100 GPU system, demonstrates the ability to reconstruct real-world datasets into 20483 volumes (32 GB) in slightly more than one minute and 40963 volumes (256 GB) in 7 minutes.

Wu, Du↗

STELLOPT

The STELLOPT code is designed to optimize 3D MHD equilibria to a set of target physics parameters encompassing stellarator design and 3D equilibrium reconstructions.

Lazerson, Samuel↗

Tike

Tike is a library for reconstructing a 3D object from its diffraction measurements.

Gursoy, Doga↗

Long Term Degradation of LSM Based SOFC Cathodes: Use of a Proven Accelerated Test Regimen

The overall goals of the program were: • To understand the microstructural basis of long-term performance loss in solid oxide fuel cells (SOFCs) with cathodes based on lanthanum strontium manganite (LSM, (La 1–x Sr x ) 1–yM nO 3±z ); • To develop strategies for optimizing LSM–based cathodes that achieve improved long-term performance, while exhibiting microstructural and chemical stability, for commercial fuel cell systems. The research project carried out accelerated testing of SOFCs with LSM-based cathodes of selected compositions. After intervals of accelerated testing (and control tests using non-accelerated conditions), the cells underwent extensive microstructural characterization to determine the physical and chemical changes in the cells. By analysis of a) the results of the testing, b) the observed microstructural changes, and c) the differences in these correlations between different cathode compositions and test durations, the research: • Identified a correlation between microstructural change and performance loss: specifically, between decrease of three-phase boundary (TPB) density and increase of area specific re-sistance (ASR) during operation; • Identified a cathode composition parameter — Mn excess, defined as 1/(1–y) in (La 1–x Sr x ) 1–y MnO 3±z ) — and how it affects TPB density, ASR and change of cell performance over time.

08 HYDROGEN↗

Modeling Nondestructive Defect Detection in Additively Manufactured Metallic Structures for Nuclear Applications

The future of quickly, economically produced metallic nuclear reactor parts with minimal supply-chain dependence lies in Laser Powder Bed Fusion (LPBF) Additive Manufacturing (AM): a 3D printing method involving laser melting and net shaping stainless steel and Inconel metallic powder into a solid structure. However, intrinsic features in LPBF frequently leads to the formation of materials defects, such as pores, within 3D printed structures. As safe long-term use in energy applications requires knowledge of all relevant defects before deployment in a reactor, we must develop methods for nondestructive detection of these defects. We are investigating Pulsed Thermal Tomography (PTT), which is a non-contact nondestructive imaging method scalable to arbitrary structure size. Thermal tomography (TT) is a computational method for 3D spatial reconstruction of material thermal effusivity from flash or pulsed thermography temperature data cube. Thermography data cube consists of 2D surface temperature measurements at different times. The objective of the present work is to investigate limits on defect detection in AM metallic structures with PTT. To this effect, we modeled PTT with COMSOL heat transfer computer simulations. We developed a layered media COMSOL simulation consisting of a Stainless Steel 316 (SS316) plate with an internal layer of un-sintered SS316 powder. Thermophysical properties of the powder layer were modeled with equivalent volume mixing model. To account for partial sintering at the boundary of the defect, the transition between solid and powder layers was modeled as a Gaussian. Using data from COMSOL simulations, we reconstructed depth-dependent thermal effusivity, which allowed defect visibility estimation. A series of parametric studies determined that at 1mm depth, 50µm is the smallest detectable defect. In addition, classification of the defects which can lead to early fatigue of the metallic structure in a reactor is briefly discussed.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Performance of Compact Pulsed Thermal Imaging System for In-Service Applications. Pulsed thermal tomography nondestructive examination of additively manufactured reactor materials and components

Additive manufacturing (AM) is an emerging method for cost-efficient fabrication of complex topology nuclear reactor parts from high-strength corrosion resistance alloys, such as stainless steel and Inconel. AM of metallic structures for nuclear energy applications is currently based on laser powder bed fusion (LPBF) process, which has the capability of melting metallic powder and net shaping the structures with relatively high precision. Some of the challenges with using LPBF method for nuclear manufacturing include the possibility of introducing pores into metallic structures. Integrity of AM structures needs to be evaluated nondestructively because material flaws could lead to premature failures due to creep in high temperature nuclear reactor environment. Currently, there exist limited capabilities to evaluate actual AM structures nondestructively. Pulsed Thermography (PT) imaging provides a capability for non-destructive evaluation (NDE) of sub-surface defects in arbitrary size structures. The PT method is based on recording material surface temperature transients with infrared (IR) camera following thermal pulse delivered on material surface with flash light. The PT method has advantages for NDE of actual AM structures because the method involves one-sided non-contact measurements and fast processing of large sample areas captured in one image. The data cube of PT measurements consists of surface temperature taken at sequential time intervals T(x,y,t). Material defects can be detected either by analyzing the thermograms T(x,y,t) data cube, or by using thermal tomography (TT) algorithm to obtain 3D spatial reconstruction of thermal effusivity e(x,y,z). To reduce the cost and enable in-service NDE in spatially constrained environment, it is highly desirable to develop PT with compact and inexpensive IR camera. Following initial qualification of an AM component for deployment in a nuclear reactor, a compact PT system can also be used for in-service nondestructive evaluation (NDE) applications. However, data cube obtained with PT based on compact IR camera suffers from strong thermal noises and loss of features due to relatively low sampling rate. In this report we describe two unsupervised machine learning (ML) algorithms for enhancement of PT images obtained with compact IR camera. In one approach, we introduce Sparse Coding Discrete Cosine Transform (SC/DCT) algorithm to remove additive white Gaussian noise (AWGN) from spatial thermal effusivity reconstructions. In another approach we introduce a Spatial Temporal Denoised Thermal Source Separation (STDTSS) ML algorithm to process thermograms. The STDTSS algorithm consists of spatial and temporal denoising using Gaussian and Savitzky–Golay filtering, followed by the matrix decomposition using Principal Component Analysis (PCA), and Independent Component Analysis (ICA) to automatically detect flaws. In the work described in this report, we constructed a compact PT system using a relatively small and low-cost FLIR A65 camera, consisting on uncooled microbolometer detector. Performance of SC/DCT algorithm was demonstrated on enhancing TT images of Inconel 718 AM plate. Performance of the STDTSS methods was investigated using thermography data obtained from imaging stainless steel 316L specimens produced with LPBF method with imprinted calibrated porosity defects.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

SU(n) and Quantum SU(n) Symmetries in Physical Systems [Slides]

Presence of SU(n) or other Lie group symmetry in a physical system is its powerful, usually underutilized property. In many cases it allows for finding analytical solutions to nonlinear differential equations describing this system. Power of the method is presented on diversified examples from mathematical physics: Lie-group symmetries in finding solutions of generalized, multidimensional theory of gravity; analytical Dirac–equation solutions for description of conducting polymers; stability of qubit states in quantum computers; spatial defects in condensed matter; reconstruction of 3D object from its 2D tomographic image; significant improvement of numerical solutions stability for Euler equations. The next question after obtaining such Lie group symmetric solution is: does a generalized solution with appropriate quantum group symmetry exists for the given physical system, and if yes what is the physical meaning of the deformation parameter q introduced by such solution. In many cases it can be identified. Any SU(n) solution is by its nature singular, assuming a perfect symmetry of the physical system discussed. Such solution gives a powerful insight to theoretical physics, yet the assumption may be too demanding for experimental applications. Deformation parameter q from a quantum group symmetry allows for a continuum of solutions, more applicable to experiments.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Radiographic Imaging and Tomography

Radiographic imaging and tomography (RadIT) come in many flavors such as X-ray imaging and tomography (IT), proton IT, neutron IT, muon IT, neutrino IT, etc. We identify five RadIT themes: Physics, Sources, Detectors, Methods, and Data Science, which are integral parts of image interpretation and three-dimensional (3D) tomographic reconstruction. Traditionally, RadIT have been driven by medicine, non-destructive testing, material sciences, and security applications. The latest thrusts of growth come from automation, machine vision, additive manufacturing and virtual reality (‘metaverse’). The five RadIT themes parallel their counterparts in optical IT. Synergies among different forms of RadIT and with optical IT motivate further advances towards multi-modal IT and quantum IT.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Combining In-situ Diagnostics and Data Analytics for Discovery of Process-Structure-Property Relationships in AM parts – A Step Toward Digital Twins

In-situ additive manufacturing (AM) diagnostic tools (e.g., optical/infrared imaging, acoustic, etc.) already exist to correlate process anomalies to printed part defects. This current work aimed to augment existing capabilities by: 1) Incorporating in-situ imaging w/ machine learning (ML) image processing software (ORNL- developed "Peregrine") for AM process anomaly detection 2) Synchronizing multiple in-situ sensors for simultaneous analysis of AM build events 3) Correlating in-situ AM process data, generated part defects and part mechanical properties The key R&D question investigated was to determine if these new combined hardware/software tools could be used to successfully quantify defect distributions for parts build via SNL laser powder bed fusion (LPBF) machines, aiming to better understand data-driven process-structure-property- performance relationships. High resolution optical cameras and acoustic microphones were successfully integrated in two LPBF machines and linked to the Peregrine ML software. The software was successfully calibrated on both machines and used to image hundreds of layers of multiple builds to train the ML software in identifying printed part vs powder. The software's validation accuracy to identify this aspect increased from 56% to 98.8% over three builds. Lighting conditions inside the chamber were found to significantly impact ML algorithm predictions from in-situ sensors, so these were tailored to each machine's internal framework. Finally, 3D part reconstructions were successfully generated for a build from the compressed stack of layer-wise images. Resolution differences nearest and furthest from the optical camera were discussed. Future work aims to improve optical resolution, increase process anomalies identified, and integrate more sensor modalities.